Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

NASA Astrophysics Technology Gaps, Prioritization, and Development

Physics of the Cosmos (PCOS) X-ray astrophysics: grazing-angle mirrors, optical blocking filters, fast event ID, gratings, micro-calorimeters, radiation-tolerant detectorsGravitational-wave astrophysics: phase measurement system, micro-Newton thrusters, non-contact charge-management system, stable laser system, low-stray-light telescope Cosmic Microwave Background (CMB): superconducting FPAs and optical elements (cryo filters and coatings)Cosmic Origins (COR)UV/Optical/IR: Next-gen detectors, ultra-stable high-precision telescope systems (including mirrors, thermal control, structures, metrology, etc.), and advanced UV coatingsFar-IR: Heterodyne detectors, advanced cooling systems, ultra-sensitive detectors and large arraysLarge Space Optics: As discussed earlier by Mario Perez, the Program Office supports HQ in monitoring/tracking the Segmented Mirror Technology Program (SMTP) and other technology development projects targeting large space telescopes

Ganel, Opher↗

Role of metabolic gases in bubble formation during hypobaric exposures

Our hypothesis is that metabolic gases play a role in the initial explosive growth phase of bubble formation during hypobaric exposures. Models that account for optimal internal tensions of dissolved gases to predict the probability of occurrence of venous gas emboli were statistically fitted to 426 hypobaric exposures from National Aeronautics and Space Administration tests. The presence of venous gas emboli in the pulmonary artery was detected with an ultrasound Doppler detector. The model fit and parameter estimation were done by using the statistical method of maximum likelihood. The analysis results were as follows. 1) For the model without an input of noninert dissolved gas tissue tension, the log likelihood (in absolute value) was 255.01. 2) When an additional parameter was added to the model to account for the dissolved noninert gas tissue tension, the log likelihood was 251.70. The significance of the additional parameter was established based on the likelihood ratio test (P < 0.012). 3) The parameter estimate for the dissolved noninert gas tissue tension participating in bubble formation was 19. 1 kPa (143 mmHg). 4) The additional gas tissue tension, supposedly due to noninert gases, did not show an exponential decay as a function of time during denitrogenation, but it remained constant. 5) The positive sign for this parameter term in the model is characteristic of an outward radial pressure of gases in the bubble. This analysis suggests that dissolved gases other than N2 in tissues may facilitate the initial explosive bubble-growth phase.

NASA Center JSC↗

An amplitude modulated laser system for distance and displacement measurement

A laser distance and displacement measurement system is being developed to monitor small displacements in large space structures for strain analysis and structural control. The reflected laser beam is focused on a detector and the detected signal is mixed with the reference. Small displacements are indicated by a change in modulation frequency which is adjusted to maintain quadrature between the received signal and the reference signal from the voltage-controlled oscillator in a phase-locked loop. Measurement of absolute distance is accomplished by sweeping the modulation frequency from a quadrature lock point to an adjacent lock point.

Rogowski, Robert S.↗

Infrared astronomy from the Moon

The purpose of this paper is to exhibit the advantages and limitations to infrared astronomical observations form the moon. The most obvious apparent advantage is the lack of a lunar atmosphere; radiation arriving from the universe is neither extinguished nor refracted as it approaches the lunar surface. However, the Earth's atmosphere's protection against cosmic rays is also lost, and infrared detectors are highly sensitive to irradiation by energetic particles. A second apparent advantage is the relative ease with which beams from an array of telescopes can be interferometrically combined; again the vacuum environment with constant refractive index of unity throughout, permits combination without phase delay across the entire spectral range. But thermal radiation from optical components and stray radiation from the lunar environment, just outside the light path, tend to lessen that advantage, except in narrow-spectral-band spatial interferometry, in which only the radiation in individual spectral lines is mapped, and broad-band thermal emission can be effectively filtered out. On the Moon's night side, and in polar craters on the Moon, radiative cooling should permit the attainment of high sensitivity with large telescopes. Just as the proposed Edison spacecraft primary mirror is expected to reach temperatures around 40 K, so also large lunar primary mirrors might be expected to reach temperatures in that range, making the zodiacal glow the main source of noise at wavelengths shortward of 25 micrometers. The slow rota tion of the Moon, and the lack of vibrations from natural sources such as winds, should provide advantages in guiding on specific astronomical sources. To learn as much as possible about the difficulties of remote observations in a hostile environment, Antarctic observatories should be used as test beds for the rigors of lunar observations. The strenuous requirements for successful astronomical observations from the South Pole are similar to those expected to be encountered in observations conducted from the Moon.

Harwit, Martin↗

Noise Budget for the X-Ray Microcalorimeter Spectrometer (XMS) Core Array

The purpose of this document is to present and archive the noise budget for the XMS detector, in order, at this stage in mission planning, to learn the scale of the requirements placed on the other instrument subsystems. This document mainly concerns the core array, specifically the baseline version that emerged from the trade studies associated with the ESA Phase A study report. Qualitative extension to the Hydra approach to the outer array is included at the end.

Kilbourne, Caroline Anne↗

Definition phase study of the grand tour missions

The research to define an energetic particle experiment for the OPTGT-MJS missions is reported. The studies reported include: (1) the use of silicon dectectors for low energy, low flux level measurements in the presence of RTG radiation and trapped electrons, (2) high energy proton damage of lithium-drifted and surface barrier silicon detectors, (3) the gas Cerenkov counter, (4) systems for detection of trapped high-energy protons in the presence of trapped electrons, and (5) reliability and redundancy.

Simpson, J. A.↗

A New Large-Well 1024x1024 Si:As Detector for the Mid-Infrared

We present a description of a new 1024x1024 Si:As array designed for ground-based use from 5 - 28 microns. With a maximum well depth of 5e6 electrons, this device brings large-format array technology to bear on ground-based mid-infrared programs, allowing entry to the mega-pixel realm previously only accessible to the near-IR. The multiplexer design features switchable gain, a 256x256 windowing mode for extremely bright sources, and it is two-edge buttable. The device is currently in its final design phase at DRS in Cypress, CA. We anticipate completion of the foundry run in October 2005. This new array will enable wide field, high angular resolution ground-based follow up of targets found by space-based missions such as the Spitzer Space Telescope and the Wide-field Infrared Survey Explorer (WISE).

astronomy↗

Orbiting Space Interferometer (OSI): A first generation space interferometer

The technical requirements and performance of a first generation space interferometer is discussed. The performance of an interferometer, sensitivity, field of view, dynamic range, astrometric accuracy, etc, in space is set by what cannot be achieved for a ground-based instrument. For the Orbiting Space Interferometer (OSI), the nominal performance parameters are 20 mag sensitivity, field of view of approximately 500*500 pixels, a 1000:1 dynamic range in the image with one milliarcsec resolution, and an astrometric accuracy of 0.1 milliarcsec for wide angle astrometry and 10 microarcsec accuracy for narrow field astrometry (few degrees). OSI is a fully phased interferometer where all critical optical paths are controlled to 0.05 wavelengths. The instrument uses two guide interferometers locked on bright stars several degrees away to provide the spacecraft attitude information needed to keep the fringes from the faint science object stable on the detector.

Shao, Michael↗

Detectability of the Reflection Signal from Inner Planets

Mayor and Queloz (1996) and Marcy and Butler (1996) have found massive planets with orbital periods Tp=approx.4 days around two solar-like stars (51 Pegasi and v Andromeda). These planets are most likely similar in size and composition to the gas giants in our solar system (Burrows et al 1996). Based on this expectation and assuming the same albedo as Jupiter, we examined the feasibility of searching for similar planets with a dedicated space-based 1-m telescope. The Kepler mission will survey approximately 70,000 main-sequence dwarf stars from 9 to 14 mag continuously for four years to detect transiting Earthlike planets. Based on the detection statistics of Marcy and Butler, we expect to detect 1400 inner-orbit giant planets. Such planets in a much wider range of orbital inclinations (i) will produce nearly sinusoidal modulations of the star light flux due to the varying planetary phases. The relative signal amplitudes are of order 2x10(exp -5) and decrease as Tp(exp 4/3) for i >> 0deg. We estimated the expected signal to noise ratio (SNR) using the solar irradiance measurements from the ACRIM 1 experiment along with expected shot and detector noises. The figure shows SNR as a function of Tp for a 12 mag star, and indicates the planet radius required for detection. The survey will be sensitive to planets with periods from 12 hr to approx.8 days at the 6 sigma level.

Borucki, W. J.↗

X-Ray Spectral Evolution of the Crab Pulse

The Crab Pulsar was observed with the X-ray detectors on the Rossi X-ray Timing Explorer (RXTE) on May 2, 1996. The large area, high time resolution, extended energy range, and moderate energy resolution of the RXTE instruments provided an unprecedented measurement of the Crab pulsar spectrum as it evolved in phase across the 33 msec pulse.

Crab Pulsar nebular↗

LISA Pathfinder and eLISA news

Two important gatherings of the space-based gravitational-wave detector community were held in Zurich, Switzerland this past March. The first was a meeting of the Science Working Team for LISA Pathfinder (LPF), a dedicated technology demonstrator mission for a future LISA-like gravitational wave observatory. LPF is entering an extremely exciting phase with launch less than 15 months away. All flight components for both the European science payload, known as the LISA Technology Package (LTP), and the NASA science payload, known as the Space Technology 7 Disturbance Reduction System (ST7-DRS), have been delivered and are undergoing integration. The final flight component for the spacecraft bus, a cold-gas thruster based on the successful GAIA design, will be delivered later this year. Current focus is on completing integration of the science payload (see Figures 1 and 2) and preparation for operations and data analysis. After a launch in Summer 2015, LPF will take approximately 90 days to reach its operational orbit around the Earth-Sun Lagrange point (L1), where it will begin science operations. After 90 days of LTP operations followed by 90 days of DRS operations, LPF will have completed its prime mission of paving the way for a space-based observatory of gravitational waves in the milliHertz band. Immediately following the meeting of the LPF team, the eLISA consortium held its third progress meeting. The consortium (www.elisascience.org) is the organizing body of the European space-based gravitational-wave community, and it was responsible for the "The Gravitational Universe" whitepaper that resulted in the November 2013 election of a gravitational-wave science theme for ESA's Cosmic Visions L3 opportunity. In preparation for an L3 mission concept call, which is expected later this decade, and for launch in the mid 2030s, the eLISA consortium members are coordinating technology development and mission study activities which will build on the LPF results. The final mission concept is expected to include some international (non-European) contributions, and NASA has expressed an interest in participating in this ground-breaking mission. The US research community supports such a collaboration, or any other mission scenario that achieves the high-priority science of a space-based gravitational-wave observatory at the earliest possible date.

pathfinder↗

Construction and testing of a Scanning Laser Radar (SLR), phase 2

The scanning laser radar overall system is described. Block diagrams and photographs of the hardware are included with the system description. Detailed descriptions of all the subsystems that make up the scanning laser radar system are included. Block diagrams, photographs, and detailed optical and electronic schematics are used to help describe such subsystem hardware as the laser, beam steerer, receiver optics and detector, control and processing electronics, visual data displays, and the equipment used on the target. Tests were performed on the scanning laser radar to determine its acquisition and tracking performance and to determine its range and angle accuracies while tracking a moving target. The tests and test results are described.

Flom, T.↗

Microwave profiling of snowpack free-water content

A microwave system is proposed to measure the amount of liquid-phase water in a snowpack operating in the range of 1 to 10 GHz. Attenuation of the beam between source and receivers is produced by the water in the snow. The relationships of frequency, distance, and volume percent of water are calculated for an assumed detector sensitivity, together with the estimated cost of a representative system. A laboratory test is described that shows the attenuation for snow at maximum wetness at 9.35 GHz. A configuration is proposed that involves a vertical tube containing microwave and radioactive sources and another vertical tube containing microwave and gamma-ray detectors, so that density and wetness profiles are obtained simultaneously over essentially the same path.

Linlor, W. I.↗

Synchronous Photodiode-Signal Sampler

Synchronous sampling circuit increases signal-to-noise ratio of measurements of chopped signal of known phase and frequency in presence of low-frequency or dc background noise. Used with linear array of photoelectric sensors for locating edge of metal plate. Multiplexing circuit cycles through 16 light-emitting-diode/photodiode pairs, under computer control. Synchronized with multiplexer so edge detector makes one background-subtracted signal measurement per emitter/detector pair in turn.

Primus, Howard K.↗

35-45 Giga Hertz Transceiver System for Phase and Magnitude Detection

Nondestructive evaluation (NDE) is the science and practice of examining an object in a way that the object's usefulness is not adversely affected. Different types of NDE methods exist but this thesis is based on microwave and millimeter wave NDE using imaging techniques. Microwave NDE is based on illuminating the object under test with a microwave signal and studying the various properties of the reflected signal from the object. This reflected signal contains some information about the inner structure of the object under test. This information may be contained in several parameters including the phase and magnitude of the reflected signal. The goal of this project is to design and build a Q-band coherent transceiver that is capable of measuring the reflected signal's phase and magnitude so that an image of the object under test may be reconstructed. From the several techniques that can be used to construct an image of the object under test, techniques of interest to this work include synthetic aperture focusing technique (SAFT) and microwave holography. The transceiver system should have the ability to sweep a large portion of Q-band frequency range in small frequency steps as quick as possible while the detected phase and magnitude of the reflected signal is very accurate. Several different designs were studied and the final schematic diagram of the transceiver system was determined. One of the most important modules that was designed, implemented and tested in the laboratory was an accurate phase/magnitude detector circuit. The compared results of the scans using the transceiver system and vector network analyzer (VNA) showed that this transceiver system has a great potential to replace a VNA for the purpose of microwave and millimeter wave imaging.

Beni, Aman Aflaki↗

Progress on a Multichannel, Dual-Mixer Stability Analyzer

Several documents describe aspects of the continuing development of a multichannel, dual-mixer system for simultaneous characterization of the instabilities of multiple precise, low-noise oscillators. One of the oscillators would be deemed to be a reference oscillator, its frequency would be offset by an amount (100 Hz) much greater than the desired data rate, and each of the other oscillators would be compared with the frequency-offset signal by operation of a combination of hardware and software. A high-rate time-tag counter would collect zero-crossing times of the approximately equal 100-Hz beat notes. The system would effect a combination of interpolation and averaging to process the time tags into low-rate phase residuals at the desired grid times. Circuitry that has been developed since the cited prior article includes an eight-channel timer board to replace an obsolete commercial time-tag counter, plus a custom offset generator, cleanup loop, distribution amplifier, zero-crossing detector, and frequency divider.

Kirk, Albert↗

Experiments with phase transitions at very high pressure

A diamond anvil cell is described which was developed for studying hydrogen and other materials to pressure above 100 PGa, including measurements at low temperature. The benefits of X-ray diffraction using synchrotron radiation and using a fixed anode source are examined as well as the optimization of X-ray diffraction at low temperature. A Ge diode detector was incorporated into apparatus for measuring optical absorption, reflectance, and fluorescence in order to enable luminescence studies and Raman spectra were obtained. Results of experiments on Si, Ge, GaP, InAs, hydrogen, benzene, nitrogen, graphite, and the superconductor CeCu2Si2 are given.

Spain, I. L.↗

Atomic Force Microscope Mediated Chromatography

The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a sliding plate system, consisting of two flat surfaces, one of which has a recessed channel. A fluid flow is produced by axially sliding one plate past another, where the fluid has mechanical shear forces imposed at each point along the channel length. The shear-induced flow rates are very reproducible, and do not have pressure or voltage gradient limitations. SDC opens up a new range of enhanced separation kinetics by permitting the sample confinement with submicron dimensions. Small, highly confined liquid is advantageous for chromatographic separation because the separation rate is known to scale according to the square of the confined sample diameter. In addition, because shear-driven flows are not limited by fluid velocity, shear-driven liquid chromatography may provide up to 100,000 plate efficiency.

Anderson, Mark S.↗