Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Moore ME Feb 18 2019 aerosol class for Northern NM College [Slides)

This presentation was prepared for the request from Northern New Mexico College. "For your talk I’m thinking a bit more detail about the specific sampler you’re bringing, and the types in use at LANL, then setup and ops check, loading and removing a filter, cutting out the right size circle, reading the sample (we have a couple Eberline SAC-4s and Ludlum 2929s here), and radon/daughters corrections."

61 RADIATION PROTECTION AND DOSIMETRY↗

Current and Future Work on Wound Contamination by Alpha Emitters at Los Alamos [Slides]

Our team calculated ‘clinical decision levels’ at which treatment may be warranted (i.e., bioassay and wound measurements which correspond to specific dose thresholds). The actual risk to the patient corresponding to this dose threshold is uncertain – the CED may not tell the whole story. We recently reviewed LANL medical records to characterize adverse events associated with treatment. Future work should include medical records from other institutions and a review and analysis of data to quantify benefit of treatment with a focus on the question, "What factors predict whether treatment will be beneficial?"

61 RADIATION PROTECTION AND DOSIMETRY↗

Health Hazards of Exposures to Radioiodine

Iodine is a chemical element with atomic number 53. Iodine-127 is stable (non-radioactive) and commonly found in nature. Elemental iodine is a purple-colored solid at room temperature and pressure, but spontaneously sublimates (turns into vapor). Iodine is an essential element for life, and is required for proper functioning of the thyroid. Iodine is present in many foods, and is readily absorbed by the body and concentrated in the thyroid gland. A fraction of iodine ingested or inhaled is rapidly removed by the kidneys. The rest of the inhaled or ingested iodine is absorbed the by thyroid and retained for many months. Iodine has a biological half-life of approximately 120 days in health individuals. The biological half-life can be shorter in individuals with hyperthyroidism, and longer in individuals with hypothyroidism. Iodine has a number of radioactive isotopes, most of which have relatively short half-lives (days or weeks). Short half-life iodine isotopes are useful for a variety of medical applications, including imaging and cancer therapy. For example, Iodine-123 (half-life 13 hours) is commonly used for medical imaging of the thyroid, while iodine-131 (half-life 8 days) is used for suppressing thyroid function in individuals with hyperthyroidism or ablating (killing) thyroid cells to treat thyroid cancer. Iodine-125 (half-life 59 days) is produced in nuclear reactors, and has medical uses. Although iodine-125 can be used for thyroid imaging, Iodine-123 is more commonly used for that purpose because of its shorter half-life and higher-energy emissions. Iodine-125 is more commonly used for cancer treatment, and can be processed into small metal pellets (seeds) inserted directly into a tumor. Iodine-125 emits low-energy x-rays which can kill tumor cells and generally cannot escape the tumor, sparing other tissues. Medical iodine for imaging or treatment is typically administered orally in the form a pill or liquid solution. A typical adult thyroid scan using iodine-123 involves having the patient swallow between one and four 0.1 millicuries pills, with the exact dose dependent on the patient’s weight. This results in a whole-body committed effective dose of 80 – 320 mrem, and a thyroid equivalent dose of 1443 – 5772 mrem. Note that the whole-body effective dose relates to the overall cancer risk, while the larger equivalent dose to the thyroid only indicates that most of this risk is the result of exposure to the thyroid. These doses are considered safe, although the procedure is not recommended for pregnant or breastfeeding women. In contrast, the quantities of iodine-131 used for treatment of hyperthyroidism and thyroid cancers are much higher. For treatment of hyperthyroidism, 4 – 10 millicuries are administered, while for thyroid cancer the administration can range from 50 – 150 millicuries of I-131. In addition to medical exposures, large populations were exposed to radioiodine as result of the atomic bombings of Hiroshima and Nagasaki in Japan, and the Chernobyl nuclear accident. These populations have been carefully followed for many years to assess the effect of their radiation exposures on cancer risk. As a result, a great deal is known about the cancer risks associated with radioiodine exposure. Because iodine is concentrated in the thyroid, the principal risk of exposure to radioiodine is thyroid cancer. Children have the highest risk of thyroid cancer after exposure to radioactive iodine. According to a large study of Japanese atomic bomb survivors, an effective dose of one Sievert (100,000 mrem) has been observed to increase the risk of thyroid cancer by a factor of 9.5 in children aged zero to nine years old, by a factor of 3 in children aged 10 to 19 years old, and by barely detectable amounts in adults. Another way of quantifying the risk from radioiodine exposure is from risk coefficients, which provide the risk per unit intake of radionuclides in terms of both morbidity (any cancer) and mortality (death). Both morbidity (risk of cancer) and mortality (death) risks are shown in the table below. Note that because thyroid cancer is almost never fatal, the morbidity coefficients are much larger than the mortality coefficients.

61 RADIATION PROTECTION AND DOSIMETRY↗

US Nuclear Testing: Health Consequences and Policy Decisions

With the approval of President Franklin D. Roosevelt to begin the research on a nuclear bomb in 1941 to the last test conducted by the U.S. in 1992, the fifty-year history of the nuclear weapons testing program has been an expansive topic of research. The program's growth is credited to the race to build the first atomic weapon for war. The termination of the Soviet Union and many other factors, including concerns about the adverse health effects of radioactive fallout, influenced the decline of the need for the program. The discovery of the negative health effects caused by low-level radiation and the subsequent studies influenced sitting U.S. presidents in passing policies that significantly impacted the nuclear weapons testing program.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Neutron Spectrum Determination for the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) with a Multi-Sphere Spectrometer

This report presents the work that was performed to determine the neutron energy spectrum (spectrum) of the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) with a neutron Multi-Sphere Spectrometer (MSS). The spectrometer measurements were performed when the generator is in an INL Materials and Fuels Complex (MFC) laboratory. The measurements were used in a spectrum unfolding software to calculate the neutron spectrum. Based on initial testing of the MSS spectrometer and experience with the unfolding software, an MMRTG spectrum is reported and a justification for the spectrum is provided.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design and Validation of Mechanical & Autonomous Systems in Harsh Environments [Poster]

The autonomous systems within the Mobile Hot Cell provide advanced capabilities over traditional hot cells, pushing the boundaries of these systems in harsh environments. The degraded state of some radiological devices and the variety of designs present a series of challenges that require innovative tooling and procedural solutions. By leveraging technical knowledge and experience from disposition experts at SwRi and other institutions, initial design concepts were produced using rapid prototyping techniques. These concepts were then validated and optimized in a non-hazardous test bed, resulting in iterative improvements at minimal cost.

07 - ISOTOPES AND RADIATION SOURCES↗

Total Effective Dose from Radiologic Emissions from INL Facilities for Calculation of Population Dose for the INL 2024 Annual Site Environmental Report

Total effective radiation dose from airborne releases was calculated using air dispersion modeling performed by the National Oceanic and Atmospheric Administration (NOAA) Idaho Falls Office using their HYSPLIT computer model (Stein et al. 2015; Draxler et al. 2013), and the Dose Multi-Media (DOSEMM) dose assessment model (Rood 2019) . The objective of these calculations was to provide a grid of total effective dose across a model domain that encompasses a 50-mile (80-km) radius from any Idaho National Laboratory (INL) Site source. In addition to INL Site sources, releases from the Radiological and Environmental Sciences Laboratory (RESL) (IF-683) and IF-603 located at the INL Research Center (IRC) within the Idaho Falls city limits were also included. Due to tracking limitations, radionuclides released from IF-611 and IF-603 are modeled as released from IF-603. The dose results will be combined with GIS software to compute a total population dose for the calendar year (CY) 2024 and will be reported in the INL Annual Site Environmental Report (ASER). This report does not cover the population dose calculation and only documents generation of the gridded dose file.

42 - ENGINEERING↗

Response of Silicon-Based Linear Energy Transfer Spectrometers: Implication for Radiation Risk Assessment in Space Flights

There is considerable interest in developing silicon-based telescopes because of their compactness and low power requirements. Three such telescopes have been flown on board the Space Shuttle to measure the linear energy transfer spectra of trapped, galactic cosmic ray, and solar energetic particles. Dosimeters based on single silicon detectors have also been flown on the Mir orbital station. A comparison of the absorbed dose and radiation quality factors calculated from these telescopes with that estimated from measurements made with a tissue equivalent proportional counter show differences which need to be fully understood if these telescopes are to be used for astronaut radiation risk assessments. Instrument performance is complicated by a variety of factors. A Monte Carlo-based technique was developed to model the behavior of both single element detectors in a proton beam, and the performance of a two-element, wide-angle telescope, in the trapped belt proton field inside the Space Shuttle. The technique is based on: (1) radiation transport intranuclear-evaporation model that takes into account the charge and angular distribution of target fragments, (2) Landau-Vavilov distribution of energy deposition allowing for electron escape, (3) true detector geometry of the telescope, (4) coincidence and discriminator settings, (5) spacecraft shielding geometry, and (6) the external space radiation environment, including albedo protons. The value of such detailed modeling and its implications in astronaut risk assessment is addressed. c2001 Elsevier Science B.V. All rights reserved.

manned↗

Neutron environments on the Martian surface

Radiation is a primary concern in the planning of a manned mission to Mars. Recent studies using NASA Langley Research Center's HZETRN space radiation transport code show that the low energy neutron fluence on the Martian surface is larger than previously expected. The upper atmosphere of Mars is exposed to a background radiation field made up of a large number of protons during a solar particle event and mixture of light and heavy ions caused by galactic cosmic rays at other times. In either case, these charged ions interact with the carbon and oxygen atoms of the Martian atmosphere through ionization and nuclear collisions producing secondary ions and neutrons which then interact with the atmospheric atoms in a similar manner. In the past, only these downward moving particles have been counted in evaluating the neutron energy spectrum on the surface. Recent enhancements in the HZETRN code allow for the additional evaluation of those neutrons created within the Martian regolith through the same types of nuclear reactions, which rise to the surface. New calculations using this improved HZETRN code show that these upward moving neutrons contribute significantly to the overall neutron spectrum for energies less than 10 MeV.

NASA Center LaRC↗

Orbit selection and its impact on radiation warning architecture for a human mission to Mars

With the recent announcement of the discovery of the possibility of life on Mars, there is renewed interest in Mars missions, perhaps eventually in human missions. Astronauts on such missions are at risk to occasional periods of enhanced high energy particle flux from the sun known as Solar Particle Events. These events can pose a substantial risk to the health of the astronauts and to the on-board electronics. Effective forecast and warning of these events could provide time to take steps to minimize the risk (retreating to a safe haven, shutting down sensitive equipment, etc.) Providing that forecast capability, will require additional monitoring capability. The extent of this architecture is sensitive to the orbit selected for the transfer to and from Mars. This paper looks at the major classes of Mars missions (Conjunction and Opposition) and sub-categories of these classes and draws conclusions on the number of monitoring satellites needed for each, with a goal to reducing total system cost through optimum orbit selection.

Non-NASA Center↗

Effects of target fragmentation on evaluation of LET spectra from space radiation in low-earth orbit (LEO) environment: impact on SEU predictions

Recent improvements in the radiation transport code HZETRN/BRYNTRN and galactic cosmic ray environmental model have provided an opportunity to investigate the effects of target fragmentation on estimates of single event upset (SEU) rates for spacecraft memory devices. Since target fragments are mostly of very low energy, an SEU prediction model has been derived in terms of particle energy rather than linear energy transfer (LET) to account for nonlinear relationship between range and energy. Predictions are made for SEU rates observed on two Shuttle flights, each at low and high inclination orbit. Corrections due to track structure effects are made for both high energy ions with track structure larger than device sensitive volume and for low energy ions with dense track where charge recombination is important. Results indicate contributions from target fragments are relatively important at large shield depths (or any thick structure material) and at low inclination orbit. Consequently, a more consistent set of predictions for upset rates observed in these two flights is reached when compared to an earlier analysis with CREME model. It is also observed that the errors produced by assuming linear relationship in range and energy in the earlier analysis have fortuitously canceled out the errors for not considering target fragmentation and track structure effects.

STS-51 Shuttle Project↗

Lightweight Radiator System for a Spacecraft

Three documents describe various aspects of a proposed lightweight, deployable radiator system for dissipating excess heat from the life-support system of a habitable spacecraft. The first document focuses on a radiator tube that would include a thin metal liner surrounded and supported by a thicker carbon-fiber-reinforced composite tubular structure that, in turn, would be formed as part of a unitary composite radiator-fin structure consisting mostly of a sheet of reticulated vitreous carbon laminated between carbon-fiber-reinforced face sheets. The thermal and mechanical properties, including the anisotropies, of the component materials are taken into account in the design. The second document describes thermo-structural bumpers, in the form of exterior multiple-ply carbon-fiber sheets enclosing hollows on opposite sides of a radiator fin, which would protect the radiator tube against impinging micrometeors and orbital debris. The third document describes a radiator system that would include multiple panels containing the aforementioned components, among others. The system would also include mechanisms for deploying the panels from compact stowage. Deployment would not involve breaking and remaking of fluid connections to the radiator panels.

Copeland, Robert J.↗

Foundation, excavation and radiation shielding concepts for a 16-m large lunar telescope

NASA is considering a 16-m diameter optical telescope on the moon as a part of the Space Exploration Initiative. Fundamental concepts of engineering activities on the moon and how they can be applied to the establishment of a 16-m large lunar telescope (LLT) are discussed. These fundamental concepts include the engineering response of lunar soils and how they affect construction activities, namely, drilling, blasting, ripping, digging and compaction. A mirror support structure and foundation design concept is proposed. The foundation considered is a multiple contact points spud-can type footing. It does not appear that a deep foundation or the presence of bedrock is required to achieve the telescope foundation stiffness. The LLT system will include a regolith covered housing, the size of a small room, which will contain sensitive electronic equipment including charge coupled devices which need protection from cosmic radiation effects. A brief discussion is made on radiation, radiation transport and radiation effects on electronics and on humans. Radiation protection techniques and the different emplacement schemes for the LLT instrument housing for radiation protection are suggested. A structural concept of an early lunar based telescope is also presented.

Chua, Koon M.↗

Implementing an aerosol dynamic shape factor for cerium oxide powder

The shape factor (X B ) of bulk powder CeO 2 (cerium oxide) particles is estimated to be X B = 1.34 (dimensionless). This is defined in relation to the measured aerated bulk density (0.91 g cm -3 , Hosokawa Micron, Summit NJ, 2018) of the CeO 2 powder. This information is used to determine the RRF (respirable release factor), and other parameters during drop test experiments of nuclear material storage containers at Los Alamos National Laboratory. The calculation is based on an experimental shape factor (X P = 2.66 dimensionless) for CeO 2 particles of the same (chain aggregate) morphology studied by other researchers. In that work, the shape factor was defined in terms of the maximum possible (compacted) density of CeO 2 material (7.13 g cm -3 ).

61 RADIATION PROTECTION AND DOSIMETRY↗

A comprehensive final summary of the MCNP calculations performed concerning the UW 137 Cs release event

This document combines and supersedes earlier reports (e.g. LA-UR-19-32358 and LA-UR-20- 22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with various surfaces of interest to the University of Washington 137 Cs release event. These surfaces include: Exterior surface of round and rectangular ducts, Exterior surface of outdoor brick work, Exterior surface of cast iron pipes, Exterior surface of an O 2 filter assembly For each surface, the calculated conversion factors allowed inferences on 137 Cs activity on interior surfaces based on exterior contact measurements of the 662 keV photopeak count rate. The MCNP calculations included the effect of attached collimators (i.e. either a Pb/Sb-based Ludlum or a W-based “Rees” model) on detector response. As a consequence, the conversion factors only apply to the appropriate collimated 2”x2” NaI detector operated in pulse height analysis (PHA) mode. Other assumptions affecting the calculations and valid application of the conversion factors will be outlined below.

54 ENVIRONMENTAL SCIENCES↗

Evaluation report on the Thermo Scientific TruDose (neutron,gamma) EPD3

This report summarizes an evaluation study on the Thermo Scientific TruDose n/γ EPD3 by LANL’s RP-SVS group. Two EPD3s were received for assessment (SNs 7500100 and 7500108) along with an EPD3 desktop reader. The evaluation included intercomparisons with Thermo’s N2 EPD which is in wide circulation at LANL but is no longer commercially available. A favourable assessment of the TruDose EPD3 would help support it as a viable option to replace the N2 EPD. The data and observations included in this report could also serve as the basis of a Technical Basis Document for the use of the EPD3 at LANL.

61 RADIATION PROTECTION AND DOSIMETRY↗