Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner

Treatment of small animals with radiation has in general been limited to planar fields shaped with lead blocks, complicating spatial localization of dose and treatment of deep-seated targets. In order to advance laboratory radiotherapy toward what is accomplished in the clinic, we have constructed a variable aperture collimator for use in shaping the beam of microCT scanner. This unit can image small animal subjects at high resolution, and is capable of delivering therapeutic doses in reasonable exposure times. The proposed collimator consists of two stages, each containing six trapezoidal brass blocks that move along a frame in a manner similar to a camera iris producing a hexagonal aperture of variable size. The two stages are offset by 30 deg. and adjusted for the divergence of the x-ray beam so as to produce a dodecagonal profile at isocenter. Slotted rotating driving plates are used to apply force to pins in the collimator blocks and effect collimator motion. This device has been investigated through both simulation and measurement. The collimator aperture size varied from 0 to 8.5 cm as the driving plate angle increased from 0 to 41 deg. . The torque required to adjust the collimator varied from 0.5 to 5 N{center_dot}m, increasing with increasing driving plate angle. The transmission profiles produced by the scanner at isocenter exhibited a penumbra of approximately 10% of the collimator aperture width. Misalignment between the collimator assembly and the x-ray source could be identified on the transmission images and corrected by adjustment of the collimator location. This variable aperture collimator technology is therefore a feasible and flexible solution for adjustable shaping of radiation beams for use in small animal radiotherapy as well as other applications in which beam shaping is desired.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of fixed-beam IMRT, helical tomotherapy, and IMPT for selected cases

A growing number of advanced intensity modulated treatment techniques is becoming available. In this study, the specific strengths and weaknesses of four techniques, static and dynamic multileaf collimator (MLC), conventional linac-based IMRT, helical tomotherapy (HT), and spot-scanning proton therapy (IMPT) are investigated in the framework of biological, EUD-based dose optimization. All techniques were implemented in the same in-house dose optimization tool. Monte Carlo dose computation was used in all cases. All dose-limiting, normal tissue objectives were treated as hard constraints so as to facilitate comparability. Five patient cases were selected to offer each technique a chance to show its strengths: a deep-seated prostate case (for 15 MV linac-based IMRT), a pediatric case (for IMPT), an extensive head-and-neck case (for HT), a lung tumor (for HT), and an optical neurinoma (for noncoplanar linac-based IMRT with a miniMLC). The plans were compared by dose statistics and equivalent uniform dose metrics. All techniques delivered results that were comparable with respect to target coverage and the most dose-limiting normal tissues. Static MLC IMRT struggled to achieve sufficient target coverage at the same level of dose homogeneity in the lung case. IMPT gained the greatest advantage when lung sparing was important, but did not significantly reduce the risk of nearby organs. Tomotherapy and dynamic MLC IMRT showed mostly the same performance. Despite the apparent conceptual differences, all four techniques fare equally well for standard patient cases. The absence of relevant differences is in part due to biological optimization, which offers more freedom to shape the dose than do, e.g., dose volume histogram constraints. Each technique excels for certain classes of highly complex cases, and hence the various modalities should be viewed as complementary, rather than competing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose and dose averaged LET comparison of {sup 1}H, {sup 4}He, {sup 6}Li, {sup 8}Be, {sup 10}B, {sup 12}C, {sup 14}N, and {sup 16}O ion beams forming a spread-out Bragg peak

Purpose: Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams ({sup 1}H, {sup 4}He, {sup 6}Li, {sup 8}Be, {sup 10}B, {sup 12}C, {sup 14}N, and {sup 16}O) using multi-energetic spectra in order to configure spread-out Bragg peaks (SOBP). Methods: Monte Carlo simulations were performed in order to configure a 5 cm SOBP at 8 cm depth in water for all the different ion beams. Physical dose and dose averaged LET distributions as a function of depth were then calculated and compared. The superposition of dose distribution of all ions is also presented for a two opposing fields configuration. Additional simulations were performed for {sup 12}C beams to investigate the dependence of dose and dose averaged LET distributions on target depth and size, as well as beam configuration. These included simulations for a 3 cm SOBP at 7, 10, and 13 cm depth in water, a 6 cm SOBP at 7 depth in water, and two opposing fields of 6 cm SOBP. Results: Alpha particles and protons present superior physical depth dose distributions relative to the rest of the beams studied. Dose averaged LET distributions results suggest higher biological effectiveness in the target volume for carbon, nitrogen and oxygen ions. This is coupled, however, with relatively high LET values--especially for the last two ion species--outside the SOBP where healthy tissue would be located. Dose averaged LET distributions for {sup 8}Be and {sup 10}B beams show that they could be attractive alternatives to {sup 12}C for the treatment of small, not deeply seated lesions. The potential therapeutic effect of different ion beams studied in this work depends on target volume and position, as well as the number of beams used. Conclusions: The optimization of beam modality for specific tumor cites remains an open question that warrants further investigation and clinically relevant results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator

Purpose: To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. Methods: In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. Results: It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. Conclusions: The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-186: Acquiring and Assessing Upright CBCT Images for Future Treatment Planning

Purpose: To acquire upright CBCT images using the onboard imager of a Varian TrueBeam. An easy to implement upright imaging protocol could allow for widespread upright radiation therapy which would greatly benefit certain patients. These include thoracic cancer patients (because lung volume increases in a seated position) and patients who experience substantial discomfort during supine treatment. Methods: To acquire upright CBCT images, the gantry head remained stationary at 0 degrees with the KV imager arms extended to their lateral positions. Phantoms were placed upright at the end of the treatment couch. During a scan, the couch rotated from 270 to 90 degrees while continuous fluoroscopic projections were taken by the onboard imager. To extend the field-of-view, this sequence was performed twice: once with the KV detector longitudinally offset +14.5cm and once with it longitudinally offset −14.5cm. The resulting two image sets were stitched together before reconstruction. The imaging beam parameters were chosen to deliver a dose similar to that given during a simulation CT. Image quality was evaluated for spatial linearity, high and low contrast resolution, and HU linearity using CatPhan and anthropomorphic phantoms. A deformable registration technique was used to evaluate HU mapping from a simulation CT. Results: Spatial linearity and high contrast resolution were maintained in upright CBCT when compared to simulation CT. However, low contrast resolution and HU linearity degraded. Streak artifacts were caused by the limited 180 degree arc of the couch, and the stitching process created a sharp artifact at the center of the reconstruction. The deformable registration was robust in the HU mapping even with these artifacts and the loss of HU linearity. Conclusions: The image quality obtained from upright CBCT was sufficient for treatment planning. The success of this novel technique is an important step towards a future clinical protocol. This project was funded in part by Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-273: Radiation Shielding for a Fixed Horizontal-Beam Linac in a Shipping Container and a Conventional Treatment Vault

Purpose: A fixed horizontal-beam linac, where the patient is treated in a seated position, could lower the overall costs of the treatment unit and room shielding substantially. This design also allows the treatment room and control area to be contained within a reduced space, such as a shipping container. The main application is the introduction of low-cost, high-quality radiation therapy to low- and middle-income regions. Here we consider shielding for upright treatments with a fixed-6MV-beam linac in a shipping container and a conventional treatment vault. Methods: Shielding calculations were done for two treatment room layouts using calculation methods in NCRP Report 151: (1) a shipping container (6m × 2.4m with the remaining space occupied by the console area), and (2) the treatment vault in NCRP 151 (7.8m by 5.4m by 3.4m). The shipping container has a fixed gantry that points in one direction at all times. For the treatment vault, various beam directions were evaluated. Results: The shipping container requires a primary barrier of 168cm concrete (4.5 TVL), surrounded by a secondary barrier of 3.6 TVL. The other walls require between 2.8–3.3 TVL. Multiple shielding calculations were done along the side wall. The results show that patient scatter increases in the forward direction and decreases dramatically in the backward direction. Leakage scatter also varies along the wall, depending largely on the distance between the gantry and the wall. For the treatment room, fixed-beam requires a slightly thicker primary barrier than the conventional linac (0.6 TVL), although this barrier is only needed in the center of one wall. The secondary barrier is different only by 0–0.2 TVL. Conclusion: This work shows that (1) the shipping container option is achievable, using indigenous materials for shielding and (2) upright treatments can be performed in a conventional treatment room with minimal additional shielding. Varian Medical Systems.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-381: Radio-Dynamic Therapy (RDT) for the Treatment of Late-Stage Cancers

Purpose: Photo-dynamic therapy (PDT) is an effective treatment modality because of the preferential absorption of photosensitizing agent in tumor cells than in surrounding normal tissues. A limitation of PDT for cancer therapy is the finite penetration of laser light to activate the targeting agent in deep-seated tumors. Radio-dynamic therapy (RDT) is designed to overcome this problem by the combination of high-energy (up to 45MV) photon beams and photo/radio-sensitizers. This work investigates the feasibility of PDT for late-stage cancer patients who are no longer respond to conventional therapies available. Methods: The high-energy photon beams are generated using a LA45 RaceTrack Microtron (Top Grade Medical, Beijing, China). The targeting agent investigated is 5- aminolevulinic acid (5-ALA). Both in vitro cell lines and in vivo animal models have been used to investigate the mechanisms of RDT and its therapeutic effects and normal tissue toxicities. Oral 5-ALA (30-60 mg/kg) was administered 4-6 hours before the radiation treatment and the total radiation dose varied between 0.1-4.0Gy in 1-4 fractions. Clinical trials are initiated in China for late-stage cancer patients targeting both primary tumors utilizing localized therapies such as 3DCRT/IMRT and metastases using TBI. Results: There is clear correlation between the cell death and the 5-ALA concentration/radiation dose. The therapeutic effect of RDT is demonstrated using an animal model where the volume of parotid tumors for the RT only group continued to grow after 3Gy irradiation while the RDT group showed a complete response with the same radiation dose. The preliminary clinical results showed encouraging clinical outcome. Conclusion: RDT is a novel treatment technique that may be developed into an effective cancer treatment modality. Further studies on the mechanisms of RDT and its potential clinical applications are warranted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-479: Development and Validation of Analytical Models Predicting Secondary Neutron Radiation in Proton Therapy Applications

Purpose: Test and validation of analytical models predicting leakage neutron exposure in passively scattered proton therapy. Methods: Taking inspiration from the literature, this work attempts to build an analytical model predicting neutron ambient dose equivalents, H*(10), within the local 75 MeV ocular proton therapy facility. MC simulations were first used to model H*(10) in the beam axis plane while considering a closed final collimator and pristine Bragg peak delivery. Next, MC-based analytical model was tested against simulation results and experimental measurements. The model was also expended in the vertical direction to enable a full 3D mapping of H*(10) inside the treatment room. Finally, the work focused on upgrading the literature model to clinically relevant configurations considering modulated beams, open collimators, patient-induced neutron fluctuations, etc. Results: The MC-based analytical model efficiently reproduced simulated H*(10) values with a maximum difference below 10%. In addition, it succeeded in predicting measured H*(10) values with differences <40%. The highest differences were registered at the closest and farthest positions from isocenter where the analytical model failed to faithfully reproduce the high neutron fluence and energy variations. The differences remains however acceptable taking into account the high measurement/simulation uncertainties and the end use of this model, i.e. radiation protection. Moreover, the model was successfully (differences < 20% on simulations and < 45% on measurements) extended to predict neutrons in the vertical direction with respect to the beam line as patients are in the upright seated position during ocular treatments. Accounting for the impact of beam modulation, collimation and the present of a patient in the beam path is far more challenging and conversion coefficients are currently being defined to predict stray neutrons in clinically representative treatment configurations. Conclusion: Analytical models predicting secondary neutrons in proton therapy represent a promising solution that substitute for time-consuming MC calculations.

60 APPLIED LIFE SCIENCES↗

SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains one of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been successfully evaluated for its ability to provide sufficient hyperthermia in clinically-realistic implants. This work was partially supported by the National Institutes of Health (NIH) STTR Grant No. R41 CA153631-01A1.

60 APPLIED LIFE SCIENCES↗

WE-G-BRE-01: A High Power Nanotube X-Ray Microbeam Irradiator for Preclinical Brain Tumor Treatment

Purpose: Microbeam radiation therapy (MRT) is a new type of cancer treatment undergoing studies at various synchrotron facilities. The principle of MRT is using arrays of microscopically small, low-energy X-radiation for the treatment of various radio-resistant, deep-seated tumors. Our motivation is to develop a compact and inexpensive image guided MRT irradiator to use in the research lab setting. After a successful initial demonstration, here we report a second generation carbon nanotube (CNT) cathode based MRT tube, capable of producing multiple microbeam lines with an anticipated dose rate of 11 Gy/min per line. Methods: The system uses multiple line CNT source arrays to generate multiple focal lines on the anode. The increase in dose-rate, compared to our first generation system, is achieved by increasing the operating voltage from 160 kVp to 225kVp, adding multiple simultaneous focal lines on the anode, and a more efficient cooling mechanism using a 6kW oil-cooled anode. Results: This work will present the design and development process, challenges and solutions to meeting operating specifications, and the final design of the tube and collimator, along with optimization and stabilization of its use. A detailed characterization of its capabilities will be included with a comprehensive measurement of its X-ray focal line dimensions, an evaluation of its collimator alignment and microbeam dimensions, and phantom-based quantification of its dosimetric output. Conclusion: The development of a second generation, compact, multiple line MRT device using carbon nanotube (CNT) cathode based X-ray technology and a novel oil cooled anode design is presented here. With this new source, we are capable of delivering a total microbeam radiation dose comparable to the low end of the synchrotron based MRT systems for small animal brain tumor models.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 04: Gold Nanoparticle Enhanced Arc Radiotherapy: A Monte Carlo Feasibility Study

Introduction: The use of gold nanoparticles (GNPs) in radiotherapy has shown promise for therapeutic enhancement. In this study, we explore the feasibility of enhancing radiotherapy with GNPs in an arc-therapy context. We use Monte Carlo simulations to quantify the macroscopic dose-enhancement ratio (DER) and tumour to normal tissue ratio (TNTR) as functions of photon energy over various tumour and body geometries. Methods: GNP-enhanced arc radiotherapy (GEART) was simulated using the PENELOPE Monte Carlo code and penEasy main program. We simulated 360° arc-therapy with monoenergetic photon energies 50 – 1000 keV and several clinical spectra used to treat a spherical tumour containing uniformly distributed GNPs in a cylindrical tissue phantom. Various geometries were used to simulate different tumour sizes and depths. Voxel dose was used to calculate DERs and TNTRs. Inhomogeneity effects were examined through skull dose in brain tumour treatment simulations. Results: Below 100 keV, DERs greater than 2.0 were observed. Compared to 6 MV, tumour dose at low energies was more conformai, with lower normal tissue dose and higher TNTRs. Both the DER and TNTR increased with increasing cylinder radius and decreasing tumour radius. The inclusion of bone showed excellent tumour conformality at low energies, though with an increase in skull dose (40% of tumour dose with 100 keV compared to 25% with 6 MV). Conclusions: Even in the presence of inhomogeneities, our results show promise for the treatment of deep-seated tumours with low-energy GEART, with greater tumour dose conformality and lower normal tissue dose than 6 MV.

60 APPLIED LIFE SCIENCES↗

Dosimetric evaluation of new approaches in GRID therapy using nonconventional radiation sources

Purpose: Spatial fractionation of the dose has proven to be a promising approach to increase the tolerance of healthy tissue, which is the main limitation of radiotherapy. A good example of that is GRID therapy, which has been successfully used in the management of large tumors with low toxicity. The aim of this work is to explore new avenues using nonconventional sources: GRID therapy by using kilovoltage (synchrotron) x-rays, the use of very high-energy electrons, and proton GRID therapy. They share in common the use of the smallest possible grid sizes in order to exploit the dose–volume effects. Methods: Monte Carlo simulations (PENELOPE/PENEASY and GEANT4/GATE codes) were used as a method to study dose distributions resulting from irradiations in different configurations of the three proposed techniques. As figure of merit, percentage (peak and valley) depth dose curves, penumbras, and central peak-to-valley dose ratios (PVDR) were evaluated. As shown in previous biological experiments, high PVDR values are requested for healthy tissue sparing. A superior tumor control may benefit from a lower PVDR. Results: High PVDR values were obtained in the healthy tissue for the three cases studied. When low energy photons are used, the treatment of deep-seated tumors can still be performed with submillimetric grid sizes. Superior PVDR values were reached with the other two approaches in the first centimeters along the beam path. The use of protons has the advantage of delivering a uniform dose distribution in the tumor, while healthy tissue benefits from the spatial fractionation of the dose. In the three evaluated techniques, there is a net reduction in penumbra with respect to radiosurgery. Conclusions: The high PVDR values in the healthy tissue and the use of small grid sizes in the three presented approaches might constitute a promising alternative to treat tumors with such spatially fractionated radiotherapy techniques. The dosimetric results presented here support the interest of performing radiobiology experiments in order to evaluate these new avenues.

07 ISOTOPE AND RADIATION SOURCES↗

WE-A-207-00: In Memoriam of Jacques Ovadia - Reinvigorating Scientific Excellence: Electron Beam Therapy - Past, Present and Future

The Medical Physics community lost one of its early pioneers in radiation oncology physics, Jacques Ovadia, who passed away in April of 2014 at the age of 90. Jacques received his Ph.D. in Nuclear Physics from the University of Illinois at Urbana in 1951. Subsequently, under the guidance of John Laughlin, he was introduced to the field of Medical Physics. When John moved to Memorial Sloan Kettering, Jacques followed him. There he gained clinical experience and expertise in the then cutting-edge field of high energy electron beam therapy. In 1956, Jacques joined Dr. Erich Uhlmann at Michael Reese Hospital in Chicago where one of the country’s first high energy medical linear accelerators had just been installed. During his 35 year tenure, Dr. Ovadia built a strong Medical Physics department that merged in 1984 with that of the University of Chicago. Jacques pioneered the use of high energy electron beams to treat deep seated tumors, multiple-field chest wall irradiation with variable electron energies, and even anticipated the current interest in high energy electron beam grid-therapy. At an early stage, he introduced a simulator, computerized treatment planning and in-house developed record and verify software. He retired in 1990 as Professor emeritus in Radiation and Cellular Biology at the University of Chicago. Dr. Ovadia was an early and strong supporter of AAPM. He was present at the Chicago ROMPS meeting where the decision was made to form an independent professional society for medical physics. He served as AAPM president in 1976. Jacques Ovadia is survived by his wife of 58 years, Florence, their daughter Corinne Graefe and son Marc Ovadia, MD, as well as four grandchildren and one great-grandchild. Jacques’ dynamic and ever enthusiastic personality inspired all who collaborated with him. He will be greatly missed.

60 APPLIED LIFE SCIENCES↗

WE-A-207-01: Memorial Lecturer

The Medical Physics community lost one of its early pioneers in radiation oncology physics, Jacques Ovadia, who passed away in April of 2014 at the age of 90. Jacques received his Ph.D. in Nuclear Physics from the University of Illinois at Urbana in 1951. Subsequently, under the guidance of John Laughlin, he was introduced to the field of Medical Physics. When John moved to Memorial Sloan Kettering, Jacques followed him. There he gained clinical experience and expertise in the then cutting-edge field of high energy electron beam therapy. In 1956, Jacques joined Dr. Erich Uhlmann at Michael Reese Hospital in Chicago where one of the country’s first high energy medical linear accelerators had just been installed. During his 35 year tenure, Dr. Ovadia built a strong Medical Physics department that merged in 1984 with that of the University of Chicago. Jacques pioneered the use of high energy electron beams to treat deep seated tumors, multiple-field chest wall irradiation with variable electron energies, and even anticipated the current interest in high energy electron beam grid-therapy. At an early stage, he introduced a simulator, computerized treatment planning and in-house developed record and verify software. He retired in 1990 as Professor emeritus in Radiation and Cellular Biology at the University of Chicago. Dr. Ovadia was an early and strong supporter of AAPM. He was present at the Chicago ROMPS meeting where the decision was made to form an independent professional society for medical physics. He served as AAPM president in 1976. Jacques Ovadia is survived by his wife of 58 years, Florence, their daughter Corinne Graefe and son Marc Ovadia, MD, as well as four grandchildren and one great-grandchild. Jacques’ dynamic and ever enthusiastic personality inspired all who collaborated with him. He will be greatly missed.

60 APPLIED LIFE SCIENCES↗

Systematic study of target localization for bioluminescence tomography guided radiation therapy

Purpose: To overcome the limitation of CT/cone-beam CT (CBCT) in guiding radiation for soft tissue targets, the authors developed a spectrally resolved bioluminescence tomography (BLT) system for the small animal radiation research platform. The authors systematically assessed the performance of the BLT system in terms of target localization and the ability to resolve two neighboring sources in simulations, tissue-mimicking phantom, and in vivo environments. Methods: Multispectral measurements acquired in a single projection were used for the BLT reconstruction. The incomplete variables truncated conjugate gradient algorithm with an iterative permissible region shrinking strategy was employed as the optimization scheme to reconstruct source distributions. Simulation studies were conducted for single spherical sources with sizes from 0.5 to 3 mm radius at depth of 3–12 mm. The same configuration was also applied for the double source simulation with source separations varying from 3 to 9 mm. Experiments were performed in a standalone BLT/CBCT system. Two self-illuminated sources with 3 and 4.7 mm separations placed inside a tissue-mimicking phantom were chosen as the test cases. Live mice implanted with single-source at 6 and 9 mm depth, two sources at 3 and 5 mm separation at depth of 5 mm, or three sources in the abdomen were also used to illustrate the localization capability of the BLT system for multiple targets in vivo. Results: For simulation study, approximate 1 mm accuracy can be achieved at localizing center of mass (CoM) for single-source and grouped CoM for double source cases. For the case of 1.5 mm radius source, a common tumor size used in preclinical study, their simulation shows that for all the source separations considered, except for the 3 mm separation at 9 and 12 mm depth, the two neighboring sources can be resolved at depths from 3 to 12 mm. Phantom experiments illustrated that 2D bioluminescence imaging failed to distinguish two sources, but BLT can provide 3D source localization with approximately 1 mm accuracy. The in vivo results are encouraging that 1 and 1.7 mm accuracy can be attained for the single-source case at 6 and 9 mm depth, respectively. For the 2 sources in vivo study, both sources can be distinguished at 3 and 5 mm separations, and approximately 1 mm localization accuracy can also be achieved. Conclusions: This study demonstrated that their multispectral BLT/CBCT system could be potentially applied to localize and resolve multiple sources at wide range of source sizes, depths, and separations. The average accuracy of localizing CoM for single-source and grouped CoM for double sources is approximately 1 mm except deep-seated target. The information provided in this study can be instructive to devise treatment margins for BLT-guided irradiation. These results also suggest that the 3D BLT system could guide radiation for the situation with multiple targets, such as metastatic tumor models.

60 APPLIED LIFE SCIENCES↗

Conformal image-guided microbeam radiation therapy at the ESRF biomedical beamline ID17

Purpose: Upcoming veterinary trials in microbeam radiation therapy (MRT) demand for more advanced irradiation techniques than in preclinical research with small animals. The treatment of deep-seated tumors in cats and dogs with MRT requires sophisticated irradiation geometries from multiple ports, which impose further efforts to spare the normal tissue surrounding the target. Methods: This work presents the development and benchmarking of a precise patient alignment protocol for MRT at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF). The positioning of the patient prior to irradiation is verified by taking x-ray projection images from different angles. Results: Using four external fiducial markers of 1.7 mm diameter and computed tomography-based treatment planning, a target alignment error of less than 2 mm can be achieved with an angular deviation of less than 2{sup ∘}. Minor improvements on the protocol and the use of smaller markers indicate that even a precision better than 1 mm is technically feasible. Detailed investigations concerning the imaging dose lead to the conclusion that doses for skull radiographs lie in the same range as dose reference levels for human head radiographs. A currently used online dose monitor for MRT has been proven to give reliable results for the imaging beam. Conclusions: The ESRF biomedical beamline ID17 is technically ready to apply conformal image-guided MRT from multiple ports to large animals during future veterinary trials.

60 APPLIED LIFE SCIENCES↗

SU-F-E-17: A Dedicated Teaching and Research Linac as a Stepping Stone to Introduce Medical Physics to Students

Purpose: This work describes how a non-clinical, research and teaching Linac is used as an extremely motivating and exciting way to introduce students to medical physics. Methods: The dedicated facility was inaugurated in 2014. The facility is composed of a fully equipped and functional state-of-the-art Varian TrueBeam Linac and a complete set of physics instruments and QA phantoms for the Linac and onboard imaging. The Linac bunker and treatment console are oversized such that a class of 12–15 can comfortably fit, seated if needed for longer sessions. A 3cr undergraduate laboratory course that includes medical imaging, x-ray source characterization (mAs, kVp, and filtering) and many others including an introductory Linac laboratory was created. The latter is composed of one general 4-hours session and a weekly 4-hours session for teams of two students. The general session includes a hands-on presentation of the Linac, its environment and a formal safety and radiation protection course (with an exam). Results: Since the winter of 2015, senior undergraduate (total of 15) pursuing either the medical physics or the biomedical engineering tracks can register. At the Linac, the students are allowed full control of the experiments, including set-up and irradiation. Supervisor intervention is limited to safety concerns for students or equipment. Measurements of output factors using two chambers (regular and small field) for various field sizes (1×1 to 30×30 cm{sup 2}) and of detailed depth-dose curves for 6 MV, 6 and 12 MeV beams are to be performed and discussed in a formal report. Conclusion: Full access to, and control of, a Linac is the high point of this course. It provides a glimpse of medical physics and generates an experimental background for those continuing to CAMPEP programs. This dedicated, non-clinical facility further enable enhance CAMPEP graduate teaching and research activities not possible with a clinical device.

60 APPLIED LIFE SCIENCES↗

SU-F-T-385: Evaluation the Influence of 6 and 15-MV Photon Energies of Intensitymodulated Radiation Therapy for Prostate Cancer

Purpose: This study was aimed to study the effects oflow- and high-energy intensity-modulated (IMRT)photon beams on the planning of target volume and thecritical organs in cases of prostate cancer. Methods: Thirty plans were generated using either 6 MV or 15 MValone, and both 6 and 15 MV beams. For each plangenerated using suitable planning objectives and doseconstraints, which was set to be identical except thebeam energy. The plans were analyzed in terms of targetcoverage, conformity, and homogeneity regardless ofbeam energy. Results: Mean percentage of V 70Gy ofrectal wall in 6 MV, 15 MV and mixed-energy plans was16.9%, 17.8%, and 16.4%, respectively, while the meanpercentage of V 40Gy was 53.6%, 52.3%, and 50.4%.The mean dose to femoral heads in 6 MV, 15 MV, andmixed-energy plans were 30.1 Gy, 25.5 Gy, and 25.4 Gy,respectively. The integral dose of 6 MV plans was 10%(on average) larger than those of 15 MV or mixed-energyplans. Conclusion: The preliminary results suggested thatmixed-energy IMRT plans may take an advantage of thedosimetric characteristics of low- and high-energybeams. Although the reduction of dose to the organs atrisk may not be clinically relevant, in this study, mixingenergy in an IMRT plans showed better OAR sparingand for deep-seated tumors, the overall plan quality wasimproved.

60 APPLIED LIFE SCIENCES↗