Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stainless Steel Coating Test Report

A process was developed to coat 316L stainless steel pieces having very low levels of fixed contamination on their surface (~100 dpm/100 cm²). The coating process served to significantly decrease the likelihood of any fixed contamination becoming loose contamination due to physical shocks. Prior to coating, the stainless steel was etched with a commercial methane sulfonic acid (MSA) solution in a heated ultrasonic bath, rinsed with deionized water, cleaned with a basic detergent solution, and then rinsed with deionized water. The MSA etched the surface of the stainless-steel pieces, creating a more favorable surface on which the coating could adhere. Due to the short timeline of the project, only commercially available clear coating products were considered. The clear coating had to be wear-resistant, shock resistant, radiation resistant, and have high adhesion to the surface of the stainless steel. Adhesion of coatings to stainless steel is notoriously difficult. A commercial, high molecular weight polymer coating was found that met these requirements. The adhesion properties of this coating to stainless steel are very good, and are significantly improved by the etching process. The etching process results in a higher surface area that is free of debris and other residues, making the surface much more wetable, and at the same time creating a favorable surface topography for adhesion. The polymer in its uncured form is a low viscosity liquid. It can be applied by brush or pipette, and it cures in air alone, but heat is required to speed up curing and attain the highest performance of the cured polymer. As the project progressed, the project team became interested in the composition of the selected commercial polymer coating, and in ways that this polymer coating could be made more wear resistant and potentially more radiation resistant. Nano-particle addition was chosen as the preferred way to achieve higher performance. Therefore, a series of tests were planned and performed. This report summarizes these tests, and presents the results.

36 MATERIALS SCIENCE↗

TEAMER: DAISY Flow-noise Testing (Abstract)

Evaluating impacts of marine energy devices is generally difficult given the dynamic environment where these devices need to be placed. The University of Washington’s (UW) DAISY (The Drifting Acoustic Instrumentation SYstem) is designed to measure radiated noise around marine energy converters operating in energetic waves and currents. In currents, a primary limitation for measurement fidelity at low frequencies (< 100 Hz) is the potential for non-propagating “flow-noise” to mask propagating sound and inflate estimates of the radiated noise from marine energy converters at frequencies that overlap with hearing sensitivities of fish and some marine mammals. While free-drifting measurements help to minimize the relative velocity that produces flow-noise, significant levels were still observed during initial DAISY tests. This motivated the development of a fabric “flow shield” around the hydrophone that disrupts both flow-noise generation mechanisms proposed by the initial tests. First, the flow shield is a source of substantial drag which keeps the hydrophone package moving with the approximate velocity of the surrounding water, compensating for differential wind or current forcing on the surface expression. By minimizing relative velocity around the hydrophone, turbulence shed by the hydrophone is also minimized. Second, the flow shield creates a largely quiescent pocket around the hydrophone, minimizing advection of free stream turbulence over the hydrophone element. Field data collected in these experiments will test effectiveness of these flow shields and provide quantitative data use and deployment.

16 TIDAL AND WAVE POWER↗

HTGR Multiphysics Application Drivers FY26 Updates

This report summarizes FY26 progress under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program's high-temperature gas-cooled reactor (HTGR) application driver work, covering a wide range of activities such as code validation and multi-physics code assessment. 1) A detailed SAM model of the High-Temperature Engineering Test Reactor (HTTR) was developed using a unique-block grouping approach, with an extended parallel thermal network method to capture block-to-block conduction and radiation heat transfer, and applied to steady-state simulations of the HTTR 30~MW and 9~MW cases. 2) In another activity, SAM's newly implemented multi-component gas flow model was validated against the Natural convection Shutdown heat removal Test Facility (NSTF) argon ingress experiment, correctly capturing the density-driven suppression and thermal recovery of natural circulation observed when argon is introduced into the air-cooled Reactor Cavity Cooling System (RCCS) loop. 3) For the OECD/NEA High Temperature Test Facility (HTTF) benchmark, we co-led the international benchmark activities as well as the OECD/NEA final benchmark report to be released at the end of this year. 4) Finally, the coupled Griffin-SAM modeling capability for pebble-bed HTGRs was advanced by verifying the Griffin neutronics solution against Serpent Monte Carlo for a realistic non-uniform temperature distribution, resolving several deficiencies in the SAM-to-Griffin temperature transfer scheme, and enabling distinct fuel kernel, moderator, and coolant temperatures for cross section feedback. These new features were demonstrated in a PBR load-following transient.

Lee, Alvin↗

Forward Pixel Detector for the Phase 2 Upgrade of CMS And Module Testing at UIC

High-Luminosity Large Hadron Collider (HL-LHC) upgrade aims to increase performance. In order to efficiently handle the larger particle flux and increased radiation, an upgrade is planned for the inner Tracker of the Compact Muon Solenoid (CMS) detector, which is located at the innermost part of the CMS. To efficiently reconstruct and track particles, the existing pixel tracker will be upgraded with novel sensors, readout chips, and front-end electronics designed to handle increased data rates. These improvements will allow the detector to track particles more precisely. In the United States, we are working on assembling new sensor modules to be inserted into disks, referred to as TFPX, for installation in the CMS detector for the HL-LHC era. We are currently testing the prototype of TFPX modules to ensure the upgrade is carried out in the best way possible. The University of Ilinois Chicago has been tasked with testing the final versions of the TFPX sensor modules before they are sent to CERN to be installed into the CMS detector. This work is supported by NSF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The distinct conditions of atmospheric and underground nuclear tests revealed by Zn isotopic compositions of nuclear debris samples

We analyzed the Zn isotopic compositions of nuclear debris samples from atmospheric and underground nuclear tests. Samples from the site of atmospheric tests exhibit a range of Zn isotopic fractionation (δ 66 Zn JMC-Lyon = 0.23–0.86 ‰) while samples from underground tests exhibit Zn isotopic compositions with minimal variation among samples and from terrestrial igneous rock standards (δ 66 ZnJMC-Lyon = 0.28–0.39 ‰). In conclusion, the larger range of δ 66 Zn JMC-Lyon observed in atmospheric test samples relative to underground test samples is likely the result of the open system characteristics of atmospheric nuclear tests and the closed system characteristics of underground nuclear tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Update on 17 O evaluation and fast neutron evaluation for 181 Ta [Slides]

Reliable fast-neutron evaluation can be entirely encapsulated in the reaction model and related input. Ta181 is a particularly relevant case due to extraordinary coverage of various observables by differential experiments that offer much help and relatively little headache. Differences from the similar ENDF/B-VIII evaluation are as follows: more advanced modeling (CC OMP, MSD, MSC, decay schemes), more careful selection of models and parameters, new experimental data, and isomers. Overall, there is improved agreement with differential data and hints of better performance in integral testing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

State of the art, gaps, and prospects in fusion materials theory and modelling

Advancing the theory and simulation of materials for fusion applications remains a key component of global roadmaps aimed at delivering much-needed fusion power. Especially as the drive for commercial application increases, prototypes must be designed against radiation damage before the relevant experimental data can be collected and cost reductions that are possible by testing materials in silico become even more important. Here, we summarise the state of the art as it emerged during the 7 th Fusion Materials Theory & Modelling Workshop that took place in 2024, with the aim to highlight present gaps and future directions for the fusion materials modelling community. Of particular interest were the effects of transmutations, chemical complexity with the development of novel alloys and interatomic potentials, advancements in modelling high-dose microstructures, comparison with experimental data and multiscale models for structural assessment relying on high-performance computing and virtual reality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing the Jump Finding Code for NEXUS Qubit Analysis

At Fermilab, the NEXUS dilution refrigerator is repeating the same experiment from Wilen et al. 1 underground to further investigate the effect of ionizing radiation and cosmic ray muons on qubit decoherence. This refrigerator is 100m underground in the MINOS cavern to significantly lower the incident rate of cosmic ray muons, meaning the majority of incidents is due to ionizing radiation. To gain a better understanding of how the rate of ionizing radiation affects the qubits, we use 4 radiation configurations to collect data from the chip. In this work, we examine the efficiency of our jump detection code to find jumps of various sizes. We do so using simulated data with a known number of injected jumps of known sizes. These jumps are charge offsets of the qubit, thought to be due to quasiparticle poisoning. To test this, we run the jump finding code on an array of simulated data in which two main parameters, the smoothing factor and the threshold at which a charge offset is considered a jump, are changed to test an array of these parameters. We then perform a χ2 analysis to find the best combination of these two parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance characterization and modeling of an oscillating surge wave energy converter

Abstract Testing wave energy converters in the ocean could be expensive and complex, which necessitates the use of numerical modeling. However, accurately modeling the response of wave energy converters with high-fidelity simulations can be computationally intensive in the design stage where different configurations must be considered. Reduced-order models based on simplified equations of motion can be very useful in the design, optimization, or control of wave energy converters. Given the complex dynamics of wave energy converters, accurate representation, and evaluation of relative contributions by different forces are required. This effort is concerned with a performance characterization of the hydrodynamic response of an oscillating surge wave energy converter that is based on a reduced-order model. A state-space model is used to represent the radiation damping term. Morison’s representation of unsteady forces is used to account for the nonlinear damping. Wave tank tests are performed to validate simulations. A free response simulation is used to determine the coefficients of the state-space model. Torque-forced simulations are used to identify the coefficients of the nonlinear damping term for different amplitudes and wave frequencies. The impact of varying these coefficients on the response is investigated. An assessment of the capability of the model in predicting the hydrodynamic response under irregular forcing is performed. The results show that the maximum error is 3% when compared with high-fidelity simulations. It is determined that the nonlinear damping is proportional to the torque amplitude and its effects are more pronounced as the amplitude of the flap oscillations increases.

16 TIDAL AND WAVE POWER↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Effect of Quartz Aperture Covers on the Fluid Dynamics and Thermal Efficiency of Falling Particle Receivers

Falling particle receivers are an emerging technology for use in concentrating solar power systems. In this paper, quartz half-shells are investigated for use as full or partial aperture covers to reduce receiver thermal losses. Quartz half-shell aperture covers offer the ability to minimally interfere with incoming solar radiation from the heliostat field while obstructing thermal radiation and advection from leaving the receiver cavity. The fluid dynamics and heat transfer of a receiver subdomain and surrounding air are modeled using ANSYS®FLUENT We compare the percentage of total incident solar power lost due to conduction through the receiver walls, advective losses through the aperture, and radiation exiting the aperture. Contrary to expected outcomes, results show that quartz aperture covers can increase radiative losses and result in modest to nonexistent reductions in advective losses. The increased radiative losses are driven by elevated quartz half-shell temperatures and have the potential to be mitigated by active cooling and/or material selection. Quartz half-shell total transmissivity was measured experimentally using a radiometer and the National Solar Thermal Test Facility heliostat field with values up to 0.97 ± 0.01. Quartz half-shell aperture covers did not yield expected efficiency gains in numerical results due to increased radiative losses, but efficiency improvement in some numerical results and the performance of quartz half-shells subject to concentrated solar radiation suggest that quartz half-shell aperture covers should be investigated further.

14 SOLAR ENERGY↗

Degradation in Photovoltaic Encapsulant Transmittance: Results of the Second PVQAT TG5 Artificial Weathering Study

The optical degradation of encapsulants from ultraviolet (UV) radiation has historically resulted in a significant loss in performance throughout the life of a photovoltaic (PV) module. International Electrotechnical Commission (IEC) test methods have recently been developed to screen for PV encapsulants prone to loss in optical performance. The present study was performed to benchmark polymeric packaging materials relative to IEC 62788-1-4 (covering the measurement of optical transmittance) and IEC 62788-1-7 (on the durability of transmittance), provide feedback toward improvement of the methods, and develop insight regarding optical degradation. Contemporary materials were examined, including poly(ethylene-co-vinyl acetate) (EVA), thermoplastic polyolefin (TPO), polyolefin elastomer (POE), and polyvinyl butyral (PVB) encapsulants; a poly(ethene-co-tetrafluoroethene)/poly(ethylene terephthalate) (ETFE/PET) transparent backsheet; and a polystyrene (PS) working reference material. The use of silica-, specialty-, and rolled-glass was also compared in laminated coupons. Specimen size was separately examined from 2.5 to 12.5 cm. Weathering was performed with a xenon source, using IEC TS 62788-7-2 methods A2, A3, A4, and A5 (chamber temperature of 55 degrees C, 65 degrees C, 75 degrees C, or 85 degrees C), respectively. Characterizations were made using a UV-visible-near-infrared (UV-VIS-NIR) spectrophotometer (transmittance and reflectance, with and without an integrating sphere), a UV-VIS fluorescence spectrophotometer, a camera, and an optical microscope. Performance was analyzed, including solar weighted transmittance, yellowness index, UV cut-off wavelength, and haze (scattering). Separate Arrhenius analyses were performed to assess retention of transmittance and changes in yellowness index. The activation energy for both characteristics was found to range from 15-80 kJ mol-1, with an average of 48 kJ mol-1, similar to the average of 45 kJ mol-1 identified in the previous international PV Quality Assurance Task Force (PVQAT) Task Group 5 (TG5) study of more traditional encapsulants. The separate degradation modes of discoloration and scattering were distinguished in the encapsulants using a comprehensive spectral characterization. Based on these results, the IEC 62788-1-7 pass/fail criteria of 5% change in transmittance was confirmed to identify a known bad encapsulant.

durability↗