Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

On the recovery of gravity anomalies from high precision altimeter data

A model for the recovery of gravity anomalies from high precision altimeter data is derived which consists of small correction terms to the inverse Stokes' formula. The influence of unknown sea surface topography in the case of meandering currents such as the Gulf Stream is discussed. A formula was derived in order to estimate the accuracy of the gravity anomalies from the known accuracy of the altimeter data. It is shown that for the case of known harmonic coefficients of lower order the range of integration in Stokes inverse formula can be reduced very much.

Lelgemann, D.↗

Advanced application flight experiments precision attitude determination system. Volume 2: System tests

The performance capability of each of two precision attitude determination systems (PADS), one using a strapdown star tracker, and the other using a single-axis gimbal star tracker was measured in the laboratory under simulated orbit conditions. The primary focus of the evaluation was on the contribution to the total system accuracy by the star trackers, and the effectiveness of the software algorithms in functioning with actual sensor signals. A brief description of PADS, the laboratory test configuration and the test facility, is given along with a discussion of the data handling and display, laboratory computer programs, PADS performance evaluation programs, and the strapdown and gimbal system tests. Results are presented and discussed.

Source record↗

Rapid and precise measurement of flatband voltage

The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held and read on a digital voltmeter.

Li, S. P.↗

Fixed-point single-precision estimation

Monte Carlo simulation of autonomous orbit determination has validated the use of an 18-bit NASA Standard Spacecraft Computer (NSSC) for the extended Kalman filter. Dimensionally consistent scales are chosen for all variables in the algorithm, such that nearly all of the onboard computation can be performed in single precision without matrix square root formulations. Allowable simplifications in algorithm implementation and practical means of ensuring convergence are verified for accuracies of a few km provided by star/vertical observations

Thompson, E. H.↗

Precision orbit computations for Starlette

The Starlette satellite, launched in February 1975 by the French Centre National d'Etudes Spatiales, was designed to minimize the effects of nongravitational forces and to obtain the highest possible accuracy for laser range measurements. Analyses of the first four months of global laser tracking data confirmed the stability of the orbit and the precision to which the satellite's position is established.

Marsh, J. G.↗

The computation of relative motion with increased precision

Encke's method as modified by Potter to increase the accuracy of orbit computations of gravitationally interacting bodies is applied to the problem of relative motion of non-interacting space vehicles. This technique is then combined with a simple transformation of the independent variable to arrive at a system of equations from which the relative motion may be determined with increased precision.

Nacozy, P.↗

Precision insolation measurement under field conditions

The paper describes a precision insolation instrument - the Mark 3 Kendall Radiometer - developed for field survey work and for use as a calibration transfer standard. The instrument, which can be used to make accurate measurements of solar irradiance, has a windowless black cavity receptor mounted in a massive heat sink and has equal sensitivity to ultraviolet, infrared, and visible radiation. Attention is given to a calibration stability analysis over two years of operation.

Reid, M. S.↗

Transmission media effects on precise Doppler tracking

The effects of the transmission media - the earth's troposphere and ionosphere, and the solar wind - on precise Doppler tracking are discussed. The charged particle effects can be largely removed by dual frequency observations; however there are limitations to these corrections (besides system noise and/or finite integration times) including the effects of magnetic fields, diffraction, and differential refraction, all of which must be carefully evaluated. The earth's troposphere can contribute an error of delta f/f approximately 10 to the minus 14th power.

Callahan, P. S.↗

A precision measurement of the X-ray polarization of the Crab Nebula without pulsar contamination

The linear X-ray polarization of the Crab Nebula has been precisely measured at 2.6 keV and 5.2 keV with the OSO 8 graphite crystal polarimeters. The 1.4 ms time resolution of these instruments permitted the removal of any contribution to the polarization from the pulsar. The nebular polarization is 19.2% plus or minus 1.0% at a position angle of 156.4 plus or minus 1.4 deg at 2.6 keV. At 5.2 keV the corresponding results are 19.5% plus or minus 2.8% at 152.6 plus or minus 4.0 deg.

Weisskopf, M. C.↗

Precision orbit computations for Starlette

The Starlette satellite, launched in February 1975 was designed to minimize the effects of nongravitational forces and to obtain the highest possible accuracy for laser range measurements. Analyses of the first four months of laser tracking data from nine stations have confirmed the stability of the orbit and the precision to which the satellite's position can be established. Initial orbit computations using the GSFC GEM - 7 gravity model produced rms fits of about 8 to 10 meters for arc lengths of 5 days. After tailoring a gravity model specifically to Starlette, the rms fits for the 5 day arcs were reduced significantly to the 1 to 2 meter level. An rms fit of 4.3 meters was obtained for a 90 day arc. Five day arcs overlapped by 2.5 days showed rms satellite position differences generally less than 2 meters. Prediction errors at the end of two months were less than 30 milliseconds.

Marsh, J. G.↗

Precision pointing and tracking system /PPTS/

As part of its advanced development work, JPL is developing a Precision Pointing and Tracking System (PPTS) for science platform control on unmanned planetary spacecraft. The PPTS will extend science capabilities on future missions by providing highly accurate (10 arcsec) and stable (0.2 arcsec) pointing of the platform. Key features of the design include closed-loop tracking of target bodies using an optical sensor and decoupling of spacecraft dynamics via high-bandwidth, inertially stabilized control. This paper discusses the analyses and design. Computer simulations were used to establish the feasibility of the design approach and to verify that the performance requirements can be met. A breadboard demonstration of the entire system is expected in late 1980.

Brown, T. K.↗

A technique for the assessment of fighter aircraft precision controllability

Today's emerging fighter aircraft are maneuvering as well at normal accelerations of 7 to 8 g's as their predecessors did at 4 to 5 g's. This improved maneuvering capability has significantly expanded their operating envelope and made the task of evaluating handling qualities more difficult. This paper describes a technique for assessing the precision controllability of highly maneuverable aircraft, a technique that was developed to evaluate the effects of buffet intensity on gunsight tracking capability and found to be a useful tool for the general assessment of fighter aircraft handling qualities. It has also demonstrated its usefulness for evaluating configuration and advanced flight control system refinements. This technique is believed to have application to future aircraft dynamics and pilot-vehicle interface studies.

Sisk, T. R.↗

Precision attitude determination for multimission spacecraft

Attitude determination algorithms for a multimission spacecraft are derived and their performance analyzed. The attitude determination system is composed of a strapdown Inertial Reference Unit (IRU), two fixed head star trackers, and an onboard computer. IRU data is processed to maintain real-time knowledge of spacecraft attitude relative to an inertial reference frame. Star tracker data is processed using Kalman filtering techniques to estimate and correct the attitude determination errors and the gyro drift compensation errors. The results of a star availability analysis for stellar, solar and earth pointing missions are presented. Linear covariance analysis techniques are used to evaluate nominal attitude determination performance, the effects of sensor measurement accuracy variations, the effects of errors in knowledge of sensor measurement accuracy, and the effects of star tracker misalignment errors. Results of a nonlinear simulation analysis of attitude determination performance are also presented. These analyses show that precision attitude determination for stellar, solar and earth pointing missions is achieved.

Murrell, J. W.↗

Precision scriber

Device scribes fine lines to precise tolerances on flat or round surfaces. Scriber is used in conjunction with toolmaker's microscope and will scribe metal of nonmetallic surfaces. When not in use, scriber is easily retracted or swung out of way so microscope can be used for other purposes.

Buzzard, R. J.↗

The Precision Self-Metering Structure (PSMS)

Large, precise space systems such as space lasers, space telescopes, and space power transmitters cannot be realized until certain fundamental meteorological problems are first solved. It must be shown: (1) how a spatially distributed system of elements can be tied together in terms of a master coordinate system, (2) how master coordinates for these distributed elements can be determined with great accuracy, and (3) how mechanical integration of the elements to desired master coordinates of such accuracy can be achieved. Solutions to these problems are discussed.

Yager, W. C.↗

Numerical precision and data structures

Technical proposals and recommendations for revising FORTRAN were studied and categorized. In the area of numerical precision, the proposals basically agree on a set of necessary parameters, although a wide range of nomenclature and specific function names are used. Environmental parameters identified include the following: (1) base of floating point representation, (2) largest positive real number, exponent and integer, (3) largest negative real number, exponent and integer, (4) number of significant digits, and (5) exponent bias.

Schenk, W.↗

High-precision gravimetric survey in support of lunar laser ranging at Haleakala, Maui, 1976 - 1978

The planning, observations and adjustment of high-precision gravity survey networks established on the islands of Maui and Oahu as part of the geodetic-geophysical program in support of lunar laser ranging at Haleakala, Maui, Hawaii are described. The gravity survey networks include 43 independently measured gravity differences along the gravity calibration line from Kahului Airport to the summit of Mt. Haleakala, together with some key points close to tidal gauges on Maui, and 40 gravity differences within metropolitan Honolulu. The results of the 1976-1978 survey are compared with surveys made in 1961 and in 1964-1965. All final gravity values are given in the system of the international gravity standardization net 1971 (IGSN 71); values are obtained by subtracting 14.57 mgal from the Potsdam value at the gravity base station at the Hickam Air Force Base, Honolulu.

Schenck, B. E.↗

Precision temperature gradient measurements on window glass

Surface temperature gradients were measured with miniature thermocouples installed in a 58.5 cm (23-inch) square window. Test measurements at 25 locations were made under vacuum and with the window operating in radiant heat transfer mode. The analysis of thermocouple design and installation is presented along with a lead wire routing scheme to allow for both differential and absolute temperature measurements while using a minimum number of signal feedthru paths through the test chamber wall. Typical test data and operational precautions are presented along with the accuracy analysis for installation effects and measurement effects to support differential temperature measurement precision values of + or - 0.06 C RMS + or - 0.1 F RMS).

Mikk, G.↗