Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Safety Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Vinca Institute safety and licensing actions for carbon steel structure removal from RA research reactor SNF pool

Carbon steel structure, inserted in water of the spent nuclear fuel pool of the RA research reactor in 1960 for decontamination of primary cooling circuit components, was recognized as the main source of corrosion in the pool. Inappropriate water chemical parameters have initiated corrosion of aluminum cladding of spent fuel elements stored in aluminum barrels. It was confirmed by measuring of activity of {sup 137}Cs nuclide in the pool water samples. A complex project was developed with the IAEA assistance and R and D Company OEC NIKIMT (RF) to remove the carbon steel structure from the pool, since 2004. After long preparation process, including safety analysis of the operation and Serbian regulatory authority approval, the structure was removed, packed and stored at the Vinca radioactive waste storage from November 2006 to February 2007. This paper underlines major safety and licensing actions taken by the Vinca Institute to safely remove the structure and make a room in the pool basin for future spent nuclear fuel repackage operation. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AFIP-3 Irradiation Summary Report

The Advanced Test Reactor (ATR) Full size plate In center flux trap Position (AFIP) experiment AFIP-3 was designed to evaluate the performance of monolithic fuels at a prototypic scale of 2.25 inches x 21.5 inches x 0.050 inches (5.75 cm x 54.6 cm x 0.13cm). The AFIP-3 experiment was fabricated by hot isostatic pressing (HIP) and consists of two plates, one with a zirconium (Zr) diffusion barrier and one with a silicon (Si) enhanced fuel/clad interface1,2. The following report summarizes the life of the AFIP-3 experiment through end of irradiation, including a brief description of the safety analysis, as-run neutronic analysis results, hydraulic testing results, and thermal analysis results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGING AND SURVEILLANCE OF VITON GLT O-RINGS IN MODEL 9975 SHIPPING PACKAGES

Radioactive material packages (DOT Type B) such as the Model 9975 are used to transport Pu-bearing materials. The 9975 package provides double payload containment via nested stainless steel primary (PCV) and secondary (SCV) containment vessels. The containment vessels are closed by a conical plug sealed with dual O-rings (Figure 1) made of Parker Seals compound V0835-75, based on Viton{reg_sign} GLT fluoroelastomer. The outer O-ring is credited as being leaktight per ANSI N14.5 with a leak rate of <1E-07 ref cc/sec. The 9975 package is being used for interim storage in the K-Area Material Storage (KAMS) facility at the Savannah River Site. The aging performance of the O-rings is being studied to provide the storage facility a technical basis for service life prediction and safety analysis.

36 MATERIALS SCIENCE↗

External Events Analysis for LWRS/RISMC Project: Methodology Development and Early Demonstration

The ultimate scope of Industrial Application no.2 (IA) of the LWRS/RISMC project is a realistic simulation of natural external hazards that impose threat to a NPP. This scope requires the development of a methodology and of a qualified set of tools able to perform advanced risk-informed safety analysis. In particular the methodology should be able to combine results from seismic, flooding and thermal-hydraulic (TH) deterministic calculations with dynamic PRA. A so-called Risk Informed Margin Management (RIMM) approach is being used to represent meaningful (i.e., realistic facility representation and simulation) event scenarios and consequences by linking probabilistic simulations to external events physics. Calculations performed so far demonstrated the capabilities of the proposed methodology in analyzing multi-hazards generated by External Events. The sample application described in this paper allowed identifying the main issues (code interfaces, computational and human resources needed, simplifications) connected to such kind of advanced analysis. The next steps will be the risk-informed earthquakes and flooding analysis of a system of a generic PWR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

STAT7 v2.0 User Guide

The STAT7 software was developed to perform steady-state, single-phase thermal hydraulics analysis of plate-fueled reactors based on statistical propagation of uncertainties. Application of the software includes non-power research and test reactor analysis, and it has been used for the conversion to low- enriched uranium fuel of U.S. High Performance Research Reactors such as the Massachusetts Institute of Technology Research Reactor. Since it can be necessary to repeat reactor safety analysis, such as during fuel reloading, STAT7 accommodates flexibility in analyzing many practical aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model uncertainty in common fuel fabrication parameters and other key reactor operating parameters required for reactor thermal hydraulics analysis. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux, or onset of flow instability. STAT7 supports water properties based on the IAPWS-IF97 functions (The International Association for the Properties of Water and Steam Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam) in addition to fitted functions. STAT7 predicts axial profiles of fuel, cladding, and coolant temperature along a lateral stripe that runs the full length of the fuel plate from the bottom to the top. STAT7 can simultaneously analyze every axial node in each lateral stripe of all fuel plates and coolant channels in every fuel element of an entire reactor core. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. In a single execution, STAT7 can be used to perform full core analysis by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each fuel element in the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DOE Hanford Tank Side Cesium Removal System (TSCR) Update: Fabrication and Factory Acceptance Testing - 20300

The Tank Side Cesium Removal (TSCR) System is a modular, quickly-deployable, and passively safe system for efficiently removing solids and cesium from alkaline liquid waste raffinate created by fuel processing on the Hanford site. This paper provides an overview of the project with particular emphasis on completion of fabrication and factory acceptance testing (FAT). All TSCR System components are inside three enclosures known as the Process Enclosure, Ancillary Enclosure, and Control Enclosure. The Process Enclosure is seismic design category II (SDC-II) and built to withstand the rigors of transportation and lifting, high winds, volcanic ash fall, and heavy precipitation (snow) over a temperature range of -25 to 115 deg. F. The Process Enclosure and Control Enclosure were fabricated in AVANTech's Columbia, SC facility, while the Ancillary Enclosure was fabricated in AVANTech's Richland, WA facility. The design and preliminary documented safety analysis were completed in December 2019, with all work being performed in accordance with ASME NQA-1 quality assurance requirements. The Process Enclosure, Ion Exchange Columns (IXCs), and several other TSCR components have a nuclear safety function and are designated as safety significant structures, systems, and components (SS-SSCs). The NQA-1 Commercial Grade Dedication (CGD) process was used to identify critical characteristics in order to accept materials and items used for fabrication of several safety significant TSCR components. This paper also addresses unique aspects and challenges of implementing CGD in DOE facilities and systems. After fabrication and preliminary testing, the Process and Control Enclosures were shipped to AVANTech's Richland facility where the complete TSCR System was setup and connected in a represented layout and configuration that will be used on the Hanford site. Test tanks and pumps were put in place and connected to the TSCR Process Enclosure in a manner that mimicked interfacing Double Shell Tanks in the 241-AP Tank Farm. The TSCR System was then tested/operated under conditions equivalent to those planned for onsite operation. Testing was separated into five separate phases as defined below: - Phase 1: Confirmation of TSCR System readiness for the FAT; - Phase 2: Verification of TSCR System operation under standard conditions; - Phase 3: Demonstration of TSCR System operation under non-standard conditions; - Phase 4: Demonstration of ion exchange media removal from an IXC; and - Phase 5: Completion of TSCR System lift plans and site mobilization. The Hanford Tank Operations Contractor, Washington River Protection Solutions (WRPS), participated in all phases of testing. Testing at AVANTech's Richland Facility allowed WRPS personnel to familiarize themselves with TSCR operations in a radiologically clean facility prior to onsite mobilization. Engineering and operations personnel gained valuable experience that allowed them to better refine onsite operational protocols and procedures - including handling and movement of IXCs with a forklift. This paper describes the technologies used by the TSCR System as well as how these technologies are deployed and operated to advance the Hanford mission of safely, efficiently, and effectively treating tank waste. It also provides detailed information on fabrication and FAT, including operational data from simulated tank waste runs. A project schedule for WRPS' planned construction acceptance testing, operational acceptance testing, and actual tank waste treatment is provided. This presentation should be of great interest to parties responsible for the design, testing, and mobilization of modular NQA-1 technologies for the treatment of raffinate and similar liquid wastes containing high concentrations of radioactive cesium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AREVA NP MR Cladding benefits for proposed US NRC RIA and LOCA requirements

M5 is the reference alloy of AREVA NP for PWR cladding applications. It is a zirconium-based alloy containing 1% niobium, no tin, and well-controlled oxygen, iron, and sulfur contents. It has a fully recrystallized microstructure. The absence of tin in M5 results in a very low corrosion rate and hydrogen pick-up during normal operation, even at high burn-up and in high duty irradiation conditions. Due to this low hydrogen pick-up under irradiation (typically less than 100 ppm, End of Life), M5 retains a very good strength and an exceptional residual ductility during and after the accident. This allows utilities implementing M5 to simplify the safety analysis and to demonstrate significant margins regarding fuel related criteria. Simplified methods are easier for plants to implement and maintain for future plant operations and core design management. This paper specifically presents 3 examples on the safety improvement brought by M5 cladding. First, during a reactivity-induced accident (RIA), the properties of M5 are such that bounding analyses for future cycles are significantly simplified, in particular by demonstrating that fuel dispersal will not occur. The major aspects of the AREVA NP RIA methodology are presented. A second focus is made on the low hydrogen embrittlement of M5 and on its high ductility after quenching during a loss-of-coolant accident (LOCA). In a third part, the breakaway oxidation testing program currently under development in Paimboeuf (France) is described, including details about the testing devices and qualification. The tests have demonstrated that M5 cladding does not have breakaway at least up to 5000 s oxidation duration at 1000 C. degrees, which is much higher than the LOCA duration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technical Review Report for the Justification for 9975 Gram Based Content Envelopes, C.10 and C.11

The Department of Energy (DOE) desires to ship Model 9975-85 and Model 9975-96 Packages loaded with Pu/U metal and Pu/U oxide materials as identified in new Content Envelopes C.10 and C.11. The new Content Envelopes C.10 and C.11 consist of radioisotopes and impurities that are similar to the existing C.3, Pu/U metal, and C.4, Pu/U oxide, Content Envelopes but that list the radioisotopes as gram values in lieu of the existing weight percent of radioactive material mass values listed for the C.3 and C.4 Content Envelopes. Authorization for shipment requires acceptance of this report by the DOE-Headquarters (HQ) Certifying Official (EM-10/EM-2) as an Addendum to WSRC-SA-2002-00008, Revision 0, S-SARA-G-00001, Addendum 1, Revision 0, and S-SARA-G-00002 Addendum 2, Revision 1, of the Model 9975-85 Package Safety Analysis Report for Packaging (SARP). This Addendum also applies to S-SARP-G-00003, Revision 0, of the Model 9975-96 Package SARP. These documents are collectively referred to as the existing Model 9975 Package SARP. The safety basis described addresses specific supplements to the currently approved safety basis. Justification is made for shipping the new Content Envelopes C.10 and C.11 under this Addendum. Following acceptance of this Addendum by EM-10/EM-2 and subsequent revision to the current Certificates of Compliance (CoCs), the new contents will be authorized for shipment in the Model 9975 Package. The new Content Envelopes will be incorporated into the next revision to the Model 9975-85 and Model 9975-96 Package SARPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

The document compiles in a single volume several verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. Some works that are available in the open literature are simply referenced at the outset, and are not included in the document. PLTEMP has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a more validated code like the RELAP5 code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Scale Model for High Flux Isotope Reactor Cycle 400

The development of a comprehensive SCALE computational model for the High Flux Isotope Reactor (HFIR) is documented and discussed in this report. The SCALE model has equivalent features and functionality as the reference MCNP model for Cycle 400 that has been used extensively for HFIR safety analyses and for HFIR experiment design and analyses. Numerical comparisons of the SCALE and MCNP models for the multiplication constant, power density distribution in the fuel, and neutron fluxes at several locations in HFIR indicate excellent agreement between the results predicted with the two models. The SCALE HFIR model is presented in sufficient detail to provide the users of the model with a tool that can be easily customized for various safety analysis or experiment design requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

U.S. Department of Energy Implementation of Chemical Evaluation Requirements for Transuranic Waste Disposal at the Waste Isolation Pilot Plant

This report summarizes new controls designed to ensure that transuranic waste disposed at the Waste Isolation Pilot Plant (WIPP) does not contain incompatible chemicals. These new controls include a Chemical Compatibility Evaluation, an evaluation of oxidizing chemicals, and a waste container assessment to ensure that waste is safe for disposal. These controls are included in the Chapter 18 of the Documented Safety Analysis for WIPP (1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress Updates for the Hanford Waste Treatment and Immobilization Plant Project - 16281

The Waste Treatment and Immobilization Plant (WTP) Project is vital to the U.S. Department of Energy's (DOE) mission to clean up radioactive waste at the Hanford Site, located in southeastern Washington State. The overall WTP Project objective is to design, build, and commission the facilities and systems that will treat and immobilize approximately 56 million gallons of radioactive waste stored in Hanford's 177 underground storage tanks. The combination of technologies in the WTP makes it a first-of-a-kind facility at a scale larger than ever built for radioactive waste processing. The WTP includes several facilities that will contribute to waste processing: (1) the Pretreatment (PT) Facility, which is designed to receive waste retrieved from the Hanford tank farms and separate it into low-activity and high-level waste streams; (2) the Low-Activity Waste (LAW) Facility, which will vitrify the low-activity waste stream; (3) the High-Level Waste (HLW) Facility, which will vitrify the high-level waste stream; (4) the Analytical Laboratory (Lab), which will support both vitrification facilities' operations; and (5) the Balance of Facilities (BOF), which will provide industrial support capabilities and infrastructure, like electricity and steam, needed for WTP operations. In 2012, DOE suspended production work on the WTP's Pretreatment (PT) Facility and to a lesser degree the High-Level Waste (HLW) Facility because of unresolved technical issues associated with those facilities. DOE has established an approach that would facilitate immobilization of tank waste to begin as early as practicable without waiting for completion of work to resolve the technical issues associated with the PT and HLW Facilities. This approach enables LAW treatment to begin before the PT and HLW facilities are completed by transferring low activity waste directly from the Hanford tank farms to the LAW Facility - referred to as Direct Feed LAW (DFLAW). ORP has placed the highest priority on completing the Low Activity Waste Facility, Balance of Facilities, and Analytical Laboratory (collectively known as LBL) in support of the planned phased start to the Hanford Tank waste treatment mission. DOE has requested, and the WTP contractor has delivered contract modifications proposals for: (1) design of a permanent capability to accommodate DFLAW in WTP; (2) procurement and construction of modifications to enable DFLAW operations in WTP, and (3) completion of LBL work scope in the current contract through hot commissioning in a manner to accommodate a phased start toward completing the WTP mission. DOE is reviewing and approving contract modifications in a sequence and schedule that allows for an orderly completion of the LBL Facilities and to begin treating low-activity tank waste as soon as practicable. In August 2014, ORP authorized the WTP contractor to resume all engineering work necessary to finalize the design of the HLW Facility. Authorization for HLW equipment procurements and construction is forthcoming, based on conditions that must be satisfied for a full release of these activities, including completion of an update to the Preliminary Documented Safety Analysis. DOE has also established a comprehensive plan for resuming production activities for the PT Facility that is similar to the process established and implemented for the HLW Facility. Resolution of the technical issues and establishment of a revised safety basis are key prerequisites to resuming engineering, procurements, and construction. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

C-Band Airport Surface Communications System Engineering-Initial High-Level Safety Risk Assessment and Mitigation

This document is being provided as part of ITT's NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract: "New ATM Requirements--Future Communications, C-Band and L-Band Communications Standard Development." ITT has completed a safety hazard analysis providing a preliminary safety assessment for the proposed C-band (5091- to 5150-MHz) airport surface communication system. The assessment was performed following the guidelines outlined in the Federal Aviation Administration Safety Risk Management Guidance for System Acquisitions document. The safety analysis did not identify any hazards with an unacceptable risk, though a number of hazards with a medium risk were documented. This effort represents an initial high-level safety hazard analysis and notes the triggers for risk reassessment. A detailed safety hazards analysis is recommended as a follow-on activity to assess particular components of the C-band communication system after the profile is finalized and system rollout timing is determined. A security risk assessment has been performed by NASA as a parallel activity. While safety analysis is concerned with a prevention of accidental errors and failures, the security threat analysis focuses on deliberate attacks. Both processes identify the events that affect operation of the system; and from a safety perspective the security threats may present safety risks.

Zelkin, Natalie↗

HotSpot Software Test Plan

This Software Test Plan (STP) describes the procedures used to verify and validate that the HotSpot Health Physics Codes meet the requirements of its user base, which includes: (1) Users of the PC version of HotSpot conducting consequence assessment, hazard assessment and safety analysis calculations; and (2) Users of the NARAC Web and iClient software tools, which allow users to run HotSpot for consequence assessment modeling. This plan is intended to meet Critical Recommendation 2 from the Software Evaluation of HotSpot and DOE Safety Software Toolbox Recommendation for inclusion of HotSpot in the Department of Energy (DOE) Safety Software Toolbox. These users and sponsors of the HotSpot software and the organizations they represent constitute the intended audience for this document. HotSpot software is maintained for the Department of Energy Office of Emergency Operations by the National Atmospheric Release Advisory Center (NARAC) at Lawrence Livermore National Laboratory (LLNL). An overview of HotSpot and NARAC are provided.

99 GENERAL AND MISCELLANEOUS↗

CFD SIMULATION OF PROPOSED VALIDATION DATA FOR A FLOW PROBLEM RECONFIGURED TO ELIMINATE AN UNDESIRABLE FLOW INSTABILITY

The U. S. Department of Energy (DOE) is supporting the development of a next generation nuclear plant (NGNP), which will be based on a very high temperature reactor (VHTR) design. The VHTR is a single-phase helium-cooled reactor wherein the helium will be heated initially to 750 °C and later to temperatures approaching 1000 °C. The high temperatures are desired to increase reactor efficiency and to provide a heat source for the manufacture of hydrogen and other applications. While computational fluid dynamics (CFD) has not been used in the past to design or license nuclear reactors in the U. S., it is expected that CFD will be used in the design and safety analysis of forthcoming designs. This is partly because of the maturity of CFD and partly because detailed information is desired of the flow and heat transfer inside the reactor to avoid hot spots and other conditions that might compromise reactor safety. Numerical computations of turbulent flow should be validated against experimental data for flow conditions that contain some or all of the physics expected in the thermal fluid machinery of interest. To this end, a scaled model of a narrow slice of the lower plenum of the prismatic VHTR was constructed and installed in the Idaho National Laboratory’s (INL) matched index of refraction (MIR) test facility and data were taken. The data were then studied and compared to CFD calculations to help determine their suitability for validation data. One of the main findings was that the inlet data, which were measured and controlled by calibrated mass flow rotameters and were also measured using detailed stereo particle image velocimetry (PIV) showed considerable discrepancies in mass flow rate between the two methods. The other finding was that a randomly unstable recirculation zone occurs in the flow. This instability has a very significant effect on the flow field in the vicinity of the inlet jets. Because its time scale is long and because it is apparently a random instability, it was deemed undesirable for a validation data set. It was predicted using CFD that by eliminating the first of the four jets, the recirculation zone could be stabilized. The present paper reports detailed results for the three-jet case with comparisons to the four-jet data inasmuch as three-jet data are still unavailable. Hence, the present simulations are true or blind predictions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TCR Postulated Accident and MHA Dose Assessment

Oak Ridge National Laboratory (ORNL) is engaged in regulatory activities to gain US Department of Energy (DOE) approval to build and operate a small high-temperature gas reactor, the Transformational Challenge Reactor (TCR). ORNL uses advanced manufacturing techniques to produce select reactor components. The TCR is unique in its mission: the reactor’s at-power operating lifetime will be less than one effective full-power day to limit the radiological source term to very low values, thus facilitating approval to operate. The primary regulatory documents governing construction and operation of the facility are NUREG-1537, “Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors” and DOE-STD-3009, “Preparation of Nonreactor Nuclear Facility Documented Safety Analysis.” Although this document is not a safety basis document, it provides a conservative indication of the magnitude of onsite and offsite radiological doses for specific scenarios, thus informing future design and regulatory activities. As required by NUREG-1537, scenarios included in this analysis are (1) a worstcase depressurized loss-of-forced-circulation accident, and (2) a maximum hypothetical accident. Details on the analysis of dose consequences with various system configurations are also provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Qualitative Evaluation of Human Reliability Analysis Quality

On August, 2001, the Korean government issued a severe accident policy statement. In this policy statement, a safety goal was proposed in a form of quantitative health objective(QHO) such that an additive risk of early fatality and cancer fatality caused by accident or operation of nuclear power plant(NPPs) should not exceed 0.1% of the sum of other accidents and cancer fatality risks resulting from all other causes, respectively. In accordance with the policy statement, probabilistic safety analysis(PSA) for all Korean NPPs was conducted to show each plant satisfies QHO. Given the increasing importance of PSA to assess the level of safety of NPPs, it is crucial that the quality of the PSA results should be assured. Compared to well-established PSA method used for domestic NPPs, there is consensus that human reliability analysis (HRA) has lack of consistency due to the different assumptions and different characteristics of the methods, which could possibly result in low quality of the PSA. To resolve the issues with lack of consistency of the HRA methods, there have been efforts to develop a standardized HRA method in Korea. However, quality of existing Korean HRA should be evaluated before developing a standardized method, since the results can be used for deriving requirements and give feedback and insights for developing the standardized method. In this study, literature review was performed to select an adequate method for evaluating the quality of the HRA, and the quality of the HRA is evaluated. Finally, results and insights of this study are shown in the conclusion. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A stress-state modified strain based failure criterion for evaluating the structural integrity of an inner eutectic barrier.

A slight modification of a package to transport solid metal contents requires inclusion of a thin titanium liner to protect against possible eutectic formation in 10 CFR 71.74 regulatory fire accident conditions. Under severe transport regulatory impact conditions, the package contents could impart high localized loading of the liner, momentarily pinching it between the contents and the thick containment vessel, and inducing some plasticity near the contact point. Actuator and drop table testing of simulated contents impacts against liner/containment vessel structures nearly bounded the potential plastic strain and stress triaxiality conditions, without any ductile tearing of the eutectic barrier. Additional bounding was necessary in some cases beyond the capability of the actuator and drop table tests, and in these cases a stress-modified evolution integral over the plastic strain history was successfully used as a failure criterion to demonstrate that structural integrity was maintained. The Heaviside brackets only allow the evolution integral to accumulate value when the maximum principal stress is positive, since failure is never observed under pure hydrostatic pressure, where the maximum principal stress is negative. Detailed finite element analyses of myriad possible impact orientations and locations between package contents and the thin eutectic barrier under regulatory impact conditions have shown that not even the initiation of a ductile tear occurs. Although localized plasticity does occur in the eutectic barrier, it is not the primary containment boundary and is thus not subject to ASME stress allowables from NRC Regulatory Guide 7.6. These analyses were used to successfully demonstrate that structural integrity of the eutectic barrier was maintained in all 10 CFR 71.73 and 71.74 regulatory accident conditions. The NRC is currently reviewing the Safety Analysis Report.

36 MATERIALS SCIENCE↗