Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Calculation of organ doses in x-ray examinations of premature babies

Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a significant radiation detriment. Knowledge of the radiation dose is therefore necessary to justify the exposures. To calculate doses in the entire body and in specific organs, computational models of the human anatomy are needed. Using medical imaging techniques, voxel phantoms have been developed to achieve a representation as close as possible to the anatomical properties. In this study two voxel phantoms, representing prematurely born babies, were created from computed tomography- and magnetic resonance images: Phantom 1 (1910 g) and Phantom 2 (590 g). The two voxel phantoms were used in Monte Carlo calculations (MCNPX) to assess organ doses. The results were compared with the commercially available software package PCXMC in which the available mathematical phantoms can be downsized toward the prematurely born baby. The simple phantom-scaling method used in PCXMC seems to be sufficient to calculate doses for organs within the radiation field. However, one should be careful in specifying the irradiation geometry. Doses in organs that are wholly or partially outside the primary radiation field depend critically on the irradiation conditions and the phantom model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study Regarding Electromagnetic Radiation Exposure Generated By Mobile Phone

Number of mobile phone users reached to 5 billion subscribers in 2010 [ABI Research, 2010]. A large number of studies illustrated the public concern about adverse effects of mobile phone radiation and possible health hazards. Position of mobile phone use in close proximity to the head leads the main radiation between the hand and the head. Many investigations studying the possible effects of mobile phone exposure, founded no measurable effects of short-term mobile phone radiation, and there was no evidence for the ability to perceive mobile phone EMF in the general population. In this study, field radiation measurements were performed on different brand and different models of mobile phones in active mode, using an EMF RF Radiation Field Strength Power Meter 1 MHz-8 GHz. The study was effectuated on both the 2G and 3G generations phones connected to the providers operating in the frequency range 450 MHz-1800 MHz. There were recorded values in outgoing call and SMS mode, incoming call and SMS mode. Results were compared with ICNIRP guidelines for exposure to general public.

61 RADIATION PROTECTION AND DOSIMETRY↗

Production of neutrons from interactions of GCR-like particles

In order to help assess the risk to astronauts due to the long-term exposure to the natural radiation environment in space, an understanding of how the primary radiation field is changed when passing through shielding and tissue materials must be obtained. One important aspect of the change in the primary radiation field after passing through shielding materials is the production of secondary particles from the breakup of the primary. Neutrons are an important component of the secondary particle field due to their relatively high biological weighting factors, and due to their relative abundance, especially behind thick shielding scenarios. Because of the complexity of the problem, the estimation of the risk from exposure to the secondary neutron field must be handled using calculational techniques. However, those calculations will need an extensive set of neutron cross section and thicktarget neutron yield data in order to make an accurate assessment of the risk. In this paper we briefly survey the existing neutron-production data sets that are applicable to the space radiation transport problem, and we point out how neutron production from protons is different than neutron production from heavy ions. We also make comparisons of one the heavy-ion data sets with Boltzmann-Uehling-Uhlenbeck (BUU) calculations.

Non-NASA Center↗

THE COUPLED PHYSICAL STRUCTURE OF GAS AND DUST IN THE IM Lup PROTOPLANETARY DISK

The spatial distribution of gas and solids in protoplanetary disks determines the composition and formation efficiency of planetary systems. A number of disks show starkly different distributions for the gas and small grains compared to millimeter–centimeter-sized dust. We present new Atacama Large Millimeter/Submillimeter Array observations of the dust continuum, CO, {sup 13}CO, and C{sup 18}O in the IM Lup protoplanetary disk, one of the first systems where this dust–gas dichotomy was clearly seen. The {sup 12}CO is detected out to a radius of 970 au, while the millimeter continuum emission is truncated at just 313 au. Based upon these data, we have built a comprehensive physical and chemical model for the disk structure, which takes into account the complex, coupled nature of the gas and dust and the interplay between the local and external environment. We constrain the distributions of gas and dust, the gas temperatures, the CO abundances, the CO optical depths, and the incident external radiation field. We find that the reduction/removal of dust from the outer disk exposes this region to higher stellar and external radiation and decreases the rate of freeze-out, allowing CO to remain in the gas out to large radial distances. We estimate a gas-phase CO abundance of 5% of the interstellar medium value and a low external radiation field ( G {sub 0} ≲ 4). The latter is consistent with that expected from the local stellar population. We additionally find tentative evidence for ring-like continuum substructure, suggestions of isotope-selective photodissociation, and a diffuse gas halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Physical Conditions of Eta Car Complex Environment Revealed From Photoionization Modeling

The very massive star, Eta Carinae, is enshrouded in an unusual complex environment of nebulosities and structures. The circumstellar gas gives rise to distinct absorption and emission components at different velocities and distances from the central source(s). Through photoionization modeling, we find that the radiation field from the more massive B-star companion supports the low ionization structure throughout the 5.54 year period. The radiation field of an evolved O-star is required to produce the higher ionization . emission seen across the broad maximum. Our studies utilize the HST/STIS data and model calculations of various regimes from doubly ionized species (T= 10,000K) to the low temperature (T = 760 K) conditions conductive to molecule formation (CH and OH). Overall analysis suggests the high depletion in C and O and the enrichment in He and N. The sharp molecular and ionic absorptions in this extensively CNO - processed material offers a unique environment for studying the chemistry, dust formation processes, and nucleosynthesis in the ejected layers of a highly evolved massive star.

Verner, E. M.↗

Triggering the Formation of Direct Collapse Black Holes by Their Congeners

Direct collapse black holes (DCBHs) are excellent candidates for seeds of supermassive black holes observed at z ≳ 6. The formation of a DCBH requires a strong external radiation field to suppress H{sub 2} formation and cooling in a collapsing gas cloud. Such a strong field is not easily achieved by first stars or normal star-forming galaxies. Here we investigate a scenario in which a previously formed DCBH can provide the necessary radiation field for the formation of additional ones. Using a one-zone model and simulated DCBH Spectral Energy Distributions (SEDs) filtered through absorbing gas initially having column density N {sub H}, we derive the critical field intensity, J{sub LW}{sup crit}, to suppress H{sub 2} formation and cooling. For the SED model with N{sub H}=1.3×10{sup 25} cm{sup −2}, 8.0 × 10{sup 24} cm{sup −2}, and 5.0 × 10{sup 24} cm{sup −2}, we obtain J{sub LW}{sup crit}≈22, 35, and 54, all much smaller than the critical field intensity for normal star-forming galaxies J{sub LW}{sup crit}≳1000 X-ray photons from previously formed DCBHs build up a high-z X-ray background (XRB) that may boost the J{sub LW}{sup crit}. However, we find that in the three SED models, J{sub LW}{sup crit} only increases to ≈80, 170, and 390, even when ρ-dot {sub ∙} reaches the maximum value allowed by the present-day XRB level (0.22, 0.034, 0.006 M {sub ⊙} yr{sup −1} Mpc{sup −3}), which is still much smaller than the galactic value. Although considering the XRB from first galaxies may further increase J{sub LW}{sup crit}, we conclude that our investigation supports a scenario in which DCBHs may be more abundant than predicted by models only including galaxies as external radiation sources.

79 ASTRONOMY AND ASTROPHYSICS↗

The bands method for tabulating NLTE material properties

The use of Non-Local Thermal Equilibrium (NLTE) material properties within radiation-hydrodynamic simulations remains a major challenge. The plasma radiative and EOS properties in NLTE can depend on the detailed local radiation field and electron energy distribution. Fully characterizing each of these quantities may require 10’s to 100’s of parameters, making tabulation effectively impossible and requiring expensive calculations for each set of conditions within the simulation. In this work we present a new method that characterizes the local radiation field with a limited number of parameters. Furthermore, this permits pre-calculation and tabulation of the material properties, allowing codes to perform NLTE radiation-hydrodynamic simulations which would otherwise be computationally prohibitive.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pretreatment Staging Positron Emission Tomography/Computed Tomography in Patients With Inflammatory Breast Cancer Influences Radiation Treatment Field Designs

Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for staging of inflammatory breast cancer (IBC). The purpose of this study was to define how pretreatment PET/CT studies affected postmastectomy radiation treatment (PMRT) planning decisions for IBC. Methods and Materials: We performed a retrospective analysis of 62 patients diagnosed with IBC between 2004 and 2009, who were treated with PMRT in our institution and who had a staging PET/CT within 3 months of diagnosis. Patients received a baseline physical examination, staging mammography, ultrasonographic examination of breast and draining lymphatics, and chest radiography; most patients also had a bone scan (55 patients), liver imaging (52 patients), breast MRI (46 patients), and chest CT (25 patients). We compared how PET/CT findings affected PMRT, assuming that standard PMRT would target the chest wall, level III axilla, supraclavicular fossa, and internal mammary chain (IMC). Any modification of target volumes, field borders, or dose prescriptions was considered a change. Results: PET/CT detected new areas of disease in 27 of the 62 patients (44%). The areas of additional disease included the breast (1 patient), ipsilateral axilla (1 patient), ipsilateral supraclavicular (4 patients), ipsilateral infraclavicular (1 patient), ipsilateral IMC (5 patients), ipsilateral subpectoral (3 patients), mediastinal (8 patients), other distant/contralateral lymph nodes (15 patients), or bone (6 patients). One patient was found to have a non-breast second primary tumor. The findings of the PET/CT led to changes in PMRT in 11 of 62 patients (17.7%). These changes included additional fields in 5 patients, adjustment of fields in 2 patients, and higher doses to the supraclavicular fossa (2 patients) and IMC (5 patients). Conclusions: For patients with newly diagnosed IBC, pretreatment PET/CT provides important information concerning involvement of locoregional lymph nodes, mediastinal lymph nodes, and unsuspected sites of distant metastasis. This information is important in the design of radiotherapy treatment fields and, therefore, we recommend that PET/CT be a component of initial staging for IBC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Toxicity After Definitive Concurrent Chemoradiotherapy for Thoracic Esophageal Carcinoma

Purpose: To evaluate late cardiopulmonary toxicities after concurrent chemoradiotherapy (CCRT) for esophageal carcinomas. Methods and Materials: From February 2002 through April 2005, 74 patients with clinical Stage I-IVB carcinoma of the esophagus were treated with CCRT. Sixty-nine patients with thoracic squamous cell carcinoma were the core of this analysis. Patients received 60 Gy of radiation therapy in 30 fractions over 8 weeks, including a 2-week break, and received 2 cycles of fluorouracil/cisplatin chemotherapy concomitantly. Initial radiation fields included primary tumors, metastatic lymph nodes, and supraclavicular, mediastinal, and celiac nodes areas. Late toxicities were assessed with the late radiation morbidity scoring scheme of the Radiation Therapy Oncology Group/European Organiation for Research and Treatment of Cancer. Results: The median age was 67 years (range, 45-83 years). The median follow-up time was 26.1 months for all patients and 51.4 months for patients still alive at the time of analysis. Five cardiopulmonary toxic events of Grade 3 or greater were observed in 4 patients, Grade 5 heart failure and Grade 3 pericarditis in 1 patient, and Grade 3 myocardial infarction, Grade 3 radiation pneumonitis, and Grade 3 pleural effusion. The 2-year cumulative incidence of late cardiopulmonary toxicities of Grade 3 or greater for patients 75 years or older was 29% compared with 3% for younger patients (p = 0.005). Conclusion: The CCRT used in this study with an extensive radiation field is acceptable for younger patients but is not tolerated by patients older than 75 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Got plenty of nothing: cosmic voids as a probe of particle dark matter

The search for a particle dark matter signal in terms of radiation produced by dark matter annihilation or decay has to cope with the extreme faintness of the predicted signal and the presence of masking astrophysical backgrounds. It has been shown that using the correlated information between the dark matter distribution in the Universe with the fluctuations of the cosmic radiation fields has the potential to allow setting apart a pure dark matter signal from astrophysical emissions, since spatial fluctuations in the radiation field due to astrophysical sources and dark matter emission have different features. The cross-correlation technique has been proposed and adopted for dark matter studies by looking at dark matter halos (overdensities). Here in this paper we extend the technique by focusing on the information on dark matter distribution offered by cosmic voids, and by looking specifically at the gamma-ray dark matter emission: we show that, while being underdense and therefore producing a reduced emission as compared to halos, nevertheless in voids the relative size of the cross-correlation signal due to decaying dark matter vs. astrophysical sources is significantly more favourable, producing signal-to-background ratios S/B (even significantly) larger than 1 for decay lifetimes up to 2 × 10 30 s. This is at variance with the case of halos, where S/B is typically (even much) smaller than 1. We show that forthcoming galaxy surveys such as Euclid combined with future generation gamma-ray detectors with improved specifications have the ability to provide a hint of such a signal with a predicted significance up to 5.7σ for galaxies and 1.6σ for the cosmic shear. The bound on the dark matter lifetime attainable exploiting voids is predicted to improve on current bounds in a mass range for the WIMP of 25 ÷ 900 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonuniform Sampling Of Radiation From Antennas

Far-field patterns reconstructed. Nonuniform-sampling technique uses interpolation algorithm to obtain far-field radiation pattern of antenna at any point u, v based on measurements at few sampling points. Applicable to any components of electric field "E" at measurement locations in spherical coordinate system centered at antenna.

Rahmat-Samii, Y.↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A radiating shock evaluated using Implicit Monte Carlo Diffusion

Implicit Monte Carlo [1] (IMC) has been shown to be very expensive when used to evaluate a radiation field in opaque media. Implicit Monte Carlo Diffusion (IMD) [2], which evaluates a spatial discretized diffusion equation using a Monte Carlo algorithm, can be used to reduce the cost of evaluating the radiation field in opaque media [2]. This work couples IMD to the hydrodynamics equations to evaluate opaque diffusive radiating shocks. The Lowrie semi-analytic diffusive radiating shock benchmark[a] is used to verify our implementation of the coupled system of equations. (authors)

97 MATHEMATICS AND COMPUTING↗

Photochemistry chemical kinetics in the interstellar medium.

Gas phase processes involving interstellar molecules are considered. The primary process is photodissociation in the ambient radiation field. In obscured regions, a combination of Johnson's (1965) and Stecher's (1969) Perseus extinction curves was used to obtain the radiation field as a function of the extinction at 5,500 A. On the basis of laboratory measurements, it is concluded that the molecules of water, ammonia, methane, and formaldehyde have lifetimes less than one hundred years.

Donn, B.↗

Neutron and Proton Radiation Damage and Isothermal Annealing of Irradiated SiC Schottky Power Diodes

NASA is exploring the potential use of nuclear reactors as power sources for future missions. These missions will require semiconductor switches to be placed in close vicinity to the reactor, in the midst of a high neutron and gamma radiation field. Cree SiC Schottky diodes, part number CSD10120A, rated at 10 A and 1200 V, were chosen as the test articles for this radiation-hardness study, since SiC is a wide bandgap semiconductor that has exhibited tolerance for such high radiation environments. As an extension of previous work regarding the degradation of SiC Schottky diodes in the presence of a neutron and gamma radiation field, isothermal annealing experiments were performed on these diodes after they were irradiated in The Ohio State University Research Reactor (OSURR). The experimental results demonstrate that even at an anneal temperature of only 175 C, a noticeable improvement in the electrical performance of the diodes, in the form of decreased series resistance, may be readily observed from I-V curve measurements. Also, since electrical components used for space applications will also be exposed to charged particle radiation from space, such as high energy protons in the Van Allen Radiation Belts surrounding earth, it is important that, in studying the effects of radiation-induced displacement damage, the effects of both neutron and charged particle radiation are considered. Therefore, the data obtained from this study were compared with the data obtained from previous 203 MeV proton irradiations, for which the same diode model was tested. To develop neutron-proton equivalencies which are relevant to the radiation electronics hardening community and the materials science community, comparisons of the degradation of the diodes for proton and neutron irradiation are made in two ways 1) on the basis of displacement damage dose, D{sub d} for protons and neutrons; and 2) on the basis of initially induced vacancies per atom (at a temperature of 0 K)(IIVPA0) for protons and Displacements per Atom (DPA) for neutrons. The equivalencies are especially good when the comparisons are made on the basis of IIVPA0, and DPA.

36 MATERIALS SCIENCE↗

The neutron field and radiation shielding efficiency measurement and the luminosity monitoring using the HF RADMON system of the CMS setup

The HF RADMON system monitors radiation environment in the region of the forward calorimeter of the CMS setup. Measurements of neutron fluxes at energies of 7, 8, and 13 GeV are carried out; estimates of the radiation shielding efficiency are obtained. Modernization of the system for operating under high luminosity conditions is completed and its capabilities to be used as an additional luminometer are confirmed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cloud Structure and Cloud-Radiation Interaction: From Smallest Observable Scales (Less than 10 m) to GCM Grid Scales (More than 100 km)

In this presentation we review the fractal nature of internal cloud structure from cm- to km-scales as captured by in-situ probes during long horizontal penetrations by aircraft. We uncover the non-Poissonian spatial distribution of cloud droplets at submeter scales and confirm scale-invariant behavior for large scales. Based on these structural characteristics, we generate simple fractal cloud models that reproduce statistical scaling properties of real clouds. These stochastic models represent a link between nonlinear science, in general, and cloud-radiation interaction, in particular. Next we run three-dimensional radiative transfer computations on these synthetic fractal clouds and compare the structure of the resulting radiation fields with the known structure of the cloud model and with satellite images of real clouds. The different behaviors observed for small and large-scale variabilities will be discussed in detail. We find that while the large-scale fluctuations of the resulting radiation fields resemble those in the original scale-invariant cloud structure, the radiation at small scales is much smoother than its cloud liquid water counterpart. This violates scale-invariance and produces a scale-break at 0.2-0.5 km that is clearly observed in high-resolution satellite data such as from Landsat. Finally, we show how radiative transfer Green function theory in the photon diffusion limit explains (and predicts) the above phenomena of "radiative smoothing."

Marshak, Alexander↗

Notes on CBETA dump shield (CBETA Tech Note 41)

The dump is in a location that is inaccessible to the overhead crane so that it cannot be shielded by large shielding blocks. In this note, the radiation field produced by a 1 mA, 6 MeV electron beam collected by the dump is investigated and a possible shielding arrangement proposed. The radiation field was calculated using the code MCNP6.

43 PARTICLE ACCELERATORS↗