Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Queries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Single-Filament Imaging Mass Spectrometry Lipidomics in Arthrospira platensis

Elucidating intra-organismal biochemical and lipid organization in photosynthetic biological cell factories of filamentous cyanobacteria, i.e., Arthrospira platensis (Spirulina), is important to track physiological response mechanisms during growth. Little is known about the filaments' biochemical organization and cellular structure and no label-free imaging techniques exist that provide molecular mapping. We applied ultra-high resolution mass spectrometry (7T FT-ICR-MS) matrix-assisted laser desorption ionization (MALDI) imaging to immobilized Spirulina filaments to investigate the localization of lipids across distinct physiological regions. We optimized matrix selection and deposition methods with the goal of facilitating high spatial, and intra-filament, resolution using untargeted multivariate statistical spectral deconvolution across MS pixels. Our results demonstrate an improved two step application with an optimized procedure for intra-organismal lipid profiling to improve analyte sensitivity and achieve higher spatial resolution, whereby we evaluate three conventional matrices 2,5-dihydroxybenzoic acid (DHB), a 9:1 ratio of DHB:superDHB (sDHB), 1,5- diaminonaphthalene (DAN) and a 50:50 mix of DHB:sDHB and compare delineation and pixel-based elucidation of intra-filament lipidomics. We identified a total of 1,626 features that could be putatively assigned a lipid-like formula based on database query and 46 unique features, with associated lipid assignments that were significantly distinct in their intra-filament location. MALDI- imaging MS with untargeted statistical spectral deconvolution was used to visualize intra-filament lipidomics organization in Spirulina filaments. Improvements in matrix deposition, including sequential sublimation and pneumatic spraying, increased signal abundance at high spatial resolution and allowed for identification of distinct lipid composition regions. Here in this work outlines a methodology that may be used for micro-ecological untargeted molecular phenotyping.

09 BIOMASS FUELS↗

Using the CPTAC Assay Portal to identify and implement highly characterized targeted proteomics assays

The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative to other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and post-translational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories.

Environmental Molecular Sciences Laboratory↗

High Resolution Data Analysis: Plans and Prospects [Book Chapter]

Herein, a report on the progress on the high resolution data analysis of the ADMX experimental results is presented. In this paper, tools are developed and tested on a blind injection mimicking a Maxwellian like signal in the frequency domain. This blind injection will be used as a test bed which can be later implemented on all the high resolution data. The high resolution data is stored in the Fermilab server. In this analysis a PostgreSQL query was made to ensure the blind injection is in the middle of the frequency spectrum and 19 such files were found. The time series data is read using a c++ program. An apodization function is applied on the time series data and zero filled to reduce the frequency spacing in order to achieve a better interpolation. A FFTW header is used to compute the Fourier transform of the time series data. A Savitzky–Golay filter is applied on the unnormalized power which then can be used to remove the spectral shape. Each frequency spectrum has a bandwidth of 50 kHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EvoGraph: On-The-Fly Efficient Mining of Evolving Graphs on GPU

With the prevalence of the World Wide Web and social networks, there has been a growing interest in high performance analytics for constantly-evolving dynamic graphs. Modern GPUs provide massive AQ1 amount of parallelism for efficient graph processing, but the challenges remain due to their lack of support for the near real-time streaming nature of dynamic graphs. Specifically, due to the current high volume and velocity of graph data combined with the complexity of user queries, traditional processing methods by first storing the updates and then repeatedly running static graph analytics on a sequence of versions or snapshots are deemed undesirable and computational infeasible on GPU. We present EvoGraph, a highly efficient and scalable GPU- based dynamic graph analytics framework.

dynamic graphs↗

High-performance Computing Applied to Semantic Databases

To-date, the application of high-performance computing resources to Semantic Web data has largely focused on commodity hardware and distributed memory platforms. In this paper we make the case that more specialized hardware can offer superior scaling and close to an order of magnitude improvement in performance. In particular we examine the Cray XMT. Its key characteristics, a large, global shared-memory, and processors with a memory-latency tolerant design, offer an environment conducive to programming for the Semantic Web and have engendered results that far surpass current state of the art. We examine three fundamental pieces requisite for a fully functioning semantic database: dictionary encoding, RDFS inference, and query processing. We show scaling up to 512 processors (the largest configuration we had available), and the ability to process 20 billion triples completely in-memory.

99 GENERAL AND MISCELLANEOUS↗

Aryl azide-sulfonamide hybrids induce cellular apoptosis: synthesis and preliminary screening of their cytotoxicity in human HCT116 and A549 cancer cell lines

Simple, small, drug-like molecules bearing aryl azide and aryl sulfonamide moieties were designed and synthesized. The cytotoxic activity of these compounds was measured on colon cancer HCT116, lung cancer A549, and normal fibroblast cells F180 cell lines. All the synthesized compounds showed a significant cytotoxic activity below 100 µM in both HCT116 and A549 cells. Compounds 10e and 10f exhibited the most potent activity with IC{sub 50} values of 2.20 and 6.27 µM on A549 and HCT116 cells, respectively. Also, compounds 10e and 10f showed significant tumor selectivity on HCT116 and A549 cell lines when compared with the reference cytotoxic agent staurosporine. This indicated the promising safety of these compounds on normal cells. In addition, flow cytometry studies showed that HCT116 cell lines treated with the most active compound 10f were arrested in the G2/M phase of the cell cycle. 10f boosted both early and late apoptosis at HCT116 cells. A hypothetical pharmacophore model was built using 14 reported potent carbonic anhydrase I inhibitors. The pharmacophoric study revealed that the tested sulfonamide derivatives 10e and 10f showed significant fitting on the pharmacophore query with reasonable RMSD values. Molecular docking study showed a chelation reaction with the key Zn atom, in addition to different hydrogen bonding, and van der Waals interactions with several important amino acids inside the CA Ι active site. .

60 APPLIED LIFE SCIENCES↗

Delaunay walk for fast nearest neighbor: accelerating correspondence matching for ICP

Point set registration algorithms such as Iterative Closest Point (ICP) are commonly utilized in time-constrained environments like robotics. Finding the nearest neighbor of a point in a reference 3D point set is a common operation in ICP and frequently consumes at least 90% of the computation time. We introduce a novel approach to performing the distance-based nearest neighbor step based on Delaunay triangulation. This greedy algorithm finds the nearest neighbor of a query point by traversing the edges of the Delaunay triangulation created from a reference 3D point set. Our work integrates the Delaunay traversal into the correspondences search of ICP and exploits the iterative aspect of ICP by caching previous correspondences to expedite each iteration. An algorithmic analysis and comparison is conducted showing an order of magnitude speedup for both serial and vector processor implementation.

3d point cloud processing↗

aphBO-2GP-3B: a budgeted asynchronous parallel multi-acquisition functions for constrained Bayesian optimization on high-performing computing architecture

High-fidelity complex engineering simulations are often predictive, but also computationally expensive and often require substantial computational efforts. The mitigation of computational burden is usually enabled through parallelism in high-performance cluster (HPC) architecture. Optimization problems associated with these applications is a challenging problem due to the high computational cost of the high-fidelity simulations. In this paper, an asynchronous parallel constrained Bayesian optimization method is proposed to efficiently solve the computationally expensive simulation-based optimization problems on the HPC platform, with a budgeted computational resource, where the maximum number of simulations is a constant. The advantage of this method are three-fold. Firstly, the efficiency of the Bayesian optimization is improved, where multiple input locations are evaluated parallel in an asynchronous manner to accelerate the optimization convergence with respect to physical runtime. This efficiency feature is further improved so that when each of the inputs is finished, another input is queried without waiting for the whole batch to complete. Second, the proposed method can handle both known and unknown constraints. Third, the proposed method samples several acquisition functions based on their rewards using a modified GP-Hedge scheme. The proposed framework is termed aphBO-2GP-3B, which means asynchronous parallel hedge Bayesian optimization with two Gaussian processes and three batches. The numerical performance of the proposed framework aphBO-2GP-3B is comprehensively benchmarked using 16 numerical examples, compared against other 6 parallel Bayesian optimization variants and 1 parallel Monte Carlo as a baseline, and demonstrated using two real-world high-fidelity expensive industrial applications. The first engineering application is based on finite element analysis (FEA) and the second one is based on computational fluid dynamics (CFD) simulations.

97 MATHEMATICS AND COMPUTING↗

Quantum Algorithm for Linear Non-unitary Dynamics with Near-Optimal Dependence on All Parameters

We introduce a family of identities that express general linear non-unitary evolution operators as a linear combination of unitary evolution operators, each solving a Hamiltonian simulation problem. This formulation can exponentially enhance the accuracy of the recently introduced linear combination of Hamiltonian simulation (LCHS) method [An, Liu, and Lin, Physical Review Letters, 2023]. For the first time, this approach enables quantum algorithms to solve linear differential equations with both optimal state preparation cost and near-optimal scaling in matrix queries on all parameters.

Applied Dynamical Systems↗

Juxtatumoral perinephric fat analysis in clear cell renal cell carcinoma

Purpose: The purpose of the study was to evaluate the feasibility of using contrast-enhanced computed tomography (CECT)-based texture analysis (CTTA) metrics to differentiate between juxtatumoral perinephric fat (JPF) surrounding low-grade (ISUP 1–2) versus high-grade (ISUP 3–4) clear cell renal cell carcinoma (ccRCC). Methods: In this IRB-approved study, we retrospectively queried the surgical database between June 2009 and April 2016 and identified 83 patients with pathologically confirmed ccRCC (low grade: n = 54, mean age = 61.5 years, 18F/35M; high grade n = 30, mean age = 61.7 years, 8F/22M) who also had pre-operative multiphase CT acquisitions. CT images were transferred to a 3D workstation, and nephrographic phase JPF regions were manually segmented. Using an in-house developed Matlab program, a CTTA panel comprising of texture metrics extracted using six different methods, histogram, 2D- and 3D-Gray-level co-occurrence matrix (GLCM) and Gray-level difference matrix (GLDM), and 2D-Fast Fourier Transform (FFT) analyses, was applied to the segmented images to assess JPF textural heterogeneity in low- versus high-grade ccRCC. Univariate analysis and receiver-operator characteristics (ROC) analysis were used to assess interclass differences in texture metrics and their prediction accuracy, respectively. Results: All methods except GLCM consistently revealed increased heterogeneity in the JPF surrounding high- versus low-grade ccRCC. FFT showed increased complexity index (p < 0.01). Histogram analysis showed increased kurtosis and positive skewness in (p < 0.03), and GLDM analysis showed decreased measure of correlation coefficient (MCC) (p < 0.04). Several of the GLCM metrics showed statistically significant (p < 0.04) textural differences between the two groups, but with no consistent trend. ROC analysis showed that MCC in GLCM analysis had an area under the curve of 0.75. Conclusions: Our study suggests that CTTA of ccRCC shows statistically significant textural differences in JPF surrounding high- versus low-grade ccRCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep learning and radiomics: the utility of Google TensorFlow™ Inception in classifying clear cell renal cell carcinoma and oncocytoma on multiphasic CT

Purpose: Currently, all solid enhancing renal masses without microscopic fat are considered malignant until proven otherwise and there is substantial overlap in the imaging findings of benign and malignant renal masses, particularly between clear cell RCC (ccRCC) and benign oncocytoma (ONC). Radiomics has attracted increased attention for its utility in pre-operative work-up on routine clinical images. Radiomics based approaches have converted medical images into mineable data and identified prognostic imaging signatures that machine learning algorithms can use to construct predictive models by learning the decision boundaries of the underlying data distribution. The TensorFlow™ framework from Google is a state-of-the-art open-source software library that can be used for training deep learning neural networks for performing machine learning tasks. The purpose of this study was to investigate the diagnostic value and feasibility of a deep learning-based renal lesion classifier using open-source Google TensorFlow™ Inception in differentiating ccRCC from ONC on routine four-phase MDCT in patients with pathologically confirmed renal masses. Methods: With institutional review board approval for this 1996 Health Insurance Portability and Accountability Act compliant retrospective study and a waiver of informed consent, we queried our institution’s pathology, clinical, and radiology databases for histologically proven cases of ccRCC and ONC obtained between January 2000 and January 2016 scanned with a an intravenous contrast-enhanced four-phase renal mass protocol (unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases). To extract features to be used for the machine learning model, the entire renal mass was contoured in the axial plane in each of the four phases, resulting in a 3D volume of interest (VOI) representative of the entire renal mass. We investigated thirteen different approaches to convert the acquired VOI data into a set of images that adequately represented each tumor which was used to train the final layer of the neural network model. Training was performed over 4000 iterations. In each iteration, 90% of the data were designated as training data and the remaining 10% served as validation data and a leave-one-out cross-validation scheme was implemented. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive (NPV) values, and CIs were calculated for the classification of the thirteen processing modes. Results: We analyzed 179 consecutive patients with 179 lesions (128 ccRCC and 51 ONC). The ccRCC cohort had a mean size of 3.8 cm (range 0.8–14.6 cm) and the ONC cohort had a mean lesion size of 3.9 cm (range 1.0–13.1 cm). The highest specificity and PPV (52.9% and 80.3%, respectively) were achieved in the EX phase when we analyzed the single mid-slice of the tumor in the axial, coronal and sagittal plane, and when we increased the number of mid-slices of the tumor to three, with an accuracy of 75.4%, which also increased the sensitivity to 88.3% and the PPV to 79.6%. Using the entire tumor volume also showed that classification performance was best in the EX phase with an accuracy of 74.4%, a sensitivity of 85.8% and a PPV of 80.1%. When the entire tumor volume, plus mid-slices from all phases and all planes presented as tiled images, were submitted to the final layer of the neural network we achieved a PPV of 82.5%. Conclusions: The best classification result was obtained in the EX phase among the thirteen classification methods tested. Our proof of concept study is the first step towards understanding the utility of machine learning in the differentiation of ccRCC from ONC on routine CT images. We hope this could lead to future investigation into the development of a multivariate machine learning model which may augment our ability to accurately predict renal lesion histology on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single institutional experience with initial ultrasound followed by computed tomography or magnetic resonance imaging for acute appendicitis in adults

Purpose: The objectives of this study was to assess the performance of ultrasound (US) for suspected appendicitis in adult patients and to evaluated the additive value of short-interval (within 1 week) computed tomography (CT) or Magnetic Resonance Imaging (MRI) after performing an initial US. Methods: In this IRB-approved, HIPAA-compliant, retrospective study, electronic medical records (EMRs) were queried for “US appendicitis” performed over a 2-year interval. EMR was reviewed for CT or MRI performed within 1 week of this exam, and if any new or additional information was available at subsequent exam. White count, patient disposition, and pathology, if surgery was performed, were also recorded. Results: 682 patients underwent US for appendicitis over a 2-year duration, age range from 18 to 92 years (average: 30.1 years, M:F = 141:541). Findings showed 126/682 patients with normal appendix, 75/682 uncomplicated appendicitis, and 4/682 with complicated appendicitis. When performed, no additional findings were seen in these groups on short-interval CT or MRI. 2/682 patients had equivocal findings on US but eventually had normal appendix identified on CT. Four hundred and seventy-three patients had non-visualized appendix, of which only 14/473 (3.1%) eventually had appendicitis. Conclusions: Ultrasound is an effective initial modality for evaluating appendicitis even in adult patients. Once a normal appendix, uncomplicated or complicated appendicitis is identified on US, no further imaging is necessary. Very few patients with non-visualization of the appendix eventually have appendicitis. Hence, these patients can be managed with active clinical follow-up rather than immediate CT or MRI. Symptoms and clinical scoring systems can be used for triage of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-Lumen Chest Port Infection Rates in Patients with Head and Neck Cancer

PurposeThe aim of this study was to investigate dual-lumen chest port infection rates in patients with head and neck cancer (HNC) compared to those with other malignancies (non-HNC).Materials and MethodsAn IRB-approved retrospective study was performed on 1,094 consecutive chest ports placed over a 2-year period. Patients with poor follow-up (n = 53), no oncologic history (n = 13), or single-lumen ports (n = 183) were excluded yielding a study population of 845 patients. The electronic medical records were queried for demographic information, data regarding ports and infections, and imaging review.ResultsHNC patients experienced more infections (42 vs. 30), an increased infection rate per 1,000 catheter days (0.68 vs. 0.21), and more early infections within 30 days compared to non-HNC patients (10 vs. 6) (p < 0.001, p < 0.001, p = 0.02, respectively). An existing tracheostomy at the time of port placement was associated with infection in the HNC group (p = 0.02) but was not an independent risk factor for infection in the study population overall (p = 0.06). There was a significant difference in age, male gender, and right-sided ports between the HNC and non-HNC groups (p < 0.01, p < 0.001, and p = 0.01), although these were not found to be independent risk factors for infection (p = 0.32, p = 0.76, p = 0.16).ConclusionHNC patients are at increased risk for infection of dual-lumen chest ports placed via a jugular approach compared to patients with other malignancies. Tracheostomy is associated with infection in HNC patients but is not an independent risk factor for infection in the oncologic population as a whole.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficiency Improvement in a Busy Radiology Practice: Determination of Musculoskeletal Magnetic Resonance Imaging Protocol Using Deep-Learning Convolutional Neural Networks

The purposes of this study are to evaluate the feasibility of protocol determination with a convolutional neural networks (CNN) classifier based on short-text classification and to evaluate the agreements by comparing protocols determined by CNN with those determined by musculoskeletal radiologists. Following institutional review board approval, the database of a hospital information system (HIS) was queried for lists of MRI examinations, referring department, patient age, and patient gender. These were exported to a local workstation for analyses: 5258 and 1018 consecutive musculoskeletal MRI examinations were used for the training and test datasets, respectively. The subjects for pre-processing were routine or tumor protocols and the contents were word combinations of the referring department, region, contrast media (or not), gender, and age. The CNN Embedded vector classifier was used with Word2Vec Google news vectors. The test set was tested with each classification model and results were output as routine or tumor protocols. The CNN determinations were evaluated using the receiver operating characteristic (ROC) curves. The accuracies were evaluated by a radiologist-confirmed protocol as the reference protocols. The optimal cut-off values for protocol determination between routine protocols and tumor protocols was 0.5067 with a sensitivity of 92.10%, a specificity of 95.76%, and an area under curve (AUC) of 0.977. The overall accuracy was 94.2% for the ConvNet model. All MRI protocols were correct in the pelvic bone, upper arm, wrist, and lower leg MRIs. Deep-learning-based convolutional neural networks were clinically utilized to determine musculoskeletal MRI protocols. CNN-based text learning and applications could be extended to other radiologic tasks besides image interpretations, improving the work performance of the radiologist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DataSpaces: an interaction and coordination framework for coupled simulation workflows

Emerging high-performance distributed computing environments are enabling new end-to-end formulations in science and engineering that involve multiple interacting processes and data-intensive application workflows. For example, current fusion simulation efforts are exploring coupled models and codes that simultaneously simulate separate application processes, such as the core and the edge turbulence. These components run on different high performance computing resources, need to interact at runtime with each other and with services for data monitoring, data analysis and visualization, and data archiving. As a result, they require efficient and scalable support for dynamic and flexible couplings and interactions, which remains a challenge. This paper presents DataSpaces a flexible interaction and coordination substrate that addresses this challenge. DataSpaces essentially implements a semantically specialized virtual shared space abstraction that can be associatively accessed by all components and services in the application workflow. It enables live data to be extracted from running simulation components, indexes this data online, and then allows it to be monitored, queried and accessed by other components and services via the space using semantically meaningful operators. The underlying data transport is asynchronous, low-overhead and largely memory-to-memory. The design, implementation, and experimental evaluation of DataSpaces using a coupled fusion simulation workflow is presented.

Computer Science↗

Neural Active Manifolds: Nonlinear Dimensionality Reduction for Uncertainty Quantification

We present a new approach for nonlinear dimensionality reduction, specifically designed for computationally expensive mathematical models. We leverage autoencoders to discover a one-dimensional neural active manifold (NeurAM) capturing the model output variability, through the aid of a simultaneously learnt surrogate model with inputs on this manifold. Our method only relies on model evaluations and does not require the knowledge of gradients. The proposed dimensionality reduction framework can then be applied to assist outer loop many-query tasks in scientific computing, like sensitivity analysis and multifidelity uncertainty propagation. In particular, we prove, both theoretically under idealized conditions, and numerically in challenging test cases, how NeurAM can be used to obtain multifidelity sampling estimators with reduced variance by sampling the models on the discovered low-dimensional and shared manifold among models. Several numerical examples illustrate the main features of the proposed dimensionality reduction strategy and highlight its advantages with respect to existing approaches in the literature.

Autoencoders↗

National nuclear forensics libraries: a case study on benefits and possibilities for identification of sealed radioactive sources

A National Nuclear Forensic Library (NNFL) is a useful nuclear forensics tool which consists of information and subject matter expertise on radioactive and nuclear (RN) materials produced, used or stored within a State. If RN material is found out of regulatory control the NNFL can be used as part of a nuclear forensics investigation to help identify whether or not the material is consistent with a country’s national holdings. In previous work, a number of signatures which can be useful to identify sealed sources of 241 Am were investigated. To validate the measurement results, an official query concerning information about two of the previously investigated 241 Am sources was sent to the United States Department of State, the international point-of-contact (POC) for the U.S. NNFL. The aim of this work is to show how data obtained in a characterization of a radioactive source can be used in conjunction with an NNFL to investigate the history of a source out of regulatory control.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Results from the fifth galaxy serpent exercise

Galaxy Serpent is an ongoing series of virtual, web-based international tabletop exercises designed to advance the application of National Nuclear Forensics Libraries (NNFLs) in investigations involving nuclear and other radioactive material found out of regulatory control. Here, this iteration emphasized interactions between scientific teams and mock investigative entities. Participants utilized their provided NNFLs to assess material consistency with a provided database of holdings, assign confidence levels, and identify key characteristics relevant to investigative queries. The exercise highlighted both challenges encountered and lessons learned, and advanced best practices for integrating a NNFL into nuclear forensics as part of an investigation.

Database↗