Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Bio-Based Phase Change Materials (PCMs) for Thermal Energy Storage (Final Scientific/Technical Report)

The goal of this project is to develop a novel bio-based phase change material (PCM) derived from squid ring teeth (SRT) proteins, and design a prototype heat exchanger based on these bio-based PCMs for energy storage and dynamic heat exchange for building thermal energy storage systems. The PCMs, derived from SRT proteins, will demonstrate room temperature energy storage capacities and switchable thermal conductivities that redefine the current state-of-the-art (SOA) for building thermal energy storage. Further, in a single material and with a single manufacturing processes, our proposed thermal battery will be developed with “on demand” thermal conductivity for rapid charging/discharging but superior insulation during energy storage periods. More specifically, our bio-based PCMs have demonstrated: 1) the potential for increased energy storage capacity (i.e., greater than paraffines at room temperature); 2) tunability in thermal conductivity with the largest thermal conductivity switching ratios for an intrinsic material reported to date, and 3) a 100% recyclable and biodegradable PCM with low volatility and toxicity and scalability in its manufacture for both residential and commercial applications. The already established ability for roll-to-roll processing of these non-toxic, non-flammable SRT composites along with their carbon-neutral manufacturing processes that has been pioneered by our team make this solution a disruptive and impactful technology to redefine the current SOA of energy storage technologies. The outcomes of this effort have been: 1) the identification of new bio-based PCM that establishes a new SOA for thermal conductivity and energy storage density at room temperature and 2) the development of a new experimental technique to measure the energy storage density via latent heat measurements during melting of thin films. This new technique can be applied to thin films (as thin as < 1 micrometer), and represents a novel approach for thin film energy storage density measurements. Dynamic thermal energy storage is the missing technology that will enable a grid- interactive efficient building (GEB). For a “smart” building capable of connecting with the power grid, the media must be inexpensive and possess thermal switching capabilities to control the time-dependent heat flow into (and out of) the PCM on demand. Unique to the material system in this program, programmable SRT-based PCM show improvements as compared to traditionally used PCMs, and thus its technical performance will represent a leap forward for the future GEB concept.

25 ENERGY STORAGE↗

The effects of storage on the net calorific value of wood pellets

The wood pellet export from Canada to Europe has been increasing steadily in recent years (roughly 1.8 million ton in 2013). Due to distances involved, wood pellets remain in transit and storage for months before their final consumption. The net calorific value determines the price of wood pellet purchase in Europe. There have been concerns about the changes of net calorific values over time. In this study, the effects of storage time, storage configuration, storage temperature, and wood pellet quality on the net calorific value of wood pellets for a period of 6 months were investigated. Storage configurations were open or closed and storage temperatures were 25 °C, 35 °C and 45 °C. Two types of wood pellets used were whitewood and mixed. The results in closed storage indicated that storage time had a positive effect on the net calorific value where the net calorific value increased by 1% to 2% over the storage period. In open storage, the moisture content had the most significant impact on the net calorific value. The net calorific values of the two types of wood pellets were found to be significantly different at p < 0.001. A multivariable linear regression and analyses of variance performed verified the graphical results. Lastly, the authors postulated that the higher energy potential compounds, such as aldehyde and ketone, produced during pellet storage, caused the increase in net calorific values.

09 BIOMASS FUELS↗

Development of Flexible Energy Storage Device for Wearable Electronics using All-organic Composites

As the demands and applications of wearable electronics increase, the need of power supply for wearable electronics becomes the critical issue. Both batteries and capacitors can be used as power supplier. In terms of energy storage device, capacitors have many advantages over the batteries, but have a lower energy storage density. To improve the energy density, composites, in which inorganic particles are embedded in a polymer matrix, have been identified as a promising approach to create the dielectrics with a higher energy storage density. The physics behind the composite approach is that the inorganics have a higher dielectric constant and polymers can stand with a higher electric field so that the composites can exhibit a relative dielectric constant and stand with a relative electric field. Therefore, the composites can exhibit a higher energy storage density. However, the embedment of inorganic particles into polymer severely reduces the flexibility of the polymer. To develop flexible energy storage ultracapacitors as an energy storage device for wearable electronics, an all-organic composite approach, in which a dielectric polymer is mixed with polar organic molecules, is introduced. It is experimentally found that by adding a small amount of polar organic molecules into dielectric polymers, the polymers exhibits a high dielectric constant and can stand with a higher electric field. More importantly, the flexibility of the all-organic composites is better than the polymer matrix. Therefore, the all-organic composites can be a strong and promising candidate for the development of flexible energy storage devices for the wearable electronics. In this study, three different dielectric polymers and three different polar molecules were studied. All the all-organic composite systems exhibit a significant improvement on the energy storage density. These new flexible energy storage devices are being developed to be fabricated with on-demandadditive electronics manufacturing processes, so that they can be fabricated when needed in space on the International Space Station and planned lunar habitat and other future missions. These flexible energy storage devices will provide the storage in concert with other printed power generation devices to allow crew health and structural health monitoring sensor devices and systems to be self-powered, not requiring any external power or batteries.

energy storage↗

Evaluation of Aluminum-clad Spent Nuclear Fuel during Drying and Dry Storage

The DOE SNF Working Group ASNF Subgroup and the U.S. Nuclear Waste Technical Review Board have identified knowledge gaps regarding the management of aluminum-clad spent nuclear fuel (ASNF).[1, 2] The objectives of this research are to observe, sample and analyze the nature of aluminum surface corrosion and corrosion layer chemistry relevant to the ASNF performance over the duration of the dry storage segment of the fuel life cycle. The primary goal is to build an understanding of ASNF behavior, from reactor service and wet storage through drying and dry storage, with parallel testing of surrogate materials. The premise is that residual water affiliated with the aluminum oxide from corrosion during reactor service and wet storage, continues to influence ASNF performance during dry storage, and that even after successful drying the surface conditions of ASNF have yet to be satisfactorily characterized. The initial scope collected and analyzed specimens from irradiated non-fuel components of aluminum-clad Advanced Test Reactor (ATR) fuel elements that are routinely removed at the end of reactor service life. Techniques have been developed for remote material sampling from ATR elements from vented dry storage at the Irradiated Fuel Storage Facility (IFSF). These techniques involve 1) nipping off a small corner of the aluminum near where the end box had been removed and 2) scraping the exterior (non-fueled) plate surface to collect an oxide sample. This second effort targets ATR elements expected to have seen the longest residence in storage, both in the CPP-603 pool (with poor water quality) and in dry storage at IFSF, within the fuel handling scheduled to consolidate ATR at IFSF and receive the remaining inventory at CPP-666. Follow on work has been proposed to nip corners and collect scrapings immediately following ATR fuel drying, before placement in dry storage. Sample analysis will use multiple techniques to understand the chemical composition and morphology of the surface oxides. A simultaneous effort is progressing to develop surrogate materials to enable rigorous controlled experiments. Consistently produced, these surrogate materials can then be used to demonstrate limitations inherent to remote sampling and to validate performance models under relevant constraints. The combined efforts will substantiate ASNF performance and fuel management decisions regarding drying and packaging over a more complete range of life cycle conditions. [1] DOE Spent Nuclear Fuel Working Group, Aluminum-Clad Spent Nuclear Fuel: Technical Considerations and Challenges for Extended (>50 Years) Dry Storage, DOE/ID RPT#: 1575, prepared by Aluminum-Clad SNF Sub Working Group, June 2017. [2] U.S. Nuclear Waste Technical Review Board, Management and Disposal of U.S. Department of Energy Spent Nuclear Fuel, A Report to the United States Congress and the Secretary of Energy, December 2017, p. 143.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermodynamic performance and cost optimization of a novel hybrid thermal-compressed air energy storage system design

Compressed Air Energy Storage (CAES) can potentially allow renewable energy sources to meet electricity demands as reliably as coal-fired power plants. However, conventional CAES systems rely on the combustion of natural gas, require large storage volumes, and operate at high pressures, which possess inherent problems such as high costs, strict geological locations, and the production of greenhouse gas emissions. A novel and patented hybrid thermal-compressed air energy storage (HT-CAES) design is presented which allows a portion of the available energy, from the grid or renewable sources, to operate a compressor and the remainder to be converted and stored in the form of heat, through joule heating in a sensible thermal storage medium. The HT-CAES design incudes a turbocharger unit that provides supplementary mass flow rate alongside the air storage. The hybrid design and the addition of a turbocharger have the beneficial effect of mitigating the shortcomings of conventional CAES systems and its derivatives by eliminating combustion emissions and reducing storage volumes, operating pressures, and costs. Storage efficiency and cost are the two key factors, which upon integration with renewable energies would allow the sources to operate as independent forms of sustainable energy. The potential of the HT-CAES design is illustrated through a thermodynamic optimization study, which outlines key variables that have a major impact on the performance and economics of the storage system. The optimization analysis quantifies the required distribution of energy between thermal and compressed air energy storage, for maximum efficiency, and for minimum cost. This study provides a roundtrip energy and exergy efficiency map of the storage system and illustrates a trade off that exists between its capital cost and performance.

25 ENERGY STORAGE↗

Techno-Economic Analysis of a Cryogenic Flux Capacitor for Grid Storage

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature, high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, is constructed from readily available commercial materials, lends itself to a range of pressure applications, and is geometry insensitive. The high energy density of CFC-stored hydrogen allows long durations of storage, such as daily to monthly cycling, which corresponds to approximately 10 to 100 hours of duration, respectively. The techno-economic analysis examines different types of hydrogen storage for commercial viability. The assessment includes the use of hydrogen blended with natural gas in a combined cycle gas turbine. The study provides results for a range of blends from 100% natural gas to 100% hydrogen. The required fuel usages are estimated for the intended application in a grid scenario that features large amounts of renewable penetration, 10 hours, and as a baseload, 100 hours. The study presents preliminary estimates of the capital cost of storage and operating cost of storage. In addition, the cost of firing natural gas and capturing the carbon dioxide (CO2) in a carbon capture and sequestration (CCS) system is assessed. Based on the study, it is shown that CFC can competitively meet performance and cost needs for grid-based energy storage.

08 HYDROGEN↗

Regulatory Basis for Dry Spent Nuclear Fuel Storage Canister Inspections

Nuclear power plants in the United States began moving Spent Nuclear Fuel (SNF) from wet storage to dry storage in Independent Spent Fuel Storage Installations (ISFSIs) in 1986 at Surry station in Virginia. Dry storage represented an innovative solution to the problem created by the U.S. government's failure to fulfill its obligation to begin removing SNF from power plant sites. Today, about 70 ISFSIs have been placed into operation on the sites of current, or former nuclear power plants. There are currently over 2,200 SNF dry storage systems (DSSs) in service at these locations. Thirteen of these ISFSIs are located at sites with no operating reactor, and this number is due to increase in the coming years. Operating nuclear power stations use ISFSI storage to maintain wet storage capacity for recently discharged SNF. Permanently shutdown nuclear power plants use ISFSI storage to allow decommissioning and dismantlement of the power plant structures, systems, and components. The U.S. Nuclear Regulatory Commission (NRC) regulates the licensing, construction, and operation of ISFSIs under Title 10 of the U.S. Code of Federal Regulations, Energy, Part 72, Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater than Class-C Waste (10 CFR 72). When the regulations in 10 CFR 72 were created around 1980, 20 years was chosen by the NRC as the license term for a specific ISFSI license and later, for a DSS Certificate of Compliance (CoC). Twenty years was, at the time, believed to be a sufficient time period for on-site interim dry storage of spent nuclear fuel before the U.S. government began moving the spent fuel away from the plant site for final disposal. Little, if any consideration was given to providing a regulatory framework for extending ISFSI licenses and DSS CoCs beyond 20 years at that time. However, shortly after the turn of the century, with still no federal program for removing SNF from reactor sites on the near-term horizon it became apparent that most DSSs would be required to remain in service at the ISFSIs beyond the initial 20-year license term. Operation beyond the original license term requires the specific license or the DSS CoC (used at a general license ISFSI) to be renewed. The requirements for renewal of a specific ISFSI license or a DSS CoC include addressing age-related degradation of structures, systems, and components that perform or support safety functions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mission possible: Unify HPC and Big Data stacks towards application-defined blobs at the storage layer

HPC and Big Data stacks are completely separated today. The storage layer offers opportunities for convergence, as the challenges associated with HPC and Big Data storage are similar: trading versatility for performance. This motivates a global move towards dropping file-based, POSIX-IO compliance systems. However, on HPC platforms this is made difficult by the centralized storage architecture using file-based storage. In this paper we advocate that the growing trend of equipping HPC compute nodes with local storage redistributes the cards by enabling object storage to be deployed alongside the application on the compute nodes. Furthermore, such integration of application and storage not only allows fine-grained configuration of the storage system, but also improves application portability across platforms. In addition, the single-user nature of such application-specific storage obviates the need for resource-consuming storage features like permissions or file hierarchies offered by traditional file systems. In this article we propose and evaluate Blobs (Binary Large Objects) as an alternative to distributed file systems. Finally, we factually demonstrate that it offers drop-in compatibility with a variety of existing applications while improving storage throughput by up to 28%.

97 MATHEMATICS AND COMPUTING↗

Effect of Storage Conditions on Efficacy of Poly(ethylenimine)-Alumina CO 2 Sorbents

Solid amine sorbents are one of the primary components of DAC technologies that allow for the removal of ultradilute CO 2 from the atmosphere. A main drawback in the implementation of solid amine sorbents in industrial-scale DAC applications is their instability under certain operational or storage conditions over an extended period. In this work, the effect of storage temperature and gas composition in the storage headspace on the long-term stability of a poly(ethylenimine)-alumina (PEI/γ-Al 2 O 3 ) sorbent is explored. PEI/γ-Al 2 O 3 sorbents with 70 and 100% pore filling are aged under varying gases (N 2 , O 2 , Ar, 0.04% CO 2 −N 2 , CO 2 , and ambient air) in an oven (40 °C), at common ambient indoor temperature conditions (23 °C), or in a freezer (−4 °C). The CO 2 sorption capacity, as measured by thermogravimetric analysis (TGA), along with FTIR spectra of the fresh and aged sorbents, reveal that at 23 and −4 °C, storage under ambient air or inert gas (Ar) provides reasonable long-term stability, with <13% degradation over 12 and 5 months of storage. Interestingly, with storage at 40 °C, similar levels of deactivation were observed under pure O 2 and N 2 after 4 months of storage, which suggests that nonoxidative thermal reactions can occur under prolonged storage conditions under N 2 . In contrast, with storage under CO 2 , sorbent degradation is substantially suppressed compared to storage under N 2 , ambient air, O 2 , or Ar, yielding sorbents with no observable loss in capacity after 2 months, compared to a 66, 63, and 62% loss under N 2 , ambient air, and N 2 in the same period at 40 °C, respectively. Overall, these findings provide guidance for practical amine sorbent storage in academic or industrial settings where amine sorbents are used for carbon capture.

Atmospheric chemistry↗

Composition and Realization of Source-to-Sink High-Performance Flows: File Systems, Storage, Hosts, LAN and WAN

A number of Department of Energy (DOE) science applications, involving exascale computing systems and large experimental facilities, are expected to generate large volumes of data, in the range of petabytes to exabytes, which will be transported over wide-area networks for the purpose of storage, visualization, and analysis. To support such capabilities, significant progress has been made in various components including the deployment of 100 Gbps networks with future 1 Tbps bandwidth, increases in end-host capabilities with multiple cores and buses, capacity improvements in large disk arrays, and deployment of parallel file systems such as Lustre and GPFS. High-performance source-to-sink data flows must be composed of these component systems, which requires significant optimizations of the storage-to-host data and execution paths to match the edge and long-haul network connections. In particular, end systems are currently supported by 10-40 Gbps Network Interface Cards (NIC) and 8-32 Gbps storage Host Channel Adapters (HCAs), which carry the individual flows that collectively must reach network speeds of 100 Gbps and higher. Indeed, such data flows must be synthesized using multicore, multibus hosts connected to high-performance storage systems on one side and to the network on the other side. Current experimental results show that the constituent flows must be optimally composed and preserved from storage systems, across the hosts and the networks with minimal interference. Furthermore, such a capability must be made available transparently to the science users without placing undue demands on them to account for the details of underlying systems and networks. And, this task is expected to become even more complex in the future due to the increasing sophistication of hosts, storage systems, and networks that constitute the high-performance flows. The objectives of this proposal are to (1) develop and test the component technologies and their synthesis methods to achieve source-to-sink high-performance flows, and (2) develop tools that provide these capabilities through simple interfaces to users and applications. In terms of the former, we propose to develop (1) optimization methods that align and transition multiple storage flows to multiple network flows on multicore, multibus hosts; and (2) edge and long-haul network path realization and maintenance using advanced provisioning methods including OSCARS and OpenFlow. We also propose synthesis methods that combine these individual technologies to compose high-performance flows using a collection of constituent storage-network flows, and realize them across the storage and local network connections as well as long-haul connections. We propose to develop automated user tools that profile the hosts, storage systems, and network connections; compose the source-to-sink complex flows; and set up and maintain the needed network connections. These solutions will be tested using (1) 100 Gbps connection(s) between Oak Ridge National Laboratory (ORNL) and Argonne National Laboratory (ANL) with storage systems supported by Lustre and GPFS file systems with an asymmetric connection to University of Memphis (UM); (2) ORNL testbed with multicore and multibus hosts, switches with OpenFlow capabilities, and network emulators; and (3) 100 Gbps connections from ESnet and their Openflow testbed, and other experimental connections. This proposal brings together the expertise and facilities of the two national laboratories, ORNL and ANL, and UM. It also represents a collaboration between DOE and the Department of Defense (DOD) projects at ORNL by sharing technical expertise and personnel costs, and leveraging the existing DOD Extreme Scale Systems Center (ESSC) facilities at ORNL.

97 MATHEMATICS AND COMPUTING↗

Viability of S3 Object Storage for the ASC Program at Sandia

Recent efforts at Sandia such as DataSEA are creating search engines that enable analysts to query the institution’s massive archive of simulation and experiment data. The benefit of this work is that analysts will be able to retrieve all historical information about a system component that the institution has amassed over the years and make better-informed decisions in current work. As DataSEA gains momentum, it faces multiple technical challenges relating to capacity storage. From a raw capacity perspective, data producers will rapidly overwhelm the system with massive amounts of data. From an accessibility perspective, analysts will expect to be able to retrieve any portion of the bulk data, from any system on the enterprise network. Sandia’s Institutional Computing is mitigating storage problems at the enterprise level by procuring new capacity storage systems that can be accessed from anywhere on the enterprise network. These systems use the simple storage service, or S3, API for data transfers. While S3 uses objects instead of files, users can access it from their desktops or Sandia’s high-performance computing (HPC) platforms. S3 is particularly well suited for bulk storage in DataSEA, as datasets can be decomposed into object that can be referenced and retrieved individually, as needed by an analyst. In this report we describe our experiences working with S3 storage and provide information about how developers can leverage Sandia’s current systems. We present performance results from two sets of experiments. First, we measure S3 throughput when exchanging data between four different HPC platforms and two different enterprise S3 storage systems on the Sandia Restricted Network (SRN). Second, we measure the performance of S3 when communicating with a custom-built Ceph storage system that was constructed from HPC components. Overall, while S3 storage is significantly slower than traditional HPC storage, it provides significant accessibility benefits that will be valuable for archiving and exploiting historical data. There are multiple opportunities that arise from this work, including enhancing DataSEA to leverage S3 for bulk storage and adding native S3 support to Sandia’s IOSS library.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Application of advanced flywheel technology for energy storage on space station

In space power applications where solar inputs are the primary thermal source, energy storage is necessary to provide a continuous power supply during the eclipse portion of the orbit. Because of their potentially high storage density, flywheels are being considered for use as the storage system on the proposed orbiting space station. During the past several years, graphite fiber technology has advanced, leading to significant gains in flywheel storage density. Use of these improved fibers in experimental flywheel rims has resulted in ultimate storage densities of 878 kJ/kg. With these high strength graphite fibers, operational storage densities for flywheel storage modules applicable to the space station power storage could reach 200 kJ/kg. This module would also be volumetrically efficient occupying only about 1 cu m. Because the size and mass of the flywheel storage module are controlled by the storage density, improvements in fiber strength can have a significant impact on these values. With the improvements anticipated within the next five years, operational storage density on the order of 325 kJ/kg may be possible for the flywheel module.

Olszewski, Mitchell↗

Impact of Water Withdrawals from Groundwater and Surface Water on Continental Water Storage Variations

Humans have strongly impacted the global water cycle, not only water flows but also water storage. We have performed a first global-scale analysis of the impact of water withdrawals on water storage variations, using the global water resources and use model WaterGAP. This required estimation of fractions of total water withdrawals from groundwater, considering five water use sectors. According to our assessment, the source of 35% of the water withdrawn worldwide (4300 cubic km/yr during 1998-2002) is groundwater. Groundwater contributes 42%, 36% and 27% of water used for irrigation, households and manufacturing, respectively, while we assume that only surface water is used for livestock and for cooling of thermal power plants. Consumptive water use was 1400 cubic km/yr during 1998-2002. It is the sum of the net abstraction of 250 cubic km/yr of groundwater (taking into account evapotranspiration and return flows of withdrawn surface water and groundwater) and the net abstraction of 1150 km3/yr of surface water. Computed net abstractions indicate, for the first time at the global scale, where and when human water withdrawals decrease or increase groundwater or surface water storage. In regions with extensive surface water irrigation, such as Southern China, net abstractions from groundwater are negative, i.e. groundwater is recharged by irrigation. The opposite is true for areas dominated by groundwater irrigation, such as in the High Plains aquifer of the central USA, where net abstraction of surface water is negative because return flow of withdrawn groundwater recharges the surface water compartments. In intensively irrigated areas, the amplitude of seasonal total water storage variations is generally increased due to human water use; however, in some areas, it is decreased. For the High Plains aquifer and the whole Mississippi basin, modeled groundwater and total water storage variations were compared with estimates of groundwater storage variations based on groundwater table observations, and with estimates of total water storage variations from the GRACE satellites mission. Due to the difficulty in estimating area-averaged seasonal groundwater storage variations from point observations of groundwater levels, it is uncertain whether WaterGAP underestimates actual variations or not. We conclude that WaterGAP possibly overestimates water withdrawals in the High Plains aquifer where impact of human water use on water storage is readily discernible based on WaterGAP calculations and groundwater observations. No final conclusion can be drawn regarding the possibility of monitoring water withdrawals in the High Plains aquifer using GRACE. For the less intensively irrigated Mississippi basin, observed and modeled seasonal groundwater storage reveals a discernible impact of water withdrawals in the basin, but this is not the case for total water storage such that water withdrawals at the scale of the whole Mississippi basin cannot be monitored by GRACE.

Doell, Petra↗

Techno-Economic Analysis of Green Hydrogen Energy Storage in A Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH 2 ) storage and liquid hydrogen (LH 2 ) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows its storage performance to easily exceed capacities of high-pressure GH 2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH 2 at the same operating temperature and pressure. For LH 2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH 2 . The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH 2 systems is estimated to be $210/MWh and cost of storage for LH 2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

Joshua Schmitt↗

The Peaking Potential of Long-Duration Energy Storage in the United States Power System

In this work, we investigated the peaking potential for storage with durations of 4 h up to durations of 168 h (1 week). The peaking potential for a given storage duration is the amount of storage that can be added to a power system before that storage can no longer serve the peak net demand period at full rated capacity. We found that for the United States, 168 h of storage would be sufficient to serve about 27 % of peak demand, or about 215 GW in the current system. However, more than one-half of this amount could be served by storage with 12 h or less of capacity. As deployment of wind and solar grows, the peaking potential increases significantly, and under decarbonization scenarios, approximately one-half of the peak demand could be served by storage of up to 168 h; but again, the majority of this storage could be with durations of up to 12 h. The potential is also driven by the mix of wind and solar, and by storage efficiency, with the deployment of solar having the largest impact for both storage peaking potential and the mix of durations.

capacity expansion↗

Nanocellulose toward Advanced Energy Storage Devices: Structure and Electrochemistry

We report that cellulose is the most abundant biopolymer on Earth and has long been used as a sustainable building block of conventional paper. Note that nanocellulose accounts for nearly 40% of wood’s weight and can be extracted using well-developed methods. Due to its appealing mechanical and electrochemical properties, including high specific modulus (~100 GPa/(g/cm 3 )), excellent stability in most solvents, and stability over a wide electrochemical window, nanocellulose has been widely used as a separator, electrolyte, binder, and substrate material for energy storage. Additionally, nanocellulose-derived carbon materials have also drawn increasing scientific interest in sustainable energy storage due to their low-cost and raw-material abundance, high conductivity, and rational electrochemical performance. The inexpensive and environmentally friendly nature of nanocellulose and its derivatives as well as simple fabrication techniques make nanocellulose-based energy storage devices promising candidates for the future of “green” and renewable electronics. For nanocellulose-based energy storage, structure engineering and design play a vital role in achieving desired electrochemical properties and performances. Thus, it is important to identify suitable structure and design engineering strategies and to better understand their relationship. In this Account, we review recent developments in nanocellulose-based energy storage. Due to the limited space, we will mainly focus on structure design and engineering strategies in macrofiber, paper, and three-dimensional (3D) structured electrochemical energy storage (EES) devices and highlight progress made in our group. We first present the structure and properties of nanocellulose, with a particular discussion of nanocellulose from wood materials. We then go on to discuss studies on nanocellulose-based macrofiber, paper, and 3D wood- and other aerogel-based EES devices. Within this discussion, we highlight the use of natural nanocellulose as a flexible substrate for a macrofiber supercapacitor and an excellent electrolyte reservoir for a breathable textile lithium–oxygen battery. Paper batteries and supercapacitors using nanocellulose as a green dispersant, nanocellulose-based paper as a flexible substrate, and nanocellulose as separator and electrolyte are also examined. We highlight recent progress on wood-based batteries and supercapacitors, focusing on the advantages of wood materials for energy storage, the structure design and engineering strategies, and their microstructure and electrochemical properties. We discuss the influence of structure (particularly pores) on the electrochemical performance of the energy storage devices. By taking advantage of the straight, nature-made channels in wood materials, ultrathick, highly loaded, and low-tortuosity energy storage devices are demonstrated. Lastly, we offer concluding remarks on the challenges and directions of future research in the field of nanocellulose-based energy storage devices.

25 ENERGY STORAGE↗

Preliminary Component Design and Cost Estimation of a Novel Electric-Thermal Energy Storage System Using Solid Particles

Energy storage will become indispensable to complement the uncertainty of intermittent renewable resources and to firm the electricity supply as renewable power generation becomes the mainstream new-built energy source and fossil fuel power plants are phased out to meet carbon-neutral utility targets. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system is projected to have promising cost and performance characteristics to meet the future growing energy storage needs. This paper introduces the system and components required for particle TES to become technically and economically competitive. The system integrates electric particle heaters, particle TES within insulated concrete silos, and an efficient air-Brayton combined-cycle power system to provide power for storage durations up to several days via low-cost, high-performance storage cycles. Design specifications and cost estimation of major components in a commercial-scale system are presented in this paper. A techno-economic analysis based on preliminary component designs and performance indicates that particle TES integrated with an air-Brayton combined-cycle power system has a path to achieve the targeted levelized cost of storage of 5 ¢/kWh-cycle at a round-trip efficiency of 50% when taking low-cost energy-specific components and leveraging basic assets from existing thermal power plants. The cost model provides insights for further development and economic potentials for long-duration energy storage.

14 SOLAR ENERGY↗

Best Practice for the Commercial Deployment of Carbon Dioxide Geologic Storage: Adaptive Management Approach

The Plains CO 2 Reduction (PCOR) Partnership is one of seven regional partnerships formed as part of the U.S. Department of Energy’s National Energy Technology Laboratory Regional Carbon Sequestration Partnerships (RCSP) Initiative. The RCSP Initiative is focused on the safe and long-term storage of CO 2 to support the commercial deployment of carbon capture and storage (CCS). To that end, the PCOR Partnership has spent over 10 years developing, testing, and validating the best methods and technologies to conduct the geologic storage of CO 2 (hereafter referred to as CO 2 storage). Through this effort, the PCOR Partnership has formalized an adaptive management approach (AMA) for the commercial development of CO 2 storage projects. The use of this approach, which draws upon the collective experience and lessons learned from the PCOR Partnership, represents best practice for advancing CO 2 storage projects toward commercial deployment. At the heart of the AMA are four technical elements necessary for any successful CO 2 storage project: 1) site characterization; 2) modeling and simulation; 3) risk assessment; and 4) monitoring, verification, and accounting (MVA). Each of these elements plays a key role in gathering and assessing site-specific data that provide a fundamental understanding of the storage complex and its performance. While each of the four technical elements can provide useful data independently, integrating them through the AMA yields a streamlined, fit-for-purpose strategy for the commercial deployment of CO 2 storage. Key to this integration and resulting best practice are feedback loops that allow the results of each element to serve as inputs to the others. Each iteration of the AMA creates an improved understanding of the storage complex and thus more targeted and efficient applications of the technical elements. For the purpose of establishing an adaptive management framework, hard lines have been drawn between the technical elements of the AMA. However, in practice, the rapid and seamless interaction between the elements can blur these lines. For example, to aid in the analysis and interpretation of site characterization data, a static geocellular model is often required. While this model development is part of the technical element, modeling and simulation, it is an integral part of the site characterization effort. Likewise, much of the monitoring data collected as part of the MVA technical element can be used to inform site characterization. This back-and-forth flow of data and use of models between the technical elements continues throughout the project.

54 ENVIRONMENTAL SCIENCES↗