Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Photon-counting array detectors for space and ground-based studies at ultraviolet and vacuum ultraviolet /VUV/ wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric photon-counting array detectors, with formats as large as (256 x 1024)-pixels that can be operated in a windowless configuration at vacuum ultraviolet (VUV) and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. This paper describes the construction and modes of operation of (1 x 1024)-pixel and (24 x 1024)-pixel MAMA detector systems that are being built and qualified for use in sounding-rocket spectrometers for solar and stellar observations at wavelengths below 1300 A. The performance characteristics of the MAMA detectors at ultraviolet and VUV wavelengths are also described.

Timothy, J. G.↗

Photon counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location. Previously announced in STAR as N82-19118

Hartig, G. F.↗

Single-pulse gas thermometry at low temperatures using two-photon laser-induced fluorescence in NO-N2 mixtures

A technique suitable for measuring fluctuating temperatures in supersonic turbulent flows of N2 seeded with NO has been demonstrated in a nonflowing cell. The method relies on the two photon excitation of two selected ro-vibronic transitions in the NO gamma (alpha 2 sigma+, v prime = 0 yields ch1zp1, v double prime = 0). Previously announced in STAR as N83-20079

Gross, K. P.↗

Direct-Photon-Detection Communications

Optical communications system based on direct detection of photons rather than heterodyning of carrier with local oscillator. Direct-detection system uses single laser source, pulse-position modulation, and Reed-Solomon coding to protect against burst errors. Conventional photomultiplier tube is receiver. Technology applicable to terrestrial communications.

Lesh, J. R.↗

Multipurpose Photonic Transducers

Features include smallness and noise immunity. Photonic transducer is interferometer with two arms. Small relative axial motions of mirrors detected as shifts in interference pattern. Version measures temperature changes via differential expansion or contraction of stalks. New transducers smaller (typical size less than 1 cm) and coupled to monitoring equipment with optical fibers instead of wires. Well suited to biomedical instrumentation.

Du Fresne, E. R.↗

Comparative lifetesting results for microchannel plates in windowless EUV photon detectors

Microchannel plates (MCPs) from seven manufacturers were subjected to a series of tests to determine their suitability for the Extreme Ultraviolet Explorer satellite. Comparative data are presented for sixteen MCP tandem pairs with channel length to diameter ratios (l/d) ranging from 40:1 to 60:1 and for two saturable (curved channel) MCPs with l/d's of 80:1. Results for MCPs with funnelled channel throats are also discussed. Properties of the MCPs which were monitored include: background count rate, output charge pulse height distribution (PHD), modal gain, PHD full width half maximum (FWHM), and extreme ultraviolet (EUV) photon quantum efficiency. Five detectors were chosen for further lifetime testing consisting of a mild bake to 100 C, and charge extraction to 0.01 coulombs, repeated high voltage cycling and reexposure to one atmosphere conditions. The results of these tests and their implications for the flight detectors are discussed. Erratic events in the detector background were recorded, probably due to field emission from high voltage surfaces or the absorption of water vapor into the electrode following exposure to air. The steps taken to control the detector background are discussed.

Malina, R. F.↗

Measurement of spine and total body mineral by dual-photon absorptiometry

The use of Gd-153 dual-photon absorptiometry at 43 and 100 keV to measure individual-bone and total-body bone minerals is discussed in a survey of recent studies on humans, phantoms, and monkeys. Precision errors of as low as 1 percent have been achieved in vivo, suggesting the use of sequential measurements in studies of immobilization and space-flight effects.

Mazess, R. B.↗

Polarization of Comptonized photons

The polarization of Comptonized X-rays as a function of energy and emission angle is obtained. The geometry utilized is that of the semi-infinite plane with the source photons located on a plane at a finite optical depth below the surface. It is further shown what information is obtainable from polarization measurements at only two different energies. The observed values for the X-ray sources Cyg X-1 and Sco X-1 are used to illustrate the calculations.

Williams, A. C.↗

Absolute two-photon excitation cross-sections in NO

A technique has been developed which allows the determination of a two-photon absorption cross-section to be made relative to the Raman scattering cross-section in nitrogen. Spatial and temporal effects associated with the lasers are ratioed out to give a result independent of laser parameters. The necessary theory to extract a cross-section from the measured ratio of a Coherent Anti-Stokes Raman Scattering (CARS) signal in N2 to a four-wave mixing signal in NO has been developed. The technique has been demonstrated on the R(22) + S(12) (J-double-prime = 9 1/2) line in NO and a cross-section of (2.9 + or - 1.8) x 10 to the -49th (cm to the 4th power)-s was determined. This technique appears to be applicable to a number of other diatomic molecules.

Burris, J.↗

Experimental tests of a single-photon calorimeter for X-ray spectroscopy

Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.

Mccammon, D.↗

Velocity-changing collisional effects in nonlinear atomic spectroscopy and photon echo decay in gases

A general theory of atomic dipole coherence under the influence of collisional phase changes, inelastic effects and optically active atom velocity changes, including those due to anisotropic interactions is presented. Velocity change effects are obtained in closed form. Line shapes appear as convolutions of standard pressure broadening contours with velocity-change contours. Width and shift parameters for the He-broadened Na D lines at 2 m bar pressure, 380 K are calculated, as are He-induced photon echo decay rates for these lines. Overall agreement with xperiment is reasonably good.

Herman, R. M.↗

Gain Instabilities in Photomultipliers: How Accurate are Photon Counting Measurements?

Experiments performed on five commercially available photomultiplier tubes indicate that gain instabilities can be an important source of error in photon counting measurements at the 1% level. It is shown that the error cannot be significantly reduced by standard differential measurement techniques. Analysis of time variations in the pulse height distribution is shown to be a sensitive diagnostic tool for the measurement of gain variations. Using this technique it is found that gain variations occur at counting rates as low as 100 Hz. It is argued that such errors will be present at some level in all tubes. Several calibrating schemes capable of reducing the error to below the 0.1% level are discussed.

Rosen, W. A.↗

Detection and Symbol Synchronization for Multiple-bit Per Photon Optical Communications

Methods of detection and synchronization in a highly efficient direct detection optical communication system are reported. Results of measurements on this moderate-rate demonstration system capable of transmitting 2.5 bits/detected photon in low-background situations indicate that symbol slot synchronization is not a problem, and that a simple symbol detection scheme is adequate for this situation. This system is a candidate for interplanetary optical communications.

Marshall, W. K.↗

Photon Detection with Cooled Avalanche Photodiodes: Theory and Preliminary Experimental Results

Avalanche photodiodes (APDs) can be operated in a geiger-tube mode so that they can respond to single electron events and thus be used as photon counting detectors. Operational characteristics and theory of APDs while used in this mode are analyzed and assessed. Preliminary experimental investigation of several commercially available APDs has commenced, and initial results for dark count statistics are presented.

Robinson, D. L.↗

Photon-counting image sensors for the ultraviolet

An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).

Jenkins, E. B.↗

Observations of solar flare photon energy spectra from 20 keV to 7 MeV

Solar flare photon energy spectra in the 20 keV to 7 MeV range are derived from the Apr. 1, Apr. 4, apr. 27 and May 13, 1981 flares. The flares were observed with a hard X-ray and a gamma-ray spectrometers on board the Hinotori satellite. The results show that the spectral shape varies from flare to flare and the spectra harden in energies above about 400 keV. Effects of nuclear line emission on the continuum and of higher energy electron bremsstrahlung are considered to explain the spectral hardening.

Yoshimori, M.↗