Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAMMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Nasal Chondromesenchymal Hamartoma in a Child

Nasal chondromesenchymal hamartoma (NCMH) is a benign tumor that was described in 1998. The occurrence of this lesion in the nasal cavity of infants and children is especially rare, with only 21 cases reported in the international literature. We report a 12-month-old boy with respiratory distress due to nasal obstruction. Computed tomographic scan and magnetic resonance imaging examination demonstrated a soft-tissue mass obstructing the left nasal cavity. Digital subtraction angiography and preoperative superselective embolization with microparticles were also performed. The tumor was completely resected surgically. Histopathology and immunohistochemical analyses of the tumor disclosed a NCMH. The imaging characteristics of the tumor are described and the radiology literature is reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Creation of a Tumor-Mimic Model Using a Muscle Paste for Radiofrequency Ablation of the Lung

The purpose of this study was to develop an easily created tumor-mimic model and evaluate its efficacy for radiofrequency ablation (RFA) of the lung. The bilateral lungs of eight living adult swine were used. A tumor-mimic model was made by percutaneous injection of 1.0 ml muscle paste through the bone biopsy needle into the lung. An RFA probe was then inserted into the tumor mimics immediately after tumor creation. Ablation time, tissue impedance, and temperature were recorded. The tumor mimics and their coagulated regions were evaluated microscopically and macroscopically. The muscle paste was easily injected into the lung parenchyma through the bone biopsy needle and well visualized under fluoroscopy. In 10 of 12 sites the tumor mimics were oval shaped, localized, and homogeneous on gross specimens. Ten tumor mimics were successfully ablated, and four locations were ablated in the normal lung parenchyma as controls. In the tumor and normal lung parenchyma, ablation times were 8.9 {+-} 3.5 and 4.4 {+-} 1.6 min, respectively; tissue impedances at the start of ablation were 100.6 {+-} 16.6 and 145.8 {+-} 26.8 {Omega}, respectively; and temperatures at the end of ablation were 66.0 {+-} 7.9 and 57.5 {+-} 7.6{sup o}C, respectively. The mean size of tumor mimics was 13.9 x 8.2 mm, and their coagulated area was 18.8 x 13.1 mm. In the lung parenchyma, the coagulated area was 15.3 x 12.0 mm. In conclusion, our tumor-mimic model using muscle paste can be easily and safely created and can be ablated using the ablation algorithm in the clinical setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization with Radiolabeled Polyvinyl Alcohol Particles in a Swine Model: Hepatic Distribution and Implications for Pancreatic Islet Cell Transplantation

The distribution of radiolabeled polyvinyl alcohol microspheres (PVAMs) when infused into the portal vein of domestic swine was investigated, with the purpose of assessing implications for pancreatic islet cell transplantation. PVAMs measuring 100-300 {mu}m (Contour SE) and labeled with {sup 99m}Tc were infused into the main portal vein of 12 swine, with intermittent portal venous pressure measurements. The infusion catheter was introduced antegradely via direct or indirect cannulation of the portal vein. The liver was subsequently divided into anatomical segments. Radioactivity (decay corrected) was measured for {sup 99m}Tc microsphere synthesis, dose preparation, gross organ activities, tissue samples, and blood. Particulate labeling, catheter positioning, and infusion were successful in all cases. The number of particles used was (185,000 {+-} 24,000) with a volume of 1 ml. Mean portal pressure at 5 min was significantly higher than baseline, but without a significant difference at 15 min. Extrahepatic tissue and serum radioactivity was negligible. A significant difference in number of radioactive particles per gram was detected between segments 6/7 and segments 5/8. Intrasegmental activity was analyzed, and for segments 2/3 a significant difference in the percentage dose per gram across samples was demonstrated (P = 0.001). Effective and stable radiolabeling of PVAMs with {sup 99m}Tc-sulfur colloid was demonstrated. Portal venous infusion of 100- to 300-{mu}m particles showed entrapment in the sinusoidal hepatic system with transient portal pressure elevation. Preferential embolization into the right lateral and posterior segments occurs, suggesting that flow dynamics/catheter tip position plays a role in particle distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Telemetric Catheter-Based Pressure Sensor for Hemodynamic Monitoring: Experimental Experience

The purpose of this study was to evaluate the technical and animal experimental feasibility of a percutaneously implantable pulmonary arterial implant for permanent hemodynamic monitoring. Two systems for measuring pulmonary artery pressure (PAP) as well as pulmonary artery occlusion pressure (PAOP) were developed by modifying a commercially available pulmonary artery catheter (PAC). First, a cable-bound catheter-based system was designed by implementation of a capacitive absolute-pressure sensor in the catheter tip. This system was developed further into a completely implantable telemetric system. The devices were tested in an acute setting in a total of 10 sheep. The implant was placed with its tip in the descending pulmonary artery via the right jugular approach. Results were compared with conventional PAC positioned in the contralateral pulmonary artery using Pearson's correlation coefficients and Bland-Altman plots. Implantation of the monitoring systems was uneventful in 10 animals. Data from two fully functional cable-bound and telemetric pressure monitoring systems were available, with a total of 18,506 measurements. There was an excellent correlation between reference data and the data obtained with the implants (r = 0.9944). Bland-Altman plots indicated a very good agreement between the techniques. We report the development and successful initial test of an implantable catheter-based device for long-term measurement of PAP and PAOP. Both devices may be applicable for hemodynamic monitoring. Further long-term studies for assessing reliability and durability of the device are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chronic Portal Vein Thrombosis After Liver Transplantation in a Child Treated by a Combined Minimally Invasive Approach

Portal vein thrombosis (PVT) after orthotopic liver transplantation is an infrequent complication, and when it is present surgical treatment is considered for traditional management. Percutaneous transhepatic portal vein angioplasty has been described as an option to treat PVT with a lower morbidity than conventional surgical treatments. This article describes a case of chronic PVT in a child after a living donor liver transplantation managed by percutaneous transhepatic and surgical approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermoablation of Malignant Kidney Tumors Using Magnetic Nanoparticles: An In Vivo Feasibility Study in a Rabbit Model

The objective of this study was to assess the technical feasibility of CT-guided magnetic thermoablation for the treatment of malignant kidney tumors in a VX2 tumor rabbit model. VX2 tumors were implanted into the kidneys of five rabbits and allowed to grow for 2 weeks. After preinterventional CT perfusion imaging, CT-guided injection of superparamagnetic iron oxide particles (300 {mu}l) was performed, followed by exposure of the animals to an alternating electromagnetic field for 15 min ({approx}0.32 kA/m). Then animals underwent CT perfusion imaging again. Afterward, animals were sacrificed and kidneys were dissected for macroscopic and histological evaluation. Changes in perfusion before and after exposure to the alternating magnetic field were analyzed. In one animal no tumor growth could be detected so the animal was used for optimization of the ablation procedure including injection technique and peri-interventional cross-sectional imaging (CT, MRI). After image-guided intratumoral injection of ferrofluids, the depiction of nanoparticle distribution by CT correlated well with macroscopic evaluation of the dissected kidneys. MRI was limited due to severe susceptibility artefacts. Postinterventional CT perfusion imaging revealed a perfusion deficiency around the ferrofluid deposits. Histological workup showed different zones of thermal damage adjacent to the ferrofluid deposits. In conclusion, CT-guided magnetic thermoablation of malignant kidney tumors is technically feasible in an animal model and results in a perfusion deficiency indicating tumor necrosis as depicted by CT perfusion imaging and shown in histological evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings

Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization was defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10-30 microspheres (15-30 {mu}m in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct injury, and portal space fibrosis were not observed. In conclusion, resin microspheres (15-30 {mu}m diameter) trigger virtually no inflammatory response in target tissues (liver and kidney). Clusters rather than individual microspheres were associated with a mild to moderate perivascular inflammatory reaction. There was no evidence of either a prolonged inflammatory reaction or fibrosis in the liver parenchyma following recannalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of MRI to Differentiate Between Temporary and Long-Term Coronary Artery Occlusion in a Minimally Invasive Model of Experimental Myocardial Infarction

The surgical technique employed to determine an experimental ischemic damage is a major factor in the subsequent process of myocardial scar development. We set out to establish a minimally invasive porcine model of myocardial infarction using cardiac contrast-enhanced magnetic resonance imaging (ce-MRI) as the basic diagnostic tool. Twenty-seven domestic pigs were randomized to either temporary or permanent occlusion of the left anterior descending artery (LAD). Temporary occlusion was achieved by inflation of a percutaneous balloon in the left anterior descending artery directly beyond the second diagonal branch. Occlusion was maintained for 30 or 45 min, followed by reperfusion. Permanent occlusion was achieved via thrombin injection. Thirteen animals died peri- or postinterventionally due to arrhythmias. Fourteen animals survived the 30-min ischemia (four animals; group 1), the 45-min ischemia (six animals; group 2), or the permanent occlusion (4 animals; group 3). Coronary angiography and ce-MRI were performed 8 weeks after coronary occlusion to document the coronary flow grade and the size of myocardial scar tissue. The LAD was patent in all animals in groups 1 and 2, with normal TIMI flow; in group 3 animals, the LAD was totally occluded. Fibrosis of the left ventricle in group 1 (4.9 {+-} 4.4%; p = 0.008) and group 2 (9.4 {+-} 2.9%; p = 0.05) was significantly lower than in group 3 (14.5 {+-} 3.9%). Wall thickness of the ischemic area was significantly lower in group 3 versus group 1 and group 2 (2.9 {+-} 0.3, 5.9 {+-} 0.7, and 6.1 {+-} 0.7 mm; p = 0.005). The extent of late enhancement of the left ventricle was also significantly higher in group 3 (16.9 {+-} 2.1%) compared to group 1 (5.3 {+-} 5.4%; p = 0.003) and group 2 (9.7 {+-} 3.4%, p = 0.013). In conclusion, the present model of minimally invasive infarction coupled with ce-MRI may represent a useful alternative to the open chest model for studies of myocardial infarction and scar development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Stent Expansion and Neointimal Proliferation of Oversized Nitinol Stents in Peripheral Arteries

For peripheral endovascular intervention, self-expanding (SE) stents are commonly oversized in relation to target arteries to assure optimal wall apposition and prevent migration. However, the consequences of oversizing have not been well studied. The purpose of this study was to examine the effects of SE stent oversizing (OS) with respect to the kinetics of late stent expansion and the long-term histological effects of OS. Pairs of overlapped 8 x 28-mm Nitinol SE stents were implanted into the iliofemoral arteries of 14 Yucatan swine. Due to variations in target artery size, the stent-to-artery ratio ranged from 1.2:1 to 1.9:1. Lumen and stent diameters were assessed by quantitative angiography at the time of implantation. Following angiographic assessment at 6 months, stented arteries were perfusion-fixed, sectioned, and stained for histological analysis. Immediately following implantation, the stents were found to be expanded to a range of 4.7-7.1 mm, largely conforming to the diameter of the recipient target artery. The stents continued to expand over time, however, and all stents had enlarged to nearly their 8-mm nominal diameter by 6 months. The histological effects of OS were profound, with marked increases in injury and luminal area stenosis, including a statistically significant linear correlation between stent-to-artery ratio and area stenosis. In this experimental model of peripheral endovascular intervention, oversized Nitinol SE stents are constrained by their target artery diameter upon implantation but expand to their nominal diameter within 6 months. Severe OS (stent-to-artery ratio >1.4:1) results in a profound long-term histological response including exuberant neointimal proliferation and luminal stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of Percutaneous Bilioenteric Anastomotic Stricture Treatment in Liver-Transplanted Children

The purpose of this study was to evaluate the mid- and long-term results of percutaneous transhepatic cholangiography (PTC) and biliary drainage in children with isolated bilioenteric anastomotic stenosis (BAS) after pediatric liver transplantation. Sixty-four children underwent PTC from March 1993 to May 2008. Nineteen cholangiograms were normal; 10 showed intrahepatic biliary stenosis and BAS, and 35 showed isolated BAS. Cadaveric grafts were used in 19 and living donor grafts in 16 patients. Four patients received a whole liver, and 31 patients received a left lobe or left lateral segment. Roux-en-Y hepaticojejunostomy was performed in all patients. Indication for PTC was based on clinical, laboratory, and histopathologic findings. In patients with isolated BAS, dilation and biliary catheter placement, with changes every 2 months, were performed. Patients were separated into 4 groups according to number of treatment sessions required. The drainage catheter was removed if cholangiogram showed no significant residual stenosis and normal biliary emptying time after a minimum of 6 months. The relationship between risk factors (recipient's weight <10 kg, previous exposure to Cytomegalovirus, donor-recipient sex and weight relations, autoimmune disease as indication for transplantion, previous Kasai's surgery, use of reduced liver grafts, chronic or acute rejection occurrence) and treatment was evaluated. Before PTC, fever was observed in 46%, biliary dilation in 23%, increased bilirubin in 57%, and increased gamma-glutamyltransferase (GGT) in 100% of patients. In the group with BAS, 24 of 35 (69%) patients had histopathologic findings of cholestasis as did 9 of 19 (47%) patients in the group with normal PTC. Of the 35 patients, 23 (65.7%) needed 1 (group I), 7 needed 2 (group II), 4 needed 3 (group III), and 1 needed 4 treatment sessions (group IV). The best results were observed after 1 treatment session, and the mean duration of catheter placement and replacement was 10 months. The primary patency rate was 61.2%, and the recurrence rate was 34.3% (group I). Seven patients (7 of 35; 20%) had their stricture treated with a second treatment session (group II). The average drainage time in group II was 24 months. During a period >20 months, 4 patients (4 of 35; 11.4%) required 1 additional treatment session (group III), and 1 patient (1 of 35; 2.9%) had a catheter placed at the end of the study period (group IV). Drainage time in group I was significantly shorter than those in groups II, III, and IV (p < 0.05). There was no statistically significant relation between therapeutic response and the selected risk factors (p > 0.05). The majority of complications, such as catheter displacement and leakage, were classified as minor; however, 2 patients (5.7%) with hemobilia were noted. Complications increased according to the need for reintervention. In conclusion, balloon dilation and percutaneous drainage placement is safe and effective, and it has long-term patency for children with BAS after liver transplantation. Because of prolonged treatment time, reintervention may be necessary, thereby increasing the complication rate. Balloon dilation and percutaneous drainage placement should be considered as the first treatment option because of its minimally invasive nature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Veins and Inferior Vena Cava Thrombosis in a Child Treated by Transjugular Intrahepatic Portosystemic Shunt

We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge of the stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thrombus Formation After Percutaneous Catheterization and Manual Compression of the Femoral Artery in Heparinized Sheep

The purpose of this study was to evaluate the angiographic and histopathologic changes in the superficial femoral artery (SFA) in heparinized sheep shortly after catheterization with an 8-Fr sheath and manual compression hemostasis either with standard manual compression (SMC) or with the use of a procoagulant chitosan-based HemCon Bandage. The evaluation was done in 38 SFAs of 19 heparinized (100 mg/kg) sheep. After a 5-min catheterization with an 8-Fr sheath, a 5-min compression was applied. Follow-up angiograms to evaluate hemostasis were done immediately after release of compression and then at 2.5-min intervals until no extravasation was present. Compression was reapplied between angiograms. Final angiograms were performed approximately 30 min after hemostasis and after 3 min of passive flexion and extension of sheep hind limbs. Sheep were then euthanized and SFA specimens with surrounding tissues excised for histopathologic evaluation. Both types of compression caused similar changes in the catheterized SFAs. Follow-up angiograms showed mild arterial narrowing in 14 SFAs and intraluminal clots in 9 SFAs. Histology revealed periarterial hematoma in all 38 specimens. Intraluminal thrombi consisting predominantly of platelets and fibrin were present in 32 SFAs. Their size varied from superficial elevations (8 arteries) to medium-sized, 1- to 2-mm, polypoid protrusions (15 arteries) to large polypoid clots, 3-4 mm long (9 arteries). In six SFAs, the arterial access sites were not included in the obtained specimens. In conclusion, hemostasis with manual compression is achieved in the acute phase by formation of a predominantly platelet-fibrin thrombus occluding the arterial wall access site and often extending significantly into the arterial lumen. The healing process of arterial access sites should be explored several days after catheterization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Screw Placement and Osteoplasty Under Computed Tomographic-Fluoroscopic Guidance in a Case of Advanced Metastatic Destruction of the Iliosacral Joint

We present a case of combined surgical screw placement and osteoplasty guided by computed tomography-fluoroscopy (CTF) in a 68-year-old man with unilateral osteolytic destruction and a pathological fracture of the iliosacral joint due to a metastasis from renal cell carcinoma. The patient experienced intractable lower back pain that was refractory to analgesia. After transarterial particle and coil embolization of the tumor-feeding vessels in the angiography unit, the procedure was performed under general anesthesia by an interdisciplinary team of interventional radiologists and trauma surgeons. Under intermittent single-shot CTF, two K wires were inserted into the left iliosacral joint from a lateral transiliac approach at the S1 level followed by two self-tapping surgical screws. Continuous CTF was used for monitoring of the subsequent polymethylmethacrylate injection through two vertebroplasty cannulas for further stabilization of the screw threads within the osteolytic sacral ala. Both the screw placement and cement injection were successful, with no complications occurring during or after the procedure. With additional nonsteroidal anti-inflammatory and opioid medication, the patient reported a marked decrease in his lower back pain and was able to move independently again at the 3-month follow-up assessment. In our patient with intolerable back pain due to tumor destruction and consequent pathological fracture of the iliosacral joint, CTF-guided iliosacral screw placement combined with osteoplasty was successful with respect to joint stabilization and a reduction in the need for analgesic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Cone-Shaped Aortic Valve Prosthesis for Orthotopic Position: An Experimental Study in Swine

The aim of this experimental study was to evaluate a newly designed cone-shaped aortic valve prosthesis (CAVP) for one-step transcatheter placement in an orthotopic position. The study was conducted in 15 swine using either the transcarotid (11 animals) or the transfemoral (4 animals) artery approach. A 12- or 13-Fr sheath was inserted via arterial cutdown. The CAVP was deployed under fluoroscopic control and its struts, by design, induced significant native valve insufficiency. CAVP function was evaluated by aortography and aortic pressure curve tracing. In 11 of 15 swine the CAVP was properly deployed and functioned well throughout the scheduled period of 2-3 h. In three swine the CAVPs were placed lower than intended, however, they were functional even in the left ventricular outflow tract position. One swine expired due to inadvertent low CAVP placement that caused both aortic regurgitation and immobilization of the anterior mitral valve leaflet by the valve struts. We conclude that this design of CAVP is relatively easy to deploy, works well throughout a short time period (2-3 h), and, moreover, seems to be reliable even in a lower-than-orthotopic position (e.g., infra-annulary space). Longer-term studies are needed for its further evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Controlled Release and Antitumor Effect of Pluronic F127 Mixed with Cisplatin in a Rabbit Model

The purpose of this study was to evaluate pluronic F127 for the controlled release of cisplatin in a rabbit model. Pluronic F127 becomes liquid at temperatures <25{sup o}C and converts to a gelatinous state at temperatures between 25 and 60{sup o}C. Six Japanese white rabbits were injected with pluronic + cisplatin (n = 3, renal group A) or saline + cisplatin (n = 3, renal group B) to measure the platinum concentration in kidneys. Another 25 rabbits with VX2 liver tumors were divided into five equal groups. They were injected with saline, saline + cisplatin, iodized oil + cisplatin, pluronic alone, or pluronic + cisplatin and labeled as liver groups A, B, C, D, and E, respectively. The antitumor effect of pluronic was then assessed. In the presence of pluronic, the platinum concentration in the kidneys of rabbits remained relatively high. In animals with liver tumors, the delivery of pluronic + cisplatin produced higher tumor reduction rates (P < 0.05) than in the other groups, without apparent damage to normal liver tissue. We conclude that pluronic is useful for the controlled release of cisplatin in a rabbit model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗