Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETOMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Heliophysics Environmental & Radiation Measurement Experiment Suite (HERMES): A Small External Payload for the Lunar Gateway with Big Challenges

Currently scheduled for liftoff in 2024, Gateway will be an outpost orbiting the moon for astronauts headed to and from the lunar surface and serve as a staging point for deep space exploration. In January of 2020 NASA headquarters contacted Goddard Space Flight Center to request that they develop a Heliophysics instrumentation package for Gateway. This package would later become known as HERMES-Heliophysics Environmental & Radiation Measurement Experiment Suite. HERMES consists of a Miniaturized Electron pRoton Telescope (MERIT), an Electron Electrostatic Analyzer (EEA), Solar Probe Analyzers (SPAN)-A-ions, and Noise Eliminating Magnetometer Instrument in a Small Integrated System (NEMISIS), which consists of one fluxgate and two Magneto-Inductive Magnetometers. From the beginning the HERMES mission faced a number of Challenges. It was constrained to fit in a small, half meter, cube and it was required to weigh no more than 25kg. A new boom design for the magnetometer would be required and for safety reasons it must be able to retract autonomously with power removed. To complicate matters the location of the SORI-Small ORU- (Orbital Replacement Unit) Robotics Interface, the primary interface for the HERMES platform to the Gateway elements, was undetermined. Also, the mechanical, thermal and electrical interfaces are not fully defined. The Canadian Space Agency is still in process of designing the version of the SORI that will be flown on the Power and Propulsion Element (PPE) and Habitation and Logistics Outpost (HALO) elements, each of which are being developed by different contractors. At the time of initiating the HERMES project, neither of the Gateway module providers were under contract. Additionally, we would later learn the ISS heritage SORI modules were not originally designed for launching on the Gateway elements with a payload directly attached but rather were intended to be brought up on a separate carrier outfitted with launch locks and specialized launch structures from which the robotic arm on Gateway would then be used to detach the payload and install it on the SORI adapters while on orbit. Launching the integrated Payload/SORI on the PPE and HALO elements complicates the stiffness requirements and coupled loads analysis. Adding to this are serious constraints on Field-Of-View (FOV) for solar viewing and severe radiation exposure considerations brought on by slowly raising the orbit through the Van Allen Belts. Just to make things a little more challenging the budget for the entire project was intended to be a low-cost tailored Class-D mission approach. Plus, the effects of Corona VIrus Disease 2019 (COVID-19) were not factored in from the beginning. This paper will discuss what’s being done to overcome these challenges and put HERMES on track for a 2024 Launch Readiness Date (LRD).

Irving Joseph Burt↗

VERNE: Revealing the Mysteries and Histories of Venus

Introduction: The three Venus missions that were recently selected for upcoming flight (VERITAS, DAVINCI+, and EnVision) will be incredibly valuable to our understanding of Venus’ history, geology, and atmosphere. However, even once completed, key gaps in our knowledge of Venus, and more generally the formation and active processes on rocky, Earth-like planets, will still persist. Remaining questions include 1) how global intrinsic magnetic fields might be maintained on rocky worlds, and how they could then go extinct, and 2) what role atmospheric sulfur chemistry plays in climates of Earth-like planets, which is an increasingly timely subject as Earth’s own atmospheric sulfur content is climbing due to human activity. These questions require in-situ observations from Venus’ cloud deck, at the altitudes at which the UV absorber exists. The Venus Environment Research and Novel Exploration (VERNE) mission will address these questions with an aerial platform that will drift around the equatorial region of the planet for 9 days. VERNE will collect data to determine the identity of the mysterious UV absorber, while also taking magnetic field measurements over the tesserae, the regions on Venus that are most likely to retain remanent crustal magnetization, in order to understand the potential role of a past intrinsically-generated global magnetic field on Venus. Mission Objectives: The two major science objectives that drive the VERNE mission are: 1) Determine the identity of the Venusian unknown ultraviolet absorber(s). First observed approximately a century ago [1], the composition of Venus’ ultraviolet (UV) absorber is one of the oldest mysteries in Venus atmospheric chemistry [2,3]. While several candidate UV absorbers (mostly sulfur species) have been proposed, no consensus has been reached on its composition and its specific interactions with the atmosphere. Determining the identity of the UV absorber will aid climate models by showing how and where incident solar energy is absorbed by the atmosphere and make progress towards understanding the chemical and energetic processes taking place above Venus’ upper cloud deck [4]. 2) Determine if Venus retains evidence of a past, internally-generated magnetic field. While Venus does not currently have an intrinsically-generated magnetic field, evidence for the existence of a past field on Venus and a timeline of its decay will fill in a more holistic picture of the evolution of Venus’ geological record and atmosphere. As the oldest geologic units on the surface, Venus’ tesserae may still have remanent crustal magnetization signatures within the rocky composition [5]. In any case, the signatures detected will provide insight into Venus’ past geological and core dynamo activity. Mission Summary: VERNE includes a 3-part flight system made up of 1) an entry system with a HEEET (Heatshield for Extreme Entry Environment Technology) aeroshell, 2) an orbiter for data relay, and 3) an in-situ balloon and gondola. After entry into Venus’ atmosphere, the balloon will be deployed within the upper cloud deck, at an altitude of 62 km, over a tesserae region. The in-situ data collection will last for the duration of 2 full circumnavigations of the planet, which will take ~9 days. Instrumentation Suite: The four instruments that comprise VERNE’s instrument payload will enable the identification of the unknown UV absorber and the detection of remanent crustal magnetization if it exists in the tesserae. The proposed instrument suite cycle during mission operations is shown in Fig. 1. The four instruments are described below: 1) Adams (ion neutral mass spectrometer) has a range of 18-257 AMU and will detect and distinguish the mixing ratios of O₂, H₂O, H₂SO₄, S, S₂, S₃, S₄, S₅, S₆, S₇, S₈, SO, SO₂, OSSO, SO₃, Cl₂, FeCl₃ and other trace sulfur and organic species. The spatial (longitudinal) and temporal (day/night) variations will be observed throughout 2 circumnavigations with a sample cadence of 12 minutes. 2) Shelley (nephelometer) will determine the size distribution of the aerosols (0.4 to 36 um) in the atmosphere. With a size resolution of <0.7 um, it can determine which mode of H2SO4 is present and characterize the large (>30 um) organic particles previously detected by the Venera and Galileo missions [6,7]. 3) Herbert (UV imager) will measure UV radiance at 283 nm (the wavelength of SO2 absorption) and 365 nm (the unknown part of the absorber). UV images will be taken concurrently with the INMS and nephelometer to correlate UV absorption with abundances of the UV absorber species. 4) Vonnegut (magnetometer) has a range of >600 nT and a precision and accuracy of 1 nT. If magnetized by a past field, the crust may have retained a magnetization of up to 3 A/m2 [5]. With a noise floor of 10 nT, the magnetometer will be able to detect RCM from an altitude of 62 km, even if the thickness of the magnetized crust is just 1 km (Fig. 2). Mission Concept Design: VERNE will be launched with a mass of 3300 kg in an intermediate-high performance class vehicle with a 4-m fairing. The 475-day mission includes 466 days for the cruise, coasting, and orbit initialization phases before entry, descent, and balloon deployment. During the 9-day science phase, the aerial platform will make 2 circumnavigations of the planet at an altitude of 62 km. The INMS and the nephelometer will acquire data for 2 hours during the daytime and nighttime during each circumnavigation, while the UV imager will be on for the duration of the daytime, and the magnetometer will be operational throughout the entirety of the science phase. Data will be stored and processed with the JPL-designed Sphinx command and data handling system. Data will be sent from the balloon to the orbiter using an S-band relay link, stored on the orbiter, and then forwarded to Earth where it will be received by the DSN. Conclusion: VERNE will fill key gaps in our understanding of the history and ongoing processes related to the geology and atmosphere of Venus and rocky worlds in general. Even with adequate flight system contingencies and expected costs below the $900M New Frontiers cost cap, VERNE is not without its risks and challenges. Further trade spaces to explore include 1) using solely battery power vs. including solar panels to increase the mission duration and 2) investigating the use of lightweight materials and 3D-printed structures to reduce the gondola mass, among others. Acknowledgments: We would like to thank the JPL Planetary Science Summer School, especially our mentors Troy Hudson, Karl Mitchell, and Leslie Lowes, as well as our Team-X study lead Al Nash and the members of Team-X. We’d additionally like to thank our review panel for asking insightful questions and providing valuable feedback. References: [1] Ross, F. E. (1928) Astrophysical J., 68, 57-92. [2] Rossow, W. B. et al. (1980) J. Geophysical Research, 85, 8107-8128. [3] Pinto, J. P. et al. (2021) Nature Communications, 12, 175. [4] Titov, D. V. et al. (2007) Cosmic Research, 21, 401. [5] O’Rourke, J. et al. (2019) Geophysical Research Lett., 46, 5768–5777. [6] Limaye, S. S. et al. (2018) Astrobiology, 18(9), 1181-1198. [7] Grinspoon, D. H. et al. (2013) Planetary and Space Sci., 41(7), 515-542. [8] Parker, R. L. (2003) J. Geophysical Research, 108, 5006. *The cost information contained in this document is of a budgetary and planning nature and is intended for informational purposes only. It does not constitute a commitment on the part of JPL and/or Caltech.

H Alpert↗

Optically pumped, radio-frequency atomic magnetometry with feedback stabilization

An optically pumped, atomic magnetometer incorporates a feedback system for stabilizing the magnetic bias field and suppressing unwanted background fields. The magnetic bias field is applied to a vapor cell containing host atoms of two different species, each of which resonates at a different Larmor frequency when both are subjected to the same magnetic bias field. One species provides the feedback for stabilizing the bias field, thereby creating a stabilizing magnetometer portion that nulls out the unwanted background fields. The other species provides magnetic field detection or signal reception on a radio communication frequency of interest, thereby creating a signal magnetometer portion that permits detection of the signal at the radio communication frequency.

Schwindt, Peter D. D.↗

Structural, Magnetic and Microwave Absorption Properties of Ba{sub 0.5}Sr{sub 0.5}Ni{sub 2−x} (MgZn) {sub x/2}Fe{sub 16}O{sub 27} Hexaferrite Nanoparticles Prepared by the Sol-Gel Combustion Method

In this study, Sr–Ba hexaferrite nanoparticles (Ba{sub 0.5}Sr{sub 0.5}Ni{sub 2−x}(MgZn){sub (x/2)}Fe{sub 16}O{sub 27}, x = –0.6, in the step of 0.2) was synthesized by the sol-gel method. The influence of Mg–Zn substitution on the structure and microwave absorption properties of Ni–W-type hexaferrite were investigated by technical methods such as x-ray diffraction, vector network analyzer, transmission electron micrograph and vibrating sample magnetometer. TEM images illustrated almost spherical particles with an average size of 35–52 nm. The M–H loops for all samples were measured at room temperature by vibrating sample magnetometer. Saturation magnetization (M{sub s}) and coercivity (H{sub c}) were derived from the hysteresis loops. The maximum field used in this measurement was 9 kilo-Oersted (kOe) Finally, the microwave absorption properties of these samples were investigated in Ku band range. The thickness of the composites was 2 mm in microwave absorption measurements. The results showed that the synthesized samples have a great potential in many fields of industry.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Cysteine Substitutions on the Structural and Magnetic Properties of Fe{sub 3}O{sub 4}–Cysteine/RGO and Fe{sub 3}O{sub 4}/RGO–Cysteine Nanocomposites

We synthesized by electrostatic self-assembly route in basic solution Fe{sub 3}O{sub 4}–cysteine/RGO and Fe{sub 3}O{sub 4}/RGO–cysteine nanocomposites. In this method, electrostatic interaction was created via negatively charged surface of the reduced graphene oxide and reduced graphene oxide–cysteine sheets and positively charged surface of the Fe{sub 3}O{sub 4} and Fe{sub 3}O{sub 4}–Cys nanoparticles in aqueous solution. The structural and magnetic properties of the prepared samples were analyzed by x-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, transmission electron microscopy (TEM), and vibrating sample magnetometer (VSM), respectively. The dependences of magnetization as a function of applied field using a vibrating sample magnetometer exhibit S-like curves, indicating a magnetic hysteresis behavior for all samples. It clearly showed that, the nanocomposites showed a reduction of saturation magnetization to the Fe{sub 3}O{sub 4} nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of Ba Substitutions on Microstructure and Magnetic Properties of La–Ca–Co System Permanent Ferrite

La{sub 0.6}Ca{sub 0.4−x}Ba{sub x}O⋅n/2(Fe{sub 1−y}Co{sub y}){sub 2}O{sub 3}(x = 0, 0.05, 0.1, 0.15 and 0.2) permanent ferrite materials were prepared by ceramic technique. The topography and the structure were characterized by scanning electron microscopy (SEM) and x-ray diffraction (XRD), respectively. The magnetic properties were measured using vibrating sample magnetometer (VSM) and digital magnetometer. Single M-phase and flake-like grains were obtained for samples without Ba substitution(x = 0), and the magnetic properties of the pre-sintering La–Ca–Co ferrite were as follows: B{sub r} = 440 mT, H{sub cb} = 296 kA/m, H{sub cj} = 426 kA/m, (BH){sub max} = 36.6 kJ/m{sup 3} and H{sub k}/H{sub cj} = 0.83. When Ca was substituted by Ba, pre-sintered powder presents single M-phase structure and close three-dimensional size of grains, resulting in an improved rectangle ratio of sintered magnet. The rectangle ratio of sintered magnet reaches a maximum of 0.93 when x = 0.1. By optimizing process parameters, M-type La–Ca–Ba–Co sintered magnet was prepared with B{sub r} = 445 mT, H{sub cb} = 337 kA/m, H{sub cj} = 420 kA/m, (BH){sub max} = 38.6 kJ/m{sup 3} and H{sub k}/H{sub cj} = 0.95.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unlocking Solutions: Innovative Approaches to Identifying and Mitigating the Environmental Impacts of Undocumented Orphan Wells in the United States

In the United States, hundreds of thousands of undocumented orphan wells have been abandoned, leaving the burden of managing environmental hazards to governmental agencies or the public. These wells, a result of over a century of fossil fuel extraction without adequate regulation, lack basic information like location and depth, emit greenhouse gases, and leak toxic substances into groundwater. For most of these wells, basic information such as well location and depth is unknown or unverified. Addressing this issue necessitates innovative and interdisciplinary approaches for locating, characterizing, and mitigating their environmental impacts. Our survey of the United States revealed the need for tools to identify well locations and assess conditions, prompting the development of technologies including machine learning to automatically extract information from old records (95%+ accuracy), remote sensing technologies like aero-magnetometers to find buried wells, and cost-effective methods for estimating methane emissions. Notably, fixed-wing drones equipped with magnetometers have emerged as cost-effective and efficient for discovering unknown wells, offering advantages over helicopters and quadcopters. Efforts also involved leveraging local knowledge through outreach to state and tribal governments as well as citizen science initiatives. These initiatives aim to significantly contribute to environmental sustainability by reducing greenhouse gases and improving air and water quality.

54 ENVIRONMENTAL SCIENCES↗

Magnetic switching behaviors of orbital states with different magnetic quantum numbers in Au/Fe/MgO multilayer system

A spin specific magnetic hysteresis (SSMH) curve and an orbital specific magnetic hysteresis (OSMH) curve are obtained for Fe/Au/Fe/MgO multilayers by magnetic Compton scattering and SQUID magnetometer measurements. The SSMH curve with each contribution of magnetic quantum number |m| = 0, 1, and 2 states is obtained by decomposition analyses of magnetic Compton profiles. Residual magnetization is observed for the SSMH curve with magnetic quantum number |m| = 0, 2 and the OSMH curve. Although the SQUID magnetometer measurements do not show perpendicular magnetic anisotropy (PMA) in the present Fe/Au/Fe/MgO multilayer film, the SSMH curve with magnetic quantum number |m| = 0, 2 and OSMH curve show switching behaviors of PMA.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma-satellite interaction driven magnetic field perturbations

We report the first fully kinetic quantitative estimate of magnetic field perturbations caused by the interaction of a spacecraft with space environment. Such perturbations could affect measurements of geophysical magnetic fields made with very sensitive magnetometers on-board satellites. Our approach is illustrated with a calculation of perturbed magnetic fields near the recently launched Swarm satellites. In this case, magnetic field perturbations do not exceed 20 pT, and they are below the sensitivity threshold of the on-board magnetometers. Anticipating future missions in which satellites and instruments would be subject to more intense solar UV radiation, however, it appears that magnetic field perturbations associated with satellite interaction with space environment, might approach or exceed instruments' sensitivity thresholds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Zn interstitial defects induced magnetic nature in Fe ions doped ZnO based DMS

This paper describes the synthesis of Fe doped ZnO samples Zn{sub 1-x}Fe{sub x}0, where x various from 0.01≤x≤0.05 (in steps of 0.01) by solution method. The effect of Fe ions doping on the structural, optical and magnetic properties was investigated using X-ray diffraction (XRD), Photoluminescence and vibrating sample magnetometer (VSM) measurements. The observed result indicates that the samples are single phase formation of the wurtzite structure without any significant secondary phase in it. The photoluminescence spectra reveals the presence of Zn vacancies. The magnetic property of prepared samples was studied using a vibrating sample magnetometer and the observed results revealed a super-paramagnetic behavior for the Fe doped ZnO samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FIP effect for minor heavy solar wind ions as seen with SOHO/CELIAS/MTOF

A recent paper [Shearer et al., 2014] reported that during solar maximum Ne showed a surprisingly low abundance. This leads to the question whether other elements show the same behavior. The good mass resolution of Mass-Time-Of-Flight (MTOF) as part of the Charge ELement and Isotope Analysis System (CELIAS) on the Solar Helioshperic Observatory (SOHO) allows to investigate the composition of heavy minor elements in different types of solar wind. We restrict this study to slow solar wind, where the characterisation of slow solar wind is taken from Xu and Borovsky, 2014. This classification scheme requires magnet field information. Since SOHO does not carry a magnetometer, we use the Magnetometer (MAG) of the Advanced Composition Explorer (ACE) instead. The Solar Wind Ion Composition Spectrometer (ACE/SWICS) also provides composition data for cross-calibration and charge-state distributions as input for the transmission function of MTOF whenever the two spacecraft can be expected to observe the same type of wind. We illustrate the MTOF’s capability to determine the solar wind abundance compared to the photospheric abundance (called the FIP ratio in the following) for rare elements like Ti or Cr on long-time scales as a proof of concept for our analysis. And in this brief study, measurements with both ACE/SWICS indicate that the observed elements exhibit a (weak) dependence on the solar cycle, whereas the MTOF measurements are inconclusive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of oxygen plasma etching on Sb{sub 2}Te{sub 3} explored by torque detected quantum oscillations

De Haas–van Alphen measurements evidence that oxygen plasma etching strongly affects the properties of the three-dimensional topological insulator Sb{sub 2}Te{sub 3}. The quantum oscillations in magnetization down to low temperature (T ≥ 2 K) and high magnetic field (B ≤ 7 T) have been systematically investigated using a high-sensitive cantilever torque magnetometer. The effective mass and the oscillation frequency obtained from de Haas–van Alphen measurements first increase and then decrease as the oxygen plasma etching time increases from 0 to 12 min, corresponding to an up- and down-shift of the Dirac point. We establish the cantilever torque magnetometer as a powerful contactless tool to investigate the oxygen sensitivity of the surface state in topological insulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Findings from Restored Apollo Magnetic Field Records

On November 19, 1969, Apollo 12 astronauts installed a Lunar Surface Magnetometer (LSM) as a part ofthe Apollo Lunar Surface Experiment Package, making the first magnetic field measurement on aplanetary body other than Earth. The subsequent Apollo missions deployed two more LSM's (Apollos 15and 16), two Lunar Portable Magnetometers (Apollos 14 and 15), and two Sub-satellite BiaxialMagnetometers (SBMs of Apollos 15 and 16). After almost a half century, the Apollo 15 and 16 missionsare still the only lunar missions conducting simultaneous surface and orbital magnetic field experiments.The Apollo magnetic field experiments enabled many first discoveries, including the lunar magneticanomalies and the electrical conductivity of the Moon. Since the Apollo era, the archaic data format hasbeen hampering the re-examination of Apollo magnetic field records until recently. We have nowrestored most of the digital Apollo magnetic field records archived at NSSDC, including the 0.3-s datafrom the Apollo 12, 15 and 16 LSMs and the 24-s data from Apollo 15 and 16 SBMs. The restored LSMdata have revealed many narrowband ion cyclotron waves in the Earth's magnetotail that were not

Magnetic↗

Relativistic electron response to the combined magnetospheric impact of a coronal mass ejection overlapping with a high-speed stream: Van Allen Probes observations

During early November 2013, the magnetosphere experienced concurrent driving by a coronal mass ejection (CME) during an ongoing high-speed stream (HSS) event. The relativistic electron response to these two kinds of drivers, i.e., HSS and CME, is typically different, with the former often leading to a slower buildup of electrons at larger radial distances, while the latter energizing electrons rapidly with flux enhancements occurring closer to the Earth. In this paper, we present a detailed analysis of the relativistic electron response including radial profiles of phase space density as observed by both Magnetic Electron and Ion Sensor (MagEIS) and Relativistic Electron Proton Telescope instruments on the Van Allen Probes mission. Data from the MagEIS instrument establish the behavior of lower energy (<1 MeV) electrons which span both intermediary and seed populations during electron energization. Measurements characterizing the plasma waves and magnetospheric electric and magnetic fields during this period are obtained by the Electric and Magnetic Field Instrument Suite and Integrated Science instrument on board Van Allen Probes, Search Coil Magnetometer and Flux Gate Magnetometer instruments on board Time History of Events and Macroscale Interactions during Substorms, and the low-altitude Polar-orbiting Operational Environmental Satellites. These observations suggest that during this time period, both radial transport and local in situ processes are involved in the energization of electrons. Finally, the energization attributable to radial diffusion is most clearly evident for the lower energy (<1 MeV) electrons, while the effects of in situ energization by interaction of chorus waves are prominent in the higher-energy electrons.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental limit on an exotic parity-odd spin- and velocity-dependent interaction using an optically polarized vapor

Abstract Exotic spin-dependent interactions between fermions have recently attracted attention in relation to theories beyond the Standard Model. The exotic interactions can be mediated by hypothetical fundamental bosons which may explain several unsolved mysteries in physics. Here we expand this area of research by probing an exotic parity-odd spin- and velocity-dependent interaction between the axial-vector electron coupling and the vector nucleon coupling for polarized electrons. This experiment utilizes a high-sensitivity atomic magnetometer, based on an optically polarized vapor that is a source of polarized electrons, and a solid-state mass containing unpolarized nucleons. The atomic magnetometer can detect an effective magnetic field induced by the exotic interaction between unpolarized nucleons and polarized electrons. We set an experimental limit on the electron-nucleon coupling $$g_{\mathrm{A}}^{\mathrm{e}}g_{\mathrm{V}}^{\mathrm{N}} \, < \, 10^{ - 30}$$ g A e g V N < 1 0 - 30 at the mediator boson mass below 10 −4 eV, significantly improving the current limit by up to 17 orders of magnitude.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Imaging viscous flow of the Dirac fluid in graphene

The electron–hole plasma in charge-neutral graphene is predicted to realize a quantum critical system in which electrical transport features a universal hydrodynamic description, even at room temperature. This quantum critical ‘Dirac fluid’ is expected to have a shear viscosity close to a minimum bound, with an interparticle scattering rate saturating1 at the Planckian time, the shortest possible timescale for particles to relax. Although electrical transport measurements at finite carrier density are consistent with hydrodynamic electron flow in graphene a clear demonstration of viscous flow at the charge-neutrality point remains elusive. In this work, we directly image viscous Dirac fluid flow in graphene at room temperature by measuring the associated stray magnetic field. Nanoscale magnetic imaging is performed using quantum spin magnetometers realized with nitrogen vacancy centres in diamond. Scanning single-spin and wide-field magnetometry reveal a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point, establishing the viscous transport of the Dirac fluid. This measurement is in contrast to the conventional uniform flow profile imaged in a metallic conductor and also in a low-mobility graphene channel. Furthermore, via combined imaging and transport measurements, we obtain viscosity and scattering rates, and observe that these quantities are comparable to the universal values expected at quantum criticality. This finding establishes a nearly ideal electron fluid in charge-neutral, high-mobility graphene at room temperature4. Our results will enable the study of hydrodynamic transport in quantum critical fluids relevant to strongly correlated electrons in high-temperature superconductors9. This work also highlights the capability of quantum spin magnetometers to probe correlated electronic phenomena at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Absolute Magnetometry with He3

We report development of a highly accurate (parts per billion) absolute magnetometer based on 3He NMR. Optical pumping polarizes the spins, long coherence times provide high sensitivity, and the 3He electron shell effectively isolates the nuclear spin providing accuracy limited only by corrections including materials, sample shape, and magnetization. Our magnetometer was used to confirm calibration, to 32 ppb, of the magnetic-field sensors used in recent measurements of the muon magnetic moment anomaly g-2, which differs from the standard model by 2.4 ppm. With independent determination of the magnetic moment of 3He, this work will lead the way to a new absolute magnetometry standard.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗