Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Porous flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Large-scale aeroacoustic research feasibility and conceptual design of test-section inserts for the Ames 80- by 120-foot wind tunnel

An engineering feasibility study was made of aeroacoustic inserts designed for large-scale acoustic research on aircraft models in the 80 by 120 foot Wind Tunnel at NASA Ames Research Center. The advantages and disadvantages of likely designs were analyzed. Results indicate that the required maximum airspeed leads to the design of a particular insert. Using goals of 200, 150, and 100 knots airspeed, the analysis indicated a 30 x 60 ft open-jet test section, a 40 x 80 ft open jet test section, and a 70 x 100 ft closed test section with enhanced wall lining, respectively. The open-jet inserts would be composed of a nozzle, collector, diffuser, and acoutic wedges incorporated in the existing 80 x 120 test section. The closed test section would be composed of approximately 5 ft acoustic wedges covered by a porous plate attached to the test section walls of the existing 80 x 120. All designs would require a double row of acoustic vanes between the test section and fan drive to attenuate fan noise and, in the case of the open-jet designs, to control flow separation at the diffuser downstream end. The inserts would allow virtually anechoic acoustic studies of large helicopter models, jets, and V/STOL aircraft models in simulated flight. Model scale studies would be necessary to optimize the aerodynamic and acoustic performance of any of the designs. In all designs studied, the existing structure would have to be reinforced. Successful development of acoustically transparent walls, though not strictly necessary to the project, would lead to a porous-wall test section that could be substituted for any of the open-jet designs, and thereby eliminate many aerodynamic and acoustic problems characteristic of open-jet shear layers. The larger size of the facility would make installation and removal of the insert components difficult. Consequently, scheduling of the existing 80 x 120 aerodynamic test section and scheduling of the open-jet test section would likely be made on an annual or longer basis. The enhanced wall-lining insert would likely be permanent. Although the modifications are technically feasible, the economic practicality of the project was not evaluated.

Soderman, Paul T.↗

On the effect of pressure, oxygen concentration, air flow and gravity on simulated pool fires

The initial development of a fire is characterized by the establishment of a diffusion flame over the surface of a the condensed fuel and is particularly influenced by gravity, with most of the gaseous flow induced by natural convection. Low initial momentum of the fuel vapor, strong buoyant flows induced by the hot post-combustion gases and consequently low values of the Froude number (inertia-gravity forces ratio) are typical of this kind of scenario. An experimental study is conducted by using a porous burner to simulate the burning of a horizontal combustible surface. Ethane is used as fuel and different mixtures of oxygen and nitrogen as oxidizer. The magnitude of the fuel injection velocities is restricted to values that will keep the Froude number on the order of 10-5, when calculated at normal gravity and pressure, which are characteristic of condensed fuel burning. Two different burners are used, a circular burner (62 mm diameter) placed inside a cylindrical chamber (0.3 m diameter and 1.0 m height) and a rectangular burner (50 mm wide by 200 mm long) placed in a wind tunnel (350 mm long) of rectangular cross section (120 mm wide and 90 mm height). The first burner is used to study the effect of pressure and gravity in the absence of a forced flow parallel to the surface. The second burner is used to study the effect of a forced flow parallel to the burner surface as well as the effect of oxygen concentration in the oxidizer flow. In this case experiments are also conducted at different gravity levels (micro-gravity, 0.2 g(sub 0), g(sub 0) and 1.8 g(sub 0)) to quantify the relative importance of buoyancy.

Torero, J. L.↗

Analysis of coolant entrance boundary shape of porous region to control cooling along exit boundary

A cooled porous region has a plane surface exposed to a specified spatially varying heat flux. The coolant leaves the region through this surface, and it is desired to control the flow distribution to maintain a specified uniform surface temperature. This is accomplished by having the coolant entrance surface shaped to provide in the region the necessary variation of path length and, hence, flow resistance. The surface shape at the coolant entrance is found by solving a Cauchy boundary value problem. An exact solution is obtained that will deal with a wide variety of heating distributions for both two- and three-dimensional shapes.

Siegel, R.↗

Crystallization, sublimation, and gas release in the interior of a porous comet nucleus

A numerical code is developed for evolutionary calculations of the thermal structure and composition of a porous comet nucleus made of water ice, in amorphous or crystalline form, other volatiles, dust, and gases trapped in amorphous ice. Bulk evaporation, crystallization, gas release, and free (Knudsen) flow of gases through the pores are taken into account. The numerical scheme yields exact conservation laws for mass and energy. The code is used to study the effect of bulk evaporation of ice in the interior of a comet nucleus during crystallization. It is found that evaporation controls the temperature distribution; the vapor prevents cooling of the crystallized layer of ice, by recondensation and release of latent heat. Thus high temperatures are maintained below the surface of the nucleus and down to depths of tens or hundreds of meters, even at large heliocentric distances, as long as crystallization goes on. Gas trapped in the ice and released during the phase transition flows both toward the interior and toward the surface and out of the nucleus. The progress of crystallization is largely determined by the contribution of gas fluxes to heat transfer.

Prialnik, Dina↗

Testing of Commercial Hollow Fiber Membranes for Space Suit Water Membrane Evaporator

Three commercial-off-the-shelf (COTS) hollow fiber (HoFi) membrane evaporators, modified for low pressure, were tested in a vacuum chamber at pressures below 33 pascals as potential space suit water membrane evaporator (SWME) heat rejection technologies. Water quality was controlled in a series of 25 tests, first simulating potable water reclaimed from waste water and then changing periodically to simulate the ever concentrating make-up of the circulating coolant over that is predicted over the course of 100 EVAs. Two of the systems, comprised of non-porous tubes with hydrophilic molecular channels as the water vapor transport mechanism, were severely impacted by the increasing concentrations of cations in the water. One of the systems, based on hydrophobic porous polypropylene tubes was not affected by the degrading water quality, or the presence of microbes. The polypropylene system, called SWME 1, was selected for further testing. An inverse flow configuration was also tested with SWME 1, with vacuum exposure on the inside of the tubes, provided only 20% of the performance of the standard configuration. SWME 1 was also modified to block 50% and 90% of the central tube layers, and tested to investigate performance efficiency. Performance curves were also developed in back-pressure regulation tests, and revealed important design considerations arising from the fully closed valve. SWME 1 was shown to be insensitive to air bubbles injected into the coolant loop. Development and testing of a full-scale prototype based on this technology and these test results is in progress.

Bue, Grant C.↗

Effect of Out-Gassing on the Onset of Hypersonic Boundary Layer Transition

Prediction and control of the onset of transition and the associated variation in aerothermodynamic parameters in high-speed flows is key to optimize the performance and design of Thermal Protection Systems (TPS) of next-generation aerospace vehicles [1]. Boundary Layer Transition (BLT) characteristics can influence the surface heating budget determining the TPS thickness and consequently its weight penalty. Ablative heatshields are designed to alleviate the high heat flux at the surface through pyrolysis of their polymeric matrix and subsequent fiber ablation [2]. Pyrolysis leads to out-gassing and non-uniform ablation lead to surface roughness, both of which are known to influence the transition process. An ablator impacts BLT through three main routes: gas injecting into the boundary layer from the wall, changing the surface heat transfer due to wall-flow chemical reactions, and modifying surface roughness [3]. In preparation to Mars 2020 mission post-flight analysis, the predictive transition capability has been initiated toward hard-coupling porous material response analysis and aerothermal environment calculation.

Karimi, Mona↗

Comparison of theoretical and experimental boundary-layer development in a Mach 2.5 mixed-compression inlet

An analytical investigation was made of the boundary layer flow in an axisymmetric Mach 2.5 mixed compression inlet, and the results were compared with experimental measurements. The inlet tests were conducted in the Lewis 10- by 10-foot supersonic wind tunnel at a unit Reynolds number of 8.2 million/m. The inlet incorporated porous bleed regions for boundary layer control, and the effect of this bleed was taken into account in the analysis. The experimental boundary layer data were analyzed by using similarity laws from which the skin friction coefficient was obtained. The boundary layer analysis included predictions of laminar and turbulent boundary layer growth, transition, and the effects of the shock boundary layer interactions. In addition, the surface static pressures were compared with those obtained from an inviscid characteristics program. The results of investigation showed that the analytical techniques gave satisfactory predictions of the boundary layer flow except in regions that were badly distorted by the terminal shock.

Hingst, W. R.↗

Influence of porous-wall thermal effectiveness on turbulent-boundary-layer heat transfer

In view of the interest in employing porous wall materials for which the wall thermal effectiveness is less than unity, the influence of the effectiveness on the convective heat-transfer coefficient is examined. A Couette-flow model of the turbulent boundary layer shows that the familiar expression for the Stanton number with mass transfer at the boundary is modified by a correction factor that accounts for the wall thermal effectiveness and the effectiveness of the film layer in protecting the surface from the hot gas stream. The correction term is found be of considerable importance for low values of blowing rate and wall thermal effectiveness.

Lecuyer, M. R.↗

Reciprocating Magnetic Refrigerator

Unit cools to 4 K by adiabatic demagnetization. Two porous matrices of paramagnetic material gadolinium/gallium/garnet held in long piston called displacer, machined out of Micarta (phenol formaldehyde polymer). Holes in side of displacer allow heat-exchange fluid to flow to and through matrices within. Piston seals on displacer prevent substantial mixing of fluid in two loops. Magnetic refrigerator provides continuous rather than "one-shot" cooling.

Johnson, D. L.↗

TranAir: A full-potential, solution-adaptive, rectangular grid code for predicting subsonic, transonic, and supersonic flows about arbitrary configurations. User's manual

The TranAir computer program calculates transonic flow about arbitrary configurations at subsonic, transonic, and supersonic freestream Mach numbers. TranAir solves the nonlinear full potential equations subject to a variety of boundary conditions modeling wakes, inlets, exhausts, porous walls, and impermeable surfaces. Regions with different total temperature and pressure can be represented. The user's manual describes how to run the TranAir program and its graphical support programs.

Johnson, F. T.↗

Porous airfoil and process

A porous airfoil having venting cavities with contoured barrier walls, formed by a core piece, placed beneath a porous upper and lower surface area that stretches over the nominal chord of an airfoil is employed, to provide an airfoil configuration that becomes self-adaptive to very dissimilar flow conditions to thereby improve the lift and drag characteristics of the airfoil at both subcritical and supercritical conditions.

Hartwich, Peter M.↗

Investigation to optimize the passive shock wave-boundary layer control for supercritical airfoil drag reduction

The optimization of passive shock wave/boundary layer control for supercritical airfoil drag reduction was investigated in a 3 in. x 15.4 in. Transonic Blowdown Wind Tunnel. A 14% thick supercritical airfoil was tested with 0%, 1.42% and 2.8% porosities at Mach numbers of .70 to .83. The 1.42% case incorporated a linear increase in porosity with the flow direction while the 2.8% case was uniform porosity. The static pressure distributions over the airfoil, the wake impact pressure data for determining the profile drag, and the Schlieren photographs for porous surface airfoils are presented and compared with the results for solid-surface airfoils. While the results show that linear 1.42% porosity actually led to a slight increase in drag it was found that the uniform 2.8% porosity can lead to a drag reduction of 46% at M = .81.

Nagamatsu, H. T.↗

Forced cocurrent smoldering combustion

An analytical model of cocurrent smoldering combustion through a very porous solid fuel is developed. Smoldering is initiated at the top of a long radially insulated uniform fuel cylinder, so that the smolder wave propagates downward, opposing an upward-forced flow of oxidizer, with the solid fuel and the gaseous oxidizer entering the reaction zone from the same direction (hence, cocurrent). Radiative heat transfer was incorporated using a diffusion approximation, and smoldering was modeled using a one-step reaction mechanism. The results indicate that, for a given fuel, the final temperature depends only on the initial oxygen mass flux, increasing logarithmically with the mass flux. The smolder velocity is linearly dependent on the initial oxygen mass flux, and, at a fixed value of the flux, increases with initial oxygen mass fraction. The mathematical relationship determining the conditions for steady smolder propagation is presented.

Dosanjh, Sudip S.↗

Icing tunnel tests of a glycol-exuding porous leading edge ice protection system on a general aviation airfoil

A glycol-exuding porous leading edge ice protection system was tested. Results show that the system is very effective in preventing ice accretion (anti-ice mode) or removing ice from an airfoil. Minimum glycol flow rates required for anti-icing are a function of velocity, liquid water content in the air, ambient temperature, and droplet size. Large ice caps were removed in only a few minutes using anti-ice flow rates. It was found that the shed time is a function of the type of ice, size of the ice cap, angle of attack, and glycol flow rate. Wake survey measurements show that there is no significant drag penalty for the installation or operation of the system tested.

Kohlman, D. L.↗

A summary of porous tube plant nutrient delivery system investigations from 1985 to 1991

The Controlled Ecological Life Support System (CELSS) Program is a research effort to evaluate biological processes at a one person scale to provide air, water, and food for humans in closed environments for space habitation. This program focuses currently on the use of conventional crop plants and the use of hydroponic systems to grow them. Because conventional hydroponic systems are dependent on gravity to conduct solution flow, they cannot be used in the microgravity of space. Thus, there is a need for a system that will deliver water and nutrients to plant roots under microgravity conditions. The Plant Space Biology Program is interested in investigating the effect that the space environment has on the growth and development of plants. Thus, there is also a need to have a standard nutrient delivery method for growing plants in space for research into plant responses to microgravity. The Porous Tube Plant Nutrient Delivery System (PTPNDS) utilizes a hydrophilic, microporous material to control water and nutrient delivery to plant roots. It has been designed and analyzed to support plant growth independent of gravity and plans are progressing to test it in microgravity. It has been used successfully to grow food crops to maturity in an earth-bound laboratory. This document includes a bibliography and summary reports from the growth trials performed utilizing the PTPNDS.

Dreschel, T. W.↗

Reciprocating magnetic refrigerator employing tandem porous matrices within a reciprocating displacer

Disclosed is a method and apparatus for a magnetic refrigeration system. A continuously reciprocating displacer houses at least a pair of paramagnetic substances each of which is alternately driven into and out of a magnetic field. Two separate bidirectional pumping systems flow helium gas through the displacer and through both paramagnetic substances to create heat exchange conditions at two separate temperature extremes.

Johnson, D. L.↗

A hydroponic method for plant growth in microgravity

A hydroponic apparatus under development for long-term microgravity plant growth is described. The capillary effect root environment system (CERES) is designed to keep separate the nutrient and air flows, although both must be simultaneously available to the roots. Water at a pressure slightly under air pressure is allowed to seep into a plastic depression covered by a plastic screen and a porous membrane. A root in the air on the membrane outer surface draws the moisture through it. The laboratory model has a wire-based 1.241 mm mesh polyethylene screen and a filter membrane with 0.45 micron pores, small enough to prohibit root hair penetration. The design eliminates the need to seal-off the plant environment. Problems still needing attention include scaling up of the CERES size, controlling biofouling of the membrane, and extending the applications to plants without fibrous root systems.

Wright, B. D.↗