A Visualization System for Performance Analysis of Image Classification Models
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Marine and hydrokinetic (MHK) energy, including ocean waves, tidal current, ocean current and river current, has been recognized as a promising power source due to its full-day availability and high energy potential. At this stage, ocean current energy, tidal energy and ocean wave energy are currently the most competitive sourves among all the categories of MHK. The state of art MHK energy harvesting technology mainly focus on harvesting either ocean wave energy or current energy, but not both. However, a significant amount of ocean waves and tidal/ ocean current coexist in many sites and traditional devices that harvest from a single form of MHK energy, cannot make full use of the coexisting ocean energy. Furthermore, MHK energy harvesting devices need to advance to be cost-effective and competitive with other energy sources. This is difficult to achieve. Ocean wave excitation is irregular, which means that ocean wave height and wave periods are unpredictable and excitation forces on energy harvesting devices can have large variance in amplitude and frequency. Such problems/ restrictions can be possibly addressed by the concept of a hybrid energy converter. In this sense, a hybrid wave-current ocean energy conveter (HWCEC) that simutaneously harvests energy from current and wave with one single power takeoff (PTO) is designed.The wave energy is extracted through relative heaving motion between a floating buoy and a submerged second body, while the current energy is extracted using a marine current turbine (MCT). Energy from both sources are integrated by a hybrid PTO whose concept is based on a mechanical motion rectifier (MMR). In this study, different working modes are investigated together with switching criteria.Simulations were conducted with hydrodynamic coefficients obtained from computational fluid dynamics analysis and boundary element method. Tank tests were conducted for a HWCEC under coexisting wave and current inputs. For comparison, separate baseline tests of a turbine and a two-body point absorber, each acting in isolation, are conducted. Experimental results validate the dynamic modeling and show that a HWCEC can increase the output power with a range between 29-87 percent over either current turbine and wave energy converter acting individually, and it can reduce by up to 70 percent the peak-to-average power ratio compared with the wave energy converter on the tested conditions.Such results demonstrate the potential of the HWCEC as an efficient and cost-effective design.
Explore the source record for details and available documents.
To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy's Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.
To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy’s Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In this article, the performance analysis of a 22.5% efficient polysilicon on silicon oxide (poly-Si/SiOx) passivated contact solar cells with deliberately introduced pinholes using metal-assisted chemical etching (MACE) has been performed with the help of optical analysis using Sunsolve and electrical analysis using Quokka3. The power loss is maximum due to recombination and resistive losses in the bulk (~0.76 mW/cm2 ) followed by power loss due to rear contact recombination (~0.35 mW/cm2 ). Recombination at the front surface also contributes to 0.24 mW/cm2. The effect of improving the bulk lifetime and lowering the recombination current density at the rear side on Voc, FF and efficiency has been investigated.
Performance analysis of double-reflector system for collecting solar energy - applicability to solar Brayton cycle power system
Abstract not provided.
Benchmark Study conducted focusing on CPU and program performance analysis. Performance data gathered using 2 different programs and comparisons made based on performance. After comparisons are made, conclusions can be drawn and improvements are made upon hardware and software.
The solar facility located at a custom photo laboratory in Mill Valley, California is described. It was designed to provide 59 percent of the hot water requirements for developing photographic film and domestic hot water use. The design load is to provide 6 gallons of hot water per minute for 8 hours per working day at 100 F. It has 640 square feet of flat plate collectors and 360 gallons of hot water storage. The auxillary back up system is a conventional gas-fired water heater. Site and building description, subsystem description, as-built drawings, cost breakdown and analysis, performance analysis, lessons learned, and the operation and maintenance manual are presented.
Call graph or caller-callee relationships have been used for various kinds of static program analysis, performance analysis and profiling, and for program safety or security analysis such as detecting anomalies of program execution or code injection attacks. However, different tools generate call graphs in different formats, which prevents efficient reuse of call graph results. In this paper, we present an approach of using ontology and resource description framework (RDF) to create knowledge graphs for specifying call graphs to facilitate the construction of full-fledged and complex call graphs of computer programs, realizing more interoperable and scalable program analyses than conventional approaches. We create a formal ontology-based specification of call graph information to capture concepts and properties of both static and dynamic call graphs so different tools can collaboratively contribute to more comprehensive analysis results. Our experiments show that ontology enables merging of call graphs generated from different tools and flexible queries using a standard query interface. Index Terms—Callgraph, ontology, knowl