Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Thermodynamic modeling with uncertainty quantification using the modified quasichemical model in quadruplet approximation: Implementation into PyCalphad and ESPEI

The modified quasichemical model in the quadruplet approximation (MQMQA) considers the first- and the second-nearest-neighbor coordination and interactions, particularly useful in describing short-range ordering (SRO) in complex liquids such as molten salts, slag in metal processing, and electrolytic solutions. Here, the present work implements the MQMQA into the Python based open-source software PyCalphad for thermodynamic calculations. This endeavor facilitates the development of MQMQA-based thermodynamic database with uncertainty quantification (UQ) and propagation (UP) using the open-source software ESPEI. A new database structure based on Extensible Markup Language (XML) is proposed for ESPEI evaluation of MQMQA model parameters. Using the KF-NiF 2 , KCl-NaCl-MgCl 2 , and CaCl 2 -CaF 2 -LiCl-LiF salt systems as examples, we demonstrate the successful implementation of MQMQA in PyCalphad through thermodynamic calculations of Gibbs energy, equilibrium quadruplet fractions, and phase diagram, as well as database development with UQ and UP using ESPEI. Furthermore, as an application of the present implementation, both the LiF–TbF 3 and LiF-HoF 3 systems have been modeled by MQMQA for the first time, which are in good agreement with experiments. The present implementation hence offers an open-source capability for performing CALPHAD modeling for complex liquids with SRO using MQMQA plus a new XML database structure.

36 MATERIALS SCIENCE↗

Sampling-based Uncertainty Quantification in Deconvolution of X-ray Radiographs

In imaging applications that focus on quantitative analysis{such as X-ray radiography in the security sciences--it is necessary to be able to reliably estimate the uncertainties in the processing algorithms applied to the image data, and deconvolving the system blur out of the image is usually an essential step. In this work we solve the deconvolution problem within a Bayesian framework for edge-enhancing reconstruction with uncertainty quantification. The likelihood is a normal approximation to the Poisson likelihood, and the prior is generated from a classical total variation regularized Poisson deconvolution. Samples from the corresponding posterior distribution are computed using a Markov chain Monte Carlo approach, giving a pointwise measure of uncertainty in the final, deconvolved signal. We demonstrate the results on real data used to calibrate a high-energy X-ray source and show that this approach gives reconstructions as good as classical regularization methods, while mitigating many of their drawbacks.

Deconvolution, Inverse Problems, Markov Chain Mont↗

Quantification of the degree of reaction of fly ash

The quantification of the fly ash (FA) in FA blended cements is an important parameter to understand the effect of the fly ash on the hydration of OPC and on the microstructural development. The FA reaction in two different blended OPC-FA systems was studied using a selective dissolution technique based on EDTA/NaOH, diluted NaOH solution, the portlandite content and by backscattered electron image analysis. The amount of FA determined by selective dissolution using EDTA/NaOH is found to be associated with a significant possible error as different assumptions lead to large differences in the estimate of FA reacted. In addition, at longer hydration times, the reaction of the FA is underestimated by this method due to the presence of non-dissolved hydrates and MgO rich particles. The dissolution of FA in diluted NaOH solution agreed during the first days well with the dissolution as observed by image analysis. At 28 days and longer, the formation of hydrates in the diluted solutions leads to an underestimation. Image analysis appears to give consistent results and to be most reliable technique studied.

36 MATERIALS SCIENCE↗

Uncertainty quantification in multiscale simulation of woven fiber composites

We report woven fiber composites have been increasingly employed as light-weight materials in aerospace, construction, and transportation industries due to their superior properties. These materials possess a hierarchical structure that necessitates the use of multiscale simulations in their modeling. To account for the inherent uncertainty in materials, such simulations must be integrated with statistical uncertainty quantification (UQ) and propagation (UP) methods. However, limited advancement has been made in this regard due to the significant computational costs and complexities in modeling spatially correlated structural variations coupled at different scales. In this work, a non-intrusive approach is proposed for multiscale UQ and UP to address these limitations. We introduce the top-down sampling method that allows to model non-stationary and continuous (but not differentiable) spatial variations of uncertainty sources by creating nested random fields (RFs) where the hyperparameters of an ensemble of RFs is characterized by yet another RF. We employ multi-response Gaussian RFs in top-down sampling and leverage statistical techniques (such as metamodeling and dimensionality reduction) to address the considerable computational costs of multiscale simulations. We apply our approach to quantify the uncertainty in a cured woven composite due to spatial variations of yarn angle, fiber volume fraction, and fiber misalignment angle. Finally, our results indicate that, even in linear analysis, the effect of uncertainty sources on the material’s response could be significant.

42 ENGINEERING↗

Context-aware learning of hierarchies of low-fidelity models for multi-fidelity uncertainty quantification

Multi-fidelity Monte Carlo methods leverage low-fidelity and surrogate models for variance reduction to make tractable uncertainty quantification even when numerically simulating the physical systems of interest with high-fidelity models is computationally expensive. This work proposes a context-aware multi-fidelity Monte Carlo method that optimally balances the costs of training low-fidelity models with the costs of Monte Carlo sampling. It generalizes the previously developed context-aware bi-fidelity Monte Carlo method to hierarchies of multiple models and to more general types of low-fidelity models. When training low-fidelity models, the proposed approach takes into account the context in which the learned low-fidelity models will be used, namely for variance reduction in Monte Carlo estimation, which allows it to find optimal trade-offs between training and sampling to minimize upper bounds of the mean-squared errors of the estimators for given computational budgets. This is in stark contrast to traditional surrogate modeling and model reduction techniques that construct low-fidelity models with the primary goal of approximating well the high-fidelity model outputs and typically ignore the context in which the learned models will be used in upstream tasks. Further, the proposed context-aware multi-fidelity Monte Carlo method applies to hierarchies of a wide range of types of low-fidelity models such as sparse-grid and deep-network models. Numerical experiments with the gyrokinetic simulation code Gene show speedups of up to two orders of magnitude compared to standard estimators when quantifying uncertainties in small-scale fluctuations in confined plasma in fusion reactors. This corresponds to a runtime reduction from 72 days to four hours on one node of the Lonestar6 supercomputer at the Texas Advanced Computing Center.

42 ENGINEERING↗

The need for non- or minimally-invasive biomonitoring strategies and the development of pharmacokinetic/pharmacodynamic models for quantification

Advancements in Exposure Science involving the development and deployment of biomarkers of exposure and biological response are anticipated to significantly (and positively) influence health outcomes associated with occupational, environmental and clinical exposure to chemicals/drugs. To achieve this vision, innovative strategies are needed to develop multiplex sensor platforms capable of quantifying individual and mixed exposures (i.e. systemic dose) by measuring biomarkers of dose and biological response in readily obtainable (non-invasive) biofluids. Secondly, the use of saliva (alternative to blood) for biomonitoring coupled with the ability to rapidly analyze multiple samples in real-time offers an innovative opportunity to revolutionize biomonitoring assessments. In this regard, the timing and number of samples taken for biomonitoring will not be limited as is currently the case. In addition, real-time analysis will facilitate identification of work practices or conditions that are contributing to increased exposures and will make possible a more rapid and successful intervention strategy. The initial development and application of computational models for evaluation of saliva/blood analyte concentration at anticipated exposure levels represents an important opportunity to establish the limits of quantification and robustness of multiplex sensor systems by exploiting a unique computational modeling framework. The use of these pharmacokinetic models will also enable prediction of an exposure dose based on the saliva/blood measurement. This novel strategy will result in a more accurate prediction of exposures and, once validated, can be employed to assess dosimetry to a broad range of chemicals in support of biomonitoring and epidemiology studies.

59 BASIC BIOLOGICAL SCIENCES↗

Evolutionary multi-objective optimization and Pareto-frontal uncertainty quantification of interatomic forcefields for thermal conductivity simulations

Predictive Molecular Dynamics simulations of thermal transport require forcefields that can simultaneously reproduce several structural, thermodynamic and vibrational properties of materials like lattice constants, phonon density of states, and specific heat. This requires a multi-objective optimization approach for forcefield parameterization. Existing methodologies for forcefield parameterization use ad-hoc and empirical weighting schemes to convert this into a single-objective optimization problem. Here, we provide and describe software to perform multi-objective optimization of Stillinger–Weber forcefields (SWFF) for two-dimensional layered materials using the recently developed 3rd generation non-dominated sorting genetic algorithm (NSGA-III). NSGA-III converges to the set of optimal forcefields lying on the Pareto front in the multi-dimensional objective space. This set of forcefields is used for uncertainty quantification of computed thermal conductivity due to variability in the forcefield parameters. We demonstrate this new optimization scheme by constructing a SWFF for a representative two-dimensional material, 2H-MoSe 2 and quantifying the uncertainty in their computed thermal conductivity.

97 MATHEMATICS AND COMPUTING↗

From observation to replication: machine-learning-driven quantification and replication of fine-scale fish kinematics and behavior

Long-term quantification of fish behavior is essential for aquatic ecology, wildlife telemetry, and biomechanical device development. However, the observation duration required to obtain reliable behavioral and kinematic metrics remains unclear, and few tools exist to physically reproduce natural swimming motion for controlled experimentation. We address these challenges by developing a generalizable framework that models behavioral reliability (Spearman–Brown reliability index) as a function of observation duration and derives metric-specific monitoring thresholds. Using juvenile white sturgeon (Acipenser transmontanus) as a case study, we demonstrate that the minimum duration needed for reliable estimates varies substantially across kinematic features: to exceed a reliability of 0.8, total distance traveled requires 12 days, average curvature (mm?¹) 15 days, tail-beat frequency (Hz) 8 days, and average speed (body length/s) 17 days. We further bridge digital analysis and physical testing by developing a hardware-in-the-loop simulator that reconstructs machine-learning-derived swimming kinematics with high fidelity (correlation coefficient 0.98–0.99, RMSE 1.22–1.27 mm over a 5-minute segment). This platform enables realistic, repeatable motion stimuli for evaluating aquatic sensing technologies and bio-integrated devices under controlled conditions. Together, these contributions provide a scalable approach for designing long-term behavioral studies and a data-driven connection between ecological observation and robotic experimentation.

Hwang, SungJoo↗

On data-driven energy flexibility quantification: A framework and case study

Building energy flexibility is an important resource for a sustainable and resilient power grid, and an important measure to reduce utility costs for building owners. Quantifying energy flexibility for existing buildings can provide critical insights in optimizing their operation. Data-driven methods for building energy modeling and analytics are gaining popularity due to the increasingly available sensor and meter infrastructure, affordable computational resources, and advanced modeling algorithms. However, their application in quantifying the energy flexibility of real buildings is still limited due to the heterogeneous data types and limited data availability. Here, this study proposes a framework for building-level data-driven energy flexibility quantification that considers different levels of data availability and use cases. Two case studies with real building data collected at different scales were conducted to demonstrate the proposed framework for different purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Respiration-Averaged Computed Tomography on Positron Emission Tomography/Computed Tomography Quantification and its Potential Impact on Gross Tumor Volume Delineation

Purpose: Patient respiratory motion can cause image artifacts in positron emission tomography (PET) from PET/computed tomography (CT) and change the quantification of PET for thoracic patients. In this study, respiration-averaged CT (ACT) was used to remove the artifacts, and the changes in standardized uptake value (SUV) and gross tumor volume (GTV) were quantified. Methods and Materials: We incorporated the ACT acquisition in a PET/CT session for 216 lung patients, generating two PET/CT data sets for each patient. The first data set (PET{sub HCT}/HCT) contained the clinical PET/CT in which PET was attenuation corrected with a helical CT (HCT). The second data set (PET{sub ACT}/ACT) contained the PET/CT in which PET was corrected with ACT. We quantified the differences between the two datasets in image alignment, maximum SUV (SUV{sub max}), and GTV contours. Results: Of the patients, 68% demonstrated respiratory artifacts in the PET{sub HCT}, and for all patients the artifact was removed or reduced in the corresponding PET{sub ACT}. The impact of respiration artifact was the worst for lesions less than 50 cm{sup 3} and located below the dome of the diaphragm. For lesions in this group, the mean SUV{sub max} difference, GTV volume change, shift in GTV centroid location, and concordance index were 21%, 154%, 2.4 mm, and 0.61, respectively. Conclusion: This study benchmarked the differences between the PET data with and without artifacts. It is important to pay attention to the potential existence of these artifacts during GTV contouring, as such artifacts may increase the uncertainties in the lesion volume and the centroid location.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardized Method for Quantification of Developing Lymphedema in Patients Treated for Breast Cancer

Purpose: To develop a simple and practical formula for quantifying breast cancer-related lymphedema, accounting for both the asymmetry of upper extremities' volumes and their temporal changes. Methods and Materials: We analyzed bilateral perometer measurements of the upper extremity in a series of 677 women who prospectively underwent lymphedema screening during treatment for unilateral breast cancer at Massachusetts General Hospital between August 2005 and November 2008. Four sources of variation were analyzed: between repeated measurements on the same arm at the same session; between both arms at baseline (preoperative) visit; in follow-up measurements; and between patients. Effects of hand dominance, time since diagnosis and surgery, age, weight, and body mass index were also analyzed. Results: The statistical distribution of variation of measurements suggests that the ratio of volume ratios is most appropriate for quantification of both asymmetry and temporal changes. Therefore, we present the formula for relative volume change (RVC): RVC = (A{sub 2}U{sub 1})/(U{sub 2}A{sub 1}) - 1, where A{sub 1}, A{sub 2} are arm volumes on the side of the treated breast at two different time points, and U{sub 1}, U{sub 2} are volumes on the contralateral side. Relative volume change is not significantly associated with hand dominance, age, or time since diagnosis. Baseline weight correlates (p = 0.0074) with higher RVC; however, baseline body mass index or weight changes over time do not. Conclusions: We propose the use of the RVC formula to assess the presence and course of breast cancer-related lymphedema in clinical practice and research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Organ Motion During Chemoradiotherapy of Rectal Cancer Using Cone-Beam Computed Tomography

Purpose: There has been no previously published data related to the quantification of rectal motion using cone-beam computed tomography (CBCT) during standard conformal long-course chemoradiotherapy. The purpose of the present study was to quantify the interfractional changes in rectal movement and dimensions and rectal and bladder volume using CBCT and to quantify the bony anatomy displacements to calculate the margins required to account for systematic ({Sigma}) and random ({sigma}) setup errors. Methods and Materials: CBCT images were acquired from 16 patients on the first 3 days of treatment and weekly thereafter. The rectum and bladder were outlined on all CBCT images. The interfraction movement was measured using fixed bony landmarks as references to define the rectal location (upper, mid, and low), The maximal rectal diameter at the three rectal locations was also measured. The bony anatomy displacements were quantified, allowing the calculation of systematic ({Sigma}) and random ({sigma}) setup errors. Results: A total of 123 CBCT data sets were analyzed. Analysis of variance for standard deviation from planning scans showed that rectal anterior and lateral wall movement differed significantly by rectal location. Anterior and lateral rectal wall movements were larger in the mid and upper rectum compared with the low rectum. The posterior rectal wall movement did not change significantly with the rectal location. The rectal diameter changed more in the mid and upper than in the low rectum. No consistent relationship was found between the rectal and bladder volume and time, nor was a significant relationship found between the rectal volume and bladder volume. Conclusions: In the present study, the anterior and lateral rectal movement and rectal diameter were found to change most in the upper rectum, followed by the mid rectum, with the smallest changes seen in the low rectum. Asymmetric margins are warranted to ensure phase 2 coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification and quantification of multinuclear Cu active sites derived from monomeric Cu moieties for dry NO oxidation over Cu-SSZ-13

The identification and quantification of multinuclear Cu-oxo cations in Cu-zeolites is a challenge amidst the dynamic nature of Cu ions in Cu-zeolites. Herein, we synthesized Cu-SSZ-13 zeolites containing varying densities of monomeric Cu cations (Z 2 Cu and ZCuOH, where Z represents an anionic site on the zeolite framework). The number of Cu-oxo cations, quantified using carbon monoxide temperature programmed reduction (CO-TPR), quadratically increased with increasing ZCuOH density, evidencing that proximal ZCuOH sites are precursors to Cu-oxo dimers. We also find that dehydrated proximal ZCuOH with overlapping diffusion radii of at most 0.5 nm can form Cu-oxo dimers. CO-TPR also revealed the presence of three distinct pools (i.e types) of Cu-oxo dimers; these pools catalyze dry NO oxidation at different turnover rates, with the fastest pool 2 to 30 times faster than the slowest pool. Finally, from reaction kinetics and rate law analysis, we also proposed a cohesive dry NO oxidation mechanism and demonstrated that nitrates detected by in situ FTIR are a spectator species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty quantification for systems of conservation laws

Uncertainty quantification through stochastic spectral methods has been recently applied to several kinds of non-linear stochastic PDEs. In this paper, we introduce a formalism based on kinetic theory to tackle uncertain hyperbolic systems of conservation laws with Polynomial Chaos (PC) methods. The idea is to introduce a new variable, the entropic variable, in bijection with our vector of unknowns, which we develop on the polynomial basis: by performing a Galerkin projection, we obtain a deterministic system of conservation laws. We state several properties of this deterministic system in the case of a general uncertain system of conservation laws. We then apply the method to the case of the inviscid Burgers' equation with random initial conditions and we present some preliminary results for the Euler system. We systematically compare results from our new approach to results from the stochastic Galerkin method. In the vicinity of discontinuities, the new method bounds the oscillations due to Gibbs phenomenon to a certain range through the entropy of the system without the use of any adaptative random space discretizations. It is found to be more precise than the stochastic Galerkin method for smooth cases but above all for discontinuous cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A flexible uncertainty quantification method for linearly coupled multi-physics systems

Highlights: •We propose a “modularly hybrid” UQ methodology suitable for independent development of module-based multi-physics simulation. •Our algorithmic framework allows for each module to have its own UQ method (either intrusive or non-intrusive). •Information from each module is combined systematically to propagate “global uncertainty”. •Our proposed approach can allow for easy swapping of new methods for any modules without the need to address incompatibilities. •We demonstrate the proposed framework on a practical application involving a multi-species reactive transport model. -- Abstract: This paper presents a novel approach to building an integrated uncertainty quantification (UQ) methodology suitable for modern-day component-based approach for multi-physics simulation development. Our “hybrid” UQ methodology supports independent development of the most suitable UQ method, intrusive or non-intrusive, for each physics module by providing an algorithmic framework to couple these “stochastic” modules for propagating “global” uncertainties. We address algorithmic and computational issues associated with the construction of this hybrid framework. We demonstrate the utility of such a framework on a practical application involving a linearly coupled multi-species reactive transport model.

97 MATHEMATICS AND COMPUTING↗

Improved statistical models for limited datasets in uncertainty quantification using stochastic collocation

This paper presents a data-driven framework for performing uncertainty quantification (UQ) by choosing a stochastic model that accurately describes the sources of uncertainty in a system. This model is propagated through an appropriate response surface function that approximates the behavior of this system using stochastic collocation. Given a sample of data describing the uncertainty in the inputs, our goal is to estimate a probability density function (PDF) using the kernel moment matching (KMM) method so that this PDF can be used to accurately reproduce statistics like mean and variance of the response surface function. Instead of constraining the PDF to be optimal for a particular response function, we show that we can use the properties of stochastic collocation to make the estimated PDF optimal for a wide variety of response functions. We contrast this method with other traditional procedures that rely on the Maximum Likelihood approach, like kernel density estimation (KDE) and its adaptive modification (AKDE). We argue that this modified KMM method tries to preserve what is known from the given data and is the better approach when the available data is limited in quantity. We test the performance of these methods for both univariate and multivariate density estimation by sampling random datasets from known PDFs and then measuring the accuracy of the estimated PDFs, using the known PDF as a reference. Comparing the output mean and variance estimated with the empirical moments using the raw data sample as well as the actual moments using the known PDF, we show that the KMM method performs better than KDE and AKDE in predicting these moments with greater accuracy. This improvement in accuracy is also demonstrated for the case of UQ in electrostatic and electrothermomechanical microactuators. We show how our framework results in the accurate computation of statistics in micromechanical systems.

97 MATHEMATICS AND COMPUTING↗

Π4U: A high performance computing framework for Bayesian uncertainty quantification of complex models

We present Π4U,{sup 1} an extensible framework, for non-intrusive Bayesian Uncertainty Quantification and Propagation (UQ+P) of complex and computationally demanding physical models, that can exploit massively parallel computer architectures. The framework incorporates Laplace asymptotic approximations as well as stochastic algorithms, along with distributed numerical differentiation and task-based parallelism for heterogeneous clusters. Sampling is based on the Transitional Markov Chain Monte Carlo (TMCMC) algorithm and its variants. The optimization tasks associated with the asymptotic approximations are treated via the Covariance Matrix Adaptation Evolution Strategy (CMA-ES). A modified subset simulation method is used for posterior reliability measurements of rare events. The framework accommodates scheduling of multiple physical model evaluations based on an adaptive load balancing library and shows excellent scalability. In addition to the software framework, we also provide guidelines as to the applicability and efficiency of Bayesian tools when applied to computationally demanding physical models. Theoretical and computational developments are demonstrated with applications drawn from molecular dynamics, structural dynamics and granular flow.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncertainty quantification methodology for hyperbolic systems with application to blood flow in arteries

We present a Stochastic Finite Volume - ADER (SFV-ADER) methodology for Uncertainty Quantification (UQ) in the general framework of systems of hyperbolic balance laws with uncertainty in parameters. The resulting method is weakly intrusive, meaning that deterministic solvers need minor modifications to include random contributions, and has no theoretical accuracy barrier. An illustration of the second-order version for the viscous Burgers equation with uncertain viscosity coefficient is first given in detail, under different deterministic initial conditions; the attainment of the theoretically expected convergence rate is demonstrated empirically; results and features of our scheme are discussed. We then extend the SFV-ADER method to a non-linear hyperbolic system with source terms that models one-dimensional blood flow in arteries, assuming uncertainties in a set of parameters of the problem. Results are then compared with measurements in a well-defined 1:1 experimental replica of the network of largest arteries in the human systemic circulation. For a 99%-confidence level, severe influence of parameter fluctuations is seen in pressure profiles, while secondary effects on flow rate profiles become visible, particularly in terminal branches. In conclusion, results suggest that the proposed methodology could successfully be applied to other physical problems involving hyperbolic balance laws.

60 APPLIED LIFE SCIENCES↗