Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Time-delay-and-integration charge coupled devices /CCDs/ applied to the Thematic Mapper

The visible focal plane of the Thematic Mapper, the next generation sensor system for application to earth resource survey, uses complex hybrid assembly techniques to interface silicon photodiodes to JFET preamplifiers. This complexity can be ameliorated by the use of a 20-channel time-delay-and-integration (TDI) CCD with nine stages of integration per channel. By going to a CCD array operating in a TDI mode, over 700 individual op amps can be replaced with only 48 op amps. Smooth spectral response and 70% quantum efficiency have been provided by using doped tin oxide gates over the imaging region.

Thompson, L. L.↗

Design, fabrication, and delivery of a charge injection device as a stellar tracking device

Six 128 x 128 CID imagers fabricated on bulk silicon and with thin polysilicon upper-level electrodes were tested in a star tracking mode. Noise and spectral response were measured as a function of temperature over the range of +25 C to -40 C. Noise at 0 C and below was less than 40 rms carriers/pixel for all devices at an effective noise bandwidth of 150 Hz. Quantum yield for all devices averaged 40% from 0.4 to 1.0 microns with no measurable temperature dependence. Extrapolating from these performance parameters to those of a large (400 x 400) array and accounting for design and processing improvements, indicates that the larger array would show a further improvement in noise performance -- on the order of 25 carriers. A preliminary evaluation of the projected performance of the 400 x 400 array and a representative set of star sensor requirements indicates that the CID has excellent potential as a stellar tracking device.

Burke, H. K.↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

[MODIS Investigation]

Our first activity is based on delivery of code to Bob Evans (University of Miami) for integration and eventual delivery to the MODIS Science Data Support Team. As we noted in our previous semi-annual report, coding required the development and analysis of an end-to-end model of fluorescence line height (FLH) errors and sensitivity. This model is described in a paper in press in Remote Sensing of the Environment. Once the code was delivered to Miami, we continue to use this error analysis to evaluate proposed changes in MODIS sensor specifications and performance. Simply evaluating such changes on a band by band basis may obscure the true impacts of changes in sensor performance that are manifested in the complete algorithm. This is especially true with FLH that is sensitive to band placement and width. The error model will be used by Howard Gordon (Miami) to evaluate the effects of absorbing aerosols on the FLH algorithm performance. Presently, FLH relies only on simple corrections for atmospheric effects (viewing geometry, Rayleigh scattering) without correcting for aerosols. Our analysis suggests that aerosols should have a small impact relative to changes in the quantum yield of fluorescence in phytoplankton. However, the effect of absorbing aerosol is a new process and will be evaluated by Gordon.

Abbott, Mark R.↗

HyTES: Thermal Imaging Spectrometer Development

The Jet Propulsion Laboratory has developed the Hyperspectral Thermal Emission Spectrometer (HyTES). It is an airborne pushbroom imaging spectrometer based on the Dyson optical configuration. First low altitude test flights are scheduled for later this year. HyTES uses a compact 7.5-12 micrometer m hyperspectral grating spectrometer in combination with a Quantum Well Infrared Photodetector (QWIP) and grating based spectrometer. The Dyson design allows for a very compact and optically fast system (F/1.6). Cooling requirements are minimized due to the single monolithic prism-like grating design. The configuration has the potential to be the optimal science-grade imaging spectroscopy solution for high altitude, lighter-than-air (HAA, LTA) vehicles and unmanned aerial vehicles (UAV) due to its small form factor and relatively low power requirements. The QWIP sensor allows for optimum spatial and spectral uniformity and provides adequate responsivity which allows for near 100mK noise equivalent temperature difference (NEDT) operation across the LWIR passband. The QWIP's repeatability and uniformity will be helpful for data integrity since currently an onboard calibrator is not planned. A calibration will be done before and after eight hour flights to gage any inconsistencies. This has been demonstrated with lab testing. Further test results show adequate NEDT, linearity as well as applicable earth science emissivity target results (Silicates, water) measured in direct sunlight.

remote sensing↗

New and Better Near-Infrared Detectors for JWST Near Infrared Spectrograph

ESA and NASA recently selected two 5 m cutoff Teledyne H2RG sensor chip assemblies (SCA) for flight on the James Webb Space Telescope (JWST) Near Infrared Spectrograph (NIRSpec). These HgCdTe SCAs incorporate Teledynes improved barrier layer design that eliminates the degradation that affected earlier JWST H2RGs(Rauscher et al. 2012a). The better indium barrier, together with other design changes, has improved the performance and reliability of JWSTs SCAs. In this article, we describe the measured performance characteristics that most directly affect scientific observations including read noise, total noise, dark current, quantum efficiency (QE), and image persistence. As part of measuring QE, we measured the quantum yield as a function of photon energy,, and found that it exceeds unity for photon energies E (2.65.2) Eg, where Eg is the HgCdTe bandgap energy. This corresponds to. 2 m for NIRSpecs 5 m cutoff HgCdTe. Our measurements agree well with a previous measurement by McCullough et al. (2008) for. 1.3. For 1.3, we find a slower increase in with photon energy than McCullough et al. did. However, and as McCullough et al. note, their two state model of the yield process is not valid for large 1.

New and Better↗

Recent Trends and Innovation in Additive Manufacturing of Soft Functional Materials

The growing demand for wearable devices, soft robotics, and tissue engineering in recent years has led to an increased effort in the field of soft materials. With the advent of personalized devices, the one-shape-fits-all manufacturing methods may soon no longer be the standard for the rapidly increasing market of soft devices. Recent findings have pushed technology and materials in the area of additive manufacturing (AM) as an alternative fabrication method for soft functional devices, taking geometrical designs and functionality to greater heights. For this reason, this review aims to highlights recent development and advances in AM processable soft materials with self-healing, shape memory, electronic, chromic or any combination of these functional properties. Furthermore, the influence of AM on the mechanical and physical properties on the functionality of these materials is expanded upon. Additionally, advances in soft devices in the fields of soft robotics, biomaterials, sensors, energy harvesters, and optoelectronics are discussed. Lastly, current challenges in AM for soft functional materials and future trends are discussed.

36 MATERIALS SCIENCE↗

A review of radiation-induced damage to quantum dots

Quantum dots (QDs) are versatile nano structures that have applications in many fields of research and production, including biosensor technology, computing, photovoltaics, and optoelectronics. QDs have gained interest in the field of radiation detection because of their relative ease of production, tunable photoluminescence, and sensitivity to ionizing radiation. The photoluminescent properties of QDs diminish proportionally to prolonged ionizing radiation interactions, leading many groups to seek out these materials as potential candidates for the next generation of inexpensive, easily manufactured dosimetry and sensors. To use QDs in these applications, the mechanisms of radiation damage to the nanomaterial must be clearly understood and characterized. Herein, we review the study of ionizing radiation damage to QDs. First, the synthesis and properties of QDs are briefly discussed. Next, the radiation damage to QDs due to heavy charged particles, fast electrons, high energy photons, and neutrons are detailed. After this, experimental methods and modelling of QDs in radiation environments are examined. Lastly, future research directions are provided. The goal of this review is to aid in understanding the ionizing radiation effects on QD-based devices.

Snow, Jesse [University of Utah, Salt Lake City, U↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Development of quantum dot materials for infrared cameras (Final CRADA Report)

The aim of this project was to develop scalable methods to produce infrared (IR) mercury telluride (HgTe) colloidal quantum dot (CQD) thin films and demonstrate their utility in a proof-of-concept monolithic SWIR focal plane array (FPA). These objectives were accomplished by scaling up the HgTe CQD synthesis, characterizing physical and electrical properties of HgTe CQDs, evaluating solution-processed coating methods for quality and efficiency, and developing a process flow to integrate HgTe CQDs with commercial-off-the-shelf silicon CMOS readout circuits by solution-processed coating to produce monolithic FPAs. The FPA is the image sensor in an infrared imaging system responsible for detecting and processing reflected or emitted light into an infrared image of the scene under observation. The quality of the image is determined by the sensitivity and resolution of the image sensor in the system. Higher resolution IR FPAs enable higher throughput in manufacturing quality assurance, wider field of view for autonomous navigation, and longer range surveillance for defense.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. Here, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the High Luminosity-LHC. Signal generated by either betas from a 90 Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of Superfluid Helium in Low-Gravity

This report summarizes the work performed under a contract entitled 'Dynamics of Superfluid Helium in Low Gravity'. This project performed verification tests, over a wide range of accelerations of two Computational Fluid Dynamics (CFD) codes of which one incorporates the two-fluid model of superfluid helium (SFHe). Helium was first liquefied in 1908 and not until the 1930s were the properties of helium below 2.2 K observed sufficiently to realize that it did not obey the ordinary physical laws of physics as applied to ordinary liquids. The term superfluidity became associated with these unique observations. The low temperature of SFHe and it's temperature unifonrmity have made it a significant cryogenic coolant for use in space applications in astronomical observations with infrared sensors and in low temperature physics. Superfluid helium has been used in instruments such as the Shuttle Infrared Astronomy Telescope (IRT), the Infrared Astronomy Satellite (IRAS), the Cosmic Background Observatory (COBE), and the Infrared Satellite Observatory (ISO). It is also used in the Space Infrared Telescope (SIRTF), Relativity Mission Satellite formally called Gravity Probe-B (GP-B), and the Test of the Equivalence Principle (STEP) presently under development. For GP-B and STEP, the use of SFHE is used to cool Superconducting Quantum Interference Detectors (SQUIDS) among other parts of the instruments. The Superfluid Helium On-Orbit Transfer (SHOOT) experiment flown in the Shuttle studied the behavior of SFHE. This experiment attempted to get low-gravity slosh data, however, the main emphasis was to study the low-gravity transfer of SFHE from tank to tank. These instruments carried tanks of SFHE of a few hundred liters to 2500 liters. The capability of modeling the behavior of SFHE is important to spacecraft control engineers who must design systems that can overcome disturbances created by the movement of the fluid. In addition instruments such as GP-B and STEP are very sensitive to quasi-steady changes in the mass distribution of the liquid. The CFD codes were used to model the fluid's dynamic motion. Tests in one-g were performed with the main emphasis on being able to compute the actual damping of the fluid. A series of flights on the NASA Lewis reduced gravity DC-9 aircraft were performed with the Jet Propulsion Laboratory (JPL) Low Temperature Flight Facility and a superfluid Test Cell. The data at approximately 0.04g, lg and 2g were used to determine if correct fundamental frequencies can be predicted based on the acceleration field. Tests in zero gravity were performed to evaluate zero gravity motion.

Frank, David J.↗

Low-Noise Wide Bandwith, Hot Electron Bolometer Mixers for Submillimeter Wavelengths

Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.

Bolometer Mixers↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Integrated Electron-tunneling Refrigerator and TES Bolometer for Millimeter Wave Astronomy

We describe progress in the development of a close-packed array of bolometers intended for use in photometric applications at millimeter wavelengths from ground- based telescopes. Each bolometer in the may uses a proximity-effect Transition Edge Sensor (TES) sensing element and each will have integrated Normal-Insulator-Superconductor (NIS) refrigerators to cool the bolometer below the ambient bath temperature. The NIS refrigerators and acoustic-phonon-mode-isolated bolometers are fabricated on silicon. The radiation-absorbing element is mechanically suspended by four legs, whose dimensions are used to control and optimize the thermal conductance of the bolometer. Using the technology developed at NIST, we fabricate NIS refrigerators at the base of each of the suspension legs. The NIS refrigerators remove hot electrons by quantum-mechanical tunneling and are expected to cool the biased (approx.10 pW) bolometers to <170 mK while the bolometers are inside a pumped 3He-cooled cryostat operating at approx.280 mK. This significantly lower temperature at the bolometer allows the detectors to approach background-limited performance despite the simple cryogenic system.

Silverberg, R. F.↗

System and method for measuring fluid properties using magnetic field techniques via magnetic tracer

A method and apparatus for determining a property of a fluid in a vessel. The method uses magnetic tracer particles and an externally applied magnetic field which orients the particles. When the fluid moves, it changes the orientation of the tracer particles, thus changing the magnetic fields. These changes are detected by external magnetic field sensors. By using mathematical models, the property of the fluid in the vessel is determined from the detected magnetic field. In this manner, fluid vorticity, velocity, strain and stress may be estimated.

42 ENGINEERING↗

Corals from Space

The goal of this research is to monitor the health and vigor of coral reef ecosystems, and their sensitivity to natural and anthropogenic climate changes. To achieve these lofty goals, this research is investigating the feasibility of using spaceborne high-resolution spectrometers (on the US Landsat, French Systeme Probatoire pour l'Observation de la Terre [SPOT] and/or the Indian Resources Satellite [IRS 1C & 1D] spacecraft) to first map the aerial extent of coral reef systems, and second separate the amount of particular corals. If this is successful, we could potentially provide a quantum leap in our understanding of coral reef systems, as well as provide much needed baseline data to measure future changes in global coral reef ecosystems. In collaboration with Tomas Tomascik, Yann Morel, and other colleagues, a series of experiments were planned to coordinate in situ coral observations, high-resolution spaceborne imagery (from Landsat, SPOT, and, possibly, IRS IC spacecraft), and NASA Space Shuttle photographs and digital images. Our eventual goal is to develop "coral health algorithms" that can be used to assess time series of imagery collected from satellite sensors (Landsat since 1972, SPOT since 1986) in concert with in situ observations. The bad news from last year was that from 1997 to mid- 1998, the extreme cloudiness over southeast Asia due to prolonged smoke from El Nino-related fires and the economic chaos in this region frustrated both our space and reef-based data collection activities. When this volatile situation stabilizes, we will restart these activities. The good news was that in collaboration with Al Strong at the National Oceanic and Atmospheric Administration (NOAA) we had an exciting year operationally using the NOAA's Advanced Very High Resolution Radiometer sensor derived sea surface temperature products to warn of coral "bleaching" at many locations throughout the tropics. Data from NOAA's satellites showed that during the El Nino of 1997 and the first half of 1998, more ocean area in the tropics experienced exceptionally high sea surface temperatures, or "hot spots," than have been observed in any fall year since the El Nino of 1982. From January to July, the coral bleaching events were concentrated in the Southern Hemisphere (during its warm season). Since July 1998, the reports of extensive coral bleaching have again spread into regions of the Northern Hemisphere following abnormally high sea surface temperatures, especially around the Philippines and throughout the Caribbean Basin, Bahamas, Bermuda and Florida Keys. These El Nino induced events clearly demonstrated that corals are the "canaries of the marine ecosystem," highly sensitive to short-term natural climate events (El Nino), and should be monitored as measures of longer-term environmental and climate change. Additional information is contained in the original.

Patzert, William C.↗