Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

ACDC (Automated Campbell Diagram Code) [SWR-26-042]

This application provides a web-based graphical user interface to generating Campbell Diagrams and visualizing mode shapes for OpenFAST turbine models. Determining the aeroelastic stability and dynamic characteristics of wind turbines is a critical step in turbine design and analysis. Historically, extracting natural frequencies and mode shapes from OpenFAST—the industry-standard whole-turbine simulation code—has been a fragmented and tedious process. It required manual model configuration, command-line linearization execution, and complex post-processing via proprietary scripts to handle rotating-frame dynamics. To address these workflow bottlenecks, we present the Automated Campbell Diagram Code (ACDC), an open-source graphical software tool developed by the National Laboratory of the Rockies (NLR) under the DOE-funded Distributed Wind Aeroelastic Modeling (dWAM) project. ACDC streamlines the end-to-end linearization and stability analysis workflow into a single, intuitive cross-platform application. The software guides users through OpenFAST model configuration, definition of operating points, and the automated execution of steady-state trim and linearization simulations. Under the hood, ACDC automates the complex mathematical post-processing steps required for rotating systems, including Multi-Blade Coordinate (MBC) transformations, eigenanalysis, and advanced modal tracking utilizing the Modal Assurance Criterion (MAC) and spectral clustering. Finally, ACDC processes these results to automatically generate Campbell diagrams and features a robust 3D visualization engine to animate full-system mode shapes. By eliminating the reliance on external post-processing environments and manual data manipulation, ACDC significantly accelerates dynamic analysis and lowers the barrier to entry for wind energy researchers and engineers.

Summerville, Brent [National Laboratory of the Roc↗

Sensor fusion of pyrometry and acoustic measurements for localized keyhole pore identification in laser powder bed fusion

We report in-situ process monitoring as an aid to part qualification for laser powder-bed fusion (L-PBF) technology is a topic of increasing interest to the additive manufacturing community. In this work, airborne acoustic and inline pyrometry measurements were recorded simultaneously with the laser position. X-ray radiography imaging was used to spatio-temporally register keyhole pore locations to the pyrometry and acoustic signals, enabling binary labeling of data partitions based on pore formation. These labeled partitions were subsequently featurized using a highly comparative time-series analysis toolbox. Acoustic data was found to be much more effective than the pyrometry data for keyhole pore identification. However, when the information contained in both sensing modalities was combined in a sensor fusion strategy, the error rates of the top performing models were significantly reduced.

36 MATERIALS SCIENCE↗

Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of further calibration factors to be applied. The final accuracy of implantable MOSFETs when used for such kind of treatments was estimated to be within {+-}4%. Additional investigations using dose/fraction higher than 12 Gy, different beam configurations, and tracking systems could extend the present findings to other kind of treatments. MOSFET technology was proven to have high versatility in fast adaptation of existing detectors to new applications. It is plausible to expect a general feasibility of implantable MOSFET technology for in vivo dosimetry of the extracranial-targets treatments using the Cyberknife, provided each particular application will be validated by suitable both physical and clinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Magnetic Polarization Measurements of the Multi-modal Plasma Response to 3D fields in the EAST Tokamak

A multi-modal plasma response to applied non-axisymmetric fields has been found in EAST tokamak plasmas. Here, multi-modal means the radial and poloidal structure of an individually driven toroidal harmonic is not fixed. The signature of such a multi-modal response is the magnetic polarization (ratio of radial and poloidal components) of the plasma response field measured on the low field side device mid-plane. A difference in the 3D coil phasing (the relative phase of two coil arrays) dependencies between the two responses is observed in response to n=2 fields in the same plasma for which the n=1 responses are well synchronized. Neither the maximum radial nor the maximum poloidal field response to n=2 fields agrees with the best applied phasing for mitigating edge localized modes, suggesting that the edge plasma response is not a dominant component of either polarization. GPEC modeling reproduces the discrepant phasing dependences of the experimental measurements, and confirms the edge resonances are maximized by the coil phasing that mitigates ELMs in the experiments. The model confirms the measured plasma response is not dominated by resonant current drive from the external field. Instead, non-resonant contributions play a large role in the diagnostic signal for both toroidal harmonics n=1 and n=2. The analysis in this paper demonstrates the ability of 3D modeling to connect external magnetic sensor measurements to the internal plasma physics and accurately predict optimal applied 3D field configurations in multi-modal plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New approaches for metabolomics by mass spectrometry

Small molecules constitute a large part of the world around us, including fossil and some renewable energy sources. Solar energy harvested by plants and bacteria is converted into energy rich small molecules on a massive scale. Some of the worst contaminants of the environment and compounds of interest for national security also fall in the category of small molecules. The development of large scale metabolomic analysis methods lags behind the state of the art established for genomics and proteomics. This is commonly attributed to the diversity of molecular classes included in a metabolome. Unlike nucleic acids and proteins, metabolites do not have standard building blocks, and, as a result, their molecular properties exhibit a wide spectrum. This impedes the development of dedicated separation and spectroscopic methods. Mass spectrometry (MS) is a strong contender in the quest for a quantitative analytical tool with extensive metabolite coverage. Although various MS-based techniques are emerging for metabolomics, many of these approaches include extensive sample preparation that make large scale studies resource intensive and slow. New ionization methods are redefining the range of analytical problems that can be solved using MS. This project developed new approaches for the direct analysis of small molecules in unprocessed samples, as well as pushed the limits of ultratrace analysis in volume limited complex samples. The projects resulted in techniques that enabled metabolomics investigations with enhanced molecular coverage, as well as the study of cellular response to stimuli on a single cell level. Effectively individual cells became reaction vessels, where we followed the response of a complex biological system to external perturbation. We established two new analytical platforms for the direct study of metabolic changes in cells and tissues following external perturbation. For this purpose we developed a novel technique, laser ablation electrospray ionization (LAESI), for metabolite profiling of functioning cells and tissues. The technique was based on microscopic sampling of biological specimens by mid-infrared laser ablation followed by electrospray ionization of the plume and MS analysis. The two main shortcomings of this technique had been limited specificity due to the lack of a separation step, and limited molecular coverage, especially for nonpolar chemical species. To improve specificity and the coverage of the metabolome, we implemented the LAESI ion source on a mass spectrometer with ion mobility separation (IMS). In this system, the gas phase ions produced by the LAESI source were first sorted according to their collisional cross sections in a mobility cell. These separated ion packets were then subjected to MS analysis. By combining the atmospheric pressure ionization with IMS, we improved the metabolite coverage. Further enhancement of the non-polar metabolite coverage resulted from the combination of laser ablation with vacuum UV irradiation of the ablation plume. Our results indicated that this new ionization modality provided improved detection for neutral and non-polar compounds. Based on rapid progress in photonics, we had introduced another novel ion source that utilized the interaction of a laser pulse with silicon nanopost arrays (NAPA). In these nanophotonic ion sources, the structural features were commensurate with the wavelength of the laser light. The enhanced interaction resulted in high ion yields. This ultrasensitive analytical platform enabled the MS analysis of single yeast cells. We extended these NAPA studies from yeast to other microorganisms, including green algae (Chlamydomonas reinhardtii) that captured energy from sunlight on a massive scale. Combining cellular perturbations, e.g., through environmental changes, with the newly developed single cell analysis methods enabled us to follow dynamic changes induced in the cells. In effect, we were able to use individual cells as a “laboratory,” and approached the long-standing goal of establishing a “lab-in-a-cell.” Model systems for these studies included cells of cyanobacteria (Anabaena), yeast (Saccharomyces cerevisiae), green algae (C. reinhardtii) and Arabidopsis thaliana.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of coupled thermoacoustic modes: Noise and frequency spacing effects

Practical combustion systems consist of multiple thermoacoustic modes that are linearly stable or unstable at a wide range of frequencies. When coupled, the modal interactions are a strong function of the frequency spacing between them – having very significant implications on interpretation of linear stability or instability of modes from experimental data. Frequency spacing between the modes particularly influences the stability and existence of potential limit cycle solutions. In this paper, we extend earlier deterministic studies to include the effects of noise, studying how deterministic dynamics change with the addition of noise and the simultaneous impact of frequency spacing (i.e., closely, or widely spaced). Specifically, this paper characterizes three key effects of noise, which are (1) distribution of limit cycle amplitudes (“diffusion”), (2) shift in the average limit cycle amplitudes (“noise induced drift”), and (3) introduction of new bifurcations that are not present in the deterministic system. Key conclusions from this work are that in highly noisy practical environments, a deterministic/ low noise analysis will not be sufficient to explain even critical qualitative features of the system – such as existence of stable limit cycles or their amplitudes. Furthermore, the nature of noise-induced effects on nonlinear modal interactions can be fundamentally different for degenerate, closely spaced, and widely spaced modes.

42 ENGINEERING↗

A 10-Year Retrospective Review of a Nonrandomized Cohort of 458 Patients Undergoing Radical Radiotherapy or Cystectomy in Yorkshire, UK

Purpose: We have previously reported on the mortality, morbidity, and 5-year survival of 458 patients who underwent radical radiotherapy or surgery for invasive bladder cancer in Yorkshire from 1993 to 1996. We aim to present the 10-year outcomes of these patients and to reassess factors predicting survival. Methods and Materials: The Northern and Yorkshire Cancer Registry identified 458 patients whose cases were subjected to Kaplan-Meier all-cause survival analyses, and a retrospective casenote analysis was undertaken on 398 (87%) for univariate and multivariate Cox proportional hazards modeling. Additional proportional hazards regression modeling was used to assess the statistical significance of variables on overall survival. Results: The ratio of radiotherapy to cystectomy was 3:1. There was no significant difference in overall 10-year survival between those who underwent radiotherapy (22%) and radical cystectomy (24%). Univariate analyses suggested that female sex, performance status, hydronephrosis and clinical T stage, were associated with an inferior outcome at 10 years. Patient age, tumor grade, treatment delay, and caseload factors were not significant. Multivariate analysis models were created for 0-2 and 2-10 years after treatment. There were no significant differences in treatment for 0-2 years; however, after 2 years follow-up there was some evidence of increased survival for patients receiving surgery compared with radiotherapy (hazard ratio 0.66, 95% confidence interval: 0.44-1.01, p = 0.06). Conclusions: a 10-year minimum follow-up has rarely been reported after radical treatment for invasive bladder cancer. At 10 years, there was no statistical difference in all-cause survival between surgery and radiotherapy treatment modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Judging Criterion of Controlled Structures with Closely Spaced Natural Frequencies

The structures with closely spaced natural frequencies widely exist in civil engineering; however, the judging criterion of the density of closely spaced frequencies is in dispute. This paper suggests a judging criterion for structures with closely spaced natural frequencies based on the analysis on a controlled 2-DOF structure. The analysis results indicate that the optimal control gain of the structure with velocity feedback is dependent on the frequency density parameter of structure and the maximum attainable additional modal damping ratio is 1.72 times of the frequency density parameter when state feedback is applied. Based on a brief review on the previous researches, a judging criterion related the minimum frequency density parameter and the required mode damping ratio was proposed.

97 MATHEMATICS AND COMPUTING↗

Phonon transport properties of two-dimensional electride Ca 2 N—A first-principles study

We investigate phonon transport in dicalcium nitride (Ca 2 N), an electride with two-dimensional confined electron layers, using first-principles density functional theory and the phonon Boltzmann transport equation. The in-plane (κ[100]) and out-of-plane (κ[001]) lattice thermal conductivities at 300 K are found to be 11.72 W m -1 K -1 and 2.50 W m -1 K -1 , respectively. Spectral analysis of lattice thermal conductivity shows that ~85% of $κ_{[100]}$ and $κ_{[001]}$ is accumulated by phonons with frequencies less than 5.5 THz and 2.5 THz, respectively. Modal decomposition of lattice thermal conductivity further reveals that the optical phonons contribute to ~68% and ~55% of overall $κ_{[100]}$ and $κ_{[001]}$, respectively. Phonon dispersion suggests that the large optical phonon contribution is a result of low frequency optical phonons with high group velocities and the lack of phonon bandgap between the acoustic and optical phonon branches. We find that the optical phonons with frequencies below ~5.5 THz have similar three-phonon phase space and scattering rates as acoustic phonons. Comparison of the contributions from emission and absorption processes reveals that the three-phonon phase space and scattering rates of phonons—optical or acoustic—with frequencies below 5.5 THz are largely dominated by absorption processes. We conclude that the large contribution to lattice thermal conductivity by optical phonons is due to the presence of multiple low frequency optical phonon modes with high group velocities and similar phase space and scattering rates as the acoustic phonons. This study provides the frequency and temperature dependent lattice thermal conductivity and insights into phonon transport in Ca 2 N, both of which have important implications for the development of Ca 2 N based devices.

36 MATERIALS SCIENCE↗

Basin and Range Investigation for Developing Geothermal Energy: Exploration Data

This data package includes exploration material from the Basin & Range Investigation for Developing Geothermal Energy [in Hidden Systems] project (BRIDGE), which is part of a broader initiative to advance the exploration of hidden geothermal resources in the Basin & Range Province of the western U.S. Data modalities include a helicopter-borne time-domain electromagnetic survey, magnetotellurics, 2-meter temperature measurements, ground-based gravity and legacy aeromagnetic surveys, geochemistry, geologic mapping, LiDAR analysis, 3D models, associated geospatial data, and a bibliography of existing data and references utilized in prospect characterization and conceptual modeling. Key files are in CSV, Geosoft, and Geotools formats. Please refer to READMEs for dataset-specific information. Where applicable, acquisition data and inversion models for a particular prospect or area of interest are organized separately. This BRIDGE data package is the product of a collaboration led by Sandia National Laboratories with partners from Geologica Geothermal Group, Inc., the U.S. Navy Geothermal Program Office, and consultants Steven Sewell (Australis Geoscience Ltd) and William Cumming (Cumming Geoscience). The project's areas of interest (AOIs) are based off priority areas of interest in the southwestern portion of the Nevada Play Fairway map, distribution across tectonic provinces, accessibility, and the project team's extensive experience in the region. AOIs cover about a dozen basins that include unexplored prospects, partially explored prospects, and some developed analogue resources that provide validation cases. Many unexplored and partially explored prospects are on U.S. Department of Defense (DoD) land, though adjacent lands are included as well.

15 GEOTHERMAL ENERGY↗

Modal Field Reconstruction in Resonant Cavities in the Fundamental and Undermoded Frequency Regimes

Theory, simulations, and experiments are presented that demonstrate reconstruction of electromagnetic fields in a cavity from sparse probe measurements. Such techniques are often referred to as virtual sensing, allowing fields at unobserved locations to be predicted. These methods are appropriate for the fundamental and undermoded regimes, providing the ability to estimate fields (and shielding effectiveness) throughout an arbitrarily shaped cavity from a few judiciously spaced probes. A modal simulation method is implemented that allows the response of arbitrarily shaped cavities to be rapidly computed with respect to varying probe locations and slot parameters, enabling statistical analysis of probe placement on reconstruction performance. A cylindrical vessel with numerous probe holes is developed for experiments, referred to as Perforated Vessel 2 (PV2). Experiments are performed on the vessel with and without a steel box inside, where transmit power is delivered into the vessel either through probes (probe injection) or through slots using an external antenna (slot excitation). Simulations and experiments illustrate that when the number of probes is minimal (equal to the number of mode coefficients to be estimated at each frequency), probe placement is critical to avoid missed peaks and to have acceptable reconstruction error. Probe placement becomes less important as the number of probes is increased, but care is still required to avoid probe locations giving poor performance.

42 ENGINEERING↗

Explorer-II: Wireless Self-Powered Visual and NDE Robotic Inspection System for Live Gas Distribution Mains

Carnegie Mellon University (CMU) under contract from Department of Energy/National Energy Technology Laboratory (DoE/NETL) and co-funding from the Northeast Gas Association (NGA), has completed the overall system design, field-trial and Magnetic Flux Leakage (MFL) sensor evaluation program for the next-generation Explorer-II (X-II) live gas main Non-destructive Evaluation (NDE) and visual inspection robot platform. The design is based on the Explorer-I prototype which was built and field-tested under a prior (also DoE- and NGA co-funded) program, and served as the validation that self-powered robots under wireless control could access and navigate live natural gas distribution mains. The X-II system design ({approx}8 ft. and 66 lbs.) was heavily based on the X-I design, yet was substantially expanded to allow the addition of NDE sensor systems (while retaining its visual inspection capability), making it a modular system, and expanding its ability to operate at pressures up to 750 psig (high-pressure and unpiggable steel-pipe distribution mains). A new electronics architecture and on-board software kernel were added to again improve system performance. A locating sonde system was integrated to allow for absolute position-referencing during inspection (coupled with external differential GPS) and emergency-locating. The power system was upgraded to utilize lithium-based battery-cells for an increase in mission-time. The resulting robot-train system with CAD renderings of the individual modules. The system architecture now relies on a dual set of end camera-modules to house the 32-bit processors (Single-Board Computer or SBC) as well as the imaging and wireless (off-board) and CAN-based (on-board) communication hardware and software systems (as well as the sonde-coil and -electronics). The drive-module (2 ea.) are still responsible for bracing (and centering) to drive in push/pull fashion the robot train into and through the pipes and obstacles. The steering modules and their arrangement, still allow the robot to configure itself to perform any-angle (up to 90 deg) turns in any orientation (incl. vertical), and enable the live launching and recovery of the system using custom fittings and a (to be developed) launch-chamber/-tube. The battery modules are used to power the system, by providing power to the robot's bus. The support modules perform the functions of centration for the rest of the train as well as odometry pickups using incremental encoding schemes. The electronics architecture is based on a distributed (8-bit) microprocessor architecture (at least 1 in ea. module) communicating to a (one of two) 32-bit SBC, which manages all video-processing, posture and motion control as well as CAN and wireless communications. The operator controls the entire system from an off-board (laptop) controller, which is in constant wireless communication with the robot train in the pipe. The sensor modules collect data and forward it to the robot operator computer (via the CAN-wireless communications chain), who then transfers it to a dedicated NDE data-storage and post-processing computer for further (real-time or off-line) analysis. The prototype robot system was built and tested indoors and outdoors, outfitted with a Remote-Field Eddy Current (RFEC) sensor integrated as its main NDE sensor modality. An angled launcher, allowing for live launching and retrieval, was also built to suit custom angled launch-fittings from TDW. The prototype vehicle and launcher systems are shown. The complete system, including the in-pipe robot train, launcher, integrated NDE-sensor and real-time video and control console and NDE-data collection and -processing and real-time display, were demonstrated to all sponsors prior to proceeding into final field-trials--the individual components and setting for said acceptance demonstration are shown. The launcher-tube was also used to verify that the vehicle system is capable of operating in high-pressure environments, and is safely deployable using proper evacuating/purging techniques for operation in the potentially explosive natural gas environment. The test-setting and environment for safety-certification of the X-II robot platform and the launch and recovery procedures, is shown. Field-trials were successfully carried out in a live steel pipeline in Northwestern Pennsylvania. The robot was launched and recovered multiple times, travelling thousands of feet and communicating in real time with video and command-and-control (C&C) data under remote operator control from a laptop, with NDE sensor-data streaming to a second computer for storage, display and post-processing. Representative images of the activities and systems used in the week-long field-trial are shown. CMU also evaluated the ability of the X-II design to be able to integrate an MFL sensor, by adding additional drive-/battery-/steering- and support-modules to extend the X-II train.

03 NATURAL GAS↗

Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗

Propensity Score-based Comparison of Long-term Outcomes With 3-Dimensional Conformal Radiotherapy vs Intensity-Modulated Radiotherapy for Esophageal Cancer

Purpose: Although 3-dimensional conformal radiotherapy (3D-CRT) is the worldwide standard for the treatment of esophageal cancer, intensity modulated radiotherapy (IMRT) improves dose conformality and reduces the radiation exposure to normal tissues. We hypothesized that the dosimetric advantages of IMRT should translate to substantive benefits in clinical outcomes compared with 3D-CRT. Methods and Materials: An analysis was performed of 676 nonrandomized patients (3D-CRT, n=413; IMRT, n=263) with stage Ib-IVa (American Joint Committee on Cancer 2002) esophageal cancers treated with chemoradiotherapy at a single institution from 1998-2008. An inverse probability of treatment weighting and inclusion of propensity score (treatment probability) as a covariate were used to compare overall survival time, interval to local failure, and interval to distant metastasis, while accounting for the effects of other clinically relevant covariates. The propensity scores were estimated using logistic regression analysis. Results: A fitted multivariate inverse probability weighted-adjusted Cox model showed that the overall survival time was significantly associated with several well-known prognostic factors, along with the treatment modality (IMRT vs 3D-CRT, hazard ratio 0.72, P<.001). Compared with IMRT, 3D-CRT patients had a significantly greater risk of dying (72.6% vs 52.9%, inverse probability of treatment weighting, log-rank test, P<.0001) and of locoregional recurrence (P=.0038). No difference was seen in cancer-specific mortality (Gray's test, P=.86) or distant metastasis (P=.99) between the 2 groups. An increased cumulative incidence of cardiac death was seen in the 3D-CRT group (P=.049), but most deaths were undocumented (5-year estimate, 11.7% in 3D-CRT vs 5.4% in IMRT group, Gray's test, P=.0029). Conclusions: Overall survival, locoregional control, and noncancer-related death were significantly better after IMRT than after 3D-CRT. Although these results need confirmation, IMRT should be considered for the treatment of esophageal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A validated tumor control probability model based on a meta-analysis of low, intermediate, and high-risk prostate cancer patients treated by photon, proton, or carbon-ion radiotherapy

Purpose: A fully heterogeneous population averaged mechanistic tumor control probability (TCP) model is appropriate for the analysis of external beam radiotherapy (EBRT). This has been accomplished for EBRT photon treatment of intermediate-risk prostate cancer. Extending the TCP model for low and high-risk patients would be beneficial in terms of overall decision making. Furthermore, different radiation treatment modalities such as protons and carbon-ions are becoming increasingly available. Consequently, there is a need for a complete TCP model. Methods: A TCP model was fitted and validated to a primary endpoint of 5-year biological no evidence of disease clinical outcome data obtained from a review of the literature for low, intermediate, and high-risk prostate cancer patients (5218 patients fitted, 1088 patients validated), treated by photons, protons, or carbon-ions. The review followed the preferred reporting item for systematic reviews and meta-analyses statement. Treatment regimens include standard fractionation and hypofractionation treatments. Residual analysis and goodness of fit statistics were applied. Results: The TCP model achieves a good level of fit overall, linear regression results in a p-value of <0.000 01 with an adjusted-weighted-R{sup 2} value of 0.77 and a weighted root mean squared error (wRMSE) of 1.2%, to the fitted clinical outcome data. Validation of the model utilizing three independent datasets obtained from the literature resulted in an adjusted-weighted-R{sup 2} value of 0.78 and a wRMSE of less than 1.8%, to the validation clinical outcome data. The weighted mean absolute residual across the entire dataset is found to be 5.4%. Conclusions: This TCP model fitted and validated to clinical outcome data, appears to be an appropriate model for the inclusion of all clinical prostate cancer risk categories, and allows evaluation of current EBRT modalities with regard to tumor control prediction.

61 RADIATION PROTECTION AND DOSIMETRY↗