RF ion mass spectrometer calibration ion source system Final report, Oct. 1964 - Mar. 1968
Plasma-ion source system for ground calibration of Bennett RF ion mass spectrometer
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Plasma-ion source system for ground calibration of Bennett RF ion mass spectrometer
As NASA proceeds with plans for increased science data return and higher data transfer capacity for science missions, both RF and optical communications are viable candidates for significantly higher-rate communications from deep space to Earth. With the inherent advantages, smaller apertures and larger bandwidths, of optical communications, it is reasonable to expect that at some point in time and combination of increasing distance and data rate, the rapidly emerging optical capabilities would become more advantageous than the more mature and evolving RF techniques. This paper presents a comparison of the burden to a spacecraft by both RF and optical communications systems for data rates of 10, 100, and 1000 Mbps and large distances. Advanced technology for RF and optical communication systems have been considered for projecting capabilities in the 2020 timeframe. For the comparisons drawn, the optical and RF ground terminals were selected to be similar in cost. The RF system selected is composed of forty-five 12-meter antennas, whereas the selected optical system is equivalent to a 10-meter optical telescope. Potential differences in availability are disregarded since the focus of this study is on spacecraft mass and power burden for high-rate mission data, under the assumption that essential communications will be provided by low-rate, high availability RF. For both the RF and optical systems, the required EIRP, for a given data rate and a given distance, was achieved by a design that realized the lowest possible communications subsystem mass (power + aperture) consistent with achieving the lowest technology risk. A key conclusion of this paper is that optical communications has great potential for high data rates and distances of 2.67 AU and beyond, but requires R&D and flight demonstrations to prove out technologies.
The SLAC National Accelerator Laboratory is planning an upgrade (LCLS-II) to the Linear Coherent Light Source with a 4 GeV CW Superconducting Radio Frequency (SCRF) linac. The nature of the machine places stringent requirements in the Low-Level RF (LLRF) system, expected to control the cavity fields within 0.01 degrees in phase and 0.01% in amplitude, which is equivalent to a longitudinal motion of the cavity structure in the nanometer range. This stability has been achieved in the past but never for hundreds of superconducting cavities in Continuous-Wave (CW) operation. The difficulty resides in providing the ability to reject disturbances from the cryomodule, which is incompletely known as it depends on the cryomodule structure itself (currently under development at JLab and Fermilab) and the harsh accelerator environment. Previous experience in the field and an extrapolation to the cavity design parameters (relatively high Q_{L}c≈ 4×10⁷ , implying a half-bandwidth of around 16 Hz) suggest the use of strong RF feedback to reject the projected noise disturbances, which in turn demands careful engineering of the entire system.
Savannah River National Laboratory (SRNL) performed pilot-scale hydraulic/chemical testing of spherical resorcinol formaldehyde (RF) ion exchange (IX) resin for the River Protection Project-Hanford Tank Waste Treatment & Immobilization Plant (WTP) Project. The RF resin hydraulic cycle testing was conducted in two pilot-scale IX columns, 1/4 and 1/2 scale. A total of twenty-three hydraulic/chemical cycles were successfully completed on the spherical RF resin. Sixteen of these cycles were completed in the 24-inch IX Column (1/2 scale column). Hydraulic testing showed that the permeability of the RF resin remained essentially constant, with no observed trend in the reduction of the permeability as the number of cycles increased. The permeability during the pilot-scale testing was 3 times better than the design requirements of the WTP full-scale IX system. The RF resin bed showed no tendency to form fissures or pack more densely as the number of cycles increased. Particle size measurements of the RF resin showed no indication of particle size change (for a given chemical) with cycles and essentially no fines formation. The permeability of the resin bed was uniform with respect to changes in bed depth. Upflow Regeneration and Simulant Introduction in the IX columns revealed another RF resin benefit; negligible radial pressures to the column walls from the swelling of resin beads. The hydraulic and chemical performance of the spherical RF resin during cycle testing was found to be superior to all other tested IX resins. The pilot-scale testing indicates that the RF resin is durable and should hold up to many hydraulic cycles in actual radioactive Cesium (Cs) separation.
A system to heat electrons and possibly drive off-axis field-aligned current is under development on the Madison Symmetric Torus RFP. Staged experiments have reached an input power of 150 kW at 3.6G Hz and have produced a localized increase in SXR emission during rf injection. This measured emission is consistent with modeling in its location, energy spectrum and dependence on radial diffusion within the plasma. The emission is strongest in the region where ray tracing predicts deposition of the injected power. The multi-chord SXR camera used is sensitive to 4-7 keV photons. Enhanced emission in this energy range is consistent with Fokker-Plank modeling of EBW injection. The enhanced SXR emission vanishes quickly when radial diffusion in the plasma is high (as indicated by m = 0 magnetic activity); this is also consistent with Fokker-Plank modeling. An increase of boron emission (and presumably boron within the plasma) is also observed during EBW injection. This presents an alternative explanation to the enhanced SXR emission. Subsequent experiments with a different antenna at 100 kW input showed a small increase in SXR emission near 3 keV. A higher frequency experiment (5.5 GHz) with more input power available is currently under construction. Initial tests are centered on a circular waveguide launcher which requires only a 5 cm circular port in the vacuum vessel and has a target launch power of 400 kW.
Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMICs to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMICs is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. For the more distant future pseudomorphic indium gallium arsenide (InGaAs) and other advanced III-V materials offer the possibility of MMIC subsystems well up into the millimeter wavelength region. All of these technology elements are in NASA's MMIC program. Their status is reviewed.
Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMIC's to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMIC's is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. In this paper, current developments in GaAs MMIC technology are described, and the status and prospects of the technology are assessed.
Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMIC's to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMIC's is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. For the more distant future pseudomorphic indium gallium arsenide (InGaAs) and other advanced III-V materials offer the possibility of MMIC subsystems well up into the millimeter wavelength region. All of these technology elements are in NASA's MMIC program. Their status is reviewed.
The PEP-II B-Factory collider ended the final phase of operation at nearly twice the design current and 4X the design luminosity. To highlight the evolution from the original conceptual design through to the 1.2E34 final machine we choose one example each from the broadband feedback and from the LLRF system. They illustrate the original design estimation missed some very significant details, and how in the course of PEP-II operation unexpected difficulties led to significant insights and new approaches which allowed higher machine performance. We present valuable 'lessons learned' which are of interest to designers of next generation feedback and impedance controlled LLRF systems.
In calculating the strengths of depolarizing resonances it may be convenient to reformulate the equations of spin motion in a coordinate system based on the actual trajectory of the particle, as introduced by Kondratenko, rather than the conventional one based on a reference orbit. It is shown that resonance strengths calculated by the conventional and the revised formalisms are identical. Resonances induced by radiofrequency dipoles or solenoids are also treated; with rf dipoles it is essential to consider not only the direct effect of the dipole but also the contribution from oscillations induced by it.
Minimizing beam trip rates is one of the key operational goals at the Spallation Neutron Source (SNS). Trip rates are closely monitored, and real-time statistics are kept during beam operations for immediate analysis. Beam trips are automatically binned by the length of the trip along with the cause for each trip. The shortest beam trips occur with the highest frequency and those trip rates are dominated by the room temperature RF structures. There can be many causes for the RF structure malfunctions, but one area that has had a major impact on trip rates is improvement in how RF processing is done on structures after extended maintenance periods. Details about the improvement in RF conditioning will be discussed.
A critical gradient for long wavelength (k{sub θ}ρ{sub s}≲0.4) electron temperature fluctuations has been observed in an experiment in the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)], where below a threshold value of L{sub T{sub e}{sup −1}}=|∇T{sub e}|/T{sub e} electron temperature fluctuations are constant and above they steadily increase. Above the critical gradient, the electron heat flux inferred by power balance also increases rapidly. Critical gradients are a predicted attribute of turbulence arising from linear instabilities and are thought to be related to transport stiffness. The presented results are the first direct, systematic demonstration of critical gradient behavior in turbulence measurements in a tokamak. The experiment was performed by changing the deposition location of electron cyclotron heating shot-to-shot to locally scan L{sub T{sub e}{sup −1}} at r/a = 0.6 in L-mode plasmas; rotation was also varied by changing the momentum input from neutral beam injection. Temperature fluctuations were measured with a correlation electron cyclotron emission (CECE) radiometry system. In addition to the CECE measurements, an array of turbulence measurements were acquired to characterize fluctuations in multiple fields and at multiple scales as L{sub T{sub e}{sup −1}} and rotation were modified: long wavelength (k{sub θ}ρ{sub s}≲0.5) density fluctuations were acquired with beam emission spectroscopy, the phase angle between electron temperature and density fluctuations was measured by coupling the CECE system and a reflectometer, intermediate scale (k{sub θ}ρ{sub s}∼0.8) density fluctuations were measured with a Doppler backscattering (DBS) system, and low frequency flows were also measured with DBS. The accumulated measurements and trends constrain identification of the instability responsible for the observed critical gradient to the ∇T{sub e}-driven trapped electron mode.
A document describes a high-performance, modular, and state-of-the-art Command and Data Handling (C&DH) system developed for use on the Lunar Reconnaissance Orbiter (LRO) mission. This system implements a complete hardware C&DH subsystem in a single chassis enclosure that includes a processor card, 48 Gbytes of solid-state recorder memory, data buses including MIL-STD-1553B, custom RS-422, SpaceWire, analog collection, switched power services, and interfaces to the Ka-Band and S-Band RF communications systems. The C&DH team capitalized on extensive experience with hardware and software with PCI bus design, SpaceWire networking, Actel FPGA design, digital flight design techniques, and the use of VxWorks for the real-time operating system. The resulting hardware architecture was implemented to meet the LRO mission requirements. The C&DH comprises an enclosure, a backplane, a low-voltage power converter, a single-board computer, a communications interface board, four data storage boards, a housekeeping and digital input/output board, and an analog data acquisition board. The interfaces between the C&DH and the instruments and avionics are connected through a SpaceWire network, a MIL-STD-1553 bus, and a combination of synchronous and asynchronous serial data transfers over RS-422 and LVDS (low-voltage differential-signaling) electrical interfaces. The C&DH acts as the spacecraft data system with an instrument data manager providing all software and internal bus scheduling, ingestion of science data, distribution of commands, and performing science operations in real time.
RF Sputtering system is one of the Physical Vapour Deposition (PVD) methods that have been widely used to produce hard coating. This technique is used to deposit thin layers of metallic substrates such as stainless steel (SS). From this process, a good adhesiveness and wear resistance coating can be produced for biomedical applications. In this study, RF sputtering method was used to deposit TiO{sub 2}-Ag composite coatings via various deposition parameters. The parameters are RF power of 350W, gas composition (Ar: O{sub 2}) 50:5 and deposition time at 1, 2, 4 and 6 hours. Scanning Electron Microscopy (SEM), X-Ray Diffraction (XRD) and Raman spectroscopy were used to characterize surface area of coated samples. The formation of nanocrystalline thin film and the surface morphology were examined using SEM. The crystallite size of TiO{sub 2}-Ag composite coatings were estimated between 20-60 nm based on XRD analysis using Scherer equation and SEM evaluation. The Raman and XRD results suggested that the structure of the TiO{sub 2}-Ag consist of anatase and rutile phases. It also showed that the intensity of anatase peaks increased after samples undergone annealing process at 500 Degree-Sign C.
We have developed an all-permanent magnet large bore electron cyclotron resonance ion source (ECRIS) for broad ion beam processing. The cylindrically comb-shaped magnetic field configuration is adopted for efficient plasma production and good magnetic confinement. To compensate for disadvantages of fixed magnetic configuration, a traveling wave tube amplifier (TWTA) is used. In the comb-shaped ECRIS, it is difficult to achieve controlling ion beam profiles in the whole inside the chamber by using even single frequency-controllable TWTA (11-13GHz), because of large bore size with all-magnets. We have tried controlling profiles of plasma parameters and then those of extracted ion beams by launching two largely different frequencies simultaneously, i.e., multi-frequencies microwaves. Here we report ion beam profiles and corresponding plasma parameters under various experimental conditions, dependence of ion beams against extraction voltages, and influence of different electrode positions on the electron density profile.
A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.
Reported here is the design, construction, and characterization of a small, power efficient, tunable dielectric filled cavity for the creation of femtosecond electron bunches in an existing electron microscope without the mandatory use of femtosecond lasers. A 3 GHz pillbox cavity operating in the TM{sub 110} mode was specially designed for chopping the beam of a 30 keV scanning electron microscope. The dielectric material used is ZrTiO{sub 4}, chosen for the high relative permittivity ({epsilon}{sub r}= 37 at 10 GHz) and low loss tangent (tan {delta}= 2 x 10{sup -4}). This allows the cavity radius to be reduced by a factor of six, while the power consumption is reduced by an order of magnitude compared to a vacuum pillbox cavity. These features make this cavity ideal as a module for existing electron microscopes, and an alternative to femtosecond laser systems integrated with electron microscopes.
This study extensively measured the uniformity of an electron cyclotron resonance (ECR) plasma versus the magnetic field distribution. The influence of magnetic field distribution on the generation of uniform ECR plasma was examined. It is suggested that in addition to the uniformity of the magnetic field distribution at ECR zone and at the downstream zone near the substrate, the transition of the magnetic field between these two zones is also crucial. A uniform ECR plasma with the electron density uniformity of ±7.7% over 500 × 500 mm{sup 2} was measured at the downstream. The idea of generating uniform ECR plasma can be scaled up to a much larger area by using an n × n microwave input array and a well-designed magnetic system.