Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A resistively heated CeB{sub 6} emissive probe

The plasma potential, V{sub p}, is a key quantity in experimental plasma physics. Its spatial gradients directly yield the electrostatic field present. Emissive probes operating under space-charge limited emission conditions float close to V{sub p} even under time-varying conditions. Throughout their long history in plasma physics, they have mostly been constructed with resistively heated tungsten wire filaments. In high density plasmas (>10{sup 12} cm{sup −3}), hexaboride emitters are required because tungsten filaments cannot be heated to sufficient emission without component failure. A resistively heated emissive probe with a cerium hexaboride, CeB{sub 6}, emitter has been developed to work in plasma densities up to 10{sup 13} cm{sup −3}. To show functionality, three spatial profiles of V{sub p} are compared using the emissive probe, a cold floating probe, and a swept probe inside a plasma containing regions with and without current. The swept probe and emissive probe agree well across the profile while the floating cold probe fails in the current carrying region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-sensing cantilevers with integrated conductive coaxial tips for high-resolution electrical scanning probe metrology

The lateral resolution of many electrical scanning probe techniques is limited by the spatial extent of the electrostatic potential profiles produced by their probes. Conventional unshielded conductive atomic force microscopy probes produce broad potential profiles. Shielded probes could offer higher resolution and easier data interpretation in the study of nanostructures. Electrical scanning probe techniques require a method of locating structures of interest, often by mapping surface topography. As the samples studied with these techniques are often photosensitive, the typical laser measurement of cantilever deflection can excite the sample, causing undesirable changes electrical properties. In this work, we present the design, fabrication, and characterization of probes that integrate coaxial tips for spatially sharp potential profiles with piezoresistors for self-contained, electrical displacement sensing. With the apex 100 nm above the sample surface, the electrostatic potential profile produced by our coaxial tips is more than 2 times narrower than that of unshielded tips with no long tails. In a scan bandwidth of 1 Hz–10 kHz, our probes have a displacement resolution of 2.9 Å at 293 K and 79 Å at 2 K, where the low-temperature performance is limited by amplifier noise. We show scanning gate microscopy images of a quantum point contact obtained with our probes, highlighting the improvement to lateral resolution resulting from the coaxial tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of plasma density from data on the ion current to cylindrical and planar probes

To improve probe methods of plasma diagnostics, special probe measurements were performed and numerical models describing ion transport to a probe with allowance for collisions were developed. The current–voltage characteristics of cylindrical and planar probes were measured in an RF capacitive discharge in argon at a frequency of 81 MHz and plasma densities of 10{sup 10}–10{sup 11} cm{sup –3}, typical of modern RF reactors. 1D and 2D numerical models based on the particle-in-cell method with Monte Carlo collisions for simulating ion motion and the Boltzmann equilibrium for electrons are developed to describe current collection by a probe. The models were used to find the plasma density from the ion part of the current–voltage characteristic, study the effect of ion collisions, and verify simplified approaches to determining the plasma density. A 1D hydrodynamic model of the ion current to a cylindrical probe with allowance for ion collisions is proposed. For a planar probe, a method to determine the plasma density from the averaged numerical results is developed. A comparative analysis of different approaches to calculating the plasma density from the ion current to a probe is performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of modification methods of probes for critical-dimension atomic-force microscopy by the deposition of carbon nanotubes

The results of an experimental study of the modification of probes for critical-dimension atomicforce microscopy (CD-AFM) by the deposition of carbon nanotubes (CNTs) to improve the accuracy with which the surface roughness of vertical walls is determined in submicrometer structures are presented. Methods of the deposition of an individual CNT onto the tip of an AFM probe via mechanical and electrostatic interaction between the probe and an array of vertically aligned carbon nanotubes (VACNTs) are studied. It is shown that, when the distance between the AFM tip and a VACNT array is 1 nm and the applied voltage is within the range 20–30 V, an individual carbon nanotube is deposited onto the tip. On the basis of the results obtained in the study, a probe with a carbon nanotube on its tip (CNT probe) with a radius of 7 nm and an aspect ratio of 1:15 is formed. Analysis of the CNT probe demonstrates that its use improves the resolution and accuracy of AFM measurements, compared with the commercial probe, and also makes it possible to determine the roughness of the vertical walls of high-aspect structures by CD-AFM. The results obtained can be used to develop technological processes for the fabrication and reconditioning of special AFM probes, including those for CD-AFM, and procedures for the interoperational express monitoring of technological process parameters in the manufacturing of elements for micro- and nanoelectronics and micro- and nanosystem engineering.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Porous Membranes for Moisture Probe Protection (SR18024)

In the presence of contaminants, moisture probes can give false moisture readings and have shorter lifetimes. Absolute humidity probes are composed of porous, hygroscopic metallic oxide thin films (Al 2 O 3 ) coupled to electrodes (e.g. Au and Al). While these materials provide absolute humidity readings at low water levels at a relatively low cost, they are sensitive to the presence of contaminants, especially ammonia, due to its high hygroscopicity and ability to bind to the probe. Without frequent recalibration, especially in the presence of contaminants, the humidity levels are inaccurately reported due to measurement drift that occurs when the pores close, changing the impedance of the probe. The goal of this project was to improve the stability and reliability of these moisture probes by incorporating a molecular sieve into the probe to allow only the water to reach the sensor. Molecular sieves contain pores that allow molecule specific permeation. Two dimensional inorganic nanosheets (e.g. BN, MoO 2 , MoS 2 ) have recently been shown to behave as molecular sieves for water. Compared to zeolites, nanoporous materials have higher flux rates through the pores, leading to faster water permeation. Graphene oxide sheets have also been successfully employed for unimpeded water permeation; however, at lower humidity levels, the structure is unstable and the pores shrink, preventing the sieving of molecules. Compared to graphene oxide, sheets based off of inorganic materials, such as molybdenum, have been found to be more stable at lower humidity levels and have faster permeation rates. By creating a barrier in before the Al 2 O 3 sensor chip to prevent the permeation of contaminants into the probe, the lifetime of the probe will be extended. While the molybdenum sheets are a promising material for this application, their performance against ammonia and tritiated compounds have not yet been evaluated. This technology can be applied to other applications, including gas and liquid purification for environmental remediation, single molecule sensors, field effect transistors, and catalysts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New model for the ion collection by cylindrical probes over a wide range of collisionality

Langmuir probes remain one of the most important diagnostic tools for plasma processing applications. Modern probe analysis usually relies on the electron current part of the Langmuir probe characteristic using the Druyvesteyn method. However, for electronegative plasmas or for discharges containing dust the analysis of the ion current attracted by the probe can be desirable to determine the ion density. But, even at low pressures of a few Pa, the ion current is affected by collisions due to the large cross section for charge exchange. Available theories for collisional or collision-enhanced ion currents onto probes are complex and not well validated. Thus, in this contribution, we compare available collisional probe theories for the ion current to results of particle-in-cell (PIC) simulations. To this end, the probe surrounded by a semi-infinite plasma is simulated using a modified version of the open-source code EDIPIC. A dataset of currents for different neutral gas pressures is obtained and compared to the different theories from the literature. Based on these results, we propose a simpler and more intuitive model for the ion current collected by the probe, based on the model of Gatti and Kortshagen (Phys. Rev. E 78, 046402, 2008), developed for the charging of dust particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wind Tunnel PSD and MVD Characterization Using New 1D2D Optical Array Probes

This work explores characterization of the liquid clouds using a combination of a forward scattering probe and two Optical Array Probes. Current OAP probes provide particle shape, size, and number concentration from two-dimensional shadow images. However, past studies have shown that such images are subject to distortion when outside of the focal plane. This affects the retrieval of particle size distributions, particularly in the Supercooled Large Droplet size range. In this article, the use of a Droplet Measurement Technologies Cloud Droplet Probe and two new OAPs produced by Science Engineering Associates, is examined using wind tunnel data, to assess suitability for use in a wind tunnel calibration in SLD conditions. The new OAP probes exploit a flexible and simple grey scale imaging method to eliminate some present shortcomings of commonly used OAPs, and to reduce correction factors. Spinning disk measurements were used to specify probe depth of field, and average size errors. Composite spectra covering the nominal 2-3200 µm size range were formed by crossing over from the CDP to 1D2D-X at 48 µm, and then to the 1D2D-Y at about 400 µm. A good overlap was found at the crossover points without any artificial scaling. Composite spectra adequately closed the liquid water content distribution, and provided integrated LWCs within about 35% of the hot-wire LWCs used for tunnel calibration. This discrepancy was at least partially attributed to LWC underestimation by the hot-wire at high MVD. A model of probe performance was used to show an example of expected accuracy of ideal probes subject to the same OAP distortions and using the same mitigating procedures and corrections, predicting PSD Median Volume Diameter and integrated LWC errors of less than 10%.

Aircraft Icing↗

Functionalization of Scanning Probe Tips with Epitaxial Semiconductor Layers

Functionalized scanning probe tips hold great promise for the controlled delivery of signals from and to selected nanoscale volumes. Here, a new nanotechnological approach for the functionalization of scanning probe tips is presented, targeting the transfer of the optical, electrical, thermal, or chemical properties of precisely characterized epitaxial semiconductor layers to the nanoscale probe tip. Homogeneously doped, strain‐relaxed heteroepitaxial germanium layers, several micrometers thick, are first grown on silicon wafers by low‐energy plasma‐enhanced chemical vapor deposition and then employed to functionalize the probe apex. This choice of materials and growth technique enables the future scalability of the tip functionalization process toward high production volumes. The fabricated probe tips are investigated in a transmission electron microscope, revealing that the crystal structure and the homogeneous doping level of the epitaxial layers are unchanged after the probe‐tip functionalization process. These doped‐germanium tips are also tested as nanoemitters of light at telecom wavelengths (1.55 µm) and applied as scattering probes for near‐field mid‐infrared microscopy. The reported combination of heteroepitaxial growth and a nanofabrication approach can be extended to a variety of epitaxial materials, thus enabling a new generation of scanning probes for the investigation of nanostructured materials and devices.

Giliberti, Valeria↗

Ultrafast X-ray Transient Absorption Spectroscopy of Gas-Phase Photochemical Reactions: A New Universal Probe of Photoinduced Molecular Dynamics

Time-resolved spectroscopic investigations of light-induced chemical reactions with universal detection capitalize recently on single-photon molecular probing using laser pulses in the extreme ultraviolet or X-ray regimes. Direct and simultaneous mappings of the time-evolving populations of ground-state reactants, Franck-Condon (FC) and transition state regions, excited-state intermediates and conical intersections (CI), and photoproducts in photochemical reactions utilize probe pulses that are broadband and energy-tunable. The limits on temporal resolution are set by the transit- or dwell-time of the photoexcited molecules at specific locations on the potential energy surface, typically ranging from a few femtoseconds to several hundred picoseconds. Femtosecond high-harmonic generation (HHG) meets the stringent demands for a universal spectroscopic probe of large regions of the intramolecular phase-space in unimolecular photochemical reactions. Extreme-ultraviolet and soft X-ray pulses generated in this manner with few-femtosecond or sub-femtosecond durations have enormous bandwidths, allowing the probing of many elements simultaneously through excitation or ionization of core-electrons, creating molecular movies that shed light on entire photochemical pathways. At free electron lasers (FELs), powerful investigations are also possible, recognizing their higher flux and tunability but more limited bandwidths. Femtosecond time-resolved X-ray transient absorption spectroscopy, in particular, is a valuable universal probe of reaction pathways that maps changes via the fingerprint core-to-valence resonances. The particular power of this method over valence-ionization probes lies in its unmatched element and chemical-site specificities. The elements carbon, nitrogen, and oxygen constitute the fundamental building blocks of life; photochemical reactions involving these elements are ubiquitous, diverse, and manifold. However, table-top HHG sources in the "water-window" region (280-550 eV), which encompasses the 1s-absorption edges of carbon (284 eV), nitrogen (410 eV), and oxygen (543 eV), are far from abundant or trivial. Recent breakthroughs in the laboratory have embraced this region by using long driving-wavelength optical parametric amplifiers coupled with differentially pumped high-pressure gas source cells. This has opened avenues to study a host of photochemical reactions in organic molecules using femtosecond time-resolved transient absorption at the carbon K-edge. In this Account, we summarize recent efforts to deploy a table-top carbon K-edge source to obtain crucial chemical insights into ultrafast, ultraviolet-induced chemical reactions involving ring-opening, nonadiabatic excited-state relaxation, bond dissociation and radical formation. Here, the X-ray probe provides a direct spectroscopic viewport into the electronic characters and configurations of the valence electronic states through spectroscopic core-level transitions into the frontier molecular orbitals of the photoexcited molecules, laying fertile ground for the real-time mapping of the evolving valence electronic structure. The profound detail and mechanistic insights emerging from the pioneering experiments at the carbon K-edge are outlined here. Comparisons of the experimental methodology with other techniques employed to study similar reactions are drawn, where applicable and relevant. We show that femtosecond time-resolved X-ray transient absorption spectroscopy blazes a new trail in the study of nonadiabatic molecular dynamics. Despite table-top implementations being largely in their infancy, future chemical applications of the technique will set the stage for widely applicable, universal probes of photoinduced molecular dynamics with unprecedented temporal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Free vibrations of U-shaped atomic force microscope probes

Contact resonance atomic force microscope (AFM) methods have been used to quantify the elastic and viscoelastic properties of a variety of materials such as polymers, ceramics, biological materials, and metals with spatial resolution on the order of tens of nanometers. This approach involves measurement of the resonant frequencies of the AFM probe both for the free case and the case for which the tip is in contact with a sample. Vibration models of the probe and tip-sample contact models are then used to determine the sample properties from the frequency behavior and to create images of the sample properties. This work has been primarily focused on rectangular, single-beam probes for which the vibration models are relatively simple. Recently, U-shaped AFM probes have been developed to allow local heating of samples and the resonances of these probes are much more complex. In this article, a simplified analytical model of these U-shaped probes is described. This three beam model includes two beams clamped at one end and connected with a perpendicular cross beam at the other end. The beams are assumed only to bend in flexure and twist but their coupling allows a wide range of possible dynamic behavior. Results are presented for the first ten modes and the mode shapes are shown to have complex coupling between the flexure and twisting of the beams, particularly for the higher modes. All resonant frequency results are in good agreement with finite element results for the three probe designs and two values of thickness considered (all wavenumbers are within 3.0%). This work is anticipated to allow U-shaped probes to be used eventually for quantitative measurements of sample material properties during heating using a contact resonance approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilization of coupled eigenmodes in Akiyama atomic force microscopy probes for bimodal multifrequency sensing

Akiyama atomic force microscopy probes represent a unique means of combining several of the desirable properties of tuning fork and cantilever probe designs. As a hybridized mechanical resonator, the vibrational characteristics of Akiyama probes result from a complex coupling between the intrinsic vibrational eigenmodes of its constituent tuning fork and bridging cantilever components. Here, through a combination of finite element analysis modeling and experimental measurements of the thermal vibrations of Akiyama probes, we identify a complex series of vibrational eigenmodes and measure their frequencies, quality factors, and spring constants. We then demonstrate the viability of Akiyama probes to perform bimodal multi-frequency force sensing by performing a multimodal measurement of a surface's nanoscale photothermal response using photo-induced force microscopy imaging techniques. Further performing a parametric search over alternative Akiyama probe geometries, we propose two modified probe designs to enhance the capability of Akiyama probes to perform sensitive bimodal multifrequency force sensing measurements.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probing one-dimensional systems via noise magnetometry with single spin qubits

The study of exotic one-dimensional states, particularly those at the edges of topological materials, demand new experimental probes that can access the interplay between charge and spin degrees of freedom. One potential approach is to use a single spin probe, such as a nitrogen vacancy center in diamond, which has recently emerged as a versatile tool to probe nanoscale systems in a noninvasive fashion. Here, we present a theory describing how noise magnetometry with spin probes can directly address several questions that have emerged in experimental studies of 1D systems, including those in topological materials. We show that by controlling the spin degree of freedom of the probe, it is possible to measure locally and independently local charge and spin correlations of 1D systems. Visualization of 1D edge states, as well as sampling correlations with wave-vector resolution can be achieved by tuning the probe-to-sample distance. Furthermore, temperature-dependent measurements of magnetic noise can clearly delineate the dominant scattering mechanism (impurities versus interactions)—this is of particular relevance to quantum spin Hall measurements where conductance quantization is not perfect. Here, the possibility to probe both charge and spin excitations in a wide range of length scales opens new pathways to bridging the large gap between atomic scale resolution of scanning probes and global transport measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Some implications of satellite spin effects in cylindrical probe measurements

In-situ measurements of ambient electron densities with satellite-borne cylindrical probes exhibit periodic variations synchronous with the satellite's spin cycle. Representing these fluctuations as a superposition of effects attributable to both the presence of the satellite wake and the geomagnetic field leads to a model of the modulations of accelerated electron current to cylindrical probes in which one modulation component displays current variations dependent upon the probe-velocity angle (psi) and the other displays variations dependent upon the angle between the probe axis and the geomagnetic field lines (beta). The modulations produce an electron current decrease whenever the probe axis rotates into the satellite wake or whenever the probe axis rotates toward alignment with the geomagnetic field lines. With increasing altitude, the modulation dependent upon psi decreases whereas the modulation dependent upon beta increases. The analysis results imply that the most accurate of atmospheric electron densities by satellite-borne cylindrical probes come from measurements taken out of the satellite's wake and when the probe axis is within 20 degrees of being perpendicular to the geomagnetic field lines.

Miller, N. J.↗

Evaluation of a self-aspirating local total enthalpy probe in a low-density arc-heated hypersonic wind tunnel

A shock-swallowing, self-aspirating, local total enthalpy probe has been evaluated in a low density nonequilibrium, hypervelocity airstream. The probe, which incorporated an air gap to separate the internal and external cooling passages, was tested in an electric archeated wind tunnel at an average Mach number of 11.7 and an average Reynolds number per meter of 57,000. The free stream enthalpy probe data are compared with bulk calorimeter measurements of total enthalpy at the beginning of the gas expansion and with local total enthalpy inferred from a theoretical nonequilibrium gas expansion model by using free stream velocity measurements obtained from a mass flow probe. The three techniques are in relative agreement at the lower enthalpies. However, at the higher enthalpies, the enthalpy probe data lie considerably below the other data. This low data may be caused by the chemical and vibrational energy frozen in the flow not being sensed by the probe. Other problems associated with the shock-swallowing total enthalpy probe are discussed, and recommendations for improving the probe performance are presented.

Guy, R. W.↗

Some implications of satellite spin effects in cylindrical probe measurements.

Observation that in situ measurements of ambient electron densities with satellite-borne cylindrical probes exhibit periodic variations synchronous with the satellite spin cycle. Representing these fluctuations as a superposition of effects attributable to both the presence of the satellite wake and the geomagnetic field leads to a model of the modulations of accelerated electron current to cylindrical probes in which one modulation component displays current variations dependent on the probe velocity angle (psi), and the other displays variations dependent on the angle between the probe axis and the geomagnetic-field lines (beta). The modulations produce an electron current decrease whenever the probe axis rotates into the satellite wake or whenever the probe axis rotates toward alignment with the geomagnetic-field lines. As altitude increases, the modulation dependent on psi decreases, whereas the modulation dependent on beta increases. The psi-dependent modulation component can be associated with the presence of a wake structure, and the beta-dependent component can be associated with the magnetic influence on the transport properties of thermal electrons, assuming that the electron fluxes are predominant along the field lines. The analysis results imply that the most accurate determinations of atmospheric electron densities by satellite-borne cylindrical probes come from measurements taken out of the wake of the satellite when the probe axis is within 20 deg of being perpendicular to the geomagnetic-field lines.

Miller, N. J.↗

Effects of Mach number on pitot-probe displacement in a turbulent boundary layer

Experimental pitot-probe-displacement data have been obtained in a turbulent boundary layer at a local free-stream Mach number of 4.63 and unit Reynolds number of 6.46 million meter. The results of this study were compared with lower Mach number results of previous studies. It was found that small probes showed displacement only, whereas the larger probes showed not only displacement but also distortion of the shape of the boundary-layer profile. The distortion pattern occurred lower in the boundary layer at the higher Mach number than at the the lower Mach number. The maximum distortion occurred when the center of the probe was about one probe diameter off the test surface. For probes in the wall contact position, the indicated Mach numbers were, for all probes tested, close to the true profile. Pitot-probe displacement was found to increase significantly with increasing Mach number.

Allen, J. M.↗