Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The ERTS wideband image communication system.

The ERTS payload includes a three camera return beam vidicon (RBV) television system and a four channel multispectral scanner system (MSS). The communications system described includes spacecraft wideband equipment plus unique payload processing equipment located at three NASA tracking stations. The RBV information, transmitted as analog FM with a baseband response of dc to 3.2 MHz, is telemetered, processed and recorded on a wideband video recorder. The MSS data, consisting of 24 analog sensor outputs, is digitized and encoded as 15 megabit per second PCM. The MSS data is then transmitted as analog FM, demultiplexed, and recorded on a 25 channel recorder. It is shown that bit error rate is an excellent indicator of MSS link performance while signal-to-noise ratio and distortion vs frequency adequately define RBV link performance.

Pandelides, J.↗

An analysis of the AVE-SESAME I period using statistical structure and correlation functions

Structure and correlation functions are used to describe atmospheric variability during the 10-11 April day of AVE-SESAME 1979 that coincided with the Red River Valley tornado outbreak. The special mesoscale rawinsonde data are employed in calculations involving temperature, geopotential height, horizontal wind speed and mixing ratio. Functional analyses are performed in both the lower and upper troposphere for the composite 24 h experiment period and at individual 3 h observation times. Results show that mesoscale features are prominent during the composite period. Fields of mixing ratio and horizontal wind speed exhibit the greatest amounts of small-scale variance, whereas temperature and geopotential height contain the least. Results for the nine individual times show that small-scale variance is greatest during the convective outbreak. The functions also are used to estimate random errors in the rawinsonde data. Finally, sensitivity analyses are presented to quantify confidence limits of the structure functions.

Fuelberg, H. E.↗

Performance of a High-solidity High-pressure-ratio Transonic Rotor

A high-solidity low-aspect-ratio transonic rotor with an inlet hub-tip ratio of 0.52 was investigated experimentally. The rotor developed a total-pressure tatio of 1.93 and an efficiency of 92 percent at an equivalent wheel tip speed of 1036 feet per second. The feasibility of using this rotor as a component of an inlet stage of an axial-flow compressor was investigated.

Neumann, Harvey E↗

Investigation of Turbines Suitable for Use in a Turbojet Engine Wtih High Compressor Pressure Ratio and Low Compressor-tip Speed V : Experimental Performance of Two-stage Turbine with Downstream Stator

An experimental investigation of a highly loaded two-stage turbine with a downstream stator revealed that (1) at equivalent design work and speed the brake internal efficiency was 0.81 and the maximum efficiency obtained was 0.85, and (2) the downstream stator left very little energy in the form of tangential velocity in the gas and, in general, performed well with 0.78 recovery being obtained at equivalent design work and speed.

Davison, Elmer H↗

Investigation of Turbines Suitable for Use in a Turbojet Engine with High Compressor Pressure Ratio and Low Compressor-tip Speed VI: Experimental Performance of Two-stage Turbine

The brake internal efficiency of the highly loaded two-stage turbine was 0.79 equivalent design work and speed. The maximum brake internal efficiency was 0.84. A radial survey revealed these major defects: (1) the first-rotor throat area was too large, and a large area of underturned flow existed near the tip;(2) considerable underturning existed at the second-stator outlet; and (3) tangential components of velocity at the turbine outlet amounted to 2.5 points in turbine efficiency.

Davison, Elmer H↗

Investigation of Turbines Suitable for Use in a Turbojet Engine with High Compressor Pressure Ratio and Low Compressor-tip Speed VII : Experimental Performance of Modified Two-stage Turbine

Modifying the original turbine by closing down the first-rotor throat area and shrouding the first and second rotors resulted in an over-all increase in in efficiency of 3.5 percentage points. At equivalent design work and speed the rating and aerodynamic efficiences of the modified turbine were 0.825 and 0.846, respectively. The maximum rating and erodynamic efficiencies were 0.875 and 0.906, respectively. A radial survey indicated improved firstively. A radial survey indicated improved first and second-stage efficiencies but showed that the effective throat areas of the second stator and rotor were too large.

Davison, Elmer H↗

Performance and optimization of a combustion interface for isotope ratio monitoring gas chromatography/mass spectrometry

Conditions and systems for on-line combustion of effluents from capillary gas chromatographic columns and for removal of water vapor from product streams were tested. Organic carbon in gas chromatographic peaks 15 s wide and containing up to 30 nanomoles of carbon was quantitatively converted to CO2 by tubular combustion reactors, 200 x 0.5 mm, packed with CuO or NiO. No auxiliary source of O2 was required because oxygen was supplied by metal oxides. Spontaneous degradation of CuO limited the life of CuO reactors at T > 850 degrees C. Since NiO does not spontaneously degrade, its use might be favored, but Ni-bound carbon phases form and lead to inaccurate isotopic results at T < 1050 degrees C if gas-phase O2 is not added. For all compounds tested except CH4, equivalent isotopic results are provided by CuO at 850 degrees C, NiO + O2 (gas-phase mole fraction, 10(-3)) at 1050 degrees C and NiO at 1150 degrees C. The combustion interface did not contribute additional analytical uncertainty, thus observed standard deviations of 13C/12C ratios were within a factor of 2 of shot-noise limits. For combustion and isotopic analyses of CH4, in which quantitative combustion required T approximately 950 degrees C, NiO-based systems are preferred, and precision is approximately 2 times lower than that observed for other analytes. Water must be removed from the gas stream transmitted to the mass spectrometer or else protonation of CO2 will lead to inaccuracy in isotopic analyses. Although thresholds for this effect vary between mass spectrometers, differential permeation of H2O through Nafion tubing was effective in both cases tested, but the required length of the Nafion membrane was 4 times greater for the more sensitive mass spectrometer.

NASA Discipline Exobiology↗

Production of Energy Efficient Preform Structures (PEEPS)

Due to its low density, good structural characteristics, excellent fabrication properties, and attractive appearance, aluminum metal and its alloys continue to be widely utilized. The transportation industry continues to be the largest consumer of aluminum products, with aerospace as the principal driver for this use. Boeing has long been the largest single company consumer of heat-treated aluminum in the U.S. The extensive use of aluminum to build aircraft and launch vehicles has been sustained, despite the growing reliance on more structurally efficient carbon fiber reinforced composite materials. The trend in the aerospace industry over the past several decades has been to rely extensively on large, complex, thin-walled, monolithic machined structural components, which are fabricated from heavy billets and thick plate using high speed machining. The use of these high buy-to-fly ratio starting product forms, while currently cost effective, is energy inefficient, with a high environmental impact. The widespread implementation of Solid State Joining (SSJ) technologies, to produce lower buy-to-fly ratio starting forms, tailored to each specific application, offers the potential for a more sustainable manufacturing strategy, which would consume less energy, require less material, and reduce material and manufacturing costs. One objective of this project was to project the energy benefits of using SSJ techniques to produce high-performance aluminum structures if implemented in the production of the world fleet of commercial aircraft. A further objective was to produce an energy consumption prediction model, capable of calculating the total energy consumption, solid waste burden, acidification potential, and CO2 burden in producing a starting product form - whether by conventional or SSJ processes - and machining that to a final part configuration. The model needed to be capable of computing and comparing, on an individual part/geometry basis, multiple possible manufacturing pathways, to identify the best balance of energy consumption and environmental impact. This model has been created and populated with energy consumption data for individual SSJ processes and process platforms. Technology feasibility cases studies were executed, to validate the model, and confirm the ability to create lower buy-to-fly ratio performs and machine these to final configuration aircraft components. This model can now be used as a tool to select manufacturing pathways that offer significant energy savings and, when coupled with a cost model, drive implementation of the SSJ processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Examining Effects of Negative to Positive Capacity Ratio in Three-Electrode Lithium-Ion Cells with Layered Oxide Cathode and Si Anode

The negative to positive electrode capacity ratio (N:P) is crucial for lithium-ion cell design because it affects both energy density and long-term performance. Here, the effect of N:P ratio on electrochemical performance has been investigated for NMC 532 /Si cells containing a reference electrode. By monitoring individual electrode potentials, depths of lithiation/delithiation at the anode and cathode could be determined. The superior performance of the higher N:P cell, including greater reversibility, better capacity retention and lower impedance rise, can be attributed to smaller volume changes in the silicon particles during electrochemical cycling.

25 ENERGY STORAGE↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Sample Results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub- Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sample results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub-Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D (Cs) ) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of a 0.6 hub-tip radius-ratio transonic turbine designed for secondary-flow study I : design and experimental performance of standard turbine

Detailed design information including overall performance parameters, velocity diagrams, and blade surface velocities is presented. Experimental performance includes maps based on rating as well as total-pressure ratios showing the effect of exit whirl. Also included are results of surveys at the stator exit and downstream of the rotor at design speed and specific work. This information will be used as a standard for comparison with subsequent secondary-flow work.

Rohlik, Harold E↗

Numerical study of film cooling with internal coolant cross-flow effects - 18569

In the present study, the influence of coolant supply condition was investigated, the coolant supply at the hole entrance were considered to be either a plenum condition or a coolant cross-flow condition. The results indicated that at low blowing ratio M=0.5, the coolant supply channel structure has little effect on film cooling performance, however, at high blowing ratio M=1.0, the adiabatic wall film cooling effectiveness was significantly different between the plenum case and the cross-flow cases. In general, for the plenum condition, film cooling is better at M=0.5 than M=1.0, while for the cross-flow condition, the film cooling effectiveness is better at blowing ratio M=0.5 in the near hole region, while at further downstream region, the film cooling effectiveness is better at M=1.0. (authors)

42 ENGINEERING↗