Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRACTIVE INDEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Optical Response of Soda-Lime Glass Shocked to 14 GPa

To investigate the potential use of soda-lime glass (SLG) as an optical window in shock wave experiments, laser interferometry (VISAR) was used to determine the window correction and the refractive index in SLG samples subjected to plane shock wave compression. Symmetric plate impact experiments were conducted at peak stresses varying between 4 and 14 GPa and laser interferometry ($λ_0$ = 532$\textit {nm}$ wavelength) measurements were used to monitor the particle velocity histories at the impact surface. The higher stress experiments displayed a constant state prior to stress unloading. In contrast, the lower stress experiments (4.3 and 7.8 GPa) displayed an initial constant state followed by weakly time-dependent response prior to stress unloading. Because the actual particle velocities were independently known from the projectile velocity measurements, the window correction factor and the refractive index changes were determined over the stress range examined. Above 7.5 GPa, our window correction and refractive index results show significant differences with previously published data for the same material. Potential reasons for these differences are indicated.

36 MATERIALS SCIENCE↗

Calibration of photoelastic modulator based dichrometers: maintaining constant phase across the spectrum

Photoelastic modulators can alter the polarization state of a beam of ultraviolet, visible or infrared photons by means of periodic stress-induced differences in the refractive index of a transparent material that forms the optical element of the device and is isotropic in the absence of stress. Furthermore, they have found widespread application in instruments that characterize or alter the polarization state of a beam in fields as diverse as astronomy, structural biology, materials science and ultraviolet lithography for the manufacture of nano-scale integrated circuits. Measurement of circular dichroism, the differential absorption of left- and right circularly polarized light, and of strain-induced birefringence of optical components are major applications. Instruments using synchrotron radiation and photoelastic modulators with CaF 2 optical elements have extended circular dichroism measurements down to wavelengths of about 130 nm in the vacuum ultraviolet. Maintaining a constant phase shift between two orthogonal polarization states across a spectrum requires that the amplitude of the modulated stress be changed as a function of wavelength. For commercially available photoelastic modulators, the voltage that controls the amplitude of modulation required to produce a specified phase shift, which is a surrogate for the stress modulation amplitude, has been shown to be an approximately linear function of wavelength in the spectral region where the optical element is transparent. But, extrapolations of such straight lines cross zero voltage at a non-zero wavelength, not at zero-wavelength. For modulators with calcium fluoride and fused silica optical elements, the zero-crossing wavelength is always in the spectral region where the optical element of the modulator strongly absorbs the incident radiation, and at a wavelength less than the longest-wavelength apparent resonance deduced from experimental values of the refractive index fit to the Sellmeier equation. Using a model that relates the refractive indices of a stressed optical element to the refractive index of its unstressed state, an expression for the modulator control voltage was derived that closely fits the experimental data. Our result provides a theoretical rational for the apparently linear constant-phase programming voltage, and thus provides theoretical backing for the calibration procedure frequently used for these modulators. Lastly there are other factors that can influence the calibration of a photoelastic modulator, including temperature and atmospheric pressure, are discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Blood Serum by the Method of Refractometry in Antitumor Therapy in Patients with Multiple Myeloma

The serum of patients with multiple myeloma was examined by refractometric methods before and after the course of antitumor therapy. It was found that the amount of protein in the serum of patients with multiple myeloma, determined by the value of the serum refractive index, tended to decrease after the course of treatment. The value of the refractive index of blood serum can be used as an additional criterion for assessing the dynamics of changes in blood-serum properties during antitumor therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of point defects in the photosensitivity of hydrogen-loaded phosphosilicate glass

It is shown that point defect modifications in hydrogen-loaded phosphosilicate glass (PSG) do not play a central role in determining its photosensitivity. Photochemical reactions that involve a two-step point defect modification and pre-exposure effect are incapable of accounting for photoinduced refractive index changes. It seems likely that a key role in UV-induced refractive index modifications is played by structural changes in the PSG network. Experimental data are presented that demonstrate intricate network rearrangement dynamics during UV exposure of PSG. (fiber optics)

36 MATERIALS SCIENCE↗

Preparation of Cu–Fe–O thin films via post oxidation of iron/copper bilayers: structural, optical and electrical properties

Cu–Fe–O thin films were prepared via vacuum thermal evaporation of Fe and Cu after what the obtained bilayer Fe\Cu was annealed in free air at different temperatures during 2 h. The obtained Cu–Fe–O thin films were characterized using X-ray diffraction (XRD), Scanning Electron Microscopy (SEM), electrical and spectrophotometric measurements. X-ray diffraction (XRD) analysis revealed the presence of Fe{sub 2}O{sub 3}, CuO and CuFeO{sub 2} phases. Cu–Fe–O thin films exhibit rough surfaces by analyzing the film morphologies by scanning electron microscopy. Energy dispersive spectroscopy (EDS) technique was used to evaluate Cu–Fe–O thin films stoichiometry. The optical properties reveal that the absorption coefficient of Cu–Fe–O thin films is larger than 10{sup 5} cm{sup −1} and two optical direct band gaps in the range 1.65–2.2 eV were found. The Wemple and DiDomenico model was used to study the dispersion of the refractive index in terms of the single oscillator model. So, optical parameters such as refractive index, extinction coefficient, oscillator energy and dispersion energy were calculated. In addition and by using the model of Spitzer and Fan, the electrical free carrier susceptibility and the carrier concentration on the effective mass ratio were evaluated. All the samples present relatively high electrical resistivity.

36 MATERIALS SCIENCE↗

Theory of terahertz pulse generation through optical rectification in a nonlinear optical material with a finite size

The full analytical solutions for plane terahertz waves generated through optical rectification in a slab of a nonlinear optical material are calculated. Terahertz dispersion, absorption of both optical and terahertz waves, and multiple reflections are considered. The results are valid for an arbitrary difference between the optical group index and the terahertz refractive index, including equal indices. It is demonstrated that the full terahertz wave is freely propagating and has no contribution of a 'forced' pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RSP Data Status, Updates and Plans from the Team

•All radiance (L1C), aerosol and cloud (L2) products are in the archive. •Revised calibration performed at GSFC in July 2021 applied to reprocessing. •Clouds have smaller drops and higher optical depths (larger droplet number concentrations) in winter than in summer. Cloud top droplet size distributions tend to be narrow with roughly 80% having an effective variance of less than 0.07. This is relevant to how well bulk auto-conversion parameterizations are likely to work at cloud top (order of magnitude effects) and also to assumptions used in the remote sensing of droplet number (~ 10% effect). Real refractive index and effective radius retrievals are consistent with hygroscopic growth of aerosols Real refractive index and effective variance retrievals imply the presence of an insoluble fraction of aerosols Future work on clouds will look at differences in cloud top drizzle formation and auto-conversion rates between the different campaigns and at how well mixed phase clouds can be detected (if at all) from sensors such as VIIRS and PACE OCI.

Research Scanning Polarimeter↗

Ground-based retrievals of aerosol column absorption in the UV spectral region and their implications for GEMS measurements

Quantifying the spectral variation of column aerosol absorption in the ultraviolet (UV) and visible (Vis) wavelengths is required for accurate satellite-based aerosol and trace-gas retrievals. Retrievals of the column-averaged imaginary part of refractive index and single scattering albedo (SSA) in the UV–Vis range have been performed at Yonsei University, Seoul, Korea, since 2016 by combining co-located measurements from the NASA Aerosol Robotic Network (AERONET) Cimel sun-sky photometer, the Ultraviolet Multifilter Rotating Shadowband Radiometer (UV-MFRSR), the SKYNET Prede sky radiometer, and the NASA Pandora sun spectrometer. We investigated the spectral variation of column-averaged imaginary part of refractive index for UV–Vis wavelengths to refine models used in our aerosol retrieval algorithm to process measurements from the upcoming Geostationary Environment Monitoring Satellite (GEMS). The retrieved imaginary part of refractive index for highly absorbing fine pollution particles (BC), dust (DS), and non-absorbing (NA) particles in the selected UV–Vis range (380–440 nm) showed 0–20%, 30%, and 0–40% of spectral dependence, respectively. Retrievals of Ozone Monitoring Instrument (OMI) measurement data using the improved aerosol model showed improved correlation with AERONET data compared to the old algorithm that did not properly account for aerosol absorption effects. These results corroborate the advantage of using local climatology derived from ground-based UV–Vis spectral aerosol absorption measurements for satellite GEMS aerosol retrievals over East Asia. Moreover, this study reveals that spectral variations in the UV column aerosol absorption in East Asia differ from those in other regions.

ultraviolet (UV) and visible (Vis) wavelengths↗

Optical Properties of Moderately-Absorbing Organic and Mixed Organic/Inorganic Particles at Very High Humidities

Relative humidity (RH) affects the water content of an aerosol, altering its ability to scatter and absorb light, which is important for aerosol effects on climate and visibility. This project involves in situ measurement and modeling of aerosol optical properties including absorption, scattering and extinction at three visible wavelengths (467, 530, 660 nm), for organic carbon (OC) generated by pyrolysis of biomass, ammonium sulfate and sodium chloride, and their mixtures at controlled RH conditions. Novel components of this project include investigation of: (1) Changes in all three of these optical properties at scanned RH conditions; (2) Optical properties at RH values up to 95%, which are usually extrapolated instead of measured; and (3) Examination of aerosols generated by the pyrolysis of wood, which is representative of primary atmospheric organic carbon, and its mixture with inorganic aerosol. Scattering and extinction values were used to determine light absorption by difference and single scattering albedo values. Extensive instrumentation development and benchmarking with independently measured and modeled values were used to obtain and evaluate these new results. The single scattering albedo value for a dry absorbing polystyrene microsphere benchmark agreed within 0.02 (absolute value) with independently published results at 530 nm. Light absorption by a nigrosin (sample light-absorbing) benchmark increased by a factor of 1.24 +/-0.06 at all wavelengths as RH increased from 38 to 95%. Closure modeling with Mie theory was able to reproduce this increase with the linear volume average (LVA) refractive index mixing rule for this water soluble compound. Absorption by biomass OC aerosol increased by a factor of 2.1 +/- 0.7 and 2.3 +/- 1.2 between 32 and 95% RH at 467 nm and 530 nm, but there was no detectable absorption at 660 nm. Additionally, the spectral dependence of absorption by OC that was observed with filter measurements was confirmed qualitatively in situ at 467 and 530 nm. Closure modeling with the dynamic effective medium approximation (DEMA) refractive index model was able to capture the increasing absorption trend with RH indicating that the droplets were heterogeneously mixed while containing dispersed insoluble absorbing material within those droplets. Seven other refractive index mixing models including LVA did not adequately describe the measurements for OC. Mixing the biomass OC aerosol with select mass fractions of ammonium sulfate ranging from 25 to 36% and sodium chloride ranging from 21 to 30% resulted in an increase in light scattering and extinction with RH and inorganic mass fraction. However, no detectable difference in light absorption behavior in comparison to pure biomass OC was observed. The main finding of this research is a measured increase in absorption with increasing RH, which is currently not represented in radiative transfer models even though biomass burning produces most of the primary OC aerosol in the atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Remote probing of atmospheric particulates from radiation extinction experiments: A review of methods

The existing methodology for reconstructing the particle size distribution and inferring the refractive index of absorbing and scattering atmospheric particulates is critically reviewed. Emphasis is placed on method capabilities and shortcomings and, wherever possible, on achievable accuracy. The nature of the associated remote probing problem is analyzed with regard to the effects of the particulates on EM wave propagation in the atmosphere. The parameterization of size distribution is studied within the unifying framework of Pearson's distribution curves. The inversions of extinction measurements and their ratios are considered separately, and the potentialities of each type of measurement are identified. Work lacking in each of the methods reviewed is indicated. A method of determining both the effective complex refractive index and size distribution model parameters from the same data is also presented. Lastly, determination from extinction ratio data of the complex refractive index independent of size distribution is discussed and error analyzed.

Fymat, A. L.↗

Gamma ray optics

Via refractive or diffractive scattering one can shape {gamma} ray beams in terms of beam divergence, spot size and monochromaticity. These concepts might be particular important in combination with future highly brilliant gamma ray sources and might push the sensibility of planned experiments by several orders of magnitude. We will demonstrate the experimental feasibility of gamma ray monochromatization on a ppm level and the creation of a gamma ray beam with nanoradian divergence. The results are obtained using the inpile target position of the High Flux Reactor of the ILL Grenoble and the crystal spectrometer GAMS. Since the refractive index is believed to vanish to zero with 1/E{sup 2}, the concept of refractive optics has never been considered for gamma rays. The combination of refractive optics with monochromator crystals is proposed to be a promising design. Using the crystal spectrometer GAMS, we have measured for the first time the refractive index at energies in the energy range of 180 - 2000 keV. The results indicate a deviation from simple 1/E{sup 2} extrapolation of X-ray results towards higher energies. A first interpretation of these new results will be presented. We will discuss the consequences of these results on the construction of refractive optics such as lenses or refracting prisms for gamma rays and their combination with single crystal monochromators.

43 PARTICLE ACCELERATORS↗

Solitary electromagnetic wave propagation in the asymmetric oppositely directed coupler

We consider electromagnetic waves propagating in the system of coupled waveguides. One of the system components is a standard waveguide fabricated from nonlinear material having positive refraction index and another component is a waveguide produced from an artificial material having negative refraction index. In this waveguide a wave propagates in the direction opposite to direction of energy flux. We suppose that constituting metamaterial has linear properties. It is found that the coupled nonlinear solitary waves propagating both in the same direction are exist in this oppositely directed coupler due to linear coupling between nonlinear positive refractive waveguide and linear negative refractive waveguide. The corresponding analytical solution is found and it is used for numerical simulation to illustrate that the results of the solitary wave collisions are sensible to the relative velocity of the colliding solitary waves. The effect of linear losses in negative refractive waveguide is considered numerically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Degradation of the contrast of a short light pulse in a CPA system

We have calculated the effect of four-wave mixing of the main radiation pulse with the background radiation components on the value of the output radiation contrast in a chirped pulse amplification system of petawatt laser facilities. Formulae are presented that make it possible to quantify the contributions of two mechanisms, i.e. Kerr nonlinearity of the refractive index of the amplifying medium and gain saturation. For typical values of the nonlinear refractive index, both contributions are comparable. The possibility of mutual quenching of nonlinear contributions is noted. The influence of spectral filtering of radiation on the output pulse contrast is considered. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical evaluation of droplet sizing based on the ratio of fluorescent and scattered light intensities (LIF/Mie technique)

The dependence of fluorescent and scattered light intensities from spherical droplets on droplet diameter was evaluated using Mie theory. The emphasis is on the evaluation of droplet sizing, based on the ratio of laser-induced fluorescence and scattered light intensities (LIF/Mie technique). A parametric study is presented, which includes the effects of scattering angle, the real part of the refractive index and the dye concentration in the liquid (determining the imaginary part of the refractive index). The assumption that the fluorescent and scattered light intensities are proportional to the volume and surface area of the droplets for accurate sizing measurements is not generally valid. More accurate sizing measurements can be performed with minimal dye concentration in the liquid and by collecting light at a scattering angle of 60 deg. rather than the commonly used angle of 90 deg. Unfavorable to the sizing accuracy are oscillations of the scattered light intensity with droplet diameter that are profound at the sidescatter direction (90 deg.) and for droplets with refractive indices around 1.4.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Ion-Beam Processing during RF Magnetron Sputtering on the properties of ZnO Films

The effect of ion-beam processing alternating with magnetron sputtering on the properties of zinc-oxide thin films is investigated. It is shown that ion-beam processing reduces the growth rate, coherent-scattering-region sizes, and the resistivity. The stoichiometric index, band gap, and refractive index increase. The transparency of the films in the weak absorption region remains unchanged.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Higher-order phase shift reconstruction approach

Purpose: Biological soft tissues encountered in clinical and preclinical imaging mainly consists of atoms of light elements with low atomic numbers and their elemental composition is nearly uniform with little density variation. Hence, x-ray attenuation contrast is relatively poor and cannot achieve satisfactory sensitivity and specificity. In contrast, x-ray phase-contrast provides a new mechanism for soft tissue imaging. The x-ray phase shift of soft tissues is about a thousand times greater than the x-ray absorption over the diagnostic x-ray energy range, yielding a higher signal-to-noise ratio than the attenuation contrast counterpart. Thus, phase-contrast imaging is a promising technique to reveal detailed structural variation in soft tissues, offering a high contrast resolution between healthy and malignant tissues. Here the authors develop a novel phase retrieval method to reconstruct the phase image on the object plane from the intensity measurements. The reconstructed phase image is a projection of the phase shift induced by an object and serves as input to reconstruct the 3D refractive index distribution inside the object using a tomographic reconstruction algorithm. Such x-ray refractive index images can reveal structural features in soft tissues, with excellent resolution differentiating healthy and malignant tissues. Methods: A novel phase retrieval approach is proposed to reconstruct an x-ray phase image of an object based on the paraxial Fresnel-Kirchhoff diffraction theory. A primary advantage of the authors' approach is higher-order accuracy over that with the conventional linear approximation models, relaxing the current restriction of slow phase variation. The nonlinear terms in the autocorrelation equation of the Fresnel diffraction pattern are eliminated using intensity images measured at different distances in the Fresnel diffraction region, simplifying the phase reconstruction to a linear inverse problem. Numerical experiments are performed to demonstrate the accuracy and stability of the proposed approach. Results: The proposed reconstruction formula is a generalization of the transport of intensity equation (TIE). It has the second-order accuracy compared to the linear model used in the conventional phase retrieval approach. The numerical experiments demonstrate that the accuracy and stability of the proposed phase reconstruction method outperforms the TIE-based reconstruction method. Conclusions: A novel approach has been proposed to retrieve an x-ray phase shift image induced by an object from intensity images measured at different distances in the Fresnel diffraction region. The authors' approach has the second-order accuracy and is able to retrieve the phase shift of an object stably, overcoming the restriction of slow phase variation assumed by the conventional phase retrieval techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Rare Earth Elements (Er, Ho) on Semi-Metallic Materials (ScN) in an Applied Electric Field

The development of materials and fabrication technology for field-controlled spectrally active optics is essential for applications such as membrane optics, filters for LIDARs, windows for sensors, telescopes, spectroscopes, cameras and flat-panel displays. The dopants of rare earth elements, in a host of optical systems, create a number of absorption and emission band structures and can easily be incorporated into many high quality crystalline and amorphous hosts. In wide band-gap semiconductors like ScN, the existing deep levels can capture or emit the mobile charges, and can be ionized with the loss or capture of the carriers which are the fundamental basis of concept for smart optic materials. The band gap shrinkage or splitting with dopants supports the possibility of this concept. In the present work, a semi-metallic material (ScN) was doped with rare earth elements (Er, Ho) and tested under an applied electric field to characterize spectral and refractive index shifts by either Stark or Zeeman Effect. These effects can be verified using the UV-Vis spectroscopy, the Hall Effect measurement and the ellipsometric spectroscopy. The optical band gaps of ScN doped with Er and doped with Ho were experimentally estimated as 2.33eV and 2.24eV ( 0.2eV) respectively. This is less than that of undoped ScN (2.5 0.2eV). The red-shifted absorption onset is a direct evidence for the decrease of band gap energy (Eg), and the broadening of valence band states is attributable to the doping cases. A decrease in refractive index with an applied field was observed as a small shift in absorption coefficient using a variable angle spectroscopic ellipsometer. In the presence of an electric field, mobile carriers are redistributed within the space charge region (SCR) to produce this electro-refractive effect. The shift in refractive index is also affected by the density and location of deep potential wells within the SCR. In addition, the microstructure change was observed by a TEM analysis. These results give an insight for future applications for the field-controlled spectrally active material systems.

Kim, Hyunjung↗

Enhanced axial confinement in a monolithically integrated self-rolled-up SiN x vertical microring photonic coupler

We report an efficient method to introduce enhanced axial confinement in the self-rolled-up SiN x vertical microtube coupler by depositing a thin layer of high refractive index material strip within the coupling section and effectively forming a vertical microring. Three times wider mode spacing is observed in such a vertical microring coupler monolithically integrated with a silicon nitride ridge waveguide as compared to the one without such axial confinement. More importantly, single mode operation within the telecomm C-band and S-band is achieved. The self-rolled-up microtube has been demonstrated to be a versatile device platform, which has found application in a number of areas including nanophotonics,1–7 microelectronics,8 chemical and biological sensing,9–11 and intelligent synthetic neural circuits.12 Because the microtube is a three dimensional (3D) structure readily fabricated using two dimensional processing technology, it may serve naturally as a component in 3D-integrated devices. We had previously demonstrated a vertical microtube coupler (VμTC) monolithically integrated with planar ridge waveguides in silicon photonic platform to achieve 3D photonic coupling and observed greatly enhanced coupling between the microtube and the underlying ridge waveguide.1,13 A similar result was reported independently by another research group shortly thereafter.2 One limitation of the VμTC used in previous experiments is that it supports many modes within the telecommunication C-band because of poor axial confinement. For example, we found multiple resonant coupling peaks, which is not desirable for wavelength division multiplexing (WDM) switches. In order to increase the mode spacing of this 3D photonic coupler and to achieve single mode operation within the C-band, we propose efficient axial confinement in the microtube to suppress the higher order modes. Axial confinement in self-rolled-up microtubes had been studied both theoretically and experimentally by a couple of research groups.14–17 In all these previous cases, the axial confinement was introduced by a specially designed geometrical shape of a section of the microtube. After being rolled up, the microtube wall will have different thicknesses at different axial locations. The different wall thicknesses result in a slightly varying effective refractive index of the supported whispering gallery modes (WGMs) along the axial direction of the microtube. When a parabolic shape is used, the effective index of the WGM at the center of the parabola will be the highest and decrease adiabatically along both sides. However, the refractive index change due to different wall thicknesses is very small; hence, the axial confinement is rather weak. Here in this paper, we present our experimental endeavor to incorporate a different axial confinement scheme in the monolithically integrated vertical microtube (VμT) to form a vertical microring (VμR) resonator and demonstrate 3 times wider mode spacing than the microtube based vertical photonic coupler and the potential to achieve a higher Q-factor.

36 MATERIALS SCIENCE↗