Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Propagation of radio waves through the lower atmosphere of Venus

A simplified model of the Venus atmosphere is developed providing the loss factor profile of the atmosphere. With this profile the atmospheric attenuation as it depends upon the incidence angle is calculated for wavelengths between 2 cm and 20 cm. It is shown that the signal-to-noise ratios for a real aperture radar, a synthetic aperture radar, and communication links between a satellite and a landing probe achieve maximum values by the proper choice of the wavelengths. Furthermore, it turns out that the wavelength dependence is less crucial for the synthetic aperture radar compared to the other cases.

Richter, K. R.↗

The acoustics of aircraft engine-duct systems

Noise generated in aircraft engines is usually suppressed by acoustically treating the engine ducts. The optimization of this treatment requires an understanding of the transmission and attenuation of the acoustic waves. A critical review is presented of the state of the art regarding methods of determining the transmission and attenuation parameters and the effect on these parameters of (1) acoustic properties of liners, (2) the mean velocity, including uniform and shear profiles and nonparallel flow, (3) axial and transverse temperature gradients, (4) slowly and abruptly varying cross sections, and (5) finite-amplitude waves and nonlinear duct liners.

Nayfeh, A. H.↗

Application of High-Dimensional Fuzzy K-Means Cluster Analysis to CALIOP/CALIPSO Version 4.1 Cloud-Aerosol Discrimination

This study applies fuzzy k-means (FKM) cluster analyses to a subset of the parameters reported in the CALIPSO lidar level 2 data products in order to classify the layers detected as either clouds or aerosols. The results obtained are used to assess the reliability of the cloud–aerosol discrimination (CAD) scores reported in the version 4.1 release of the CALIPSO data products. FKM is an unsupervised learning algorithm, whereas the CALIPSO operational CAD algorithm (COCA) takes a highly supervised approach. Despite these substantial computational and architectural differences, our statistical analyses show that the FKM classifications agree with the COCA classifications for more than 94 % of the cases in the troposphere. This high degree of similarity is achieved because the lidar-measured signatures of the majority of the clouds and the aerosols are naturally distinct, and hence objective methods can independently and effectively separate the two classes in most cases. Classification differences most often occur in complex scenes (e.g., evaporating water cloud filaments embedded in dense aerosol) or when observing diffuse features that occur only intermittently (e.g., volcanic ash in the tropical tropopause layer). The two methods examined in this study establish overall classification correctness boundaries due to their differing algorithm uncertainties. In addition to comparing the outputs from the two algorithms, analysis of sampling, data training, performance measurements, fuzzy linear discriminants, defuzzification, error propagation, and key parameters in feature type discrimination with the FKM method are further discussed in order to better understand the utility and limits of the application of clustering algorithms to space lidar measurements. In general, we find that both FKM and COCA classification uncertainties are only minimally affected by noise in the CALIPSO measurements, though both algorithms can be challenged by especially complex scenes containing mixtures of discrete layer types. Our analysis results show that attenuated backscatter and color ratio are the driving factors that separate water clouds from aerosols; backscatter intensity, depolarization, and mid-layer altitude are most useful in discriminating between aerosols and ice clouds; and the joint distribution of backscatter intensity and depolarization ratio is critically important for distinguishing ice clouds from water clouds.

Zeng, Shan↗

The feasibility of a piecewise-linear dynamic bowtie filter

Purpose: The prepatient attenuator (or 'bowtie filter') in CT is used to modulate the flux as a function of fan angle of the x-ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time-dependent piecewise-linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon-counting detectors. Methods: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time-dependent piecewise-linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated. Results: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two-pass algorithm. Conclusions: A dynamic bowtie producing a time-dependent, piecewise-linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible.

60 APPLIED LIFE SCIENCES↗

Scanning ARM Cloud Radars. Part II: Data Quality Control and Processing

The Scanning ARM Cloud Radars (SACR’s) are the primary instruments for documenting the four-dimensional structure and evolution of clouds within a 20-30 km radius from the ARM fixed and mobile sites. Here, the post-processing of the calibrated SACR measurements is discussed. First, a feature mask algorithm that objectively determines the presence of significant radar returns is described. The feature mask algorithm is based on the statistical properties of radar receiver noise. It accounts for atmospheric emission and is applicable even for SACR profiles with few or no signal-free range gates. Using the nearest-in-time atmospheric sounding, the SACR radar reflectivities are corrected for gaseous attenuation (water vapor and oxygen) using a line-by-line absorption model. Despite having a high pulse repetition frequency, the SACR has a narrow Nyquist velocity limit and thus Doppler velocity folding is commonly observed. An unfolding algorithm that makes use of a first guess for the true Doppler velocity using horizontal wind measurements from the nearest sounding is described. The retrieval of the horizontal wind profile from the HS-RHI SACR scan observations and/or nearest sounding is described. The retrieved horizontal wind profile can be used to adaptively configure SACR scan strategies that depend on wind direction. Several remaining challenges are discussed, including the removal of insect and second-trip echoes. The described algorithms significantly enhance SACR data quality and constitute an important step towards the utilization of SACR measurements for cloud research.

climate↗

SU-F-J-39: Dose Reduction Strategy Using Attenuation-Based Tube Current Modulation Method in CBCT for IGRT

Purpose: To reduce radiation dose to the patients, tube current modulation (TCM) method has been actively used in diagnostic CT systems. However, TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate whether the use of TCM method is desirable in kV-CBCT system for IGRT. We have developed an attenuation-based tube current modulation (a-TCM) method using the prior knowledge of treatment CT image of a patient. Methods: Patients go through a diagnostic CT scan for RT planning; therefore, using this prior information of CT images, one can estimate the total attenuation of an x-ray through the patient body in a CBCT setting for radiation therapy. We performed a numerical study incorporating major factors into account such as polychromatic x-ray, scatter, noise, and bow-tie filter to demonstrate that a-TCM method can produce equivalent quality of images at reduced imaging radiation doses. Using the CT projector program, 680 projection images of the pediatric XCAT phantom were obtained both in conventional scanning condition, i.e., without modulating the tube current, and in the proposed a-TCM scanning condition. FDK reconstruction algorithm was used for image reconstruction, and the organ dose due to imaging radiation has been calculated in both cases and compared using GATE/Geant4 simulation toolkit. Results: Reconstructed CT images in the a-TCM method showed similar SSIM values and noise properties to the reference images acquired by the conventional CBCT. In addition, reduction of organ doses ranged from 12% to 27%. Conclusion: We have successfully demonstrated the feasibility and dosimetric merit of the a-TCM method for kV-CBCT, and envision that it can be a useful option of CBCT scanning that provides patient dose reduction without degrading image quality.

60 APPLIED LIFE SCIENCES↗

SU-C-207-06: In Vivo Quantification of Gold Nanoparticles Using K-Edge Imaging Via Spectrum Shaping by Gold Filter

Purpose: Gold nanoparticles (AuNP) are multifunctional platforms ideal for drug delivery, targeted imaging and radiosensitization. We have investigated quantitative imaging of AuNPs using on board imager (OBI) cone beam computed tomography (CBCT). To this end, we also present, for the first time, a novel method for k-edge imaging of AuNP by filter-based spectral shaping. Methods: We used a digital 25 cm diameter water phantom, embedded with 3 cm spheres filled with AuNPs of different concentrations (0 mg/ml – 16 mg/ml). A poly-energetic X-ray spectrum of 140 kVp from a conventional X-ray tube is shaped by balanced K-edge filters to create an excess of photons right above the K-edge of gold at 80.7 keV. The filters consist of gold, tin, copper and aluminum foils. The phantom with appropriately assigned attenuation coefficients is forward projected onto a detector for each energy bin and then integrated. FKD reconstruction is performed on the integrated projections. Scatter, detector efficiency and noise are included. Results: We found that subtracting the results of two filter sets (Filter A:127 µm gold foil with 254 µm tin, 330 µm copper and 1 mm aluminum, and Filter B: 635 µm tin with 264 µm copper and 1 mm aluminum), provides substantial image contrast. The resulting filtered spectra match well below 80.7 keV, while maintaining sufficient X-ray quanta just above that. Voxel intensities of AuNP containing spheres increase linearly with AuNP concentration. K-edge imaging provides 18% more sensitivity than the tin filter alone, and 38% more sensitivity than the gold filter alone. Conclusion: We have shown that it is feasible to quantitatively detect AuNP distributions in a patient-sized phantom using clinical CBCT and K-edge spectral shaping.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-01: Impact of Statistical Weights On Detection of Low-Contrast Details in Model-Based Iterative CT Reconstruction

Purpose: Penalized-weighted least-square reconstruction has become an important research topic in CT, to reduce dose without affecting image quality. Two components impact image quality in this reconstruction: the statistical weights and the use of an edge-preserving penalty term. We are interested in assessing the influence of statistical weights on their own, without the edge-preserving feature. Methods: The influence of statistical weights on image quality was assessed in terms of low-contrast detail detection using LROC analysis. The task amounted to detect and localize a 6-mm lesion with random contrast inside the FORBILD head phantom. A two-alternative forced-choice experiment was used with two human observers performing the task. Reconstructions without and with statistical weights were compared, both using the same quadratic penalty term. The beam energy was set to 30keV to amplify spatial differences in attenuation and thereby the role of statistical weights. A fan-beam data acquisition geometry was used. Results: Visual inspection of images clearly showed a difference in noise between the two reconstructions methods. As expected, the reconstruction without statistical weights exhibited noise streaks. The other reconstruction appeared better in this aspect, but presented other disturbing noise patterns and artifacts induced by the weights. The LROC analysis yield the following 95-percent confidence interval for the difference in reader-averaged AUC (reconstruction without weights minus reconstruction with weights): [0.0026,0.0599]. The mean AUC value was 0.9094. Conclusion: We have investigated the impact of statistical weights without the use of edge-preserving penalty in penalized weighted least-square reconstruction. A decrease rather than increase in image quality was observed when using statistical weights. Thus, the observers were better able to cope with the noise streaks than the noise patterns and artifacts induced by the statistical weights. It may be that different results would be obtained if the penalty term was used with a pixel-dependent weight. F Noo receives research support from Siemens Healthcare GmbH.

60 APPLIED LIFE SCIENCES↗

Interior noise studies for general aviation types of aircraft. I - Field studies. II - Laboratory studies

Sources of the interior noise level of typical light aircraft are identified for stationary conditions on the ground and in flight. In addition, the relationship between the exterior near- and far-field noise around an aircraft and the interior noise field is examined. The sound transmission paths of a light aircraft fuselage are investigated, and the relative effectiveness of several components of the fuselage for sound attenuation is assessed. The fuselage furnishes an acoustic attenuation of about 20 dB; windows and metallic areas appear to transmit approximately equal amounts of sound energy.

Jha, S. K.↗

Sea-surface temperature and salinity mapping from remote microwave radiometric measurements of brightness temperature

A technique to measure remotely sea surface temperature and salinity was demonstrated with a dual frequency microwave radiometer system. Accuracies in temperature of 1 C and in salinity of part thousand for salinity greater than 5 parts per thousand were attained after correcting for the influence of extraterrestrial background radiation, atmospheric radiation and attenuation, sea-surface roughness, and antenna beamwidth. The radiometers, operating at 1.43 and 2.65 GHz, comprise a third-generation system using null balancing and feedback noise injection. Flight measurements from an aircraft at an altitude of 1.4 km over the lower Chesapeake Bay and coastal areas of the Atlantic Ocean resulted in contour maps of sea-surface temperature and salinity with a spatial resolution of 0.5 km.

Hans-Juergen, C. B.↗

Using Bit Errors To Diagnose Fiber-Optic Links

Technique for diagnosis of fiber-optic digital communication link in local-area network of computers based on measurement of bit-error rates. Variable optical attenuator inserted in optical fiber to vary power of received signal. Bit-error rate depends on ratio of peak signal power to root-mean-square noise in receiver. For optimum measurements, one selects bit-error rate between 10 to negative 8th power and 10 to negative 4th power. Greater rates result in low accuracy in determination of signal-to-noise ratios, while lesser rates require impractically long measurement times.

Bergman, L. A.↗

Vibrational testing of optical fiber connector joints

An experimental study was performed to determine the effects of vibration on the propagation of light through SMA- and ST-type fiber-optic connectors. A multimode, fiber-optic link was vibrated from 0 to 10,000 Hz at a constant peak acceleration along the connector transverse and longitudinal axes. All other environmental parameters were ambient. Transfer characteristics through the connection were examined as a function of vibrational frequency using both laser and light-emitting diode (LED) light to illuminate the system. Slight differences in operation between the SMA and ST connectors were observed with no appreciative attenuation as a result of vibration. Vibration did cause constant-amplitude input light to be modulated in the connector; however; the amplitude of vibration-induced noise was less than 3 standard deviations from the mean.

Sovie, Amy L.↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗

An attenuation integral digital imaging technique for the treatment portal verification of conventional and intensity-modulated radiotherapy

Purpose: To propose an attenuation integral digital imaging (AIDI) technique for the treatment portal verification of conventional and intensity-modulated radiotherapy (IMRT). Methods: In AIDI technique, an open in air fluence image I{sub o} and a patient fluence image I were acquired under the same exposure. Then after doing the dark field correction for both the I{sub o} and I, the AIDI image was simply calculated as log(I{sub o}/I), which is the attenuation integral along the ray path from the x-ray source to a detector pixel element. Theoretical analysis for the low contrast detection and the contrast to noise ratio (CNR) of AIDI was presented and compared to those for the fluence imaging. With AIDI, the variation of x-ray fluence and the variation of individual detector pixel's response can be automatically compensated without using the flood field correction. Results: The AIDI image for a contrast detail phantom demonstrated that it can efficiently suppress the background structures such as the couch and generate better visibility for low contrast objects with megavoltage x rays. The AIDI image acquired for a Catphan 500 phantom using a 60 deg. electronic dynamic wedge field also revealed more contrast disks than the fluence imaging did. Finally, AIDI for an IMRT field of a head/neck patient successfully displayed the anatomical structures underneath the treatment portal but not shown in fluence imaging. Conclusions: For IMRT and high degree wedge beams, direct imaging using them is difficult because their photon fluence is highly nonuniform. But AIDI can be used for the treatment portal verification of these beams.

60 APPLIED LIFE SCIENCES↗

Vibrational testing of optical fiber connector joints

An experimental study was performed to determine the effects of vibration on the propagation of light through SMA- and ST-type fiber-optic connectors. A multimode, fiber-optic link was vibrated from 0 to 10,000 Hz at a constant peak acceleration along the connector transverse and longitudinal axes. All other environmental parameters were ambient. Transfer characteristics through the connection were examined as a function of vibrational frequency using both laser and light-emitting diode (LED) light to illuminate the system. Slight differences in operation between the SMA and ST connectors were observed with no appreciative attenuation as a result of vibration. Vibration did cause the constant-amplitude input light to be modulated in the connector; however, the amplitude of vibration-induced noise was less than 3 standard deviations from the mean.

Sovie, Amy L.↗

Minimizing noise-temperature measurement errors

An analysis of noise-temperature measurement errors of low-noise amplifiers was performed. Results of this analysis can be used to optimize measurement schemes for minimum errors. For the cases evaluated, the effective noise temperature (Te) of a Ka-band maser can be measured most accurately by switching between an ambient and a 2-K cooled load without an isolation attenuator. A measurement accuracy of 0.3 K was obtained for this example.

Stelzried, C. T.↗

Acoustic Prediction State of the Art Assessment

The acoustic assessment task for both the Subsonic Fixed Wing and the Supersonic projects under NASA s Fundamental Aeronautics Program was designed to assess the current state-of-the-art in noise prediction capability and to establish baselines for gauging future progress. The documentation of our current capabilities included quantifying the differences between predictions of noise from computer codes and measurements of noise from experimental tests. Quantifying the accuracy of both the computed and experimental results further enhanced the credibility of the assessment. This presentation gives sample results from codes representative of NASA s capabilities in aircraft noise prediction both for systems and components. These include semi-empirical, statistical, analytical, and numerical codes. System level results are shown for both aircraft and engines. Component level results are shown for a landing gear prototype, for fan broadband noise, for jet noise from a subsonic round nozzle, and for propulsion airframe aeroacoustic interactions. Additional results are shown for modeling of the acoustic behavior of duct acoustic lining and the attenuation of sound in lined ducts with flow.

Dahl, Milo D.↗

Detection of p-mode Oscillations in HD 35833 with NEID and TESS

We report the results of observations of p-mode oscillations in the G0 subgiant star HD 35833 in both radial velocities and photometry with NEID and TESS, respectively. We achieve separate, robust detections of the oscillation signal with both instruments (radial velocity amplitude ARV = 1.11 ± 0.09 m s−1, photometric amplitude Aphot = 6.42 ± 0.60 ppm, frequency of maximum power nmax = 595.71  17.28 μHz, and mode spacing Δν = 36.65 ± 0.96 μHz) as well as a nondetection in a TESS sector concurrent with the NEID observations. These data shed light on our ability to mitigate the correlated noise impact of oscillations with radial velocities alone and on the robustness of commonly used asteroseismic scaling relations. The NEID data are used to validate models for the attenuation of oscillation signals for exposure times t max < n-1 , and we compare our results to predictions from theoretical scaling relations and find that the observed amplitudes are weaker than expected by >4σ, hinting at gaps in the underlying physical models.

Arvind F Gupta↗