Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Beam test results of the Intermediate Silicon Tracker for sPHENIX

The Intermediate Silicon Tracker (INTT), a two-layer barrel silicon strip tracker, is a key component of the tracking system for sPHENIX at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The INTT is designed to enable the association of reconstructed tracks with individual RHIC bunch crossings. To evaluate the performance of preproduction INTT ladders and the readout chain, a beam test was conducted at the Research Center for Accelerator and Radioisotope Science, Tohoku University, Japan. This paper presents the performance of the INTT evaluated through studies of the signal-to-noise ratio, residual distribution, spatial resolution, hit-detection efficiency, and multiple track reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Specimen Size and Geometry Effects on the Master Curve Fracture Toughness Measurements of EUROFER97 and F82H Steels

EUROFER97 and F82H are two leading reduced-activation ferritic-martensitic (RAFM) steels for fusion blanket applications. Exposure to the harsh environment of fusion reactors can result in severe degradation of materials fracture toughness (FT). Thus, the post-irradiation evaluation of FT is critical to understanding the material behavior. Due to the space constraint of irradiation facilities, the development of small specimen test techniques (SSTT) is necessary to evaluate the performance of irradiated materials. In this study, we evaluated the specimen size and geometry effects on the ductile-to-brittle transition FT of EUROFER97 batch-3 and F82H-BA12 steels. The specimen thicknesses ranged from 1.65 to 12.7 mm and the geometries included 1.65 mm bend bar, 4 mm mini-compact tension (miniCT), and 0.5T compact tension (CT) specimens. Fracture toughness testing and evaluations were performed using the Master Curve method in the ASTM E1921-19 standard. After size correction to 1T size using the Master Curve method, no specimen size effect was observed between the 4 mm miniCT and 0.5T CT specimens for the Master Curve reference temperature T0Q, while the bend bars yielded a higher T0Q. A strong effect of fatigue precrack front straightness on T0Q for 0.5T CT specimens was observed. The minimum number of specimens needed for each specimen geometry has been determined.

Chen, Xiang↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently-prepared CST media batches (9120- B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant. Simulant batch contact equilibrium cesium loading results for the three CST batches (including two lots of one batch) are provided in Table ES-1. The 35 °C data indicates that the archived IE-911 batch has a higher cesium capacity than recently-prepared CST media and that the minor TCCR CST 9120-B media lot (2099000035) has similar cesium removal performance to the major TCCR lot (2099000034). Tests conducted at 25 ºC for the archived IE-911 CST batch indicated lower cesium removal performance with this simulant batch than was observed recently with a different SRS Average Simulant batch. A dilution factor (DF) is typically utilized when modeling engineered CST media cesium loading performance to account for mass contributions from the binder material. In cases where CST performance is lower than expected, this factor includes corrections for the binder and for low performance. The ZAM (Zheng, Anthony, and Miller) Isotherm Model DF values are provided in Table ES-1 for each simulant batch contact result. DF values near 0.5 were determined for the 9120-B and 9140-B CST batch contact tests while DF values near 0.6 (20% higher) were determined for the tests with IE-911. These dilution factors are lower than recently observed with a different SRS Average Simulant batch (9140-B DF = 0.68; IE-911 DF = 1.0). Based on these results, it appears that some component in the simulant solution used for equilibrium testing may have resulted in reduced cesium loading on the CST media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs- 137. The TCCR project is currently focused on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently prepared CST media batches (9120-B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

100% Carbon-Free Electricity for Sandia NM and KAFB Using Concentrating Solar Power (CSP) (SAND Report)

This report provides a design study to produce 100% carbon-free electricity for Sandia NM and Kirtland Air Force Base (KAFB) using concentrating solar power (CSP). Annual electricity requirements for both Sandia and KAFB are presented, along with specific load centers that consume a significant and continuous amount of energy. CSP plant designs of 50 MW and 100 MW are then discussed to meet the needs of Sandia NM and the combined electrical needs of both Sandia NM and KAFB. Probabilistic modeling is performed to evaluate inherent uncertainties in performance and cost parameters on total construction costs and the levelized cost of electricity. Total overnight construction costs are expected to range between ~$300M - $400M for the 50 MW CSP plant and between ~$500M - $800M for the 100 MW plant. Annual operations and maintenance (O&M) costs are estimated together with potential offsets in electrical costs and CO 2 emissions. Other considerations such as interconnections, land use and permitting, funding options, and potential agreements and partnerships with Public Service Company of New Mexico (PNM), Western Area Power Administration (WAPA), and other entities are also discussed.

14 SOLAR ENERGY↗

LBNL Fault Detection and Diagnostics Datasets

These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equipment (rooftop unit, single-duct air handler unit, dual-duct air handler unit, variable air volume box, fan coil unit, chiller plant, and boiler plant). Each dataset includes a .pdf file to document key information necessary to understand the content and scope, multiple csv files containing all the time-series data for faults at different severity levels and one fault-free case, and a ttl file to visualize the data according to BRICK schema. The dataset was created by LBNL, PNNL, NREL, ORNL and Drexel University.

AC↗

CSP Design Study for Sandia National Laboratories and Kirtland Air Force Base

This report provides a design study to produce 100% carbon-free electricity for Sandia NM and Kirtland Air Force Base (KAFB) using concentrating solar power (CSP). CSP plant designs of 50 MW and 100 MW are assessed to meet the electricity needs of Sandia NM and/or KAFB. Probabilistic modeling is performed to evaluate inherent uncertainties in performance and cost parameters on total construction costs and the levelized cost of electricity. Estimated annual electricity production was ~200 – 300 GWh for the 50 MW plant and ~400 – 700 GWh for the 100 MW plant. The overnight construction costs ranged between ~$300M - $400M for the 50 MW CSP plant and between ~$500M - $800M for the 100 MW CSP plant. The heliostat field was the most significant subsystem cost, followed by the thermal energy storage, power cycle, and fixed operation and maintenance costs. Other considerations such as land availability and permitting, funding options, and interconnections are discussed.

Ho, Clifford K.↗

Influence of Combustion Gas Temperatures on Piston Deposits for Diesel and Ammonia Dual-Fuel Combustion

As new fuels are adopted for marine engines, it is necessary to understand their impact on lubricant performance. In order to evaluate the performance of existing lubricants and inform the development of new ones, a deposit control test protocol has been developed using the ExxonMobil Enterprise two-stroke marine diesel research engine. Repeated tests at the target speed/load operating condition but different thermal conditions show that the temperature of the combustion gases is a key driver in the formation of deposits on piston surfaces, impacting both the quantity of deposits and whether they are hard or gummy. These impacts are examined for diesel combustion as well as ammonia dual-fuel combustion. Among alternative marine fuels, ammonia has perhaps the most unanswered questions regarding interactions with cylinder lubricants. The influence of ammonia dual-fuel combustion on the thermal conditions experienced by the lubricant are discussed. Scrape down oil samples were collected after operation with ammonia for analysis and comparison with fresh oil. Chemical analysis using a GC/MS instrument did not show significant permanent chemical changes in the lubricant due to ammonia exposure.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

Benchmark Analysis

Tremendous progress has been achieved in the development of land models and their inclusion in Earth system models (ESMs). However, we still have very limited knowledge on the performance skills of these land models. This chapter introduces benchmark analysis, which is a procedure to measure performance of models against a set of defined standards. The benchmark analysis includes: (1) defining targeted aspects of model performance to be evaluated; (2) testing model performance in comparison with a set of benchmarks; (3) measuring model performance skill through quantitative metrics; and (4) evaluating model performance and offering suggestions for future model improvement.

Luo, Yiqi↗

Evaluation of Electrodialysis Desalination Performance of Novel Bioinspired and Conventional Ion Exchange Membranes with Sodium Chloride Feed Solutions

Electrodialysis (ED) desalination performance of different conventional and laboratory-scale ion exchange membranes (IEMs) has been evaluated by many researchers, but most of these studies used their own sets of experimental parameters such as feed solution compositions and concentrations, superficial velocities of the process streams (diluate, concentrate, and electrode rinse), applied electrical voltages, and types of IEMs. Thus, direct comparison of ED desalination performance of different IEMs is virtually impossible. While the use of different conventional IEMs in ED has been reported, the use of bioinspired ion exchange membrane has not been reported yet. The goal of this study was to evaluate the ED desalination performance differences between novel laboratory‑scale bioinspired IEM and conventional IEMs by determining (i) limiting current density, (ii) current density, (iii) current efficiency, (iv) salinity reduction in diluate stream, (v) normalized specific energy consumption, and (vi) water flux by osmosis as a function of (a) initial concentration of NaCl feed solution (diluate and concentrate streams), (b) superficial velocity of feed solution, and (c) applied stack voltage per cell-pair of membranes. A laboratory‑scale single stage batch-recycle electrodialysis experimental apparatus was assembled with five cell‑pairs of IEMs with an active cross-sectional area of 7.84 cm2. In this study, seven combinations of IEMs (commercial and laboratory-made) were compared: (i) Neosepta AMX/CMX, (ii) PCA PCSA/PCSK, (iii) Fujifilm Type 1 AEM/CEM, (iv) SUEZ AR204SZRA/CR67HMR, (v) Ralex AMH-PES/CMH-PES, (vi) Neosepta AMX/Bare Polycarbonate membrane (Polycarb), and (vii) Neosepta AMX/Sandia novel bioinspired cation exchange membrane (SandiaCEM). ED desalination performance with the Sandia novel bioinspired cation exchange membrane (SandiaCEM) was found to be competitive with commercial Neosepta CMX cation exchange membrane.

42 ENGINEERING↗

Rancor-HUNTER: A Virtual Plant and Operator Environment for Predicting Human Performance

Advances in simulation capabilities to model physical systems have outpaced the development of simulations for humans using those physical systems. There is an argument that the infinite span of potential human behaviors inherently render human modeling more challenging than physical systems. Despite this challenge, the need for modeling humans interacting with these complex systems is paramount. As technologies have improved, many of the failure modes originating from the physical systems have been solved. This means the overall proportion of human errors has increased, such that it is not uncommon to be the primary driver of system failure in modern complex systems. Moreover, technologies such as automated systems may introduce emerging contexts that can cause new, unanticipated modes of human error. Therefore, it is now more important than ever to develop models of human behavior to realize overall system error reductions and achieve established safety margins. To support new and novel concepts of operations for the anticipated wave of advanced nuclear reactor deployments, human factors and human reliability analysis researchers need to develop advanced simulation-based approaches. This talk presents a simulation environment suitable to both collect data and then perform Monte Carlo simulations to evaluate human performance and develop better models of human behavior. Specifically, the Rancor Microworld Simulator models a complex energy production system in a simplified manner. Rancor includes computer-based procedures, which serve as a framework to automatically classify human behaviors without manual, subjective experimenter coding during scenarios. This method supports a detailed level of analysis at the task level. It is feasible for collecting large sample sizes required to develop quantitative modelling elements that have historically challenged traditional full-scope simulator study approaches. Additionally, the other portion of this experimental platform, the Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER), is presented to show how the collected data can be used to evaluate novel scenarios based on the contextual factors, or performance shaping factors, derived from Rancor simulations. Rancor-HUNTER is being used to predict operator performance with new procedures, such as results from control room modernization or new-build situations. Rancor-HUNTER is also proving a useful surrogate platform to model human performance for other complex systems.

99 GENERAL AND MISCELLANEOUS↗

ECAR-7210 Rev 0 Steady-state Thermo-mechanical Analysis of the MARVEL Fuel Bundle

This document reports the steady-state thermal-hydraulic and static mechanical analyses of the MARVEL micro-reactor core. The objective of this work is to investigate whether fuel-to-fuel contact could occur due to the thermal deformation of the fuel cladding during the normal operation and to assess the resulting impact on the peak cladding temperatures (PCT) if contact occurs. The scope of the work consists of three computational tasks. First, a conjugate heat transfer analysis using computational fluid dynamics (CFD) model was performed to evaluate the PCTs during normal operating conditions. Second, a finite element analysis (FEA) using the cladding temperature field obtained from the CFD analysis was performed to evaluate the thermal deformation of cladding and determine the occurrence of fuel-to-fuel contact. Finally, a CFD analysis of FEA-informed fuel-to-fuel gap (represented by a conservative 0.05 mm uniform gap) was performed to evaluate whether the PCT exceeds the safety criteria.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

54 ENVIRONMENTAL SCIENCES↗

Insights from Optimizing HPL Performance on Exascale Systems: A Comparative Analysis of Panel Factorization

High performance LINPACK (HPL) remains the primary benchmark for evaluating supercomputing performance. It includes many parts with substantial internal complexity, and its performance is affected by a large number of parameters that interact in ways that are difficult to predict on large-scale heterogeneous supercomputer systems. We present a comprehensive performance analysis of HPL on Frontier, the world’s first exascale supercomputer, which achieved HPL performance of 1.35 exaflops. Through empirical parameter tuning, detailed modeling, and comparative evaluation, we uncover critical performance insights, share lessons learned, and outline best practices for effective parameter tuning on exascale systems. We introduce and evaluate two novel PDFACT strategies: a dedicated-thread (DT) variant and a GPU-based variant (GPUPDFACT) implementation using HIP cooperative groups, demonstrating that GPU-based factorization outperforms conventional CPU-based PDFACT on Frontier’s architecture. Our findings establish key performance factors for HPL on exascale systems and offer valuable guidance for future high-performance computing and benchmarking efforts.

Lu, Hao [ORNL] (ORCID:000000018941870X)↗

Workflow for evaluating enzyme immobilization and performance for continuous flow manufacturing

Enzymes have shown promise in various industries due to their functional specificity, catalytic efficiency, and environmental sustainability. These biological catalysts can be a pivotal component of manufacturing pipelines like continuous flow chemistry. For this, there exists a need to robustly immobilize enzymes on solid supports and assess the effects of the solid supports on catalytic performance and stability. Here, we use an industrially relevant model enzyme, C. ensiformis (Jack bean) urease, to demonstrate immobilization and assess performance in the context of continuous flow manufacturing. Various immobilization strategies were screened focusing on immobilization efficiency, protocol simplicity, and urease biocatalyst kinetics. Based on this, CDI-agarose and NHS-agarose resins were identified as the best-performing immobilization strategies for urease. CDI-agarose-urease and NHS-agarose-urease were then scaled up and applied to a large-scale continuous flow reactor to evaluate product yields, operational stability, and long-term stability. These experiments identified differences in stability and performance depending on the immobilization method tested. This highlights the importance of screening immobilization methods and subsequent enzyme performance for each candidate biocatalyst used in manufacturing to promote optimal performance and stability. As such, this work provides a framework for evaluating enzyme biocatalyst immobilization approaches to improve performance and enable transition into industrial processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data for Multisite Field Evaluation of Oil Accumulation and Agronomic Performance in Grain and Sweet Sorghums Engineered for Lipid Hyperaccumulation

Oil sorghum (OS) has been developed by engineering grain (TX430) and sweet (Ramada) genetic backgrounds to accumulate triacylglycerols (TAG) in vegetative tissues as an energy-dense feedstock for sustainable aviation fuel (SAF) and other biofuels. This study evaluated two TX430 OS lines (TxHO-2, TxHO-3) and two Ramada OS lines (RmHO-1, RmHO-2) alongside wild-type (WT) lines in NE and IL over 2 years (2023–2024) to quantify genotype × environment effects on agronomic performance and TAG accumulation. Across four environments, TX430 OS lines showed average TAG concentrations of 15.0 g kg−1 in leaves and 12.8 g kg−1 in stems, approximately 19-fold higher than WT. Ramada OS lines accumulated 26.1 g kg−1 in leaves and 12.3 g kg−1 in stems, approximately 25-fold and 13-fold increases over WT, respectively. OS lines in TX430 exhibited an 18% reduction in biomass (8.4 vs. 9.9 Mg ha−1 for WT), while Ramada OS lines had similar WT biomass (18.3 vs. 19.9 Mg ha−1 for WT). Among TX430 OS lines, TxHO-2 achieved the highest TAG yield (190 kg ha−1), while RmHO-1 led the Ramada lines (335 kg ha−1) due to higher biomass and similar TAG concentration. Enhanced TAG accumulation increased N, P, and K removal in TX430 lines but not in Ramada lines. Structural carbohydrate and ash concentration were unaffected. Overall, results confirm vegetative lipid accumulation as a viable strategy for high-biomass sorghum, supporting its potential as a dual-purpose feedstock for SAF. Future work should focus on minimizing biomass yield penalties and improving nutrient use efficiency in oil sorghum systems.

Agronomy↗

$\mathrm{RADICAL}$-Pilot and $\mathrm{PMIx}$/$\mathrm{PRRTE}$: Executing Heterogeneous Workloads at Large Scale on Partitioned $\mathrm{HPC}$ Resources

Execution of heterogeneous workflows on high-performance computing (HPC) platforms present unprecedented resource management and execution coordination challenges for runtime systems. Task heterogeneity increases the complexity of resource and execution management, limiting the scalability and efficiency of workflow execution. Re-source partitioning and distribution of tasks execution over portioned re-sources promises to address those problems but we lack an experimental evaluation of its performance at scale. Here this paper provides a performance evaluation of the Process Management Interface for Exascale (PMIx) and its reference implementation PRRTE on the leadership-class HPC plat-form Summit, when integrated into a pilot-based runtime system called RADICAL-Pilot. We partition resources across multiple PRRTE Distributed Virtual Machine (DVM) environments, responsible for launching tasks via the PMIx interface. We experimentally measure the work-load execution performance in terms of task scheduling/launching rate and distribution of DVM task placement times, DVM startup and termination overheads on the Summit leadership-class HPC platform. Integrated solution with PMIx/PRRTE enables using an abstracted, standardized set of interfaces for orchestrating the launch process, dynamic process management and monitoring capabilities. It extends scaling capabilities allowing to overcome a limitation of other launching mechanisms (e.g., JSM/LSF). Explored different DVM setup configurations provide insights on DVM performance and a layout to leverage it. Our experimental results show that heterogeneous workload of 65,500 tasks on 2048 nodes, and partitioned across 32 DVMs, runs steady with resource utilization not lower than 52%. While having less concurrently executed tasks resource utilization is able to reach up to 85%, based on results of heterogeneous workload of 8200 tasks on 256 nodes and 2 DVMs.

97 MATHEMATICS AND COMPUTING↗

SoK: What does it Mean to Benchmark Database Forensics?

Relational Database Management Systems are the backbone of modern enterprises and public-sector services, and are thus frequent targets of security incidents, insider threats, and thorough regulatory audits. Consequently, databases have become key sources of digital evidence, requiring investigators to reconstruct past activity from audit logs, transaction logs, and backups. Although benchmarking frameworks such as those developed by the Transaction Processing Performance Council (TPC) are widely used to evaluate database performance, they do not capture forensic requirements such as evidentiary completeness, tamper-evidence, chain of custody, or regulatory compliance under GDPR and CCPA. This survey examines the emerging domain of forensic database benchmarking. We gathered prior research on database forensics, secure logging, and tamper-evident data structures; we analyze modern forensic-ready features in commercial and open-source systems (SQL Server Ledger, Oracle Blockchain Tables, PostgreSQL pgAudit, Db2 Audit, Aurora Database Activity Streams, Oracle Real Application Security and IBM Guardium) and assess why existing benchmarks are insufficient. We propose forensic workloads, metrics, and methodologies that incorporate adversarial stressors, deleted-record recovery, and backup analysis. We also identify open research problems and call for a community-driven forensic benchmark suite. The result is an idea for evaluating not only database performance but also forensic soundness, bridging the gap between system engineering, compliance, and digital investigations.

Lenard, Ben↗