Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Probe for Sampling of Interstitial Fluid From Bone

An apparatus characterized as both a membrane probe and a bone ultrafiltration probe has been developed to enable in vivo sampling of interstitial fluid in bone. The probe makes it possible to measure the concentration of calcium and other constituents of the fluid that may be relevant to bone physiology. The probe could be especially helpful in experimental studies of microgravitational bone loss and of terrestrial bone-loss disease states, including osteoporosis. The probe can be implanted in the bone tissue of a living animal and can be used to extract samples of the interstitial bone fluid from time to time during a long-term study. The probe includes three 12-cm-long polyacrylonitrile fibers configured in a loop form and attached to polyurethane tubing [inside diameter 0.025 in. (0.64 mm), outside diameter 0.040 in. (1 mm)]; the attachment is made by use of a 1-cm-long connecting piece of polyurethane tubing [inside diameter 0.035 0.003 in. (0.89 0.08 mm), outside diameter 0.060 0.003 in. (1.52 0.08 mm)]. At the distal end, a 2-cm-long piece of polyurethane tubing of the same inner and outer diameters serves as a connector to a hub. A 1-cm long piece of expanded poly (tetrafluoroethylene) tubing over the joint between the fibers and the connecting tubing serves as a tissue-in-growth site.

Janle, Elsa M.↗

Effectiveness of a Wedge Probe to Measure Sonic Boom Signatures in a Supersonic Wind Tunnel

A wind tunnel investigation was conducted in the Langley Unitary Plan Wind Tunnel (UPWT) to determine the effectiveness of a wedge probe to measure sonic boom pressure signatures compared to a slender conical probe. A generic business jet model at a constant angle of attack and at a single model to probe separation distance was used to generate a sonic boom signature. Pressure signature data were acquired with both the wedge probe and a slender conical probe for comparison. The test was conducted at a Mach number of 2.0 and a free-stream unit Reynolds number of 2 million per foot. The results showed that the wedge probe was not effective in measuring the sonic boom pressure signature of the aircraft model in the supersonic wind tunnel. Data plots and a discussion of the results are presented. No tabulated data or flow visualization photographs are included.

Wilcox, Floyd J., Jr.↗

Standard Practices for Usage of Inductive Magnetic Field Probes with Application to Electric Propulsion Testing

Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are often employed to perform field measurements in electric propulsion applications where there are time-varying fields. Magnetic field probes provide the means to measure these magnetic fields and can even be used to measure the plasma current density indirectly through the application of Ampere's law. Measurements of this type can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. Results of the development of a standard for B-dot probe measurements are presented, condensing the available literature on the subject into an accessible set of rules, guidelines, and techniques to standardize the performance and presentation of future measurements.

Polzin, Kurt A.↗

Design and Application of Hybrid Magnetic Field-Eddy Current Probe

The incorporation of magnetic field sensors into eddy current probes can result in novel probe designs with unique performance characteristics. One such example is a recently developed electromagnetic probe consisting of a two-channel magnetoresistive sensor with an embedded single-strand eddy current inducer. Magnetic flux leakage maps of ferrous materials are generated from the DC sensor response while high-resolution eddy current imaging is simultaneously performed at frequencies up to 5 megahertz. In this work the design and optimization of this probe will be presented, along with an application toward analysis of sensory materials with embedded ferromagnetic shape-memory alloy (FSMA) particles. The sensory material is designed to produce a paramagnetic to ferromagnetic transition in the FSMA particles under strain. Mapping of the stray magnetic field and eddy current response of the sample with the hybrid probe can thereby image locations in the structure which have experienced an overstrain condition. Numerical modeling of the probe response is performed with good agreement with experimental results.

Wincheski, Buzz↗

A Common Probe Design for Multiple Planetary Destinations

Introduction: Atmospheric probes have been successfully flown to planets and moons in the solar system to conduct in situ measurements. They include the Pioneer Venus multiprobes, the Galileo Jupiter probe, and Huygens probe. Probe mission concepts to five destinations, including Venus, Jupiter, Saturn, Uranus, and Neptune, have all utilized similarshaped aeroshells and concept of operations, namely a 45° sphere cone shape with high density heatshield material and parachute system for extracting the descent vehicle from the aeroshell. The current paradigm is to design a probe to meet specific mission requirements and to optimize mass, volume, and cost for a single mission. However, this methodology means repeated efforts to design an aeroshell for different destinations with minor differences. A new paradigm has been explored that has a "common probe" design that could be flown at these different destinations and could be assembled in advance with multiple copies, properly stored, and made available for future NASA missions.

Hwang, Helen H.↗

CHAP Enhances Versatility in Colloidal Probe Fabrication

A colloidal probe, comprising a colloidal particle attached to an atomic force microscope cantilever, is employed to measure directly interaction forces between the particle and a surface. It is possible to change or even destroy a particle while attaching it to a cantilever, thus limiting the types of systems to which the colloidal probe technique may be applied. Here we present the Controlled Heating and Alignment Platform (CHAP) for fabricating colloidal probes without altering the original characteristics of the attached particle. The CHAP applies heat directly to the atomic force microscope chip to rapidly and precisely control cantilever temperature. This minimizes particle heating and enables control over the viscosity of thermoplastic adhesive, to prevent it from contaminating the particle surface. 3D-printed components made the CHAP compatible with standard optical microscopes and streamlined the fabrication process while increasing the platform’s versatility. Using the CHAP with a thermoplastic wax adhesive, colloidal probes were fabricated using polystyrene and silica particles between 0.7 and 40 μm in diameter. We characterized the properties and interactions of the adhesive and particles, as well as the properties of the completed probes, to demonstrate the retention of particle features throughout fabrication. Pull-off tests with CHAP’s probes measured adhesive force values in the expected ranges and demonstrated that particles were firmly attached to the cantilevers.

Schmitz, Russell C.↗

A Multi-Probe Mission at Jupiter is Within our Reach!!

Soon after Galileo Probe mission, capabilities to manufacture and test heritage carbon-phenolic (HCP) TPS atrophied. The impact of capability loss to Outer Planet probe missions, Venus in-situ and Mars Sample Return (MSR) missions was realized after two decades. MSR (1997 – 2006) initiated a search and recover of HCP. Decadal Survey (2003) recommended JPOP mission (Jupiter Polar Orbiter and Probe), but lack of HCP TPS resulted in Juno being proposed without a probe. Decadal Survey (2013) recognized and advised NASA to close the TPS gap. With the community support, NASA initiated a technology development effort to close this gap in 2019 and today, missions to Venus, Saturn, Uranus, and MSR are enabled by new 3-D Woven TPS. Jupiter, the most demanding mission from an entry and TPS perspective ever, still lacks a viable qualified TPS. While the Science community needs to make the case for going back to Jupiter with a Probe, this work is an assessment of emerging capabilities to support such a mission when needed. Recent SOA developments are very promising to close this technology gaps. Encourage the Science Community about the feasibility of future Jupiter Multi-Probes Mission Engage the Entry System/TPS Technology Community as to the emerging capabilities and need to preserve them Educate and excite the early career and next generation students interested in future Science and technology challenge.

Ethiraj Venkatapathy↗

A Survey of FIR Probe Mission Concepts

The 2020 Decadal survey recommended that “The NASA Astrophysics Division should implement a line of probe missions with a mission cost cap of ~$1.5 billion (fiscal year 2020) and a targeted launch rate of approximately one per decade.” The survey highlighted two mission areas that were recommended to be competed for the first probe mission opportunity, either a “Far Infrared Imaging or Spectroscopy Mission” and “An X-Ray Probe to Complement ESA’s Athena Observatory.” Three Far-Infrared (FIR) Probe Mission proposals were submitted by PI-led teams in response to the NASA Astrophysics Probe Explorer (APEX) Solicitation released in July 2023. This talk will first outline the general science goals of the Far-IR community and the state of technology needed to field cutting-edge Far-IR missions. We will then discuss and contrast the publicly available details of the proposed probe missions and how they compare to the Origins Space Telescope concept as submitted to the 2020 Decadal survey.

Jake Connors↗

Full information acquisition in scanning probe microscopy and spectroscopy

Apparatus and methods are described for scanning probe microscopy and spectroscopy based on acquisition of full probe response. The full probe response contains valuable information about the probe-sample interaction that is lost in traditional scanning probe microscopy and spectroscopy methods. The full probe response is analyzed post data acquisition using fast Fourier transform and adaptive filtering, as well as multivariate analysis. The full response data is further compressed to retain only statistically significant components before being permanently stored.

36 MATERIALS SCIENCE↗

Pump-probe ghost imaging with SASE FELs

In this paper we propose a new approach to measuring ultrafast dynamics with free-electron lasers (FELs). Ultrafast experiments are among the most promising avenues of research at x-ray FELs, with potential to reveal the chemical dynamics of charge separation, conical intersection crossing, and biologically mediated reactions. Pump-probe scanning is the standard approach to measure dynamics at x-ray FELs, but at the shortest time scales, and particularly for x-ray pump, x-ray probe experiments, the scans require challenging beam setups and can introduce systematic errors. Here we propose an alternative approach using the randomness of the self-amplified spontaneous emission (SASE) process to drive many simultaneous pump-probe experiments on each shot. Measuring the fluctuations in the incident beam’s time profile on a shot-to-shot basis enables reconstruction of ultrafast dynamics down to the coherence length of the FEL without the need for pump-probe scans. Due to similarity to ghost imaging, in which spatial properties are reconstructed by measuring the incident probe’s transverse properties, we call this ``pump-probe ghost imaging" (PPGI). In this paper we describe the method and simulate an example experiment. We also describe an alternative implementation that uses only spectral measurements, avoiding the need for direct time-domain diagnostics, and extending the method to the attosecond regime.

Ratner, Daniel Fried↗

Flexible electric probe

A flexible electric probe can include: a flexible substrate; and probe line conductors on the flexible substrate, the probe line conductors being essentially parallel to each other and having separations of about 5-50 microns. The flexible electric probe can further include connection conductors on the flexible substrate, the connection conductors and the probe line conductors electrically connected to each other, the probe line conductors positioned in first and second offset patterns with regard to the connection conductors.

Mazzeo, Brian A.↗

Nasa Glenn Icing Research Tunnel: 2018 Change in Drop-Sizing Equations Due to Change in Cloud Droplet Probe Sample Area

Although there has been no physical change to the cloud drop diameters in the NASA Glenn Icing Research Tunnel (IRT), the IRT cloud calibration team now has an improved understanding of the facility’s drop-sizing instrumentation, which has resulted in a recent change to the drop-sizing equations. Only the calculated values given in the previous calibration report have changed. In 2017, IRT staff found reason to believe that since at least 2014, the sample area for its Cloud Droplet Probe (CDP) (Droplet Measurement Technologies, Inc.) has been closer to 0.289 mm2, rather than the user manual’s suggested value of 0.24 mm2. In September 2017, the probe’s sample area was measured both before and after the probe was realigned, and the end sample area was measured to be 0.248 mm2. Following the probe’s realignment, drop size measurements were made in the IRT using the CDP as well as optical array probes OAP–230X and OAP–230Y (Particle Measurement Systems, Inc.). These measurements suggested that 0.289 mm2 was the more accurate value for historical measurements. When the CDP sample area used for calculations was changed from 0.24 to 0.289 mm2, distributions previously reported to have a median volumetric diameter (MVD) between 30 and 100 μm were instead calculated to have MVD values 10 to 18 percent higher. The analyses that led to these conclusions are reported in this paper, as well as the new drop-sizing equations that have been developed for the corrected measurement values. This report contains updates to drop-sizing data for the IRT’s “normal” operating conditions (MVD < 50 μm) and discusses the effects on the IRT’s “large-drop” conditions (Mod1 nozzles, Pair < 10 psig), but it does not include updates to the drop-sizing equations for those large-drop conditions.

Particle sizing↗

A BODIPY Based Fluorescent Probe for the Rapid Detection of Hypochlorite

A new boron-dipyrromethene (BODIPY) fluorescent dye aimed at sensitively detecting hypochlorite anion (ClO{sup −}) has been designed, synthesized and characterized. The probe is comprised of a BODIPY fluorophore unit and a ClO{sup −} specific reactive group of amidoxime. The addition of hypochlorite results in a red-shift of absorption and emission spectra of the probe accompanied by a decrease of intensity and spectra changes (A{sub 500} and 1/I{sub 512}) of the probe can achieve a good linearity to the concentration of ClO{sup −}. The fluorescence probe can react to ClO{sup −} rapidly (within 60 s) in a wide pH range (4–10) with high sensitivity (detection limit of 6.81 μM) and selectivity. The reaction mechanism has been proposed and confirmed by MS analysis, ClO{sup −} anion oxidizes amidoxime moiety to hydroxyl group and hydroxyl group is further oxidized to formyl group in the formation of a corresponding aldehyde compound. In addition, the probe has also been successfully applied to detect ClO{sup −} in tap water and river water samples by spiking a known amount of standard ClO{sup −}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Collaborative Research Activities of the Arase and Van Allen Probes

This paper presents the highlights of joint observations of the inner magnetosphere by the Arase spacecraft, the Van Allen Probes spacecraft, and ground-based experiments integrated into spacecraft programs. The concurrent operation of the two missions in 2017–2019 facilitated the separation of the spatial and temporal structures of dynamic phenomena occurring in the inner magnetosphere. Because the orbital inclination angle of Arase is larger than that of Van Allen Probes, Arase collected observations at higher L-shells up to L ~ 10. After March 2017, similar variations in plasma and waves were detected by Van Allen Probes and Arase. We describe plasma wave observations at longitudinally separated locations in space and geomagnetically-conjugate locations in space and on the ground. The results of instrument intercalibrations between the two missions are also presented. Arase continued its normal operation after the scientific operation of Van Allen Probes completed in October 2019. The combined Van Allen Probes (2012-2019) and Arase (2017-present) observations will cover a full solar cycle. This will be the first comprehensive long-term observation of the inner magnetosphere and radiation belts.

97 MATHEMATICS AND COMPUTING↗

Pump and probe spectroscopy with continuous wave quantum cascade lasers

This paper details infra-red pump and probe studies on nitric oxide conducted with two continuous wave quantum cascade lasers both operating around 5 μm. The pump laser prepares a velocity selected population in a chosen rotational quantum state of the v = 1 level which is subsequently probed using a second laser tuned to a rotational transition within the v = 2 ← v = 1 hot band. The rapid frequency scan of the probe (with respect to the molecular collision rate) in combination with the velocity selective pumping allows observation of marked rapid passage signatures in the transient absorption profiles from the polarized vibrationally excited sample. These coherent transient signals are influenced by the underlying hyperfine structure of the pump and probe transitions, the sample pressure, and the coherent properties of the lasers. Pulsed pump and probe studies show that the transient absorption signals decay within 1 μs at 50 mTorr total pressure, reflecting both the polarization and population dephasing times of the vibrationally excited sample. The experimental observations are supported by simulation based upon solving the optical Bloch equations for a two level system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probe-rotating atomic force microscopy for determining material properties

In this paper, we propose a probe-rotating atomic force microscope that enables scan in an arbitrary direction in the contact imaging mode, which is difficult to achieve using a conventional atomic force microscope owing to the orientation-dependent probe and the inability to rotate the probe head. To enable rotation of the probe about its vertical axis, we employed a compact and light probe head, the sensor of which is made of an optical disk drive pickup unit. Our proposed mechanical configuration, operating principle, and control system enables axial and lateral scan in various directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D potential measurements by applying automatic beam adjustment system to heavy ion beam probe diagnostic on the Large Helical Device

Two-dimensional potential profiles in the Large Helical Device (LHD) were measured with heavy ion beam probe (HIBP). To measure the two-dimensional profile, the probe beam energy has to be changed. However, this task is not easy, because the beam transport line of LHD-HIBP system is very long (∼20 m), and the required beam adjustment consumes much time. To reduce the probe beam energy adjustment time, an automatic beam adjustment system has been developed. Using this system, required time to change the probe beam energy is dramatically reduced, such that two-dimensional potential profiles were able to be successfully measured with HIBP by changing the probe beam energy shot to shot.

43 PARTICLE ACCELERATORS↗

Langmuir probe analysis in electronegative plasmas

This paper compares two methods to analyze Langmuir probe data obtained in electronegative plasmas. The techniques are developed to allow investigations in plasmas, where the electronegativity α{sub 0} = n{sub –}/n{sub e} (the ratio between the negative ion and electron densities) varies strongly. The first technique uses an analytical model to express the Langmuir probe current-voltage (I-V) characteristic and its second derivative as a function of the electron and ion densities (n{sub e}, n{sub +}, n{sub –}), temperatures (T{sub e}, T{sub +}, T{sub –}), and masses (m{sub e}, m{sub +}, m{sub –}). The analytical curves are fitted to the experimental data by adjusting these variables and parameters. To reduce the number of fitted parameters, the ion masses are assumed constant within the source volume, and quasi-neutrality is assumed everywhere. In this theory, Maxwellian distributions are assumed for all charged species. We show that this data analysis can predict the various plasma parameters within 5–10%, including the ion temperatures when α{sub 0} > 100. However, the method is tedious, time consuming, and requires a precise measurement of the energy distribution function. A second technique is therefore developed for easier access to the electron and ion densities, but does not give access to the ion temperatures. Here, only the measured I-V characteristic is needed. The electron density, temperature, and ion saturation current for positive ions are determined by classical probe techniques. The electronegativity α{sub 0} and the ion densities are deduced via an iterative method since these variables are coupled via the modified Bohm velocity. For both techniques, a Child-Law sheath model for cylindrical probes has been developed and is presented to emphasize the importance of this model for small cylindrical Langmuir probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗