Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Variable Refrigerant Flow Performance: Humidity and Efficiency in Multifamily Buildings in New York, NY

Variable refrigerant flow (VRF) systems have become common in large multifamily buildings. The upfront cost is appealing to developers, as a single system can provide all heating and cooling. VRF systems also use no on-site fossil fuels which can help avoid greenhouse gas emissions. However, there have been very few data on how VRF systems actually perform in buildings. Researchers monitored three new, multifamily buildings with a focus on VRF system sizing, humidity control, and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems

With the current movement toward net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings

Variable air volume (VAV) and variable refrigerant flow (VRF) systems are widely used in office buildings. This study investigated VAV and VRF systems in five typical office buildings in China, and compared their cooling energy use. Site survey and field measurements were conducted to collect the data of building characteristics and operation. Measured cooling electricity use was collected from sub-metering in the five buildings. The sub-metering data normalized by climate and operating hours indicated that the cooling energy consumed by VRF systems was up to 70% lower than that consumed by VAV systems. This was mainly because of the different operation modes of both system types that led to significantly fewer operating hours for the VRF systems. Building simulations were used to quantify the impact of operation modes of VRF and VAV systems on cooling loads. A prototype office building in China was used as the model. The simulation results showed that the VRF operation mode required much lower cooling load when compared to the VAV operation mode. For example, the cooling loads decreased by 42% in Hong Kong and 53% in Qingdao. Key findings include the following: the VRF systems operated in the part-time-part-space mode enabling occupants to turn on the air-conditioning only when needed and when the spaces were occupied. However, the VAV systems operated in the full-time-full-space mode limiting occupants’ control of operation. These findings provide insights into VRF systems operation and controls as well as their energy performance, which could help guide HVAC designers on system selection and building operators or facility managers on system operations to achieve low- or zero-net energy buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of energy savings potential of variable refrigerant flow (VRF) from variable air volume (VAV) in the U.S. climate locations

Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assess the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated supermarket refrigeration for very high ambient temperature

This paper analytically investigates and compares the performance of a proposed ‘all-natural’ NH 3 /CO 2 cascaded booster system to a conventional R404A direct expansion system as well as to an ‘all-CO 2 ’ system with multi-ejector unit and flooded evaporator. Performance comparison is made based on the annual combined COP and Life Cycle Climate Performance (LCCP) for operation in selected cities of Middle East and India. Our results show that in extreme warm climate, the energy efficiency of the proposed configuration exceeds that of all-CO 2 configuration by a maximum of about 12.23% and the total emissions are lower by up to 11.20%. However, the all-CO 2 multi ejector system performs better in cold and mild warm climate. In the NH 3 /CO 2 cascade, the high temperature NH 3 system can be designed to be isolated from the accessible locations of the supermarket. Here, the work presented is expected to help adoption of natural refrigerants such as CO 2 and NH 3 for commercial application in extreme warm climate conditions prevailing in many cities of Middle East and India.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization and numerical simulation of liquid refrigerant R-134a flow emerging from a flooded evaporator tube bundle

The distribution of liquid droplets emerging from an evaporator tube bundle is characterized for refrigerant R-134a with a triangular tube arrangement with a pitch of 1.167. The purpose of this research was to improve understanding of the droplet ejection process to aid in design of evaporators typically used in larger chiller systems. A laser and camera system captured images of the evaporator headspace at varying conditions. Conventional shadowgraphy techniques were applied to recognize and match droplets for velocity calculations. The evaporator conditions varied with bundle mass fluxes of 20.3 and 40.7 kg s -1 m -2 , top-rows heat fluxes of 15.8 and 31.5 kWm -2 , and outlet saturation temperatures of 4.4 and 12.8 °C. Conditions ranged from flooded to dryout of the top rows. Droplet number, size distribution, velocity, and liquid volume fraction are presented in the headspace above the bundle. A method to numerically duplicate the droplet loading in the headspace using CFD with a Lagrangian discrete-phase model is also presented and verified, providing a powerful design tool. Liquid distribution in the headspace is found to be a strong function of all varied properties, particularly mass flux, liquid level, and saturation temperature

42 ENGINEERING↗

Evaluation of HVAC & refrigeration system fault behaviors and impacts: A systematic review

Achieving the goals of green buildings critically depends on the fault-free operation of heating, ventilation and air conditioning and refrigeration (HVAC&R) systems. However, faults frequently occur in these systems, causing a range of negative consequences, including increased energy consumption, diminished operational performance, compromised indoor environmental quality, higher operational costs, and shortened system lifespan. The evaluation of fault behaviors and impacts plays a critical role in revealing fault characteristics and consequently supports many research areas, including the design of the high-performance equipment, development of fault detection and diagnostics (FDD) and robust control approaches, as well as the enhancement of maintenance decision-making activities. This paper systematically reviews 112 research publications that reported the analysis and evaluation of fault behaviors and impacts in HVAC&R systems over the past thirty years. Here, we designed a review approach to address five crucial research questions, namely: 1) the objectives of analysis and evaluation of fault behaviors and impacts, 2) data sources, 3) equipment/system types and fault types, 4) evaluation methods including evaluation measures and associated metrics, and 5) challenges and future directions in the research on evaluating of fault behaviors and impacts. In-depth discussions on these questions help bridge the gap between the evaluation of fault behaviors and impacts and their practical applications, such as the development of high-performance systems, fault models, FDD methods, and maintenance decision-making tools within the HVAC&R FDD domain.

Chen, Yimin [Oak Ridge National Laboratory (ORNL),↗

A numerical analysis of a magnetocaloric refrigerator with a 16-layer regenerator

A numerical analysis was conducted to study a room temperature magnetocaloric refrigerator with a 16-layer parallel plates active magnetic regenerator (AMR). Sixteen layers of LaFeMnSiH having different Curie temperatures were employed as magnetocaloric material (MCM) in the regenerator. Measured properties data was used. A transient one dimensional (1D) model was employed, in which a unique numerical method was developed to significantly accelerate the simulation speed of the multi-layer AMR system. As a result, the computation speed of a multi-layer AMR case was very close to the single-layer configuration. The performance of the 16-layer AMR system in different frequencies and utilizations has been investigated using this model. To optimize the layer length distribution of the 16-layer MCMs in the regenerator, a set of 137 simulations with different MCM distributions based on the Design of Experiments (DoE) method was conducted and the results were analyzed. The results show that the 16-layer AMR system can operate up to 84% of Carnot cycle COP at a temperature span of 41 K, which cannot be obtained using an AMR with fewer layers. Here, the DoE results indicate that for a 16-layer AMR system, the uniform distribution is very close to the optimized design.

36 MATERIALS SCIENCE↗

High-performance near-field electroluminescent refrigeration device consisting of a GaAs light emitting diode and a Si photovoltaic cell

We consider a near-field electroluminescent refrigeration device. The device uses a GaAs light emitting diode as the cold side, and a Si photovoltaic cell as the hot side. The two sides are brought in close proximity to each other across a vacuum gap. The cooling is achieved by applying a positive bias on the GaAs light emitting diode. We show that the choice of GaAs and Si here can suppress the non-idealities for electroluminescent cooling purposes: GaAs has a wide bandgap with low Auger recombination, and Si is a non-polar semiconductor which leads to significantly reduced sub-bandgap heat transfer. We show that by using this configuration in the near-field regime, the cooling power density can reach 10 5 W/m 2 even in the presence of realistic Auger recombination and Shockley-Read-Hall recombination. In addition, with photovoltaic power recovery from the Si cell, the efficiency of the device can be further improved. Our work points to the significant potential of combining near-field heat transfer with active semiconductor devices for the control of heat flow.

14 SOLAR ENERGY↗

Mixture Model for Refrigerant Pairs R-32/1234yf, R-32/1234ze(E), R-1234ze(E)/227ea, R-1234yf/152a, and R-125/1234yf

In this work, thermodynamic models based on the corresponding states framework with departure terms are developed for the refrigerant pairs R-32/1234yf, R-32/1234ze(E), R-1234ze(E)/227ea, R-1234yf/152a, and R-125/1234yf. These models are based on new measurements of density, speed of sound, and phase equilibria, combined with the data available in the literature. The model for R-32/1234yf is most comprehensive in its data coverage, with speed of sound deviations within 1%, density deviations within 0.1%, and bubble- and dew-point pressure deviations within 1%. In conclusion, the other mixtures have generally more limited data availability but a similar goodness of fit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementing microwave impedance microscopy in a dilution refrigerator

We report the implementation of a dilution refrigerator-based scanning microwave impedance microscope with a base temperature of ∼100 mK. The vibration noise of our apparatus with tuning-fork feedback control is as low as 1 nm. Using this setup, we have demonstrated the imaging of quantum anomalous Hall states in magnetically (Cr and V) doped (Bi, Sb)2Te3 thin films grown on mica substrates. Both the conductive edge modes and topological phase transitions near the coercive fields of Cr- and V-doped layers are visualized in the field-dependent results. Our study establishes the experimental platform for investigating nanoscale quantum phenomena at ultralow temperatures.

Instruments & Instrumentation↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LCLS-II Helium Refrigeration System : A comprehensive overview of the project

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting accelerator composed of 37 cryomodules and two large helium refrigeration systems with a total cooling capacity of 8 kW at 2.0 K. The cryogenic system at SLAC is the successful outcome of a nine-year partnership between SLAC, Fermilab, and Jefferson Lab. This paper highlights the joint efforts between Jefferson Lab and SLAC in the development and implementation of the LCLS-II Cryogenic Plants. It details the project organization, schedule, budget, staffing profile and procurement strategy.

42 ENGINEERING↗

Near-Field Enhanced Negative Luminescent Refrigeration

Here we consider a near-field enhanced negative luminescent refrigeration system made of a polar material supporting surface-phonon polariton resonances and a narrow-band-gap semiconductor under a reverse bias. We show that in the near-field regime, such a device yields significant cooling power density and a high efficiency close to the Carnot limit. In addition, the performance of our system still persists even in the presence of strong nonidealities such as Auger recombination and sub-band-gap thermal radiation from free carriers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser refrigeration of optically levitated sodium yttrium fluoride nanocrystals

Solid state laser refrigeration can cool optically levitated nanocrystals in an optical dipole trap, allowing for internal temperature control by mitigating photothermal heating. This work demonstrates cooling of ytterbium-doped cubic sodium yttrium fluoride nanocrystals to 252 K on average with the most effective crystal cooling to 241 K. The amount of cooling increases linearly with the intensity of the cooling laser and is dependent on the pressure of the gas surrounding the nanocrystal. Furthermore, cooling optically levitated nanocrystals allows for crystals prone to heating to be studied at lower pressures than currently achievable and for temperature control and stabilization of trapped nanocrystals

36 MATERIALS SCIENCE↗

Polysaccharide-based liquid storage and transport media for non-refrigerated preservation of bacterial pathogens

The preservation of biological samples for an extended time period of days to weeks after initial collection is important for the identification, screening, and characterization of bacterial pathogens. Traditionally, preservation relies on cold-chain infrastructure; however, in many situations this is impractical or not possible. Thus, our goal was to develop alternative bacterial sample preservation and transport media that are effective without refrigeration or external instrumentation. The viability, nucleic acid stability, and protein stability of Bacillus anthracis Sterne 34F2, Francisella novicida U112, Staphylococcus aureus ATCC 43300, and Yersinia pestis KIM D27 (pgm-) was assessed for up to 28 days. Xanthan gum (XG) prepared in PBS with L-cysteine maintained more viable F . novicida U112 cells at elevated temperature (40°C) compared to commercial reagents and buffers. Viability was maintained for all four bacteria in XG with 0.9 mM L-cysteine across a temperature range of 22–40°C. Interestingly, increasing the concentration to 9 mM L-cysteine resulted in the rapid death of S . aureus . This could be advantageous when collecting samples in the built environment where there is the potential for Staphylococcus collection and stabilization rather than other organisms of interest. F . novicida and S . aureus DNA were stable for up to 45 days upon storage at 22°C or 40°C, and direct analysis by real-time qPCR, without DNA extraction, was possible in the XG formulations. XG was not compatible with proteomic analysis via LC-MS/MS due to the high amount of residual Xanthomonas campestris proteins present in XG. Our results demonstrate that polysaccharide-based formulations, specifically XG with L-cysteine, maintain bacterial viability and nucleic acid integrity for an array of both Gram-negative and Gram-positive bacteria across ambient and elevated temperatures.

59 BASIC BIOLOGICAL SCIENCES↗