Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen↗

Fusing Quantitative-Phase Imaging with Airy Light- Sheet Microscopy

We report the integration of quantitative-phase imaging (QPI) with light-sheet (LS) fluorescent microscopy on to a standard inverted microscope that retains compatibility with microfluidics. QPI enables label-free imaging and number-density quantification of single cells and their organelles. Conversely, LS yields considerable speed and phototoxicity gains in quantifying the 4D dynamics of gene-encoded fluorescent biomarkers. We will detail the system design that relied on spatial light interferometry for QPI and an accelerating Airy- beam light-sheet for fluorescence, its performance, as well as results of a representative multivariate imaging analysis of single-cell metabolism.

imaging, lattice light sheet, Yarrowia lipolytica,↗

Separation of nanoparticles via acoustofluidic flow relocation

The present disclosure describes a method of separating particles using a combination of acoustophoresis and acoustic fluid relocation. The disclosure also describes a microfluidic device that can be used to separate particles using a combination of acoustophoresis and acoustic fluid relocation. The disclosure describes methods of separating nanoparticles, microparticles, nanoparticles from microparticles, and micron-sized particles from sub-micron-sized particles.

Piyasena, Menake E.↗

Automated microbial detection and quantification

A method for automated microbial detection includes collecting air particles into a solid-state sampler, the air particles including microbes, charging the air particles using a plasma field generated by propulsion electrodes, focusing the charged air particles toward a sample well of a microfluidic testing cartridge, tagging the charged air particles with a fluorescence marker, and detecting a quantity of the microbes using a fluorescence detector.

Gilbert, James H.↗

Spectroscopy imaging and analysis of live cells

Disclosed herein are systems, methods, systems and devices for measurement and visualization of chemical dynamics in living cells or tissues for diagnostic pathology. Devices can be open- or closed-channel microfluidic membrane devices for long-term IR spectroscopy of live adherent cells and ultimately for rapidly identifying time-dependent spectral features indicative of chemical abnormality in individual cells.

Holman, Hoi-Ying N.↗

Partially degradable fibers and microvascular materials formed from the fibers

A partially degradable polymeric fiber includes a thermally degradable polymeric core and a coating surrounding at least a portion of the core. The thermally degradable polymeric core includes a polymeric matrix including a poly(hydroxy-alkanoate), and a metal selected from the group consisting of an alkali earth metal and a transition metal, in the core polymeric matrix. The concentration of the metal in the polymeric matrix is at least 0.1 wt %. The partially degradable polymeric fiber may be used to form a microvascular system containing one or more microfluidic channels.

Dong, Hefei↗

Wireless optofluidic systems for programmable in vivo pharmacology and optogenetics

Provided are implantable, injectable and/or surface mounted biomedical devices and related methods for interfacing with a target tissue. The devices have a substrate, one or more microfluidic channels embedded in or supported by the substrate and a fluid actuator in operational communication with one or more reservoirs and responsive to a wireless control signal. The components of the device are specially configured and packaged to be ultra-thin and mechanically compliant. In some embodiments, the devices are self-powered and fully implantable. The devices can be shaped to provide injection in a minimally invasive manner, thereby avoiding unnecessary tissue damage and providing a platform for long-term implantation for interfacing with biological tissue.

Rogers, John A.↗

Parallelized multiple nozzle system and method to produce layered droplets and fibers for microencapsulation

The present disclosure relates to a nozzle system for use in a microfluidic production application for producing at least one of particles, capsules or fibers. The system has a main body portion having a compressed fluid inlet and a core fluid inlet, and a plurality of parallel arranged core fluid nozzles that receive the core fluid and create a plurality of core fluid streams. At least one compressed fluid inlet associated with the main body channels compressed fluid to areas adjacent ends of the core fluid nozzles. An apertured plate having a plurality of apertures is arranged near the ends of the core fluid nozzles, with each aperture being uniquely associated with a single one of the core fluid nozzles. The compressed fluid acts on the core fluid streams exiting the core fluid nozzles to help create, with the apertures, at least one of core fluid droplets or core fluid fibers from the core fluid streams.

Ye, Congwang↗

Picoliter droplet sample processing and deposition for mass spectrometry

Disclosed herein include systems, devices, and methods for droplet deposition for mass spectrometry. In some embodiments, a microfluidic device comprising wells is reversibly sealed to a mass spectrometry surface and used to deposit contents of droplets (e.g., enzymes and substrates), or products thereof, onto the mass spectrometry surface. The contents of droplets can be analyzed by laser desorption/ionization to, for example, identify a substrate of an enzyme or an enzyme capable of catalyzing a substrate to a product.

Ha, Noel↗

Studying Cerium Oxide and Uranium Oxide Using Particle Attached Microelectrodes

The conference proceeding presents results of CeO2 and UO2 particles as microelectrodes enclosed in the SALVI E-cell developed in Dr. Yu's lab. These microfluidic cells can be used to study spent fuel materials in minute amount. They offer a flexible and economic way to understand spent fuel oxidation and dissolution in waste storage conditions.

Son, Jiyoung↗

Microscale device and method for purification of radiopharmaceuticals

A microfluidic chip device for the purification of radiochemical compounds includes a chip having an injection channel and intersecting branch channels with a plurality of valves are located along the injection channel and branch channels and configured to retain a plug of solution containing the radiochemical compound. The chip further includes a serpentine channel segment (for separation) coupled to the output of the injection channel. A high voltage power source advances the plug of solution through the purification region and into the downstream fraction collection channel. The chip includes a downstream fraction collection channel coupled to the serpentine channel segment and having an optical and radiation detection regions. One or more branch fraction channels intersect with the fraction collection channel and include valves located therein so that the radiochemical compound that is detected using a radiation detector is directed into the desired branch fraction channel for subsequent use.

Van Dam, R. Michael↗

Integrated imaging assembly and method for using

Certain disclosed embodiments concern an integrated imaging system that combined light-sheet microscopy, which enables considerable speed and phototoxicity gains, with quantitative-phase imaging. A method for using such imaging systems also is disclosed. In an exemplary embodiment, an integrated imaging system was used for multivariate investigation of live-cells in microfluidics.

Vasdekis, Andreas E.↗

Soft X‐Ray Absorption Spectroscopy With a Flat Liquid Jet in Vacuum Using a Table‐Top Laser‐Induced Plasma Source

ABSTRACT In this work, we demonstrate the integration of a flat liquid jet sample delivery system into a compact soft x‐ray absorption spectrometer using a table‐top laser‐induced plasma source. A high‐speed flat liquid sheet is formed by the collision of two cylindrical jets. This micrometer‐thin lamella can ideally be utilized for transmission‐mode soft x‐ray absorption spectroscopy using krypton plasma emission. Detailed analysis of the jet's thickness profile is achieved applying Lambert–Beer's law. Measurements on water, focusing on the oxygen K‐edge, reveal a lamella thickness profile ranging from 500 nm to 1 μm over a length of 3.8 mm. Additionally, we have investigated aqueous solutions of iron salts, capturing near edge x‐ray absorption fine structure spectra over a broad spectral range from the nitrogen K‐edge to the iron L‐edge. Focused analysis on iron species in aqueous solutions enabled us to distinguish quantitatively between the oxidation states of Fe 2+ and Fe 3+ at the iron L‐edge. Our results are compared with measurements obtained under similar conditions at a synchrotron.

Holburg, Jonathan [Department Optics/Short Wavelen↗

Wettability and capillary effects: Dynamics of pinch-off in unconstricted straight capillary tubes

We study the interfacial evolution of immiscible two-phase flow within a capillary tube in the partial wetting regime using direct numerical simulation. We investigate the flow patterns resulting from the displacement of a more viscous fluid by a less viscous one under a wide range of wettability conditions. We find that beyond a wettability dependent critical capillary number, a uniform displacement by a less viscous fluid can transition into a growing finger that eventually breaks up into discrete blobs by a series of pinch-off events for both wetting and non-wetting contact angles. This study validates previous experimental observations of pinch-off for wetting contact angles and extends those to non-wetting contact angles. We find that the blob length increases with the capillary number. We observe that the time between consecutive pinch-off events decreases with the capillary number and is greater for more wetting conditions in the displaced phase. Here, we further show that the blob separation distance as a function of the difference between the inlet velocity and the contact line speed collapses into two monotonically decreasing curves for wetting and non-wetting contact angles. For the phase separation in the form of pinch-off, this work provides a quantitative study of the emerging length and time scales and their dependence on the wettability conditions, capillary effects, and viscous forces.

42 ENGINEERING↗

CsPbI 3 Nanocrystals Go with the Flow: From Formation Mechanism to Continuous Nanomanufacturing

Despite the groundbreaking advancements in the synthesis of inorganic lead halide perovskite (LHP) nanocrystals (NCs), stimulated from their intriguing size-, composition-, and morphology-dependent optical and optoelectronic properties, their formation mechanism through the hot-injection (HI) synthetic route is not well-understood. Here in this work, for the first time, in-flow HI synthesis of cesium lead iodide (CsPbI 3 ) NCs is introduced and a comprehensive understanding of the interdependent competing reaction parameters controlling the NC morphology (nanocube vs nanoplatelet) and properties is provided. Utilizing the developed flow synthesis strategy, a change in the CsPbI 3 NC formation mechanism at temperatures higher than 150 °C, resulting in different CsPbI 3 morphologies is revealed. Through comparison of the flow- versus flask-based synthesis, deficiencies of batch reactors in reproducible and scalable synthesis of CsPbI 3 NCs with fast formation kinetics are demonstrated. The developed modular flow chemistry route provides a new frontier for high-temperature studies of solution-processed LHP NCs and enables their consistent and reliable continuous nanomanufacturing for next-generation energy technologies.

36 MATERIALS SCIENCE↗

Volumetric Additive Manufacturing of Dormant Catalytic Chemistries to Generate Silicone Micro‐ and Millifluidic Devices and Instant Molds

Tomographic volumetric additive manufacturing (T‐VAM) rapidly prints solid objects within minutes, accessing photochemistries that are traditionally challenging for layer‐based additive manufacturing methods. This includes high‐viscosity materials, air‐free chemistries, and solid‐state systems. Catalytic chemistries are appealing as a pathway to engineering advanced materials, including tough thermosets, silicone elastomers, and complex block copolymers. However, photoactivated dormant catalytic chemistries, where the catalyst irreversibly activates upon exposure to light, are incompatible with typical tomographic VAM approaches. To address this limitation, a zero‐dose optimization strategy is devised to preserve dormant catalysts in desired regions by keeping them unexposed to light. VAM printed micro‐ and millifluidic devices and instant molds are successfully produced within minutes in silicones polymerized using photoactivated dormant platinum photohydrosilylation catalysts. The printed channels are programmed to be 500 and 2500 µm for the micro‐ and millifluidic devices, and print fidelity is assessed by X‐ray computed tomography. This work demonstrates the potential of zero‐dose optimization to expand the range of chemistries accessible for VAM, enabling the rapid fabrication of complex devices.

Additive Manufacturing↗

Solution‐Like Water Transport Across Molecular to Macroscopic Length Scales in Crosslinked Poly(Ethylene Glycol Diacrylate) Networks With Tailored Sidechains

Poly(ethylene glycol) (PEG)‐based materials, like PEG‐diacrylate (PEGDA), are prized for their hydrophilic, inert properties, and leveraged in hydrogels and as membrane mimics. While network chemistry is often tuned for selective transport and antifouling, fundamental understanding of water dynamics at the network surface and the impact on bulk transport is limited. We utilize Overhauser dynamic nuclear polarization (ODNP) to measure nanoscale water diffusivity near a tethered spin label at the water‐polymer surface and compare it to bulk water diffusivity from pulsed field gradient (PFG) NMR. Via active ester chemistry, spin labels and varied sidechain chemistries are introduced, modulating network hydrophilicity. Tuning network hydration through crosslinker content and functional groups further impacts water diffusivity. Results show rapid nanoscale water transport at the polymer surface, reflecting network volumetric water content, with further modulation by sidechain functionality. These findings demonstrate PEGDA's utility as a membrane mimic and the critical impact of network chemistry on water transport.

hydrogels↗

Real-time gross actinide monitoring in extreme (10 6 :1) beta-gamma background fluid streams using mini-ATMFDs

Real-time, trace alpha activity monitoring in extreme mixed radiation fields is a well-known challenge in fission product-rich streams containing mixtures of beta-gamma-alpha radiation-emitting isotopes, arising due to the extreme 10 6 :1 ratio of background beta-gamma vs. alpha radiation activity levels. This paper presents results from a novel approach to addressing this challenge, based on Tensioned Metastable Fluid Detector (TMFD) sensing technology. An acoustically driven technique was developed and tested at Purdue University (using dissolved Rn-Po and U-chain alpha emitters), and validated (with dissolved Pu) at Savannah River National Laboratory for real-time monitoring of alpha activity in the 100–10,000 dpm/mL range.

Environmental Monitoring↗