Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Novel preparation of an ancient ceramic pigment BaCuSi4O10 and its performance investigation

Highlights: • The BaCuSi{sub 4}O{sub 10} (Chinese blue) was prepared firstly by coprecipitation and hydrothermal process at 180 °C for 20 h, and then sintered at 800 °C, resulting in pigment with superior performance. • The as-prepared pigment possesses bright blue coloration, preferable flower-like mesoporous microspheres morphology and qualified purity. • This novel process could fabricate the BaCuSi{sub 4}O{sub 10} pigment with broadband optical absorption and better emission in the near-infrared region. • This novel process decreases the calcination temperature compared with the traditional solid state method and also lowers the hydrothermal temperature and time compared with only a sole hydrothermal process. - Abstract: The BaCuSi{sub 4}O{sub 10} (Chinese blue) was prepared by coprecipitation and hydrothermal process at 180 °C for 20 h prior to sintering at 800 °C with a final pigment of superior performance. The crystalline configuration and microstructure of the product were characterized by XRD, FTIR, SEM and TEM. The electronic structure and the valence situation were determined by XPS. The coloration was studied with colorimeter. The absorption and the luminescence properties were examined with an UV−VIS-NIR spectrometer and a spectrofluorimeter, respectively. The results show that the BaCuSi{sub 4}O{sub 10} pigment prepared by this combined fabrication process possesses flower-like mesoporous microspheres morphology, better crystallization, clear coloration and rather qualified purity. The as-prepared BaCuSi{sub 4}O{sub 10} pigment also shows well optical property with broadband absorption and better emission in the 800–1200 nm range. Compared with traditional solid state fabrication or only sole hydrothermal process, this novel process can also reduce hydrothermal temperature and time, and decrease calcination temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Morphologies and magnetism of AxB1-xFe2O4 self-assembled nanospheres

Highlights: • A modified solvothermal method are successfully applied to prepare bimetallic ferrite microspheres. • The replaced ions coexist in same spinel lattice and cause its distortion. • The morphologies and magnetic properties are affected by type and content of ions. • As-prepared samples belong to paramagnetic materials with low coercivity. - Abstract: A series of A{sub x}B{sub 1-x}Fe{sub 2}O{sub 4} (x = 0.05–0.50) (A, B as Zn{sup 2+}, Ni{sup 2+}, Co{sup 2+}) micro-nanospheres were prepared using a facile one-pot solvothermal method. All products are spinel structures with grain sizes of around 11–15 nm as characterised by using XRD. SEM and TEM images show that Ni{sub x}Zn{sub 1-x}Fe{sub 2}O{sub 4} (x = 0.05–0.50) are microspheres self-assembled by nanoparticles with an average diameter of 200–300 nm, but the sizes of Ni{sub x}Co{sub 1-x}FeO{sub 4} (x = 0.10–0.50) and Zn{sub x}Co{sub 1-x}Fe{sub 2}O{sub 4} (x = 0.10–0.50) micro-nanospheres increase from 20 nm to 200 nm with increasing amounts of Ni{sup 2+} and Zn{sup 2+}. As-prepared A{sub x}B{sub 1-x}Fe{sub 2}O{sub 4} samples are paramagnetic materials with coercivities of no more than 177.5 Oe. The morphologies and magnetism of A{sub x}B{sub 1-x}Fe{sub 2}O{sub 4} could be adjusted by changing the amount of A{sup 2+} and B{sup 2+}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fabrication, mechanism, formic acid−tuned degradation and photocatalytic hydrogen production of novel modified ZnO spheres by L−TA−DMF assisted hydrothermal method

Highlights: • Many novel ZnO microspheres and building blocks were obtained. • It is first time that DMF and TA were used to fabricate ZnO simultaneously. • Five visible emissions are generated simultaneously and their PL intensities are tunable. • Formic acid induced photocatalytic efficiency was obtained. The H{sub 2} generation rate of S6 is 4.15 mL h{sup −1} g{sup −1} under simulated sunlight irradiation. • Photocatalytic mechanism and self-assembly modes were proposed. - Abstract: Many ZnO microspheres were fabricated by hydrothermal method using l−TA and DMF as double capping agents. These spheres possess many novel nanostructures and exhibit unique and flexible self−assemblies and building units. For example, diverse pattern−like spheres, core/shell spheres, and semispheres were obtained. FTIR spectra of S1−S9 show TA and HCOOH modified ZnO spheres, which agree with those of XPS analysis. PL spectra show that violet, blue, green, yellow and orange emissions generated simultaneously can be tuned. E{sub g} and ε are influenced by c. TA and DMF lead to diverse and novel ZnO growth, while DMF can tune the number of surface active sites of exposed (002) facet of ZnO, which determines final photocatalytic efficiency. TOC results show most of MB are mineralized rather than being partially degraded. The photocatalytic H{sub 2} generation rate is 4.15 ml h{sup −1}g{sup −1} under simulated sunlight irradiation. In addition, DMF−induced photocatalytic mechanisms and two self−assemblies were proposed.

36 MATERIALS SCIENCE↗

Superhydrophobic anti-ultraviolet films by doctor blade coating

This article reports a scalable technology for fabricating polymer films with excellent water-repelling and anti-ultraviolet properties. A roll-to-roll compatible doctor blade coating technology is utilized to prepare silica colloidal crystal-polymer composites. The silica microspheres can then be selectively removed to create flexible self-standing macroporous polymer films with crystalline arrays of pores. The void sizes are controlled by tuning the duration of a reactive ion etching process prior to the removal of the templating silica microspheres. After surface modification, superhydrophobic surface can be achieved. This study further demonstrates that the as-prepared transparent porous films with 200 nm of pores exhibit diffraction of ultraviolet lights originated from the Bragg's diffractive of light from the three-dimensional highly ordered air cavities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiative rate modification in CdSe quantum dot-coated microcavity

Whispering gallery modes (WGMs) of the microparticles with spherical or cylindrical symmetry have exceptionally high quality factors and small mode volume. Quantum dots (QDs) are zero dimensional systems with variable band gap as well as luminescent properties with applications in photonics. In this paper, the WGMs have been observed in the luminescence spectra of CdSe QD-coated single silica microspheres. Theoretical estimations of variation of resonance frequency, electric field, and Q-values have been done for a multilayer coating of QDs on silica microspheres. Observed WGMs have been identified for their mode number and polarization using Mie theory. Broadening of modes due to material absorption has been observed. Splitting of WGMs has also been observed due to coherent coupling of counter propagating waves in the microcavity due to the presence of QDs. At room temperature, the time-resolved study indicates the modification of the radiative rate due to coupling of WGMs of the microcavity-QD hybrid system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Increase in the resolution of the method of surface nanostructuring by femtosecond-laser impact through a layer of colloidal microparticles

It is experimentally demonstrated that by converting a few percent of the fundamental frequency pulse energy into the second harmonic one can obtain surface structures using dielectric microspheres with the dimension of the order of the second harmonic wavelength. Structuring by means of the second harmonic solely requires a significantly greater energy density in the pulse than using bichromatic irradiation. It is impossible to obtain structures using only the fundamental frequency radiation pulses, because radiation at the fundamental frequency is not focused by the system of microspheres. Therefore, the use of bichromatic pulses allows an essential increase in the structure recording density. Theoretical calculations demonstrating the possibility of further improvement of the structure recording density by using nonspherical microlenses of a smaller size made of a material with a higher refractive index are presented. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and numerical simulation of spherical microresonators based on SiO{sub 2} – GeO{sub 2} germanosilicate glasses for generation of optical frequency combs

We propose and theoretically investigate the possibility of using spherical, whispering gallery mode microresonators based on germanosilicate glasses with different GeO{sub 2} contents for generating optical frequency combs in the dissipative soliton regime under pumping at a wavelength of 1.55 or 2 μm. The dispersion and nonlinearity of microspheres of different radii are calculated and analysed, and their optimal characteristics and the expected parameters of the output radiation are determined. It is shown that the spectral widths of optical frequency combs formed in 0.8SiO{sub 2} – 0.2GeO{sub 2} and GeO{sub 2} glass microspheres pumped at λ = 1.55 and 2 μm can be ∼200 and ∼300 nm, respectively. In these cases, in addition to the dissipative soliton with a duration of ∼100 fs, the generation of dispersive waves is also observed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transparent Conductive Adhesives for Tandem Solar Cells

Methods of making silicon based tandem cells include wafer bonding, depositing absorber layers on the surface, and mechanical stacking. Of these, mechanically stacking after growth retains the individual cell quality during production, but typically requires a four-terminal device. We present a transparent conductive adhesive (TCA) interlayer, designed for transparency in wavelengths that Si absorbs, conductivity for out-of-plane conductivity between cells, and adhesive strength, enabling two-terminal stacked tandems. The developed TCA material is a polymer-particle blend of common transparent adhesives and metal-coated flexible microspheres, capable of bridging micro-scale gaps between uneven/textured surfaces. At 10% microsphere coverage, experimental and theoretical series resistance is compatible with high-efficiency tandem cells on silicon.

14 SOLAR ENERGY↗

On0Line Fuel Failure Monitor for Fuel Testing and Monitoring of Gas Cooled Very High Temperature Reactor

IVery High Temperature Reactors (VHTR) utilize the TRISO microsphere as the fundamental fuel unit in the core. The TRISO microsphere (~ 1- mm diameter) is composed of a UO2 kernel surrounded by a porous pyrolytic graphite buffer, an inner pyrolytic graphite layer, a silicon carbide (SiC) coating, and an outer pyrolytic graphite layer. The U-235 enrichment of the fuel is expected to range from 4% – 10% (higher enrichments are also being considered). The layer/coating system that surrounds the UO2 kernel acts as the containment and main barrier against the environmental release of radioactivity. To understand better the behavior of this fuel under in-core conditions (e.g., high temperature, intense fast neutron flux, etc.), the US Department of Energy (DOE) is launching a fuel testing program that will take place at the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL). During this project North Carolina State University (NCSU) researchers will collaborate with INL staff for establishing an optimized system for fuel monitoring for the ATR tests. In addition, it is expected that the developed system and methods will be of general use for fuel failure monitoring in gas cooled VHTRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Colloid Mobilization and Porous Media Permeability Changes by Dynamic Stress Stimulations

Laboratory experiments on porous rock cores have shown that seismic-band (100 Hz or less) mechanical stress/strain cycling of the rock matrix can mobilize sub-pore-size particles (colloids) trapped in the pore space and allow them to be expelled during steady-state water flow. This coupling of dynamic stress to colloid mobility is a potential key mechanism whereby seismic waves may alter formation permeability and porous mass transport in Earth's crust. Experiments where colloid suspensions were injected into Fontainebleau sandstone cores demonstrated that colloid size and the ionic strength of the suspending fluid are major parameters that will control the ability of the colloids to attach to pore walls or to form particle bridges at pore throats. Both effects can lead to significant changes in permeability. A unique core-holder apparatus that applies low-frequency mechanical stress/strain to 2.54-cm-diameter porous rock samples during constant-rate fluid flow was used for those experiments. Microsphere injection caused the core's permeability to decline due to colloid bridging at pore throats. It was found that dynamic stress at 25 to 50 Hz mobilized these trapped colloids mainly when the ionic strength is low, and thereby partially restored the permeability of the sample. These earlier experiments on natural rocks were difficult to interpret in terms of how the colloids distributed themselves throughout the heterogeneous pore space and what interactions were occurring between the colloids and the solid matrix. Observed permeability changes appeared to be confined to the first 5-10 cm of the rock where the colloids were injected, yet significant transport of colloids was observed along the entire length of the sample. The 'natural rock' system is too complex geometrically at the pore scale to allow quantification of mass transport properties along its entire length. To remedy this problem, new colloid transport experiments were performed with a synthetic glass-bead pack. Unconsolidated 1-mm-diameter borosilicate beads were packed into a confining sleeve to a length of 30 cm. Sufficient radial and axial confinement pressures were applied to the sleeve to create a fluid seal and to introduce rigidity to the sample. Suspensions of 2-um polystyrene micro spheres in deionized water were injected into the bead pack while maintaining constant flow through the sample. Sample permeability and effluent microsphere production were measured before, during, and after low-frequency stress cycling, as in the previous experiments on rocks. Results of these dynamic stress mobilization experiments will be presented.

54 ENVIRONMENTAL SCIENCES↗

FABRICATION PROCESS AND PRODUCT QUALITY IMPROVEMENTS IN ADVANCED GAS REACTOR UCO KERNELS

A major element of the Advanced Gas Reactor (AGR) program is developing fuel fabrication processes to produce high quality uranium-containing kernels, TRISO-coated particles and fuel compacts needed for planned irradiation tests. The goals of the AGR program also include developing the fabrication technology to mass produce this fuel at low cost. Kernels for the first AGR test (“AGR-1) consisted of uranium oxycarbide (UCO) microspheres that werre produced by an internal gelation process followed by high temperature steps tot convert the UO3 + C “green” microspheres to first UO2 + C and then UO2 + UCx. The high temperature steps also densified the kernels. Babcock and Wilcox (B&W) fabricated UCO kernels for the AGR-1 irradiation experiment, which went into the Advance Test Reactor (ATR) at Idaho National Laboratory in December 2006. An evaluation of the kernel process following AGR-1 kernel production led to several recommendations to improve the fabrication process. These recommendations included testing alternative methods of dispersing carbon during broth preparation, evaluating the method of broth mixing, optimizing the broth chemistry, optimizing sintering conditions, and demonstrating fabrication of larger diameter UCO kernels needed for the second AGR irradiation test. Based on these recommendations and requirements, a test program was defined and performed. Certain portions of the test program were performed by Oak Ridge National Laboratory (ORNL), while tests at larger scale were performed by B&W. The tests at B&W have demonstrated improvements in both kernel properties and process operation. Changes in the form of carbon black used and the method of mixing the carbon prior to forming kernels led to improvements in the phase distribution in the sintered kernels, greater consistency in kernel properties, a reduction in forming run time, and simplifications to the forming process. Process parameter variation tests in both forming and sintering steps led to an increased understanding of the acceptable ranges for process parameters and additional reduction in required operating times. Another result of this test program was to double the kernel production rate. Following the development tests, approximately 40 kg of natural uranium UCO kernels have been produced for use in coater scale up tests, and approximately 10 kg of low enriched uranium UCO kernels for use in the AGR-2 experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rational Design of Hierarchically Open-Porous Spherical Hybrid Architectures for Lithium Ion Batteries

Controlling the internal microstructure and overall morphology of building blocks used to form hybrid materials is crucial for the realization of deterministically designed architectures with desirable properties. Here, we demonstrate an integrative spray-frozen (SF) assembly for forming hierarchically structured open-porous microspheres (hpMSs) composed of Fe 3 O 4 and reduced graphene oxide (rGO). The SF process drives the formation of a radially-aligned microstructure within the sprayed colloidal droplets and also controls the overall microsphere morphology. The Fe 3 O 4 /rGO hpMSs contain interconnected open-pores and spherical morphology, which, when used as a lithium-ion battery anode, enables then to provide gravimetric and volumetric capacities of 1069.7 mAh g -1 and 686.7 mAh cm -3 , much greater than those of samples with similar composition and different morphologies. The hpMSs have good rate and cycling performances, retaining 78.5% from 100 to 1000 mA g -1 and 74.6% over 300 cycles. Using in-situ synchrotron x-ray absorption spectroscopy, the reaction pathway and phase evolution of the hpMSs are monitored observing the very small domain size and highly disordered nature of Fe x O y . Here, the reduced capacity fading relative to other conversion systems is due to the good electrical contact between the pulverized Fe x O y particles and rGO, the overall structural integrity of the hpMSs, and interconnected openporosity.

25 ENERGY STORAGE↗

N-butyl Cyanoacrylate Glue Embolization of Arterial Networks to Facilitate Hepatic Arterial Skeletonization before Radioembolization

Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identify subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prophylactic Temporary Occlusion of the Cystic Artery Using a Fibered Detachable Coil During {sup 90}Y Radioembolization

PurposeTo address the feasibility of prophylactic temporary occlusion of the cystic artery using a detachable coil during {sup 90}Y radioembolization.Materials and MethodsFrom January 2012 to October 2016, nine patients underwent temporary occlusion of the cystic artery during {sup 90}Y radioembolization. Based on the planning hepatic angiography, a detachable coil was deployed into the cystic artery, which arose from a more distal level (e.g., right anterior hepatic artery) than its usual origin, but the proximal 1 cm was left inside the microcatheter. {sup 90}Y microspheres were infused proximal to the cystic artery where the 99mTc-MAA had been infused, and then the coil was retrieved. Afterward, the patients underwent PET/CT imaging. Medical records were reviewed, and the differences in the uptake of 99mTc-MAA and {sup 90}Y microspheres in the gallbladder were evaluated using Wilcoxon’s signed-rank test.ResultsTemporary placement of a detachable coil was feasible in all cases. On the angiograms obtained after detachable coil placement, the distal cystic artery and gallbladder were partially identifiable in eight of the nine (88.8%) patients, but fully restored after the removal of the coils in all cases. The proportional uptake of 99mTc-MAA (mean, 4.35%) and {sup 90}Y (mean, 0.90%) in the gallbladder was significantly different due to the temporary occlusion of the cystic artery (p = 0.004). No clinical complications were identified for three months after the procedure.ConclusionTemporary occlusion of the cystic artery using a detachable coil appeared to be feasible and effective in reducing {sup 90}Y uptake in the gallbladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation Between Magnetization and Particle Size of CdS Nanostructures by Solvothermal Method

Micro- and nano-structures of CdS including microrods, nanoparticles, nanorods, microspheres, and nanosheets were prepared by solvothermal method using monoethanolamine (EA), ethylene glycol (EG), and ethylenediamine (EN) to act as a mixed and pure solvent at multiple Cd and S concentrations. X-ray diffraction (XRD) patterns have shown CdS micro- and nano-structures with hexagonal and wurtzite structures. Scanning electron microscopy (SEM) has depicted nanosheet existence, microsphere, and microrods of CdS at various volume ratios. Transmission electron microscopy (TEM) has shown nanorod existence and nanoparticles of CdS at various volume ratios. Optical properties have been investigated using UV-Vis. A vibrating sample magnetometer (VSM) has been used to measure the CdS nanoparticle ferromagnetism at ambient temperature. The saturation magnetization has exhibited 9.109 (10{sup −3} emu/g). The ferromagnetic properties of CdS are referred to their structural defects.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Application of HRGS for forensic characterization of uranium oxides, pure uranium metals and uranium alloys

A nondestructive iterative method for uranium-bearing material characterization with HRGS developed earlier in (J. appl. Rad. Isotopes, 166 (2020) 109433) is applied to determine matrix densities and uranium isotope masses of a variety of uranium materials, namely uranium ore, UO 2 and U 3 O 8 powders, fuel elements in the form of UO2 microspheres, uranium metal and uranium alloys. It is shown that U 3 O 8 powders with uranium mass fraction of about 84% can be distinguished from the powders of UO 2 with uranium mass fraction of about 87%; uranium products in the form of liquid or loose powder with matrix density of 0.5-2.0 g/cm 3 can be distinguished from uranium products in the form of compacted fuel elements with matrix density of 6.0-10.0 g/cm 3 and from pure metal uranium and uranium alloys with matrix density of 14.0- 19.0 g/cm 3 . In fuel microspheres based on UO2 the uranium mass fraction 88.02% measured by HRGS is consistent, within the measurement uncertainties, with the results of isotope dilution mass spectrometry 87.76±0.64 % and also is confirmed by X-ray diffraction technique. The uranium mass fraction of the uranium ore estimated as 0.08% by HRGS is consistent, within the measurement uncertainties, with the value 0.09±0.01% determined with WDXRF. Densities of two different uranium metal samples, estimated as 18.42 g/cm 3 and 19.33 g/cm 3 by HRGS are consistent with values 18.24±0.55 g/cm 3 and 18.86±0.59 g/cm 3 , respectively, obtained by the gas pycnometry technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and characteristics of ultra high-performance lightweight cementitious composites (UHP-LCCs)

Highlights: • An ultra high-performance lightweight cementitious composite (UHP-LCC) was designed. • The UHP-LCCs had ultra high strength (>120 MPa) and very low density (3 ). • The UHP-LCCs had high structural efficiency, good functional properties and superior durability. • The strategies and mechanisms on achieving UHP-LCCs with excellent performance were proposed. High strength and light weight are two recent opposite development trends of concrete. This study proposed a design concept of an ultra high-performance lightweight cementitious composite (UHP-LCC), which had a compressive strength of higher than 120 MPa and an air-dried density down to around 1800 kg/m{sup 3}. The UHP-LCCs were innovatively developed by incorporating micro-sized hollow particles with a high strength shell (hollow glass microspheres, HGM) into an ultra-high performance cementitious composite (UHPC). The roles of HGM in the UHP-LCCs were investigated by evaluating the reactivity of the HGM and the mechanisms on achieving the excellent mechanical properties, low density and superior durability were revealed. The Chapelle test results showed that the HGM exhibited some pozzolanic reactivity, which facilitated the reaction between the shell of HGM and the alkali hydration products of the paste matrix. This chemical reaction was conducive to improving the HGM-paste interface and enhancing the mechanical properties. With the use of microspheres with a high stiff shell, the fundamental properties of the UHP-LCCs including thermal insulation, sound absorption, resistance to water ingress and electrical resistivity were improved significantly. The strategies for preparing the UHP-LCCs with high structural efficiency and great performance were proposed. The results of this study provide a new approach for designing and producing a lightweight UHPC, which would be a promising material for long-span structures.

36 MATERIALS SCIENCE↗

The Addition of Silicon Carbide to Surrogate Nuclear Fuel Kernels Made by the Internal Gelation Process

The US Department of Energy plans to use the internal gelation process to make tristructural isotropic (TRISO)-coated transuranic (TRU) fuel particles. The focus of this work is to develop TRU fuel kernels with high crush strengths, good ellipticity, and adequately dispersed silicon carbide (SiC). The submicron SiC particles in the TRU kernels are to serve as getters for excess oxygen and to potentially sequester palladium, rhodium, and ruthenium, which could damage the coatings during irradiation. Zirconium oxide microspheres stabilized with yttrium were used as surrogates because zirconium and TRU microspheres from the internal gelation process are amorphous and encounter similar processing problems. The hardness of SiC required modifications to the experimental system that was used to make uranium carbide kernels. Suitable processing conditions and equipment changes were identified so that the SiC could be homogeneously dispersed in gel spheres for subsequent calcination into strong spherical kernels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗