Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Localization of Recurrent Prostate Cancer After External Beam Radiotherapy

Purpose: To compare the performance of T2-weighted (T2w) imaging and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the prostate gland in the localization of recurrent prostate cancer in patients with biochemical failure after external beam radiotherapy (EBRT). Methods and Materials: T2-weighted imaging and DCE MRI were performed in 33 patients with suspected relapse after EBRT. Dynamic contrast-enhanced MRI was performed with a temporal resolution of 95 s. Voxels enhancing at 46 s after injection to a greater degree than the mean signal intensity of the prostate at 618 s were considered malignant. Results from MRI were correlated with biopsies from six regions in the peripheral zone (PZ) (base, mid, and apex). The percentage of biopsy core positive for malignancy from each region was correlated with the maximum diameter of the tumor on DCE MRI with a linear regression model. Results: On a sextant basis, DCE MRI had significantly better sensitivity (72% [21of 29] vs. 38% [11 of 29]), positive predictive value (46% [21 of 46] vs. 24% [11 of 45]) and negative predictive value (95% [144 of 152] vs. 88% [135 of 153] than T2w imaging. Specificities were high for both DCE MRI and T2w imaging (85% [144 of 169] vs. 80% [135 of 169]). There was a linear relationship between tumor diameters on DCE MRI and the percentage of cancer tissue in the corresponding biopsy core (r = 0.9, p < 0.001), with a slope of 1.2. Conclusions: Dynamic contrast-enhanced MRI performs better than T2w imaging in the detection and localization of prostate cancer in the peripheral zone after EBRT. This may be helpful in the planning of salvage therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Evaluation of Microcirculation by Dynamic Contrast-Enhanced Magnetic Resonance Imaging Predicts Survival in Primary Rectal Cancer Patients

Purpose: To investigate the prognostic value of the perfusion index (PI), a microcirculatory parameter estimated from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), which integrates information on both flow and permeability, to predict overall survival and disease-free survival in patients with primary rectal cancer. Methods and Materials: A total of 83 patients with stage cT3 rectal cancer requiring neoadjuvant chemoradiation were investigated with DCE-MRI before start of therapy. Contrast-enhanced dynamic T{sub 1} mapping was obtained, and a simple data analysis strategy based on the calculation of the maximum slope of the tissue concentration–time curve divided by the maximum of the arterial input function was used as a measure of tumor microcirculation (PI), which integrates information on both flow and permeability. Results: In 39 patients (47.0%), T downstaging (ypT0-2) was observed. During a mean (±SD) follow-up period of 71 ± 29 months, 58 patients (69.9%) survived, and disease-free survival was achieved in 45 patients (54.2%). The mean PI (PImean) averaged over the group of nonresponders was significantly higher than for responders. Additionally, higher PImean in age- and gender-adjusted analyses was strongly predictive of therapy nonresponse. Most importantly, PImean strongly and significantly predicted disease-free survival (unadjusted hazard ratio [HR], 1.85 [ 95% confidence interval, 1.35-2.54; P<.001)]; HR adjusted for age and sex, 1.81 [1.30-2.51]; P<.001) as well as overall survival (unadjusted HR 1.42 [1.02-1.99], P=.040; HR adjusted for age and sex, 1.43 [1.03-1.98]; P=.034). Conclusions: This analysis identifies PImean as a novel biomarker that is predictive for therapy response, disease-free survival, and overall survival in patients with primary locally advanced rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences

Purpose: To validate automatic substitute computed tomography CT (sCT) scans generated from standard T2-weighted (T2w) magnetic resonance (MR) pelvic scans for MR-Sim prostate treatment planning. Patients and Methods: A Siemens Skyra 3T MR imaging (MRI) scanner with laser bridge, flat couch, and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole-pelvis MRI scan (1.6 mm 3-dimensional isotropic T2w SPACE [Sampling Perfection with Application optimized Contrasts using different flip angle Evolution] sequence) was acquired. Three additional small field of view scans were acquired: T2w, T2*w, and T1w flip angle 80° for gold fiducials. Patients received a routine planning CT scan. Manual contouring of the prostate, rectum, bladder, and bones was performed independently on the CT and MR scans. Three experienced observers contoured each organ on MRI, allowing interobserver quantification. To generate a training database, each patient CT scan was coregistered to their whole-pelvis T2w using symmetric rigid registration and structure-guided deformable registration. A new multi-atlas local weighted voting method was used to generate automatic contours and sCT results. Results: The mean error in Hounsfield units between the sCT and corresponding patient CT (within the body contour) was 0.6 ± 14.7 (mean ± 1 SD), with a mean absolute error of 40.5 ± 8.2 Hounsfield units. Automatic contouring results were very close to the expert interobserver level (Dice similarity coefficient): prostate 0.80 ± 0.08, bladder 0.86 ± 0.12, rectum 0.84 ± 0.06, bones 0.91 ± 0.03, and body 1.00 ± 0.003. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same dose prescription was found to be 0.3% ± 0.8%. The 3-dimensional γ pass rate was 1.00 ± 0.00 (2 mm/2%). Conclusions: The MR-Sim setup and automatic sCT generation methods using standard MR sequences generates realistic contours and electron densities for prostate cancer radiation therapy dose planning and digitally reconstructed radiograph generation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlocal Means Denoising of Self-Gated and k-Space Sorted 4-Dimensional Magnetic Resonance Imaging Using Block-Matching and 3-Dimensional Filtering: Implications for Pancreatic Tumor Registration and Segmentation

Purpose: To denoise self-gated k-space sorted 4-dimensional magnetic resonance imaging (SG-KS-4D-MRI) by applying a nonlocal means denoising filter, block-matching and 3-dimensional filtering (BM3D), to test its impact on the accuracy of 4D image deformable registration and automated tumor segmentation for pancreatic cancer patients. Methods and Materials: Nine patients with pancreatic cancer and abdominal SG-KS-4D-MRI were included in the study. Block-matching and 3D filtering was adapted to search in the axial slices/frames adjacent to the reference image patch in the spatial and temporal domains. The patches with high similarity to the reference patch were used to collectively denoise the 4D-MRI image. The pancreas tumor was manually contoured on the first end-of-exhalation phase for both the raw and the denoised 4D-MRI. B-spline deformable registration was applied to the subsequent phases for contour propagation. The consistency of tumor volume defined by the standard deviation of gross tumor volumes from 10 breathing phases (σ-GTV), tumor motion trajectories in 3 cardinal motion planes, 4D-MRI imaging noise, and image contrast-to-noise ratio were compared between the raw and denoised groups. Results: Block-matching and 3D filtering visually and quantitatively reduced image noise by 52% and improved image contrast-to-noise ratio by 56%, without compromising soft tissue edge definitions. Automatic tumor segmentation is statistically more consistent on the denoised 4D-MRI (σ-GTV = 0.6 cm{sup 3}) than on the raw 4D-MRI (σ-GTV = 0.8 cm{sup 3}). Tumor end-of-exhalation location is also more reproducible on the denoised 4D-MRI than on the raw 4D-MRI in all 3 cardinal motion planes. Conclusions: Block-matching and 3D filtering can significantly reduce random image noise while maintaining structural features in the SG-KS-4D-MRI datasets. In this study of pancreatic tumor segmentation, automatic segmentation of GTV in the registered image sets is shown to be more consistent on the denoised 4D-MRI than on the raw 4D-MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Performance of Radiographic Criteria for Bone Malignancy When Applied to Computed Tomography and Magnetic Resonance Imaging

The conventional radiologic features that differentiate benign from malignant bone lesions were originally described using radiography (x-ray [XR]). When evaluating sectional imaging studies such as magnetic resonance imaging (MRI) and computed tomography (CT), one may apply these principles to identify malignant bone lesions. The aim of this study was to evaluate the performances of these radiographic features for detecting malignity when applied to CT and MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure and Dynamics of Brachypodium Primary Cell Wall Polysaccharides from Two-Dimensional 13 C Solid-State Nuclear Magnetic Resonance Spectroscopy

The polysaccharide structure and dynamics in the primary cell wall of the model grass Brachypodium distachyon are investigated for the first time using solid-state nuclear magnetic resonance (NMR). While both grass and non-grass cell walls contain cellulose as the main structural scaffold, the former contains xylan with arabinose and glucuronic acid substitutions as the main hemicellulose, with a small amount of xyloglucan (XyG) and pectins, while the latter contains XyG as the main hemicellulose and significant amounts of pectins. We labeled the Brachypodium cell wall with 13 C to allow two-dimensional (2D) 13 C correlation NMR experiments under magic-angle spinning. Well-resolved 2D spectra are obtained in which the 13 C signals of cellulose, glucuronoarabinoxylan (GAX), and other matrix polysaccharides can be assigned. The assigned 13 C chemical shifts indicate that there are a large number of arabinose and xylose linkages in the wall, and GAX is significantly branched at the developmental stage of 2 weeks. 2D 13 C– 13 C correlation spectra measured with long spin diffusion mixing times indicate that the branched GAX approaches cellulose microfibrils on the nanometer scale, contrary to the conventional model in which only unbranched GAX can bind cellulose. The GAX chains are highly dynamic, with average order parameters of 0.4. Biexponential 13 C T 1 and 1 H T 1ρ relaxation indicates that there are two dynamically distinct domains in GAX: the more rigid domain may be responsible for cross-linking cellulose microfibrils, while the more mobile domain may fill the interfibrillar space. This dynamic heterogeneity is more pronounced than that of the non-grass hemicellulose, XyG, suggesting that GAX adopts the mixed characteristics of XyG and pectins. Moderate differences in cellulose rigidity are observed between the Brachypodium and Arabidopsis cell walls, suggesting different effects of the matrix polysaccharides on cellulose. These data provide the first molecular-level structural information about the three-dimensional organization of the polysaccharides in the grass primary wall.

36 MATERIALS SCIENCE↗

Three-dimensional equilibria and island energy transport due to resonant magnetic perturbation edge localized mode suppression on DIII-D

In this research, we conducted experiments in the DIII-D tokamak that show that the plasma responds to resonant magnetic perturbations (RMPs) with toroidalmode numbers of n=2 and n=3 without field line reconnection, consistent with resistive magnetohydrodynamic predictions, while a strong nonlinear bifurcation is apparent when edge localized modes(ELMs) are suppressed. The magnetic response associated with this bifurcation is localized to the high field side of the machine and exhibits a dominant n=1 component despite the application of a constant amplitude, slowly toroidally rotating, n=2 applied field. The n=1 mode is born locked to the vacuum vessel wall, while the n=2 mode is entrained to the rotating field. Based on these magnetic response measurements and Thomson scattering measurements of flattening of the electron temperature profile, it is likely that these modes are magnetic island chains near the H-mode pedestal. The reduction in ∇Te occurs near the q=4 and 5 rational surfaces, suggesting five unique islands are possible (m=8, 9, or 10 for n=2) and (m=4 or 5 for n=1). In all cases, the island width is estimated to be 2–3 cm. The Chang-Callen calculated confinement degradation due to the presence of an individual island of this size is 8%–12%, which is close to the 13%–14% measured between the ELMs and suppressed states. In conclusion, this suggests that edge tearing modes may alter the pedestal causing peeling-ballooning stability during RMP induced ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of the Early Effects of 5,6-Dimethylxanthenone-4-Acetic Acid Using Macromolecular Contrast Media-Enhanced Magnetic Resonance Imaging: Ectopic Versus Orthotopic Tumors

Purpose: To investigate the early effects of a vascular disrupting agent (VDA) in ectopic and orthotopic tumors by using macromolecular contrast media (MMCM)-enhanced magnetic resonance imaging (MMCM-MRI). Methods and Materials: The MMCM-MRI of ectopic and orthotopic MCA205 murine fibrosarcomas was performed using the intravascular contrast agent albumin-(gadopentetate dimeglumine){sub 35}. Change in longitudinal relaxation rate ({delta}R1) was measured 24 hours after treatment with 5,6-dimethylxanthenone-4-acetic acid (DMXAA; 30 mg/kg) and used to compute tumor vascular volume and permeability. Correlative histologic and immunohistochemical evaluation was carried out, along with measurement of tumor necrosis factor {alpha} and vascular endothelial growth factor levels in whole tumor extracts using the enzyme-linked immunosorbent assay. Results: Orthotopic tumors showed higher vascular volume (p < 0.05) than ectopic tumors before treatment. Twenty-four hours after DMXAA treatment, a significant (p < 0.0001), but differential, decrease in {delta}R1 (70% in ectopic and 50% in orthotopic tumors) was observed compared with baseline estimates. Consistent with this observation, greater levels of tumor necrosis factor {alpha}, an important mediator of the antivascular activity of DMXAA, were measured in ectopic tumors 3 hours posttreatment compared with orthotopic tumors (p < 0.05). Immunohistochemical (CD31) and histologic (hematoxylin and eosin) sections of ectopic and orthotopic tumors showed highly tumor-selective vascular damage after treatment with the presence of viable surrounding normal tissue. Conclusions: The MMCM-MRI provided early quantitative estimates of change in tumor perfusion after VDA treatment that showed good correlation with cytokine induction. Differences in the response of ectopic and orthotopic tumors highlight the influence of the host microenvironment in modulating the activity of VDAs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Super-Resolution Approach to Time-Resolved Volumetric 4-Dimensional Magnetic Resonance Imaging With High Spatiotemporal Resolution for Multi-Breathing Cycle Motion Assessment

Purpose: To develop and evaluate a super-resolution approach to reconstruct time-resolved 4-dimensional magnetic resonance imaging (TR-4DMRI) with a high spatiotemporal resolution for multi-breathing cycle motion assessment. Methods and Materials: A super-resolution approach was developed to combine fast 3-dimensional (3D) cine MRI with low resolution during free breathing (FB) and high-resolution 3D static MRI during breath hold (BH) using deformable image registration. A T1-weighted, turbo field echo sequence, coronal 3D cine acquisition, partial Fourier approximation, and SENSitivity Encoding parallel acceleration were used. The same MRI pulse sequence, field of view, and acceleration techniques were applied in both FB and BH acquisitions; the intensity-based Demons deformable image registration method was used. Under an institutional review board–approved protocol, 7 volunteers were studied with 3D cine FB scan (voxel size: 5 × 5 × 5 mm{sup 3}) at 2 Hz for 40 seconds and a 3D static BH scan (2 × 2 × 2 mm{sup 3}). To examine the image fidelity of 3D cine and super-resolution TR-4DMRI, a mobile gel phantom with multi-internal targets was scanned at 3 speeds and compared with the 3D static image. Image similarity among 3D cine, 4DMRI, and 3D static was evaluated visually using difference image and quantitatively using voxel intensity correlation and Dice index (phantom only). Multi-breathing-cycle waveforms were extracted and compared in both phantom and volunteer images using the 3D cine as the references. Results: Mild imaging artifacts were found in the 3D cine and TR-4DMRI of the mobile gel phantom with a Dice index of >0.95. Among 7 volunteers, the super-resolution TR-4DMRI yielded high voxel-intensity correlation (0.92 ± 0.05) and low voxel-intensity difference (<0.05). The detected motion differences between TR-4DMRI and 3D cine were −0.2 ± 0.5 mm (phantom) and −0.2 ± 1.9 mm (diaphragms). Conclusion: Super-resolution TR-4DMRI has been reconstructed with adequate temporal (2 Hz) and spatial (2 × 2 × 2 mm{sup 3}) resolutions. Further TR-4DMRI characterization and improvement are necessary before clinical applications. Multi-breathing cycles can be examined, providing patient-specific breathing irregularities and motion statistics for future 4D radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear Magnetic Resonance Studies on Vanadium(IV) Electrolyte Solutions for Vanadium Redox Flow Battery

The vanadium (IV) electrolyte solutions with various vanadium concentrations are studied by variable temperature 1H and 17O Nuclear Magnetic Resonance (NMR) spectroscopy. The structure and kinetics of vanadium (IV) species in the electrolyte solutions are explored with respect to vanadium concentration and temperature. It was found that the vanadium (IV) species exist as hydrated vanadyl ion, i.e. [VO(H2O)5]2+ forming an octahedral coordination with vanadyl oxygen in the axial position and the remaining positions occupied by water molecules. This hydrated vanadyl ion structure is stable in vanadium concentrations up to 3M and in the temperature range of 240 to 340 K. The sulfate anions in the electrolyte solutions are found to be weekly bound to this hydrated vanadyl ion and occupies its second coordination sphere. The possible effects of these sulfate anions in proton and water exchange between vanadyl ion and solvent molecules are discussed based on 1H and 17O NMR results.

Environmental Molecular Sciences Laboratory↗

Nuclear magnetic resonance measurement of hydrodynamic dispersion in porous media: preasymptotic dynamics, structure and nonequilibrium statistical mechanics

Measurement of displacement time and length scale dependent dynamics by pulsed gradient spin echo nuclear magnetic resonance in porous media directly provides the preasymptotic hydrodynamic dispersion coefficient. This allows for comparison with nonequilibrium statistical mechanics models of hydrodynamics dispersion in porous media. Preasymptotic dispersion data and models provide characterization of porous media structure length scales relevant to transport and are related to the permeability and sample heterogeneity.

42 ENGINEERING↗

Dynamic T{sub 2}-mapping during magnetic resonance guided high intensity focused ultrasound ablation of bone marrow

Focal bone tumor treatments include amputation, limb-sparing surgical excision with bone reconstruction, and high-dose external-beam radiation therapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) is an effective non-invasive thermotherapy for palliative management of bone metastases pain. MR thermometry (MRT) measures the proton resonance frequency shift (PRFS) of water molecules and produces accurate (<1 Degree-Sign C) and dynamic (<5s) thermal maps in soft tissues. PRFS-MRT is ineffective in fatty tissues such as yellow bone marrow and, since accurate temperature measurements are required in the bone to ensure adequate thermal dose, MR-HIFU is not indicated for primary bone tumor treatments. Magnetic relaxation times are sensitive to lipid temperature and we hypothesize that bone marrow temperature can be determined accurately by measuring changes in T{sub 2}, since T{sub 2} increases linearly in fat during heating. T{sub 2}-mapping using dual echo times during a dynamic turbo spin-echo pulse sequence enabled rapid measurement of T{sub 2}. Calibration of T{sub 2}-based thermal maps involved heating the marrow in a bovine femur and simultaneously measuring T{sub 2} and temperature with a thermocouple. A positive T{sub 2} temperature dependence in bone marrow of 20 ms/ Degree-Sign C was observed. Dynamic T{sub 2}-mapping should enable accurate temperature monitoring during MR-HIFU treatment of bone marrow and shows promise for improving the safety and reducing the invasiveness of pediatric bone tumor treatments.

60 APPLIED LIFE SCIENCES↗

Transition in particle transport under resonant magnetic perturbations in a tokamak

Abstract Nonlinear 3D MHD simulations and validations reveal that the hybrid particle-MHD transport is a key process for driving the pump-out in the presence of Resonant Magnetic Perturbations (RMPs) in the KSTAR tokamak. Particle transport and the resulting density pump-out by RMPs are shown to be composed of not only the classical flow convection near magnetic islands due to polarization but also the neoclassical ion diffusion across perturbed magnetic surfaces. The latter is known as the Neoclassical Toroidal Viscosity (NTV) and is integrated into nonlinear MHD simulations here for the first time, revealing that the two-stage pump-outs observed in KSTAR experiments are reproduced only with such integrated nonlinear MHD and transport evolution. Near-resonant responses, which have received less attention than the resonant response, play distinct roles in the pump-out along with the island formation. In addition, this modeling is used to investigate the pump-outs in double-null-like plasmas and numerically capture the effect of the double-null shape on the pump-outs, which may explain the difficulty of Edge Localized Mode (ELM) suppression access in double-like plasmas. This reveals new aspects of the impact toroidal geometry and mode coupling have on 3D physics and reveals the importance of near-resonant components in suppressing ELMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic resonance cholangiopancreatography using optimized integrated combination with parallel imaging and compressed sensing technique

Purpose: To assess the combined parallel imaging (PI) and optimized integrated compressed sensing technique (prototype Compressed SENSE) for magnetic resonance cholangiopancreatography (MRCP) compared with conventional MRCP. Methods: This prospective study was approved by our Institutional Review Board, and all patients provided written informed consent. A total of 56 consecutive patients (27 men and 29 women; mean age 67.2 years) underwent breath-hold three-dimensional (3D) MRCP with PI alone (BH-MRCP; acquisition time, 23 s), respiratory-triggered 3D MRCP with PI alone (RT-MRCP; 201 s) and respiratory-triggered 3D MRCP with Compressed SENSE (RT-MRCPcs; 45 s). Relative duct-to-periductal contrast ratios (RCs) of the pancreaticobiliary ducts were calculated for quantitative image analyses. Two radiologists graded the visibility of the pancreaticobiliary ducts, pancreatic cystic lesion, motion artifact, and overall image quality using a five-point rating scale for qualitative image analyses. Theses qualitative and quantitative measurements were then compared among the three sequences. Results: RCs of the common bile duct, right hepatic duct (RHD), left hepatic duct (LHD), and main pancreatic duct at the pancreatic head, body, and tail segments, were significantly higher RT-MRCP, followed by RT-MRCPcs and BH-MRCP (P < 0.001). The visibility of the peripheral RHD and LHD was slightly better in RT-MRCP than in RT-MRCPcs and BH-MRCP (P < 0.001). The visibility of other pancreaticobiliary ducts, pancreatic cystic lesion, motion artifact, and overall image quality were almost comparable among three sequences. Conclusion: The acquisition time was markedly reduced in RT-MRCPcs compared with conventional RT-MRCP while there were significant differences in both quantitative and qualitative analyses, the differences were small enough that the reduced acquisition time makes up for it.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vessel Size Index Magnetic Resonance Imaging to Monitor the Effect of Antivascular Treatment in a Rodent Tumor Model

Purpose: Vascular disrupting agents are anticancer agents that typically produce a cytostatic tumor response. Vessel size index magnetic resonance imaging (MRI) allows for the estimation of the fractional blood volume (fBV) and blood vessel size (Rv). We assessed whether the vessel size index parameters provided imaging biomarkers for detecting early tumor response to a vascular disrupting agent. Methods and Materials: GH3 prolactinomas were grown subcutaneously in 12 rats. Vessel size index MRI was performed with Sinerem, an ultrasmall superparamagnetic iron oxide intravascular contrast agent, to determine the tumor fBV and Rv. MRI was performed before and at 24 h after treatment with either the vascular disrupting agent, 5,6-dimethylxanthenone 4-acetic acid (DMXAA) (n = 6) or with the drug vehicle (n = 6). After treatment, the tumors were analyzed histologically and correlates with the MRI findings sought. Results: Histogram analysis showed non-normal distributions of Rv and fBV. The 25th percentiles of the fBV and Rv were significantly reduced (p < 0.01) after treatment with DMXAA, with an increase in the regions of low-measured fBV. For the treated and control tumors, the fraction of tumor with an fBV of {<=}1% correlated with the histologically determined percentage of necrosis (r = 0.77, p < 0.005). The fraction of tumor with an fBV of {<=}1% in treated tumors was significantly increased compared with before treatment (p < 0.05) and with that in the controls (p < 0.05). Conclusion: The vessel size index results were consistent with the known action of DMXAA to cause vascular collapse, with histogram analysis of the fBV providing the most sensitive indicator of response. In particular, the parameter, the fraction of tumor with an fBV of {<=}1% is a potential biomarker that correlates with the histopathologic measure of tumor necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗