Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Day-ahead continuous double auction-based peer-to-peer energy trading platform incorporating trading losses and network utilisation fee

Integration of distributed energy resources, such as photovoltaic solar (PV), introduces new opportunities to establish local energy market frameworks to improve renewable energy utilisation in residential sectors. Such peer-to-peer (P2P) energy trading refers to a local market structure where customers (and prosumers) interact to share excess PV generation to enhance the individual and community social welfare. In this work, a day-ahead continuous double auction (CDA)-based P2P market structure considering network losses and network utilisation fees was designed. Day-ahead PV energy is modelled using fractional integral polynomials and the output is forecasted using an autoregressive integrated moving average model for each market interval. Based on the customer load and excess PV energy, the CDA market is cleared using a bid/ask matching mechanism. The performance of the P2P market was evaluated by computing different welfare metrics while analysing the effect of network constraints. The results show that the designed CDA-based P2P market structure increases the social welfare of all participants by an average of 17.75% compared to the baseline for the presented cases. Moreover, the impact of the forecasting error between the day-ahead and real-time market was also quantified.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Iquitos Solar Energy Integration Study

The National Renewable Energy Laboratory performed an evaluation of the technical and economic feasibility of incorporating solar photovoltaic (PV) resources into the Iquitos, Peru power system at the request of Peru's Ministerio de Energia y Minas (MINEM). The Iquitos power system is electrically islanded due to its remote location; heavy fuel oil is used to generate electricity in the system leading to high electricity generation costs from high fuel prices. Solar PV has the potential to provide locally derived energy to ensure a reliable, affordable, and equitable power grid for the Iquitos region.

14 SOLAR ENERGY↗

Reliability and Power Degradation Rates of PERC Modules Using Differentiated Packaging Strategies and Characterization Tools

The reliability, durability and lifetime performance of passivated emitter, rear cell (PERC) modules used in real-world PV power plants is a critical challenge underlying the rapid adoption and bankability of these PERC cells, whose high efficiency help reduce the levelized cost of electricity (LCOE). We propose a degradation-science study of PERC module degradation pathways, benchmarking them relative to known degradation mechanisms and pathways of the incumbent aluminum back surface field (Al-BSF) modules exposed to real-world and accelerated exposure conditions.

14 SOLAR ENERGY↗

2024 Photovoltaic Inverter Reliability Workshop Summary Report & Proceedings

The National Renewable Energy Laboratory (NREL) organized the 2024 Photovoltaic Inverter Reliability Workshop on April 11-12, 2024, hosted at NREL's South Table Mountain campus in Golden, Colorado. The workshop was organized around seven key topics, including the present state of inverter reliability; solutions for reliability challenges; life cycle cost and ownership issues; testing, standards, performance, and reliability metrics; data reporting, analytics, and sharing; and the future of PV inverter reliability research. Participants included inverter manufacturers, national laboratory researchers, academics, independent testing laboratories, and more. Over the course of the two-day workshop, attendees arrived at several key priorities and conclusions. This report summarizes these conclusions and then collects presentations from the workshop into a record of the workshop's proceedings.

14 SOLAR ENERGY↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A mosaic infrared sensor for space astronomy

The objectives were to give a theoretical and/or experimental evaluation of HgCdTe detector arrays (1 to 5 micron) for space astronomy applications; to analyze low background HgCdTe/CCD coupling schemes for low temperature space astronomy; and to test and evaluate existing silicon CCDs at temperatures below 77 K. The accomplishments are the theoretical tradeoffs for PV-HgCdTe detectors completed at low temperatures; the characterization of existing PV-HgCdTe detector arrays (1 to 5 Micron) at low temperatures (low temperature performance exceeds measurement capability, preamplifier designed and built, and limiting detector current mechanisms analyzed); various detector/CCD coupling approaches were evaluated (resettable gate coupled approach chosen for low background); and low temperature CCD performance at 50 K shows compatibility with astronomical requirements.

Sood, Ashok K.↗

Analysis of the Latitudinal Variability of Tropospheric Ozone in the Arctic Using the Large Number of Aircraft and Ozonesonde Observations in Early Summer 2008

The goals of the paper are to: (1) present tropospheric ozone (O3) climatologies in summer 2008 based on a large amount of measurements, during the International Polar Year when the Polar Study using Aircraft, Remote Sensing, Surface Measurements, and Models of Climate Chemistry, Aerosols, and Transport (POLARCAT) campaigns were conducted (2) investigate the processes that determine O3 concentrations in two different regions (Canada and Greenland) that were thoroughly studied using measurements from 3 aircraft and 7 ozonesonde stations. This paper provides an integrated analysis of these observations and the discussion of the latitudinal and vertical variability of tropospheric ozone north of 55oN during this period is performed using a regional model (WFR-Chem). Ozone, CO and potential vorticity (PV) distributions are extracted from the simulation at the measurement locations. The model is able to reproduce the O3 latitudinal and vertical variability but a negative O3 bias of 6-15 ppbv is found in the free troposphere over 4 km, especially over Canada. Ozone average concentrations are of the order of 65 ppbv at altitudes above 4 km both over Canada and Greenland, while they are less than 50 ppbv in the lower troposphere. The relative influence of stratosphere-troposphere exchange (STE) and of ozone production related to the local biomass burning (BB) emissions is discussed using differences between average values of O3, CO and PV for Southern and Northern Canada or Greenland and two vertical ranges in the troposphere: 0-4 km and 4-8 km. For Canada, the model CO distribution and the weak correlation ( 30) of O3 and PV suggests that stratosphere-troposphere exchange (STE) is not the major contribution to average tropospheric ozone at latitudes less than 70oN, due to the fact that local biomass burning (BB) emissions were significant during the 2008 summer period. Conversely over Greenland, significant STE is found according to the better O3 versus PV correlation ( 40) and the higher 75th PV percentile. A weak negative latitudinal summer ozone gradient -6 to -8 ppbv is found over Canada in the mid troposphere between 4 and 8 km. This is attributed to an efficient O3 photochemical production due to the BB emissions at latitudes less than 65oN, while STE contribution is more homogeneous in the latitude range 55oN to 70oN. A positive ozone latitudinal gradient of 12 ppbv is observed in the same altitude range over Greenland not because of an increasing latitudinal influence of STE, but because of different long range transport from multiple mid-latitude sources (North America, Europe and even Asia for latitudes higher than 77oN).

climatologies↗

Understanding and Overcoming Water-induced Interfacial Degradation in Si Modules (Final Technical Report)

Moisture ingress is an established issue for photovoltaic module durability. Durability studies probing moisture effects typically evaluate performance losses at the module level, attributing global power losses to the overall humidity condition of the test environment while leaving local module behavior unknown. This project successfully develops an in situ short-wave infrared probe of moisture content in PV modules with demonstrated detection limits better than 100 ppm in EVA-encapsulated Al-BSF and PERC architectures (66 µg/cm3) and applicability across the range of terrestrial conditions. Combining this optical moisture quantification method (water reflectometry detection, WaRD) with peel testing of interfaces, biased photoluminescence imaging of performance, and first principles computation, we correlate module moisture content and cell performance over the course of accelerated damp heat tests. By performing multi-level humidity and thermal accelerated testing over thousands of hours (0, 65 and 85% RH and 25, 65, and 85°C), we are able to attribute effects of individual environmental stresses and the dependence on module architecture. Using first-principles computational chemistry, we find that the decomposition of EVA to acetic acid (Norrish II) is thermodynamically preferred over a pathway to acetaldehyde (Norrish I), elucidating the underlying chemistry of encapsulant degradation. We also find it is likely that water segregates to the stable interfaces of the cell, especially the SiNx/EVA interface. We find that moisture is strongly correlated with reduction in adhesion at the interfaces of the cells, particularly at Ag fingers. We show uniquely that the peel strength required to delaminate the encapsulant from the front of the cell depends not only on the exposure to a high heat and humid environment, but also to the moisture content during the mechanical testing, indicating an important interaction between when mechanical stresses are faced in terms of the moisture content of the module and its durability. We find that the background sheet resistance (that is, the sheet resistance rise not attributable to finger interruptions or cracks) is substantially higher in the backsheet mini-modules vs glass-glass packages when humidity and temperature are faced. This increase in power loss due to the background resistance increase over time in damp heat in glass-backsheet modules resulted in ~3-4% larger decrease in relative PCE compared to glass-glass modules. In glass-backsheet modules, the effect of the moisture dose alone is comparable or greater than that of the combined temperature and water term, suggesting that glass-backsheet modules are overall more susceptible to moisture induced performance loss. Finally, we show that thin film PV modules are amenable to WaRD measurement, based on the ability to detect moisture in POE encapsulants or in the cell stack itself. The ease of WaRD measurement and its few requirements on the bill of materials should enable broad applicability of this technique for studying the effects of moisture in PV.

14 SOLAR ENERGY↗

Smart Charging for Electric Ride-Hailing Vehicles using Renewables: A San Francisco Case Study

Charging large fleets of electric ride-hailing vehicles (ERVs) is a complex matter that could serve different objectives: lower carbon dioxide emissions, lower monetary expenditures, or maximize solar photovoltaics (PV) energy consumption. Currently, it is unclear how each of those objectives could impact the business and performance of a ride-hailing fleet. In order to fill this gap, this article employs a dynamic transportation model: a smart charging simulation that combines agent-based, discrete-event, and system dynamic modelling by comparing the above-mentioned objectives in separate scenarios. The results show that each scenario successfully manages to shift between 34% and 87% of all load to hours of the day when the objectives of those scenarios are met. Therefore, in comparison to the baseline, smart charging can save between 5% and 26% of monthly emissions and between 4% and 57% of monthly expenditures. The solar PV scenario, however, results in the highest savings, while ensuring profitable economics via net metering in the short- as well as long term. Finally, the sensitivity analysis points to important trade-offs between several fleet performance metrics. The article concludes by giving business and policy recommendations for maximising the economic, energy and environmental efficiency of large ERV fleets.

ADVANCED PROPULSION SYSTEMS,SOLAR ENERGY↗

Re-Designing the CSP Thermal Energy Storage System to Enable Higher-Temperature Performance at Reduced Cost (Final Technical Report)

Current commercial concentrating solar power (CSP) plants distinguish themselves from ordinary photovoltaic (PV) power plants by storing enough collected energy to enable generation for several hours after the sun goes down. CSP plants store this energy in the sensible heat of nitrate salts in large metallic storage tanks. Stainless-steel AISI 347H (SS347H) is needed for the hot tank operating at about 565 degrees C whereas carbon steel is sufficient for the cold-tank materials. Two-tank nitrate-salt thermal energy storage (TES) is presently in use in several trough-based CSP plants in Europe and in the U.S., operating up to about 390 degrees C. Three commercially operating tower-based CSP plants - Gemasolar in Spain, Crescent Dunes in Nevada, and Noor III in Morocco - use the same approach, storing nitrate salts at temperatures up to 580 degrees C. SS347H is many times more expensive than carbon steel and constitutes a significant cost element in today's CSP plants. Hence, CSP developers need to close the cost gap with PV-based solar plants by making cost reductions in every system of the plant. Redesigning the TES tanks is one opportunity for cost reduction.

14 SOLAR ENERGY↗

Protoflight photovoltaic power module system-level tests in the space power facility

Work Package Four, which includes the NASA-Lewis and Rocketdyne, has selected an approach for the Space Station Freedom Photovoltaic (PV) Power Module flight certification that combines system level qualification and acceptance testing in the thermal vacuum environment: The protoflight vehicle approach. This approach maximizes ground test verification to assure system level performance and to minimize risk of on-orbit failures. The preliminary plans for system level thermal vacuum environmental testing of the protoflight PV Power Module in the NASA-Lewis Space Power Facility (SPF), are addressed. Details of the facility modifications to refurbish SPF, after 13 years of downtime, are briefly discussed. The results of an evaluation of the effectiveness of system level environmental testing in screening out incipient part and workmanship defects and unique failure modes are discussed. Preliminary test objectives, test hardware configurations, test support equipment, and operations are presented.

Rivera, Juan C.↗

Protoflight photovoltaic power module system-level tests in the Space Power Facility

Work Package Four, which includes the NASA-Lewis and Rocketdyne, has selected an approach for the Space Station Freedom Photovoltaic (PV) Power Module flight certification that combines system level qualification and acceptance testing in the thermal vacuum environment: the 'protoflight' vehicle approach. This approach maximizes ground test verification to assure system level performance and to minimize risk of on-orbit failures. The preliminary plans for system level thermal vacuum environmental testing of the protoflight PV Power Module in the NASA-Lewis Space Power Facility (SPF) are addressed. Details of the facility modifications to refurbish SPF, after 13 years of downtime, are briefly discussed. The results of an evaluation of the effectiveness of system level environmental testing in screening out incipient part and workmanship defects and unique failure modes are discussed. Preliminary test objectives, test hardware configurations, test support equipment, and operations, are presented.

Rivera, Juan C.↗

NASA Glenn Research Center Solar Cell Experiment Onboard the International Space Station

Accurate air mass zero (AM0) measurement is essential for the evaluation of new photovoltaic (PV) technology for space solar cells. The NASA Glenn Research Center (GRC) has flown an experiment designed to measure the electrical performance of several solar cells onboard NASA Goddard Space Flight Center's (GSFC) Robotic Refueling Missions (RRM) Task Board 4 (TB4) on the exterior of the International Space Station (ISS). Four industry and government partners provided advanced PV devices for measurement and orbital environment testing. The experiment was positioned on the exterior of the station for approximately eight months, and was completely self-contained, providing its own power and internal data storage. Several new cell technologies including four-junction (4J) Inverted Metamorphic Multi-junction (IMM) cells were evaluated and the results will be compared to ground-based measurement methods.

Solar Cell Calibration Facility↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

Further Analyses of the NASA Glenn Research Center Solar Cell and Photovoltaic Materials Experiment Onboard the International Space Station

Accurate air mass zero (AM0) measurement is essential for the evaluation of new photovoltaic (PV) technology for space solar cells. The NASA Glenn Research Center (GRC) has flown an experiment designed to measure the electrical performance of several solar cells onboard NASA Goddard Space Flight Center's (GSFC) Robotic Refueling Mission's (RRM) Task Board 4 (TB4) on the exterior of the International Space Station (ISS). Four industry and government partners provided advanced PV devices for measurement and orbital environment testing. The experiment was positioned on the exterior of the station for approximately eight months, and was completely self-contained, providing its own power and internal data storage. Several new cell technologies including four-junction (4J) Inverted Metamorphic Multi-Junction (IMM) cells were evaluated and the results will be compared to ground-based measurement methods.

multi-junction↗

Photovoltaic module antireflection coating degradation survey using color microscopy and spectral reflectance

Abstract Commercial antireflective coatings (ARCs) on photovoltaic (PV) module glass can improve module power by 2.5%–3.0%, but their long‐term field performance requires additional study. In this paper, we investigate ARC performance on fielded modules using two nondestructive techniques: reflectance spectroscopy and RGB microscopy, finding a large variation in coating durability and performance. For new coatings, the fleet average nominal power enhancement is 2.8%. This power enhancement is observed to degrade at approximately −0.05%/year absolute over the first 8 years of fielding in arrays that are not regularly cleaned. Interferometry and imaging results imply that coating loss for these modules is due to slow chemical thinning of the initial 125 nm thick coating by 1.4 to 5.0 nm/year. Due to the physics of interference coatings, the performance loss is projected to accelerate as the coating is further thinned, resulting in a coating lifetime (time to 80% of initial performance) of 7.5 to 25 years. At the higher 5.0 nm/year coating loss rates, we estimate that −0.14%/year power degradation of the module can be attributed solely to ARC degradation over the first 20 years. Extreme coating loss is observed on some modules where after 8 years fielding, the coating can be completely removed with a single wet wipe with a lens tissue. A case study is also presented comparing ARC and noncoated modules installed at a single site in 2013. We find that the ARC modules have a 2.6% higher soiling power loss than the noncoated modules; this exceeds the ARC power enhancement of 2.4% and leads to the surprising conclusion that the ARC lowers production for modules in this location due to increased soiling. These results demonstrate that RGB microscopy is a powerful, field‐capable, and quantitative characterization technique for assessing degradation of PV module ARCs.

Karin, Todd↗

Customized open source renewable energy models validated through PHIL lab experiments

Energy models for power systems require ongoing updates to reflect advancements in equipment technology and the increasing complexity of power electronic devices. This study utilizes a Power Hardware-in-the-Loop (PHIL) experimental setup to validate custom photovoltaic (PV) inverter models, aiming to enhance and expedite the development of advanced renewable energy models. The research compares the performance of a physical inverter with generic Renewable Energy Source (RES) models recommended by the Western Electricity Coordinating Council (WECC). As inverter-based renewable energy sources become more prevalent in modern electrical grids, it is crucial that dynamic models accurately represent their real-world behavior. Accurate models improve our understanding of these energy resources and their interactions with the grid. The proposed model enhancements are designed to better reflect real inverter performance, based on insights from PHIL experiments. These models are developed using the open source Modelica language and the OpenIPSL Modelica Library, allowing integration across various simulation tools without re-implementation. The paper concludes with a thorough assessment, comparing the enhanced models with PHIL experiments on a real PV inverter in a controlled laboratory setting. As a result, the study provides the enhanced WECC RES models and validation data as open source resources, facilitating further research and development.

Modelica↗