Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Metagenomic stable isotope probing reveals bacteriophage participation in soil carbon cycling

Soil viruses are important components of the carbon (C) cycle, yet we still know little about viral ecology in soils. We added diverse 13 C-labelled carbon sources to soil and we used metagenomic-SIP to detect 13 C assimilation by viruses and their putative bacterial hosts. These data allowed us to link a 13 C-labelled bacteriophage to its 13 C-labelled Streptomyces putative host, and we used qPCR to track the dynamics of the putative host and phage in response to C inputs. Following C addition, putative host numbers increased rapidly for 3 days, and then more gradually, reaching maximal abundance on Day 6. Viral abundance and virus:host ratio increased dramatically over 6 days, and remained high thereafter (8.42 ± 2.94). From Days 6 to 30, virus:host ratio remained high, while putative host numbers declined more than 50%. Putative host populations were 13 C-labelled on Days 3–30, while 13 C-labelling of phage was detected on Days 14 and 30. This dynamic suggests rapid growth and 13 C-labelling of the host fueled by new C inputs, followed by extensive host mortality driven by phage lysis. Furthermore, these findings indicate that the viral shunt promotes microbial turnover in soil following new C inputs, thereby altering microbial community dynamics, and facilitating soil organic matter production.

54 ENVIRONMENTAL SCIENCES↗

Contributions of the [NiFe]- and [FeFe]-hydrogenase to H2 production in Shewanella oneidensis MR-1 as revealed by isotope ratio analysis of evolved H2

Shewanella oneidensis MR-1 encodes both a [NiFe]- and an [FeFe]-hydrogenase. While the output of these proteins has been characterized in mutant strains expressing only one of the enzymes, the contribution of each to H2 synthesis in the wild-type organism is not clear. Here we use stable isotope analysis of H2 in the culture headspace, along with transcription data and measurements of the concentrations of gases in the headspace, to characterize H2 production in the wild-type strain. After most of the O2 in the headspace had been consumed, H2 was produced and then consumed by the bidirectional [NiFe]-hydrogenase. Once the cultures were completely anaerobic, a new burst of H2 synthesis catalyzed by both enzymes took place. Our data is consistent with the hypothesis that at this point in the culture cycle, a pool of electrons is shunted toward both hydrogenases in the wild-type organism, but that in the absence of one of the hydrogenases, the flux is redirected to the available enzyme. To our knowledge, this is the first use of stable isotope analysis of a metabolic product to elucidate substrate flux through two alternative enzymes in the same cellular system.

stable isotope, bacteria, metabolism, anaerobic, e↗

Correlations of Cu(In, Ga)Se2 Imaging with Device Performance, Defects, and Microstructural Properties

Camera imaging techniques have been used for the characterization of Cu(In,Ga)Se{sub 2} (CIGS) solar cells. Photoluminescence (PL) imaging shows brightness variations after the deposition of the CIGS layer that persist through CdS deposition and subsequent processing steps to finish the devices. PL and electroluminescence imaging on finished cells show a correlation to the devices corresponding efficiency and open-circuit voltage (V{sub OC}), and dark defect-related spots correspond to bright spots on images from illuminated lock-in thermography (LIT) and forward-bias dark LIT. These image-detected defect areas are weak diodes and shunts. Imaging provides locations of defects detrimental to solar cell performance. Some of these defects are analyzed in more detail by scanning electron microscopy using cross-sectional views.

14 SOLAR ENERGY↗

Investigation of blister formation in sputtered Cu{sub 2}ZnSnS{sub 4} absorbers for thin film solar cells

Blister formation in Cu{sub 2}ZnSnS{sub 4} (CZTS) thin films sputtered from a quaternary compound target is investigated. While the thin film structure, composition, and substrate material are not correlated to the blister formation, a strong link between sputtering gas entrapment, in this case argon, and blistering effect is found. It is shown that argon is trapped in the film during sputtering and migrates to locally form blisters during the high temperature annealing. Blister formation in CZTS absorbers is detrimental for thin film solar cell fabrication causing partial peeling of the absorber layer and potential shunt paths in the complete device. Reduced sputtering gas entrapment, and blister formation, is seen for higher sputtering pressure, higher substrate temperature, and change of sputtering gas to larger atoms. This is all in accordance with previous publications on blister formation caused by sputtering gas entrapment in other materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Periodically pulsed laser-assisted tunneling may generate terahertz radiation

In this work, a mode-locked ultrafast laser focused on the tunneling junction of a scanning tunneling microscope superimposes harmonics of the laser pulse repetition frequency on the direct current tunneling current. The power measured at the first 200 harmonics (up to 14.85 GHz) varies as the inverse square of the frequency due to shunting by the stray capacitance and the resistance in the circuit. However, Fourier analysis suggests that within the tunneling junction there is no significant decay of the harmonics until terahertz frequencies comparable to the reciprocal of the laser pulse-width. Two different types of analysis are used to model the generation of the frequency comb within the tunneling junction. Similar results are obtained, suggesting that the harmonics may extend to terahertz frequencies. Thus, the tunneling junction may be used as a subnanometer sized source of terahertz radiation.

36 MATERIALS SCIENCE↗

Synthesis and electrical behavior of VO 2 thin films grown on SrRuO 3 electrode layers

VO 2 thin films were grown on conducting oxide underlayer SrRuO 3 buffered SrTiO 3 (111) and Si/SiO 2 substrates, respectively, using sputtering. X-ray diffraction phi-scans revealed the epitaxial nature of the VO 2 films grown on SrRuO 3 buffered SrTiO 3 and polycrystalline structure for films grown on SrRuO 3 buffered Si/SiO 2 . X-ray photoelectron spectroscopy confirms a dominant presence of V 4+ in both films and establishes a high-quality growth of single-phase VO 2 films. Temperature and electric-field driven metal-insulator-transition in both the in-plane and out-of-plane configurations were investigated. Depending on the configuration, the resistance change across the metal-insulator-transition varies from a factor of 1.57–3. The measured resistance in each state as well as the magnitude of resistance change were similar during temperature and electric-field driven metal-insulator-transition. To shed light on the suppressed metal-insulator-transition characteristics due to the current shunting effect from conducting SrRuO 3 bottom electrode, a distributed resistance network model is proposed and benchmarked against reports from the literature. Here, the results demonstrate the growth of high-quality VO 2 on conducting SrRuO 3 layers and their electrical behavior, which is of particular interest for all-oxide electronic devices utilizing phase transitions such as resistive memory and neuromorphic oscillators.

36 MATERIALS SCIENCE↗

PV Reliability Determination from I-V Measurement and Analysis

We discuss the measurement and analysis of current vs. voltage (I-V) characteristics of photovoltaic (PV) cells and modules for reliability determination. We discuss both the error sources in the measurements and the strategies to minimize their influence. These error sources include the sample area, spectral errors, temperature fluctuations, current and voltage response time, contacting, and degradation during testing issues. Information that can be extracted from light and dark I-V includes peak power, open-circuit voltage, short-circuit current, series and shunt resistance, diode quality factor, dark current, and photo-current. The quantum efficiency provides information on photo-current nonlinearities, current generation and recombination mechanisms.

14 SOLAR ENERGY↗

Accurate Measurement of Organic Solar Cell Efficiency

We discuss the measurement and analysis of current vs. voltage (I-V) characteristics of organic and dye-sensitized photovoltaic cells and modules. A brief discussion of the history of photovoltaic efficiency measurements and procedures will be presented. We discuss both the error sources in the measurements and the strategies to minimize their influence. These error sources include the sample area, spectral errors, temperature fluctuations, current and voltage response time, contacting, and degradation during testing. Information that can be extracted from light and dark I-V measurement includes peak power, open-circuit voltage, short-circuit current, series and shunt resistance, diode quality factor, dark current, and photo-current. The quantum efficiency provides information on photo-current nonlinearities, current generation, and recombination mechanisms.

14 SOLAR ENERGY↗

The design of a simulated in-line side-coupled 6 MV linear accelerator waveguide

Purpose: The design of a 3D in-line side-coupled 6 MV linac waveguide for medical use is given, and the effect of the side-coupling and port irises on the radio frequency (RF), beam dynamics, and dosimetric solutions is examined. This work was motivated by our research on a linac-MR hybrid system, where accurate electron trajectory information for a clinical medical waveguide in the presence of an external magnetic field was needed. Methods: For this work, the design of the linac waveguide was generated using the finite element method. The design outlined here incorporates the necessary geometric changes needed to incorporate a full-end accelerating cavity with a single-coupling iris, a waveguide-cavity coupling port iris that allows power transfer into the waveguide from the magnetron, as well as a method to control the RF field magnitude within the first half accelerating cavity into which the electrons from the gun are injected. Results: With the full waveguide designed to resonate at 2998.5{+-}0.1 MHz, a full 3D RF field solution was obtained. The accuracy of the 3D RF field solution was estimated through a comparison of important linac parameters (Q factor, shunt impedance, transit time factor, and resonant frequency) calculated for one accelerating cavity with the benchmarked program SUPERFISH. It was found that the maximum difference between the 3D solution and SUPERFISH was less than 0.03%. The eigenvalue solver, which determines the resonant frequencies of the 3D side-coupled waveguide simulation, was shown to be highly accurate through a comparison with lumped circuit theory. Two different waveguide geometries were examined, one incorporating a 0.5 mm first side cavity shift and another with a 1.5 mm first side cavity shift. The asymmetrically placed side-coupling irises and the port iris for both models were shown to introduce asymmetries in the RF field large enough to cause a peak shift and skewing (center of gravity minus peak shift) of an initially cylindrically uniform electron beam accelerating within the waveguide. The shifting and skewing of the electron beam were found to be greatest due to the effects of the side-coupling irises on the RF field. A further Monte Carlo study showed that this effect translated into a 1% asymmetry in a 40x40 cm{sup 2} field dose profile. Conclusions: A full 3D design for an in-line side-coupled 6 MV linear accelerator that emulates a common commercial waveguide has been given. The effect of the side coupling on the dose distribution has been shown to create a slight asymmetry, but overall does not affect the clinical applicability of the linac. The 3D in-line side-coupled linac model further provides a tool for the investigation of linac performance within an external magnetic field, which exists in an integrated linac-MR system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of conversion factors for effective dose for various interventional radiology procedures

Purpose: To provide dose-area-product (DAP) to effective dose (E) conversion factors for complete interventional procedures, based on in-the-field clinical measurements of DAP values and using tabulated E/DAP conversion factors for single projections available from the literature. Methods: Nine types of interventional procedures were performed on 84 patients with two angiographic systems. Different calibration curves (with and without patient table attenuation) were calculated for each DAP meter. Clinical and dosimetric parameters were recorded in-the-field for each projection and for all patients, and a conversion factor linking DAP and effective doses was derived for each complete procedure making use of published, Monte Carlo calculated conversion factors for single static projections. Results: Fluoroscopy time and DAP values for the lowest-dose procedure (biliary drainage) were approximately 3-fold and 13-fold lower, respectively, than those for the highest-dose examination (transjugular intrahepatic portosystemic shunt, TIPS). Median E/DAP conversion factors from 0.12 (abdominal percutaneous transluminal angioplasty) to 0.25 (Nephrostomy) mSvGy{sup -1} cm{sup -2} were obtained and good correlations between E and DAP were found for all procedures, with R{sup 2} coefficients ranging from 0.80 (abdominal angiography) to 0.99 (biliary stent insertion, Nephrostomy and TIPS). The DAP values obtained in this study showed general consistency with the values provided in the literature and median E values ranged from 4.0 mSv (biliary drainage) to 49.6 mSv (TIPS). Conclusions: Values of E/DAP conversion factors were derived for each procedure from a comprehensive analysis of projection and dosimetric data: they could provide a good evaluation for the stochastic effects. These results can be obtained by means of a close cooperation between different interventional professionals involved in patient care and dose optimization.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beam generation and planar imaging at energies below 2.40 MeV with carbon and aluminum linear accelerator targets

Purpose: Recent work has demonstrated improvement of image quality with low-Z linear accelerator targets and energies as low as 3.5 MV. In this paper, the authors lower the incident electron beam energy between 1.90 and 2.35 MeV and assess the improvement of megavoltage planar image quality with the use of carbon and aluminum linear accelerator targets. Methods: The bending magnet shunt current was adjusted in a Varian linear accelerator to allow selection of mean electron energy between 1.90 and 2.35 MeV. Linac set points were altered to increase beam current to allow experimental imaging in a practical time frame. Electron energy was determined through comparison of measured and Monte Carlo modeled depth dose curves. Planar image CNR and spatial resolution measurements were performed to quantify the improvement of image quality. Magnitudes of improvement are explained with reference to Monte Carlo generated energy spectra. Results: After modifications to the linac, beam current was increased by a factor greater than four and incident electron energy was determined to have an adjustable range from 1.90 MeV to 2.35 MeV. CNR of cortical bone was increased by a factor ranging from 6.2 to 7.4 and 3.7 to 4.3 for thin and thick phantoms, respectively, compared to a 6 MV therapeutic beam for both aluminum and carbon targets. Spatial resolution was degraded slightly, with a relative change of 3% and 10% at 0.20 lp/mm and 0.40 lp/mm, respectively, when reducing energy from 2.35 to 1.90 MV. The percentage of diagnostic x-rays for the beams examined here, ranges from 46% to 54%.Conclusion: It is possible to produce a large fraction of diagnostic energy x-rays by lowering the beam energy below 2.35 MV. By lowering the beam energy to 1.90 MV or 2.35 MV, CNR improves by factors ranging from 3.7 to 7.4 compared to a 6 MV therapy beam, with only a slight degradation of spatial resolution when lowering the energy from 2.35 MV to 1.90 MV.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-116: Dose Response in the Treatment of Unresectable Cholangiocarcinoma with Yttrium-90 Microspheres

Purpose: The purpose of this study is to assess the dose response of radioembolization using yttrium-90 (Y-90) microspheres in patients treated for unresectable cholangiocarcinoma. This study utilized partition dosimetry model for the dose calculation. The results show survival benefit with dose escalation. Methods: Between February 2009 and March 2013, ten patients with pathology proven unresectable cholangiocarcinoma were radioembolized with Y-90 microspheres. Patients underwent initial pre-treatment angiographic assessment for blood flow and 99mTc- MAA for lung shunt evaluation. Activity of Y-90 administration was calculated using the Body Surface Area (BSA) and target volumes which were determined by contouring the pre-treatment MRI/CT images using a radiation therapy treatment planning system. Medical Internal Radiation Dose (MIRD) method was used to assess the dosimetric results of Y90. Partition model based on the tumor to-liver activity uptake estimated from pretreatment 99mTc- MAA study was used to calculate the dose delivered to the target. The variables assessed included: administered dose, toxicity based on clinical changes, imaging based tumor response, and survival. Results: Ten patients were radioembolized with Y-90 microspheres to either one hepatic lobe or both left and right lobes. Patients were stratified by dose. Four patients who received dose greater than 140Gy (p < 0.05) all survived. The corresponding activity they received was greater than 35 mCi. Six out of ten patients died of disease with median survival of 18 weeks (range 12–81wks). Conclusion: Given the growing body of data for Y-90 microspheres in the context of cholangiocarcinoma, radioembolization may become an important treatment modality for an appropriately selected group of patients. Our study further substantiates past studies and shows additional evidence of a survival benefit with dose escalation.

60 APPLIED LIFE SCIENCES↗

MO-G-17A-06: Kernel Based Dosimetry for 90Y Microsphere Liver Therapy Using 90Y Bremsstrahlung SPECT/CT

Purpose: 90Y microsphere therapy in liver presents a situation where beta transport is dominant and the tissue is relatively homogenous. We compare voxel-based absorbed doses from a 90Y kernel to Monte Carlo (MC) using quantitative 90Y bremsstrahlung SPECT/CT as source distribution. Methods: Liver, normal liver, and tumors were delineated by an interventional radiologist using contrast-enhanced CT registered with 90Y SPECT/CT scans for 14 therapies. Right lung was segmented via region growing. The kernel was generated with 1.04 g/cc soft tissue for 4.8 mm voxel matching the SPECT. MC simulation materials included air, lung, soft tissue, and bone with varying densities. We report percent difference between kernel and MC (%Δ(K,MC)) for mean absorbed dose, D70, and V20Gy in total liver, normal liver, tumors, and right lung. We also report %Δ(K,MC) for heterogeneity metrics: coefficient of variation (COV) and D10/D90. The impact of spatial resolution (0, 10, 20 mm FWHM) and lung shunt fraction (LSF) (1,5,10,20%) on the accuracy of MC and kernel doses near the liver-lung interface was modeled in 1D. We report the distance from the interface where errors become <10% of unblurred MC as d10(side of interface, dose calculation, FWHM blurring, LSF). Results: The %Δ(K,MC) for mean, D70, and V20Gy in tumor and liver was <7% while right lung differences varied from 60–90%. The %Δ(K,MC) for COV was <4.8% for tumor and liver and <54% for the right lung. The %Δ(K,MC) for D10/D90 was <5% for 22/23 tumors. d10(liver,MC,10,1–20) awere <9mm and d10(liver,MC,20,1–20) awere <15mm; both agreed within 3mm to the kernel. d10(lung,MC,10,20), d10(lung,MC,10,1), d10(lung,MC,20,20), and d10(lung,MC,20,1) awere 6, 25, 15, and 34mm, respectively. Kernel calculations on blurred distributions in lung had errors > 10%. Conclusions: Liver and tumor voxel doses with 90Y kernel and MC agree within 7%. Large differences exist between the two methods in right lung. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-08: New Compact 10 MV S-Band Linear Accelerator: 3D Finite-Element Design and Monte Carlo Dose Simulations

Purpose: To design a new compact S-band linac waveguide capable of producing a 10 MV x-ray beam, while maintaining the length (27.5 cm) of current 6 MV waveguides. This will allow higher x-ray energies to be used in our linac-MRI systems with the same footprint. Methods: Finite element software COMSOL Multiphysics was used to design an accelerator cavity matching one published in an experiment breakdown study, to ensure that our modeled cavities do not exceed the threshold electric fields published. This cavity was used as the basis for designing an accelerator waveguide, where each cavity of the full waveguide was tuned to resonate at 2.997 GHz by adjusting the cavity diameter. The RF field solution within the waveguide was calculated, and together with an electron-gun phase space generated using Opera3D/SCALA, were input into electron tracking software PARMELA to compute the electron phase space striking the x-ray target. This target phase space was then used in BEAM Monte Carlo simulations to generate percent depth doses curves for this new linac, which were then used to re-optimize the waveguide geometry. Results: The shunt impedance, Q-factor, and peak-to-mean electric field ratio were matched to those published for the breakdown study to within 0.1% error. After tuning the full waveguide, the peak surface fields are calculated to be 207 MV/m, 13% below the breakdown threshold, and a d-max depth of 2.42 cm, a D10/20 value of 1.59, compared to 2.45 cm and 1.59, respectively, for the simulated Varian 10 MV linac and brehmsstrahlung production efficiency 20% lower than a simulated Varian 10 MV linac. Conclusion: This work demonstrates the design of a functional 27.5 cm waveguide producing 10 MV photons with characteristics similar to a Varian 10 MV linac.

07 ISOTOPE AND RADIATION SOURCES↗

Design and validation of an MR-conditional robot for transcranial focused ultrasound surgery in infants

Purpose: Current treatment of intraventricular hemorrhage (IVH) involves cerebral shunt placement or an invasive brain surgery. Magnetic resonance-guided focused ultrasound (MRgFUS) applied to the brains of pediatric patients presents an opportunity to treat IVH in a noninvasive manner, termed “incision-less surgery.” Current clinical and research focused ultrasound systems lack the capability to perform neonatal transcranial surgeries due to either range of motion or dexterity requirements. A novel robotic system is proposed to position a focused ultrasound transducer accurately above the head of a neonatal patient inside an MRI machine to deliver the therapy. Methods: A clinical Philips Sonalleve MRgFUS system was expanded to perform transcranial treatment. A five degree-of-freedom MR-conditional robot was designed and manufactured using MR compatible materials. The robot electronics and control were integrated into existing Philips electronics and software interfaces. The user commands the position of the robot with a graphical user interface, and is presented with real-time MR imaging of the patient throughout the surgery. The robot is validated through a series of experiments that characterize accuracy, signal-to-noise ratio degeneration of an MR image as a result of the robot, MR imaging artifacts generated by the robot, and the robot’s ability to operate in a representative surgical environment inside an MR machine. Results: Experimental results show the robot responds reliably within an MR environment, has achieved 0.59 ± 0.25 mm accuracy, does not produce severe MR-imaging artifacts, has a workspace providing sufficient coverage of a neonatal brain, and can manipulate a 5 kg payload. A full system demonstration shows these characteristics apply in an application environment. Conclusions: This paper presents a comprehensive look at the process of designing and validating a new robot from concept to implementation for use in an MR environment. An MR conditional robot has been designed and manufactured to design specifications. The system has demonstrated its feasibility as a platform for MRgFUS interventions for neonatal patients. The success of the system in experimental trials suggests that it is ready to be used for validation of the transcranial intervention in animal studies.

60 APPLIED LIFE SCIENCES↗

SU-F-T-687: Comparison of SPECT/CT-Based Methodologies for Estimating Lung Dose from Y-90 Radioembolization

Purpose: To compare mean lung dose (MLD) estimates from 99mTc macroaggregated albumin (MAA) SPECT/CT using two published methodologies for patients treated with {sup 90}Y radioembolization for liver cancer. Methods: MLD was estimated retrospectively using two methodologies for 40 patients from SPECT/CT images of 99mTc-MAA administered prior to radioembolization. In these two methods, lung shunt fractions (LSFs) were calculated as the ratio of scanned lung activity to the activity in the entire scan volume or to the sum of activity in the lung and liver respectively. Misregistration of liver activity into the lungs during SPECT acquisition was overcome by excluding lung counts within either 2 or 1.5 cm of the diaphragm apex respectively. Patient lung density was assumed to be 0.3 g/cm{sup 3} or derived from CT densitovolumetry respectively. Results from both approaches were compared to MLD determined by planar scintigraphy (PS). The effect of patient size on the difference between MLD from PS and SPECT/CT was also investigated. Results: Lung density from CT densitovolumetry is not different from the reference density (p = 0.68). The second method resulted in lung dose of an average 1.5 times larger lung dose compared to the first method; however the difference between the means of the two estimates was not significant (p = 0.07). Lung dose from both methods were statistically different from those estimated from 2D PS (p < 0.001). There was no correlation between patient size and the difference between MLD from PS and both SPECT/CT methods (r < 0.22, p > 0.17). Conclusion: There is no statistically significant difference between MLD estimated from the two techniques. Both methods are statistically different from conventional PS, with PS overestimating dose by a factor of three or larger. The difference between lung doses estimated from 2D planar or 3D SPECT/CT is not dependent on patient size.

60 APPLIED LIFE SCIENCES↗

Proteomic Analysis of Stationary Phase in the Marine Bacterium "Candidatus Pelagibacter ubique"

The α-proteobacterium ‘Candidatus Pelagibacter ubique’ str. HTCC1062, and most other members of the SAR11 clade, lack genes for assimilatory sulfate reduction, making them dependent on organosulfur compounds that occur naturally in seawater. To investigate how these cells adapt to sulfur limitation, batch cultures were grown in defined media containing either limiting or non-limiting amounts of dimethylsulfoniopropionate (DMSP) as the sole sulfur source. Protein and mRNA expression were measured during exponential growth, immediately prior to stationary phase, and in late stationary phase. Two distinct responses were observed: one as DMSP became exhausted, and another as cells acclimated to a sulfur-limited environment. The first response was characterized by increased transcription and translation of all Ca. P. ubique genes downstream of previously confirmed S-adenosyl methionine (SAM) riboswitches: bhmT, mmuM, and metY. Proteins encoded by these genes were up to 33 times more abundant as DMSP became limiting. Their predicted function is to shunt all available sulfur to methionine. The secondary response, observed during sulfur-depleted stationary phase, was a 6-10 fold increase in transcription of the heme c shuttle ccmC and two small genes of unknown function (SAR11_1163 and SAR11_1164). This bacterium's strategy for coping with sulfur stress appears to be intracellular redistribution to support methionine biosynthesis, rather than increasing organosulfur import. Many of the genes and SAM riboswitches involved in this response are located in a hypervariable genome region (HVR). One of these HVR genes, ordL, is located downstream of a conserved motif that evidence suggests is a novel riboswitch.

59 BASIC BIOLOGICAL SCIENCES↗

Functional Analysis of H + -Pumping Membrane-Bound Pyrophosphatase, ADP-Glucose Synthase, and Pyruvate Phosphate Dikinase as Pyrophosphate Sources in Clostridium thermocellum

Increased understanding of the central metabolism of C. thermocellum is important from a fundamental as well as from a sustainability and industrial perspective. In addition to showing that H + -pumping membrane-bound PPase, glycogen cycling, a Ppdk–malate shunt cycle, and acetate cycling are not significant sources of PP i supply, this study adds functional annotation of four genes and availability of an updated PP i stoichiometry from biosynthesis to the scientific domain.

Clostridium thermocellum↗