Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Product Consistency Test Results for the HLW HAlG Glasses

This report summarizes the chemical analysis of Product Consistency Test leachates received from Pacific Northwest National Laboratory (PNNL). The leachates are from a series of quenched simulated nuclear waste glasses designated High-Level Waste High Aluminum Glass that were designed and fabricated at PNNL. The reported data is provided to be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. The elemental release for the study glasses is reported as normalized concentration NCi. NCi of several elements was computed for both the target and measured glass compositions. Several of the glasses exhibited NC B , NC Li , and/or NC Na values that were greater than the Environmental Assessment (EA) benchmark values. Several of the leachates from approved reference material (ARM) glasses included with the study glasses had elemental concentrations greater than the expected ranges. Two water blanks contained measurable amounts of Si; measurements confirmed by rerun samples. One water blank also contained a measurable amount of Na.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote Sensing Approach for Monitoring Tree Health Adjacent to Transmission Corridors

This study presents an initial proof-of-concept for a satellite-based remote sensing approach to identify and monitor potential areas of poor tree health across the entire BPA service territory on an annual basis. We tested three variants of “delta peak NDVI” ( ΔPN ) change detection metrics that express interannual variation in primary productivity relative to a baseline by comparing ΔPN values for known insect/disease disturbances and nearby reference locations. All three metrics showed promise for detecting poor tree health in the year during disturbance, but the metric based on the difference from the long-term (2016-2024) median ( Δ Med PN ) was preferred due to its responsiveness to change in the years during and after disturbance, resilience to interannual variation, and ease of interpretation as being above or below normal. Comparison of Δ Med PN grouped by relative severity of disturbance indicated it was not sensitive enough to detect “low” severity disturbances, as mapped by USGS’s LANDFIRE program, but could distinguish “moderate” and “high” severity disturbances from reference locations. These findings informed selection of a threshold for Δ Med PN , which was combined with areas exhibiting negative NDVI to map potential areas of concern. Visual inspection of before/after high-resolution imagery and NDVI time series showed that many areas of concern aligned with visible signs of defoliation and die-off as well as other types of disturbance (e.g., landslides, logging, road grading, flooding). Some areas of concern are thought to be false detections caused by persistent shadow, and some could not be explained with visual inspection due to spatiotemporal limitations of before/after imagery. In summary, our approach shows promise for large-scale monitoring of tree health adjacent to BPA transmission lines, but additional work is recommended to improve model sophistication and remove noise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOWNWARD CATASTROPHE OF SOLAR MAGNETIC FLUX ROPES

2.5-dimensional time-dependent ideal magnetohydrodynamic (MHD) models in Cartesian coordinates were used in previous studies to seek MHD equilibria involving a magnetic flux rope embedded in a bipolar, partially open background field. As demonstrated by these studies, the equilibrium solutions of the system are separated into two branches: the flux rope sticks to the photosphere for solutions at the lower branch but is suspended in the corona for those at the upper branch. Moreover, a solution originally at the lower branch jumps to the upper, as the related control parameter increases and reaches a critical value, and the associated jump is here referred to as an upward catastrophe. The present paper advances these studies in three aspects. First, the magnetic field is changed to be force-free; the system still experiences an upward catastrophe with an increase in each control parameter. Second, under the force-free approximation, there also exists a downward catastrophe, characterized by the jump of a solution from the upper branch to the lower. Both catastrophes are irreversible processes connecting the two branches of equilibrium solutions so as to form a cycle. Finally, the magnetic energy in the numerical domain is calculated. It is found that there exists a magnetic energy release for both catastrophes. The Ampère's force, which vanishes everywhere for force-free fields, appears only during the catastrophes and does positive work, which serves as a major mechanism for the energy release. The implications of the downward catastrophe and its relevance to solar activities are briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating Solar Resource Data Obtained from Multiple Radiometers Deployed at the National Renewable Energy Laboratory: Preprint

Solar radiation resource measurements from radiometers are used to predict and evaluate the performance of photovoltaic and concentrating solar power systems, validate satellite-based models for estimating solar resources, and advance research in solar forecasting and climate change. This study analyzes the performance of various commercially available radiometers used for measuring global horizontal irradiances (GHI) and direct normal irradiances (DNI). These include pyranometers, pyrheliometers, rotating shadowband irradiometers, and a pyranometer with a shading ring deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory (SRRL). The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012) and compared to measurements from radiometers with the lowest values of estimated measurement uncertainties for producing reference GHI and DNI.

14 SOLAR ENERGY↗

WE-D-204-07: Development of An ImageJ Plugin for Renal Function Quantification: RenalQuant

Purpose: Commercial workstations usually have their own software to calculate dynamic renal functions. However, usually they have low flexibility and subjectivity on delimiting kidney and background areas. The aim of this paper is to present a public domain software, called RenalQuant, capable to semi-automatically draw regions of interest on dynamic renal scintigraphies, extracting data and generating renal function quantification parameters. Methods: The software was developed in Java and written as an ImageJ-based plugin. The preprocessing and segmentation steps include the user’s selection of one time frame with higher activity in kidney’s region, compared with background, and low activity in the liver. Next, the chosen time frame is smoothed using a Gaussian low pass spatial filter (σ = 3) for noise reduction and better delimitation of kidneys. The maximum entropy thresholding method is used for segmentation. A background area is automatically placed below each kidney, and the user confirms if these regions are correctly segmented and positioned. Quantitative data are extracted and each renogram and relative renal function (RRF) value is calculated and displayed. Results: RenalQuant plugin was validated using retrospective 20 patients’ 99mTc-DTPA exams, and compared with results produced by commercial workstation software, referred as reference. The renograms intraclass correlation coefficients (ICC) were calculated and false-negative and false-positive RRF values were analyzed. The results showed that ICC values between RenalQuant plugin and reference software for both kidneys’ renograms were higher than 0.75, showing excellent reliability. Conclusion: Our results indicated RenalQuant plugin can be trustingly used to generate renograms, using DICOM dynamic renal scintigraphy exams as input. It is user friendly and user’s interaction occurs at a minimum level. Further studies have to investigate how to increase RRF accuracy and explore how to solve limitations in the segmentation step, mainly when background region has higher activity compared to kidneys. Financial support by CAPES.

60 APPLIED LIFE SCIENCES↗

TH-CD-207B-11: Multi-Vendor Phantom Study of CT Lung Density Metrics: Is a Reproducibility of Less Than 1 HU Achievable?

Purpose: To standardize the calibration procedures of CT lung density measurements using low-density reference foams in a phantom, and to demonstrate a reproducibility of less than 1 HU for lung equivalent foam densities measured across CT vendor platforms and protocols. Methods: A phantom study was conducted on CT scanner models from 4 vendors at 100, 120, and 135/140 kVp and 1.5, 3, and 6 mGy dose settings, using a lung density phantom containing air, water, and 3 reference foams (indirectly calibrated) with discrete densities simulating a 5-cm slice of the human chest. Customized segmentation software was used to analyze the images and generate a mean HU and variance for each of the density for the 22 vendor/protocols. A 3-step calibration process was devised to remove a scanner-dependent parameter using linear regression of the HU value vs the relative electron density. The results were mapped to a single energy (80 keV) for final comparison. Results: The heterogeneity across vendor platforms for each density assessed by a random effects model was reduced by 50% after re-calibration, while the standard deviation of the mean HU values also improved by about the same amount. The 95% CI of the final HU value was within +/−1 HU for all 3 reference foam densities. For the backing lung foam in the phantom (served as an “unknown”), this CI is +/− 1.6 HU. The kVp and dose settings did not appear to have significant contributions to the variability. Conclusion: With the proposed calibration procedures, the inter-scanner reproducibility of better than 1 HU is demonstrated in the current phantom study for the reference foam densities, but not yet achieved for a test density. The sources of error are being investigated in the next round of scanning with a certified Standard Reference Material for direct calibration. Fain: research funding from GE Healthcare to develop pulmonary MRI techniques. Hoppel: employee of Toshiba Medical Research Institute USA/financial interest with GE Healthcare. M. Fuld: employee of Siemens Healthcare for medical device equipment and software. This project is supported partially by RSNA QIBA Concept Award (Fain), NIH/NIBIB, HHSN268201300071C (Y).

60 APPLIED LIFE SCIENCES↗

Electron Energy Partition across Interplanetary Shocks. II. Statistics

Abstract A statistical analysis of 15,210 electron velocity distribution function (VDF) fits, observed within ±2 hr of 52 interplanetary (IP) shocks by the Wind spacecraft near 1 au, is presented. This is the second in a three-part series on electron VDFs near IP shocks. The electron velocity moment statistics for the dense, low-energy core, tenuous, hot halo, and field-aligned beam/strahl are a statistically significant list of values illustrated with both histograms and tabular lists for reference and baselines in future work. Given the large statistics in this investigation, the beam/strahl fit results in the upstream are now the most comprehensive attempt to parameterize the beam/strahl electron velocity moments in the ambient solar wind. The median density, temperature, beta, and temperature anisotropy values for the core(halo)[beam/strahl] components, with subscripts ec(eh)[eb], of all fit results, respectively, are , , , and . This work will also serve as a 1 au baseline and reference for missions like Parker Solar Probe and Solar Orbiter .

79 ASTRONOMY AND ASTROPHYSICS↗

Assessments of advanced reactor heat supply to high temperature industrial unit operations: Heat Engines and Heat Pumps

In this report, the feasibility of employing Advanced Nuclear Reactors to supply the necessary high-quality heat to Industrial Processes is investigated. As a first step, the most relevant industrial applications that could benefit from this coupling were identified. Four industries including petroleum refining (distillation, catalyst regeneration, hydro-steam cracking), chemical polymers, steel manufacturing (metals annealing/soaking) and cement manufacturing (calcination of limestone and dolomite industries) were considered. An overview of the heat duties, i.e., the temperatures and thermal powers required by representative plants of the different processes, was provided. Secondly, the thermodynamic conditions of the steam produced by representative designs of Advanced Reactor concepts (Liquid Metal Fast Breeder Reactors, Molten Salt Reactors, and High Temperature Gas-cooled Reactors) were summarized. The comparison between the requirements of the industrial processes and the capabilities of the candidate nuclear power plants showed that only a few processes could benefit from the coupling. Although Advanced Reactors operate at higher temperatures than Light Water Reactors, the thermodynamic conditions of the generated steam flow rates are generally not suitable for the selected applications. At the same time, data indicate that most of the processes can be suitably supplied if the temperature of steam is elevated to 900 °C. One possible solution to boost the quality of the steam from the nuclear island involves the use of a heat pump. Based on a technology similar to that found in refrigerators and air conditioners, heat pumps extract heat from a source, elevate its temperature and transfer it to where it is needed. A simple numerical example illustrating the viability of this method is described. Specifically, the energy conversion cycle of a conventional Pressurized Water Reactor was extended to incorporate a compressor to raise the heating value of the steam produced by the reactor. Two reference configurations, i.e., one where the industrial process coupled to the nuclear power plant exhausts saturated liquid and the other where it exhausts saturated steam, were considered. The thermal efficiencies achievable by increasing the heating value of the reactor steam in this way are significantly greater than by direct electric heating.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TH-C-18A-12: Evaluation of the Impact of Body Size and Tube Output Limits in the Optimization of Fast Scanning with High-Pitch Dual Source CT

Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, and B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recommendations for an Applicant to Calculate Activity Data for Greenhouse Gases Estimates

In 2009, the U.S. Nuclear Regulatory Commission (NRC) directed the NRC staff to address climate change issues and consider the impacts of the emissions of carbon dioxide (CO 2 ) and other greenhouse gases (GHGs) in its environmental reviews for major licensing actions (NRC 2009b). To implement this direction from the Commission, the staff issued guidance in 2011 and updated guidance in 2014 in Attachment 1 to Interim Staff Guidance COL/ESP-ISG-026 (NRC 2011; NRC 2014). This guidance provides a simpler method than the method described in RG 4.2 Rev. 3, that an applicant can use to meet the plant parameter envelope (PPE) value from the Generic Environmental Impact Statement for Licensing of New Nuclear Reactors (NR GEIS). NRC staff estimated the 97-year lifecycle GHG emissions from a reference 1000 megawatt electrical (MWe) light-water reactor (LWR) for various activities associated with construction, operation (including uranium fuel cycle), and decommissioning of nuclear power plants and presented the results in Appendix H of the NR GEIS. Appendix H of the NR GEIS includes estimates of direct emissions from construction equipment and emergency diesel engines in a nuclear facility and indirect emissions from workforce vehicular traffic, fuel transportation and the uranium fuel cycle. The NR GEIS Section 3.3 extended the estimates in Appendix H for the installation of two 1000 MWe nuclear reactors on the same site. Scaling factors were used to extrapolate the GHG emissions of a reference 1000 MWe reactor to a two-unit nuclear reactor plant (each reactor unit generating 1000 MWe). GHG emission estimates for building, operation, decommissioning and safe storage (SAFSTOR) for a two-unit nuclear reactor plant would be based on the plant’s physical size, and therefore estimates for these source categories were assumed to be twice the value of the reference 1000 MWe reactor. However, GHG emissions from the fuel cycle (including fuel transportation) were scaled upward by a factor of 3, based on plant efficiencies greater than the 80 percent assumption in Appendix H. Table 1 below shows the PPE emissions for two 1000 MWe nuclear reactors as provided in NR GEIS. The total GHG emissions for two 1000 MWe reactors were calculated as 2,534,000 metric tons (MT) of CO 2 equivalent (CO 2 (e)) based on a 97 year GHG life cycle period. The GHG emissions lifetime of 97 years for a reference nuclear reactor includes a 7-year building phase, 40 years of operation, 10 years of active decommissioning, and 40 years of SAFSTOR operations (NRC 2024). Construction equipment and vehicular traffic from workers commute would contribute to the GHG emissions during a 7-year building phase. Uranium fuel cycle, vehicular traffic, fuel and waste transportation, and testing of standby diesel generators would contribute to GHG emissions during the 40-year operations phase. While NRC’s regulations allow up to 60 years of reactor facility decommissioning, Appendix H estimated that most of the GHGs would occur over an estimated 10-year period during which to the licensee would engage in significant demolition and earth-moving activities, as discussed in Supplement 1 to NUREG-0586 (NRC 2002). Vehicular traffic by the workforce during a 40-year SAFSTOR period would additionally contribute GHG emissions. The carbon footprint for a 40-year SAFSTOR period was separately analyzed from the decommissioning activities as provided in Table YYYY-2 of the staff issued guidance in 2011 (NRC 2011).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calibrating the SPECTACULAR constitutive model using legacy Sandia data for two filled epoxy systems: 828/CTBN/DEA/GMB and 828/DEA/GMB

The SPECTACULAR model is a development extension of the Simplified Potential Energy Clock (SPEC) model. Both models are nonlinear viscoelastic constitutive models used to predict a wide range of time-dependent behaviors in epoxies and other glass-forming materials. This report documents the procedures used to generate SPECTACULAR calibrations for two particulate-filled epoxy systems, 828/CTBN/DEA/GMB and 828/DEA/GMB. No previous SPECTACULAR or SPEC calibration exists for 828/CTBN/DEA/GMB, while a legacy SPEC calibration exists for 828/DEA/GMB. To generate the SPECTACULAR calibrations, a step-by-step procedure was executed to determine parameters in groups with minimal coupling between parameter groups. This procedure has often been deployed to calibrate SPEC, therefore the resulting SPECTACULAR calibration is backwards compatible with SPEC (i.e. none of the extensions specific to SPECTACULAR are used). The calibration procedure used legacy Sandia experimental data stored on the Polymer Properties Database website. The experiments used for calibration included shear master curves, isofrequency temperature sweeps under oscillatory shear, the bulk modulus at room temperature, the thermal strain during a temperature sweep, and compression through yield at multiple temperatures below the glass transition temperature. Overall, the calibrated models fit the experimental data remarkably well. However, the glassy shear modulus varies depending on the experiment used to calibrate it. For instance, the shear master curve, isofrequency temperature sweep under oscillatory shear, and the Young's modulus in glassy compression yield values for the glassy shear modulus at the reference temperature that vary by as much as 15 %. Also, for 828/CTBN/DEA/GMB, the temperature dependence of the glassy shear modulus when fit to the Young's modulus at different temperatures is approximately four times larger than when it is determined from the isofrequency temperature sweep under oscillatory shear. For 828/DEA/GMB, the temperature dependence of the shear modulus determined from the isofrequency temperature sweep under oscillatory shear accurately predicts the Young's modulus at different temperatures. When choosing values for the shear modulus, fitting the glassy compression data was prioritized. The new and legacy calibrations for 828/DEA/GMB are similar and appear to have been calibrated from the same data. However, the new calibration improves the fit to the thermal strain data. In addition to the standard calibrations, development calibrations were produced that take advantage of development features of SPECTACULAR , including an updated equilibrium Helmholtz free energy that eliminates undesirable behavior found in previous work. In addition to the previously mentioned experimental data, the development calibrations require data for the heat capacity during a stress-free temperature sweep to calibrate thermal terms.

36 MATERIALS SCIENCE↗

Rare Earth Elements (REE) and Critical Minerals (CM) in Middle Pennsylvanian-Age Coals and Associated Sediments in the Central Appalachian Basin, Eastern U.S.A.

The Central Appalachian Basin (CAB) of Kentucky, Tennessee, West Virginia and Virginia has a long history of coal mining and oil and gas extraction that has empowered the regional and national economies, the development of infrastructure, and a highly trained energy resources work force. As our societal demands for advanced technologies have rapidly increased in recent years, coal-related materials are viewed as an important new unconventional domestic source of critical minerals (CM) that are required for telecommunications, aerospace and transportation industries, electronics, the transition to low-carbon emissions energy production, and many consumer products. Coal-related materials encompass coal, associated sediments, coal mining waste materials, produced waters, and ash residues from coal-fired power plants. An important objective of the Evolve Central Appalachia Project (Evolve CAPP), sponsored by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) is to assess the quantity and distribution of CM resources in the CAB region. The rare earth elements (REE) are considered highest priority, although other important CM such as niobium, gallium, and zirconium are known to occur in the Middle Pennsylvanian-age coals and sediments. Working with coal industry partners who provided access to drill cores, coal-related sediments and waste materials, over 600 samples have been collected for laboratory analysis, and over 730 materials have been scanned using portable x-ray fluorescence (pXRF) equipment. The application of pXRF provides the means for real-time semiquantitative analysis of CM content at very close spacings (typically 2-3 inch intervals) along drill core and in-situ channel samples that span the roof, coal seam, and floor rock. The comparison of pXRF geochemical data with laboratory results, geologic data, and downhole spectral gamma logs can provide high resolution input to lithologic and depositional models for future CM resource evaluations. The preliminary findings show that pXRF is capable of accurately measuring low concentrations of many of the CM with a high level of confidence (Ba, Cr, Ga, K, Nb, Rb, Sr, Th, Y), whereas for others (La, Ce, Co, Mn, Nd, Ni, Sc, Ti, V) the detection limits are very high or spectral interferences increase the uncertainty. Notably, the mean abundances of Y (34 ppm), La (86 ppm), Ga (40 ppm), and V (146 ppm) in coal underclays in the CAB region are up to 7X enriched compared with the overlying coal. These values also exceed the reported concentrations in published reference materials for upper continental crustal rocks (Rudnick and Gao, 2003), North American Shale Composite (Gromet et al., 1984), and North American coal (Finkelman, 1993). The pXRF data are in part verified by laboratory results that indicate the mean Y abundance (36 ppm) is highly correlated (R2 = 0.807) with total REE (ΣREE). The correlation is even higher (R2 = 0.957) with heavy REE (ΣHREE). Applying these correlations to the pXRF data for the coal underclays, the mean estimated values for ΣREE+Y and ΣHREE+Y are 270 ppm and 58 ppm, respectively. Although these average values are not considered high, the range of Y measured by pXRF in the coal underclays extended as high as 114 ppm, which would suggest ΣREE+Y equal to 847 ppm. The mean abundances of Zr (192 ppm) and Th (21 ppm) in coal underclays are also enriched compared with the overlying coal and these results likely reflect the presence of resistant detrital heavy minerals such as monazite, xenotime, and zircon in the underclay matrix. Several of the profiled coal seams and associated wall rocks contained thin volcanic ash layers up to 4-5 inches in thickness. The extent to which these ash fall layers provided a source for CM under the paleoenvironmental conditions that resulted in coal deposits in the CAB remains to be fully studied. Continuing investigations in the Evolve CAPP study area will include laboratory determinations of mineralogic and clay compositions, and evaluations of CM geochemical mobility in the coal and coal underclays.

Lassetter, Billy↗

Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques

Purpose: To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. Methods: The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch distance and a sensitive volume of about 4 mm{sup 3}. The detector has been characterized with {sup 60}Co radiation and MV x rays from different linear accelerators (with flattened and unflattened beam qualities). Sensitivity dependence on dose per pulse has been evaluated under MV x rays by changing both the source to detector distance and the beam quality. Bias voltage has been varied in order to evaluate the charge collection efficiency in the most critical conditions. Relative dose profiles have been measured for both flattened and unflattened distributions with different field sizes. The reference detectors were a commercial array of ionization chambers and an amorphous silicon flat panel in direct conversion configuration. Profiles of dose distribution have been measured also with intensity modulated radiation therapy (IMRT), stereotactic radiosurgery (SRS), and volumetric modulated arc therapy (VMAT) patient plans. Comparison has been done with a commercial diode array and with Gafchromic EBT3 films. Results: Repeatability and stability under continuous gamma irradiation are within 0.3%, in spite of low active volume and sensitivity (∼200 pC/Gy). Deviation from linearity is in the range [0.3%, −0.9%] for a dose of at least 20 cGy, while a worsening of linearity is observed below 10 cGy. Charge collection efficiency with 2.67 mGy/pulse is higher than 99%, leading to a ±0.9% sensitivity change in the range 0.09–2.67 mGy/pulse (covering all flattened and unflattened beam qualities). Tissue to phantom ratios show an agreement within 0.6% with the reference detector up to 34 cm depth. For field sizes in the range 2 × 2 to 15 × 15 cm{sup 2}, the output factors are in agreement with a thimble chamber within 2%, while with 25 × 25 cm{sup 2} field size, an underestimation of 4.0% was found. Agreement of field and penumbra width measurements with the flat panel is of the order of 1 mm down to 1 × 1 cm{sup 2} field size. Flatness and symmetry values measured with the 1D array and the reference detectors are comparable, and differences are always smaller than 1%. Angular dependence of the detector, when compared to measurements taken with a cylindrical chamber in the same phantom, is as large as 16%. This includes inhomogeneity and asymmetry of the design, which during plan verification are accounted for by the treatment planning system (TPS). The detector is capable to reproduce the dose distributions of IMRT and VMAT plans with a maximum deviation from TPS of 3.0% in the target region. In the case of VMAT and SRS plans, an average (maximum) deviation of the order of 1% (4%) from films has been measured. Conclusions: The investigated technology appears to be useful both for Linac QA and patient plan verification, especially in treatments with steep dose gradients and nonuniform dose rates such as VMAT and SRS. Major limitations of the present prototype are the linearity at low dose, which can be solved by optimizing the readout electronics, and the underestimation of output factors with large field sizes. The latter problem is presently not completely understood and will require further investigations.

60 APPLIED LIFE SCIENCES↗

A small core in Vesta inferred from Dawn’s observations

Vesta’s large-scale interior structure had previously been constrained primarily using the gravity and shape data from the Dawn mission. However, these data alone still allow a wide range of possibilities for the differentiation state of the body. The moment of inertia is arguably the most diagnostic parameter related to the radial density distribution of a planetary body, making it crucial for assessing the body’s state of internal differentiation. Determining the moment of inertia requires additional measurements of the amplitudes of small rotational motions, such as precession and nutation. Here we report an updated estimate of the moment of inertia of Vesta inferred from Dawn’s Doppler tracking via the Deep Space Network and onboard imaging data. The recovered value for Vesta’s normalized polar moment of inertia is $\overline{C}$/MR 2 = 0.4208 ± 0.0047 (where M is the mass of Vesta and R is the reference radius), which is only 6.6% lower than the homogeneous value of 0.4505. This value, combined with the gravity field and global shape, suggests that Vesta’s interior has limited density stratification beneath its howardite–eucrite–diogenite-dominated crust. We propose two possible origin scenarios that are consistent with the observed constraints. In the first scenario, Vesta’s interior did not undergo full differentiation due to late accretion. In the second scenario, Vesta originated as an impact remnant of a larger differentiated body re-accreted with non-chondritic bulk composition produced from a catastrophic impact. Vesta did not experience complete differentiation in either scenario, suggesting that its current state reflects a complex interplay between its accretion timing, thermal evolution, redistribution of 26 Al bearing melt and/or impact processes.

CNEOS 2014-01-08 bolide↗

The Influence of Water Vapor on the Electrochemical Shift of an Ionic Liquid Measured by Ambient Pressure X-ray Photoelectron Spectroscopy

Ionic liquids (ILs) are considered to be one of the steppingstones to fabricate next generation electrochemical devices given their unique physical and chemical properties. The addition of water to ILs significantly impact electrochemical related properties including viscosity, density, conductivity, and electrochemical window. Here, we utilize ambient pressure X-ray photoelectron spectroscopy (APXPS) to examine the impact of water on values of the electrochemical shift (S), which is determined by measuring changes in binding energy shifts as a function of an external bias. APXPS spectra of C 1s, O 1s and N 1s regions are examined for the IL 1-butyl-3-methylimidazolium acetate, [C 4 mim][OAc], at the IL/gas interface as a function of both water vapor pressure and external bias. Results reveal that in the absence of water vapor there is an IL ohmic drop between the working electrode and quasi reference electrode, giving rise to chemical specific S values of less than one. Upon introducing water vapor, S values approach one as a function of increasing water vapor pressure, indicating a decrease in the IL ohmic drop as the IL/water mixture becomes more conductive and the potential drop is driven by the electric double layer at the electrode/IL interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar plus: A review of the end-user economics of solar PV integration with storage and load control in residential buildings

Batteries and load control devices can increase the value of distributed solar photovoltaics (PV) from multiple perspectives - end-user, utility, and social. This review paper summarizes the end-user economics of battery and load control technologies that increase the value of PV by controlling and temporally shifting PV output, an approach referred to as 'solar plus.' Solar plus can increase on-site PV use. The literature shows that these values justify the incremental costs of solar plus devices for a wide variety of technologies, geographies, and customer load profiles, especially for customers in three rate structure contexts: where PV is sold to the grid at a lower value than the customer's retail rate, in time-of-use rates where peak periods do not coincide with PV output, and in demand charge rates where load peaks do not coincide with PV output. Rate structure and policy reform may be necessary to ensure that increasing solar plus deployment provides both end-user and system-level benefits.

14 SOLAR ENERGY↗

Electron Screening Effects on {alpha}-decay

An open problem in Nuclear Astrophysics concerns the understanding of electron-screening effects on nuclear reaction rates at stellar energies. In this framework, we have proposed to investigate the influence of the electron cloud on {alpha}-decay by measuring Q-values and {alpha}-decay half-lives of fully stripped, H-like and He-like ions. These kinds of measurements have been feasible just recently for highly-charged radioactive nuclides by fragmentation of {sup 238}U at relativistic energies at the FRS-ESR facility at GSI. In this way it is possible to produce, efficiently separate and store highly-charged {alpha}-emitters. Candidates for the proposed investigation were carefully selected and will be studied by using the Schottky Mass Spectroscopy technique. In order to establish a solid reference data set, lifetimes and Q{sub {alpha}}-value measurements of the corresponding neutrals have been performed directly at the FRS, by implanting the separated ions into an active Silicon stopper.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Speeding genomic island discovery through systematic design of reference database composition

Background Genomic islands (GIs) are mobile genetic elements that integrate site-specifically into bacterial chromosomes, bearing genes that affect phenotypes such as pathogenicity and metabolism. GIs typically occur sporadically among related bacterial strains, enabling comparative genomic approaches to GI identification. For a candidate GI in a query genome, the number of reference genomes with a precise deletion of the GI serves as a support value for the GI. Our comparative software for GI identification was slowed by our original use of large reference genome databases (DBs). Here we explore smaller species-focused DBs. Results With increasing DB size, recovery of our reliable prophage GI calls reached a plateau, while recovery of less reliable GI calls (FPs) increased rapidly as DB sizes exceeded ~500 genomes; i.e., overlarge DBs can increase FP rates. Paradoxically, relative to prophages, FPs were both more frequently supported only by genomes outside the species and more frequently supported only by genomes inside the species; this may be due to their generally lower support values. Setting a DB size limit for our SMA ll R anked T ailored (SMART) DB design speeded runtime ~65-fold. Strictly intra-species DBs would tend to lower yields of prophages for small species (with few genomes available); simulations with large species showed that this could be partially overcome by reaching outside the species to closely related taxa, without an FP burden. Employing such taxonomic outreach in DB design generated redundancy in the DB set; as few as 2984 DBs were needed to cover all 47894 prokaryotic species. Conclusions Runtime decreased dramatically with SMART DB design, with only minor losses of prophages. We also describe potential utility in other comparative genomics projects.

59 BASIC BIOLOGICAL SCIENCES↗