Improved probe for rectal-cancer detection
Modified protosigmoidoscope, with third partially mirrored lens, provides lateral as well as forward vision for thorough examination of patients for malignant or premalignant lesions of colon and rectum.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Modified protosigmoidoscope, with third partially mirrored lens, provides lateral as well as forward vision for thorough examination of patients for malignant or premalignant lesions of colon and rectum.
Articulated instrument moves by air actuated bladder, while defining position by ultrasonic or RF signals. Device allows optical inspection of large bowel from cecum to rectum with minimal discomfort or risk to patient.
A robust analytical formulation is developed to apply classical initial orbital determination to artificial satellites whose locations are uncertain to about 1 cu km and separated in time by no more than 30 min. An analytical simplification reduces Gauss's method, iteration on the semilatus rectum, iteration on the true anomaly, and the Lambert-Euler technique, to the solution of a single equation in one unknown, instead of the usual coupled triplet of three equations in three unknowns. The method is demonstrated for all common artificial satellite orbits over a variety of time intervals between the two location vectors, and for a varied set of position and distance errors.
The problem of minimum fuel transfer in a central gravity field for power-limited low thrust propulsion has been studied by several investigators. Orbital averaging was used by Edelbaum in the co-axial and co-planar cases, and by Marec and Vinh for the general transfer between elliptical orbits. The co-latus rectum transfer, which has a complete analytical solution, can be applied to the Pole Squatter. Typical results for the evolution of the orbit parameters and the variation of the thrust acceleration along the orbit are shown.
The case of two-impulse transfer between coplanar circular orbits is considered. The global optimality of the Hohmann transfer among the class of two-impulse transfers is proved via ordinary calculus by using the familiar orbital elements, eccentricity e and parameter (semilatus rectum) p. It is noted that this proof is simpler than existing proofs in the literature.
Orbital sensitivity of the gravity field for high degree terms (greater than 30) is analyzed on satellites employed in a Goddard Mars Model GMM-1, complete in spherical harmonics through degree and order 50. The model is obtained from S-band Doppler data on Mariner 9 (M9), Viking Orbiter 1 (VO1), and Viking Orbiter 2 (VO2) spacecraft, which were tracked by the NASA Deep Space Network on seven different highly eccentric orbits. The main sensitivity of the high degree terms is obtained from the VO1 and VO2 low orbits (300 km periapsis altitude), where significant spectral sensitivity is seen for all degrees out through degree 50. The velocity perturbations show a dominant effect at periapsis and significant effects out beyond the semi-latus rectum covering over 180 degrees of the orbital groundtrack for the low altitude orbits. Because of the wideband of periapsis motion covering nearly 180 degrees in w and +39 degrees in latitude coverage, the VO1 300 km periapsis altitude orbit with inclination of 39 degrees gave the dominant sensitivity in the GMM-1 solution for the high degree terms. Although the VO2 low periapsis orbit has a smaller band of periapsis mapping coverage, it strongly complements the VO1 orbit sensitivity for the GMM-1 solution with Doppler tracking coverage over a different inclination of 80 degrees.
For one-way transfers between Earth and Venus, charts are obtained that show velocity, time, and angle parameters as functions of the eccentricity and semilatus rectum of the Sun-focused vehicle conic. From these curves, others are obtained that are useful in planning one-way and round-trip missions to Venus. The analysis is characterized by circular coplanar planetary orbits, successive two-body approximations, impulsive velocity changes, and circular parking orbits at 1.1 planet radii. For round trips the mission time considered ranges from 65 to 788 days, while wait time spent in the parking orbit at Venus ranges from 0 to 467 days. Individual velocity increments, one-way travel times, and departure dates are presented for round trips requiring the minimum total velocity increment. For both single-pass and orbiting Venusian probes, the time span available for launch becomes appreciable with only a small increase in velocity-increment capability above the minimum requirement. Velocity-increment increases are much more effective in reducing travel time for single-pass probes than they are for orbiting probes. Round trips composed of a direct route along an ellipse tangent to Earth's orbit and an aphelion route result in the minimum total velocity increment for wait times less than 100 days and mission times ranging from 145 to 612 days. Minimum-total-velocity-increment trips may be taken along perihelion-perihelion routes for wait times ranging from 300 to 467 days. These wait times occur during missions lasting from 640 to 759 days.
Near-Earth Asteroids (NEAs) have been identified by the current administration as potential destinations for human explorers during the mid-2020s. While the close proximity of these objects' orbits to Earth's orbit creates a risk of highly damaging or catastrophic impacts, it also makes some of these objects particularly accessible to spacecraft departing Earth, and this presents unique opportunities for solar system science and humanity's first ventures beyond cislunar space. Planning such ambitious missions first requires the selection of potentially accessible targets from the growing population of nearly 7,800 NEAs. To accomplish this, NASA is conducting the Near-Earth Object (NEO) Human Space Flight (HSF) Accessible Targets Study (NHATS). Phase I of the NHATS was executed during September of 2010, and Phase II was completed by early March of 2011. The study is ongoing because previously undetected NEAs are being discovered constantly, which has motivated an effort to automate the analysis algorithms in order to provide continuous monitoring of NEA accessibility. The NHATS analysis process consists of a trajectory filter and a minimum maximum estimated size criterion. The trajectory filter employs the method of embedded trajectory grids to compute all possible ballistic round-trip mission trajectories to every NEA in the Jet Propulsion Laboratory (JPL) Small-Body Database (SBDB) and stores all solutions that satisfy the trajectory filter criteria. An NEA must offer at least one qualifying trajectory solution to pass the trajectory filter. The Phase II NHATS filter criteria were purposely chosen to be highly inclusive, requiring Earth departure date between January 1st, 2015 and December 31st, 2040, total round-trip flight time <= 450 days, stay time at the NEA >= 8 days, Earth departure C(sub 3) energy <= 60 km(exp 2)/s(exp 2), total mission delta-v <= 12 km/s (including an Earth departure maneuver from a 400 km altitude circular parking orbit), and a maximum atmospheric re-entry speed of 12 km/s. After determining which NEAs offer at least one trajectory solution meeting the criteria, the estimated size constraint is then imposed whereby those NEAs may only be considered NHATS- qualifying NEAs if their maximum estimated size is >= 30 m. This corresponds to an absolute magnitude H <= 26.5 with an assumed albedo p = 0:05. The following is a brief high-level summary of the Phase II study results. Of the 7,665 NEAs in the SBDB as of February 3rd, 2011, 765 NEAs passed the trajectory filter and yielded a total of 79,157,604 trajectory solutions. The trajectory solutions for each NEA are post-processed into Pork Chop Contour (PCC) plots which show total mission delta-v as a function of Earth departure date and total mission duration. Although the PCC plots necessarily compress a very multi-dimensional design space into a two-dimensional plot, they permit rapid assessment of the breadth and quality of an NEA's available Earth departure season and clearly indicate the regions of the trajectory design space which warrant further analysis and optimization. The PCC plot for the NEA with the greatest number of NHATS-qualifying trajectory solutions, 2000 SG-344, is shown. Of the 765 NEAs which passed the Phase II trajectory filter, a total of 590 NEAs also satisfied the further constraint of maximum estimated size >= 30 m. The distributions of osculating heliocentric orbital semi-major axis (a), eccentricity (e), and inclination (i), for those 590 NEAs are shown. Note that the semi-latus rectum used is equal to alpha (1-e(exp 2)). To further our understanding of round-trip trajectory accessibility dynamics, it is instructive to examine the distribution of the NHATS-Qualifying NEAs according to orbit classification. NEAs are grouped into four orbit families: Atiras (aphelion < 0.983 AU), Atens (aphelion > 0.983 AU, alpha < 1.0 AU), Apollos (perihelion < 1.017 AU, alpha > 1.0 AU), and Amors (1.017 < perihelion < 1.3 AU). Of the 765 NEAhich satisfied the NHATS trajectory criteria, none are Atiras, 193 are Atens (31% of known Atens), 456 are Apollos (11% of known Apollos), and 116 are Amors (4% of known Amors). While Apollos comprise 60% of the NEAs which pass the NHATS trajectory filter and Atens comprise only 25%, the percentages according to orbit family are perhaps more relevant. Note that only 11% of known Apollos passed the trajectory filter while 31% of known Atens passed. These simple statistics alone strongly suggest that Aten orbits possess features which tend to enhance their round-trip trajectory accessibility as compared to Apollos or Amors. This is significant because Atens' orbits cause them to spend considerable time in Earth's daytime sky, making them difficult to discover and track using ground-based observing assets. In this paper we will detail the NHATS analysis algorithms, present and analyze all NHATS results to date, and discuss aspects of HSF mission architecture design for future NEA missions.
Purpose: We report on the clinical process, quality assurance, and geometric and dosimetric results of the first clinical implementation of electromagnetic transponder-guided MLC tracking which occurred on 28 November 2013 at the Northern Sydney Cancer Centre. Methods: An electromagnetic transponder-based positioning system (Calypso) was modified to send the target position output to in-house-developed MLC tracking code, which adjusts the leaf positions to optimally align the treatment beam with the real-time target position. Clinical process and quality assurance procedures were developed and performed. The first clinical implementation of electromagnetic transponder-guided MLC tracking was for a prostate cancer patient being treated with dual-arc VMAT (RapidArc). For the first fraction of the first patient treatment of electromagnetic transponder-guided MLC tracking we recorded the in-room time and transponder positions, and performed dose reconstruction to estimate the delivered dose and also the dose received had MLC tracking not been used. Results: The total in-room time was 21 min with 2 min of beam delivery. No additional time was needed for MLC tracking and there were no beam holds. The average prostate position from the initial setup was 1.2 mm, mostly an anterior shift. Dose reconstruction analysis of the delivered dose with MLC tracking showed similar isodose and target dose volume histograms to the planned treatment and a 4.6% increase in the fractional rectal V{sub 60}. Dose reconstruction without motion compensation showed a 30% increase in the fractional rectal V{sub 60} from that planned, even for the small motion. Conclusions: The real-time beam-target correction method, electromagnetic transponder-guided MLC tracking, has been translated to the clinic. This achievement represents a milestone in improving geometric and dosimetric accuracy, and by inference treatment outcomes, in cancer radiotherapy.
Objective: The purpose of the current study was to investigate the diagnostic performance of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the prediction of v-Ki-ras-2 Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation in colorectal cancer (CRC) patients through a systematic review and meta-analysis. Methods: The PubMed and EMBASE database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients. Results: Across 9 studies (804 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.66 (95% CI 0.60–0.73) without heterogeneity (I{sup 2} = 34.1, p = 0.14) and a pooled specificity of 0.67 (95% CI 0.62–0.72) without heterogeneity (I{sup 2} = 1.63, p = 0.42). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 2.0 (95% CI 1.7–2.4) and negative likelihood ratio (LR−) of 0.5 (95% CI 0.41–0.61). The pooled diagnostic odds ratio (DOR) was 4 (95% CI 3–6). Hierarchical summary receiver operating characteristic (ROC) curve indicates that the areas under the curve were 0.69 (95% CI 0.65–0.73). Conclusion: The current meta-analysis showed the low sensitivity and specificity of F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients. The DOR was very low and the likelihood ratio scatter-gram indicated that F-18 FDG PET/CT might not be useful for prediction of KRAS mutation and not for its exclusion. Therefore, cautious application and interpretation should be paid to the F-18 FDG PET/CT for prediction of KRAS mutation in CRC patients.
Purpose: To assess preoperative short-course radiotherapy (SCR) tumor response in locally advanced rectal cancer (LARC) by means of Standardized Index of Shape (SIS) by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM) and diffusion kurtosis imaging (DKI) parameters derived from diffusion-weighted MRI (DW-MRI). Materials and methods: Thirty-four patients with LARC who underwent MRI scans before and after SCR followed by delayed surgery, retrospectively, were enrolled. SIS, ADC, IVIM parameters [tissue diffusion (D{sub t}), pseudo-diffusion (D{sub p}), perfusion fraction (f{sub p})] and DKI parameters [mean diffusivity (MD), mean of diffusional kurtosis (MK)] were calculated for each patient. IVIM parameters were estimated using two methods, namely conventional biexponential fitting (CBFM) and variable projection (VARPRO). After surgery, the pathological TNM and tumor regression grade (TRG) were estimated. For each parameter, percentage changes between before and after SCR were evaluated. Furthermore, an artificial neural network was trained for outcome prediction. Nonparametric sample tests and receiver operating characteristic curve (ROC) analysis were performed. Results: Fifteen patients were classified as responders (TRG ≤ 2) and 19 as not responders (TRG > 3). Seven patients had TRG 1 (pathological complete response, pCR). Mean and standard deviation values of pre-treatment CBFM D{sub p} and mean value of VARPRO D{sub p} pre-treatment showed statistically significant differences to predict pCR. (p value at Mann–Whitney test was 0.05, 0.03 and 0.008, respectively.) Exclusively SIS percentage change showed significant differences between responder and non-responder patients after SCR (p value << 0.001) and to assess pCR after SCR (p value << 0.001). The best results to predict pCR were obtained by VARPRO Fp mean value pre-treatment with area under ROC of 0.84, a sensitivity of 96.4%, a specificity of 71.4%, a positive predictive value (PPV) of 92.9%, a negative predictive value (NPV) of 83.3% and an accuracy of 91.2%. The best results to assess after treatment complete pathological response were obtained by SIS with an area under ROC of 0.89, a sensitivity of 85.7%, a specificity of 92.6%, a PPV of 75.0%, a NPV of 96.1% and an accuracy of 91.2%. Moreover, the best results to differentiate after treatment responders vs. non-responders were obtained by SIS with an area under ROC of 0.94, a sensitivity of 93.3%, a specificity of 84.2%, a PPV of 82.4%, a NPV of 94.1% and an accuracy of 88.2%. Promising initial results were obtained using a decision tree tested with all ADC, IVIM and DKI extracted parameter: we reached high accuracy to assess pathological complete response after SCR in LARC (an accuracy of 85.3% to assess pathological complete response after SCR using VARPRO D{sub p} mean value post-treatment, ADC standard deviation value pre-treatment, MD standard deviation value post-treatment). Conclusion: SIS is a hopeful DCE-MRI angiogenic biomarker to assess preoperative treatment response after SCR with delayed surgery. Furthermore, an important prognostic role was obtained by VARPRO F{sub p} mean value pre-treatment and by a decision tree composed by diffusion parameters derived by DWI and DKI to assess pathological complete response.
Purpose: Our study aimed to evaluate the diagnostic performance of rectal magnetic resonance imaging (MRI) for local restaging in patients with non-metastatic locally advanced rectal cancer (LARC) after neoadjuvant chemoradiotherapy (CRT) using surgical histopathology of total mesorectal excision as the reference standard. Methods: Ninety-five patients with LARC who underwent rectal MRI after CRT between January 2014 and December 2016 were included. Accuracy, sensitivity, specificity, positive, and negative predictive value for local staging regarding T-stage, N-stage, circumferential resection margin, and MRI tumor regression grade (ymriTRG) were calculated, and inter-test agreements were assessed. Results: 22/95 (23.2%) patients had radiological complete response (rCR), whereas 20/95 (21.1%) had pathological complete response (pCR). Among the patients with pCR, 11/20 (55%) had rCR. Fair agreement was demonstrated between ymriTRG and pathological TRG (ypTRG) (κ = 0.255). The sensitivity and specificity for detection of pCR were 61.1% (95% CI 35.7–82.7) and 89.6% (95% CI 80.6–95.4). For the detection of ypTRG grades 1 and 2, the corresponding values were 67.2% (95% CI 54.3–78.4) and 51.6 (95% CI 33.1–69.8). The accuracy of ymriTRG was 24.2% (95% CI 15.6–32.8). Inter-test agreement in TRG between MRI and pathology was overall fair (κ = 0.255) and slight (κ = 0.179), if TRG 1 + 2. Conclusion: Qualitative assessment on MRI for diagnosing pCR showed moderate sensitivity and high specificity, whereas the diagnosis of TRG had moderate sensitivity and low specificity with slight to fair inter-test agreement when compared with pathological specimens.
Despite advances in surgical techniques and chemoradiation therapy, recurrent rectal cancer remains a cause of morbidity and mortality. After successful treatment of rectal cancer, patients are typically enrolled in a surveillance strategy that includes imaging as studies have shown improved prognosis when recurrent rectal cancer is detected during imaging surveillance versus based on development of symptoms. Additionally, patients who experience a complete clinical response with chemoradiation therapy may elect to enroll in a “watch-and-wait” strategy that includes imaging surveillance rather than surgical resection. Factors that increase the likelihood of recurrence, patterns of recurrence, and the imaging appearances of recurrent rectal cancer are reviewed with a focus on CT, PET CT, and MR imaging.
Purpose: To determine the added value of qualitative and quantitative evaluation of diffusion-weighted magnetic resonance imaging (DWI) in locally advanced rectal cancer (LARC) restaging after neoadjuvant chemo-radiotherapy (CRT). Materials and Methods: A retrospective study was performed of 21 patients with LARC treated with CRT. All patients were evaluated with 1.5 T conventional magnetic resonance imaging (MRI) and DWI (0–1000 s/mm²) before starting therapy and after neoadjuvant CRT. All included patients underwent surgery after CRT: the histopathological evaluation of surgical specimens represented the reference standard for local staging after neoadjuvant therapy. The qualitative analysis was carried out by two operators in consensus, who reviewed the conventional MR image set [T1-weighted and T2-weighted morphological sequences + dynamic contrast-enhanced sequences (DCE)] and the combined set of conventional and DW images. For the quantitative analysis, the apparent diffusion coefficient (ADC) values were measured at each examination. For each lesion, the mean ADC value (ADCpre and ADCpost) and the ΔADC (ADCpost – ADCpre) were calculated, and values of the three groups of response [complete response (pCR), partial response (pPR), stable disease (pSD)] were compared. Results: In LARC restaging, conventional MRI showed a sensitivity of 80% and a specificity of 50%, with a total diagnostic capacity of 71.40%, while by adding DWI sensitivity increased to 100%, specificity to 67%, and total diagnostic capacity to 90.40%. ΔADC correlates with treatment response and a cutoff of 1.35 × 10{sup −3} mm²/s predicts the pCR with a sensitivity of 93.3% and a specificity of 83.3%. Conclusions: Adding DWI to conventional sequences may improve MRI capability to evaluate tumor response to CRT. The quantitative DWI assessment is promising, but larger studies are required.
Rectal adenocarcinoma with mucinous components is an uncommon type of rectal cancer with two distinct histologic subtypes: mucinous adenocarcinoma and signet-ring cell carcinoma. Mucin can also be identified as pattern of response after neoadjuvant treatment. On imaging modalities, mucin typically demonstrates high signal intensity on T2-weighted images, low attenuation on computed tomography, and may be negative on 18-fluorodeoxyglucose positron emission tomography. After neoadjuvant CRT, cellular and acellular mucin share similar imaging features, and differentiating them is currently the main challenge faced by radiologists. Radiologists should be aware of pros, cons, and limitations of each imaging modality in the primary staging and restaging to avoid misinterpretation of the radiological findings.
Anal canal cancer is a rare disease and squamous cell carcinoma is the most common histologic subtype. Traditionally, anal cancer is imaged with CT and PET/CT for purposes of TNM staging. With the increased popularity of MRI for rectal cancer evaluation, MRI has become increasingly utilized for local staging of anal cancer. In this review, we focus on the necessary information radiologists need to know to understand this rare and unique disease and to be familiar with staging of anal cancer on MRI.
In recent years, rectal MRI has become a central diagnostic tool in rectal cancer staging. Indeed, rectal MR has the ability to accurately evaluate a number of important findings that may impact patient management, including distance of the tumor to the mesorectal fascia, presence of extramural vascular invasion (EMVI), presence of lymph nodes, and involvement of the peritoneum/anterior peritoneal reflection. Many of these findings are difficult to assess in nonexpert hands. In this review, we present a practical approach for radiologists to provide high-quality interpretations at initial baseline exams, based on recent guidelines from the Society of Abdominal Radiology, Rectal and Anal Cancer Disease Focused Panel. Practical pearls and pitfalls are discussed, focusing on optimization of technique including, patient preparation and protocol recommendations, interpretation, and essentials of reporting.
Introduction: As computational capabilities have advanced, radiologists and their collaborators have looked for novel ways to analyze diagnostic images. This has resulted in the development of radiomics and radiogenomics as new fields in medical imaging. Radiomics and radiogenomics may change the practice of medicine, particularly for patients with colorectal cancer. Radiomics corresponds to the extraction and analysis of numerous quantitative imaging features from conventional imaging modalities in correlation with several endpoints, including the prediction of pathology, genomics, therapeutic response, and clinical outcome. In radiogenomics, qualitative and/or quantitative imaging features are extracted and correlated with genetic profiles of the imaged tissue. Thus far, several studies have evaluated the use of radiomics and radiogenomics in patients with colorectal cancer; however, there are challenges to be overcome before its routine implementation including challenges related to sample size, model design and interpretability, and the lack of robust multicenter validation set. Material and methods: In this article, we will review the concepts of radiomics and radiogenomics and their potential applications in rectal cancer. Conclusion: Radiologists should be aware of the basic concepts, benefits, pitfalls, and limitations of new radiomic and radiogenomics techniques to achieve a balanced interpretation of the results.