Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linear accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Acceleration and torque feedback for robotic control - Experimental results

Gross motion control of robotic manipulators typically requires significant on-line computations to compensate for nonlinear dynamics due to gravity, Coriolis, centripetal, and friction nonlinearities. One controller proposed by Luo and Saridis avoids these computations by feeding back joint acceleration and torque. This study implements the controller on a Puma 600 robotic manipulator. Joint acceleration measurement is obtained by measuring linear accelerations of each joint, and deriving a computationally efficient transformation from the linear measurements to the angular accelerations. Torque feedback is obtained by using the previous torque sent to the joints. The implementation has stability problems on the Puma 600 due to the extremely high gains inherent in the feedback structure. Since these high gains excite frequency modes in the Puma 600, the algorithm is modified to decrease the gain inherent in the feedback structure. The resulting compensator is stable and insensitive to high frequency unmodeled dynamics. Moreover, a second compensator is proposed which uses acceleration and torque feedback, but still allows nonlinear terms to be fed forward. Thus, by feeding the increment in the easily calculated gravity terms forward, improved responses are obtained. Both proposed compensators are implemented, and the real time results are compared to those obtained with the computed torque algorithm.

Mclnroy, John E.↗

Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data

Purpose: Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Methods: Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Results: Distributions of the parameter data were shown to be robust and derive from a student’s t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. Conclusions: IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist’s acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.

60 APPLIED LIFE SCIENCES↗

Analytical and numerical studies of dark current in radiofrequency structures for short-pulse high-gradient acceleration

High-gradient acceleration is a key research area that could enable compact linear accelerators for future colliders, light sources, and other applications. In the pursuit of high-gradient operation, rf breakdown limits the attainable accelerating gradient in normal-conducting rf structures. Recent experiments at the Argonne Wakefield Accelerator suggest a promising approach: using short rf pulses with durations of a few nanoseconds. Experimental studies show that these 𝒪⁡(1⁢ ⁢ns) rf pulses can mitigate breakdown limitations, resulting in higher gradients. For example, an electric field of nearly 400 MV/m was achieved in an 𝑋-band photoemission gun driven by 6-ns-long rf pulses, with rapid rf conditioning and low dark current observed. Despite these promising results, the short-pulse regime remains an underexplored parameter space, and rf breakdown physics under nanosecond-long pulses requires further investigation. In this paper, we present analytical and numerical simulations of dark current dynamics in accelerating cavities operating in the short-pulse regime. We study breakdown-associated processes spanning different time scales, including field emission, multipacting, and plasma formation, using simulations of the 𝑋-band photogun cavities. The results reveal the advantages of using short rf pulses to reduce dark current and mitigate rf breakdown, offering a path toward a new class of compact accelerators with enhanced performance and reduced susceptibility to breakdown.

Linear accelerators↗

The cryomodule test stand at the European Spallation Source

The European Spallation Source (ESS) is an intergovernmental project building a multidisciplinary research laboratory based upon the world's most powerful neutron source to be built in Lund, Sweden. The ESS will use a linear accelerator which will deliver protons with 5 MW of power to the target at 2.5 GeV with a nominal current of 50 mA. The superconducting part of the linac consists of over 150 niobium cavities cooled with superfluid helium at 2 K. A dedicated cryoplant will supply the cryomodules with single phase helium through an external cryogenic transfer line. The elliptical cavity cryomodules will undergo their site acceptance tests at the ESS cryomodule test stand in Lund. This test stand will use a 4.5 K cryoplant and warm sub-atmospheric compression to supply the 2 K helium. We will show the requirements for the test stand, a layout proposal and discuss the factors determining the required cryogenic capacity, test sequence and schedule.

43 PARTICLE ACCELERATORS↗

Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy

Purpose: The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. Methods: The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-filled ion chambers arranged over an area of 11 × 11 cm. The size of the detectors is 2.3 × 2.3 × 0.5 mm (volume of 0.003 cm{sup 3}) and their spacing in the inner area of 5.5 × 5.5 cm is 2.5 mm center-to-center, whereas in the outer area it is 5 mm center-to-center. The detector reproducibility, dose linearity, and sensitivity to positional changes of the collimator were tested. Also, the output factors of field sizes ranging from 0.5 × 0.5 to 10 × 10 cm{sup 2} both for open and wedged fields have been measured and compared against those measured by a pin-point ionization chamber, liquid filled microchamber, SRS diode, and EDR2 film. Results: Its short-term reproducibility was within 0.2% and its medium and long-term reproducibility was within 0.5% (verified with air ionization chamber absolute dose measurements), which is an excellent result taking into account the daily fluctuation of the linear accelerator and the errors in the device setup reproducibility. The dose linearity and dose rate dependence were measured in the range of 0.5–85 Gy and 0.5–10 Gy min{sup −1}, respectively, and were verified with air ionization chamber absolute dose measurements was within 3%. The measurements of the sensitivity showed that the 2D Array could detect millimetric collimator positional changes. The measured output factors showed an agreement of better than 0.3% with the pinpoint chamber and microliquid filled chamber for the field sizes between 3 × 3 and 10 × 10 cm{sup 2}. For field sizes down to 1 × 1 cm{sup 2}, the agreement with SRS diode and microliquid filled chamber is better than 2%. The measurements of open and wedge-modulated field profiles were compared to the film and ionization chamber in water measurements. Conclusions: The Octavius Detector 1000 SRS is an accurate, precise, and reliable detector, very useful for the daily performance of the patient specific quality assurance of radiotherapy treatment plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo simulations of photoneutron activation in a medical LINAC

The first step of the present study was to simulate the γ-radioactivity produced by photoneutrons in the treatment head of a decommissioned medical LINAC. These results, obtained with MCNPX and CINDER'90, are then compared with γ-ray spectrometric measurements of parts of the treatment head. Our ultimate objective is to simulate the associated production by photonuclear reactions of pure β-emitters, which are more difficult to access experimentally than the γ-ray emitters. (authors)

43 PARTICLE ACCELERATORS↗

Theory of photoemission from cathodes with disordered surfaces

Linear-accelerator-based applications like x-ray free electron lasers, ultrafast electron diffraction, electron beam cooling, and energy recovery linacs use photoemission-based cathodes in photoinjectors for electron sources. Most of these photocathodes are typically grown as polycrystalline materials with disordered surfaces. In order to understand the mechanism of photoemission from such cathodes and completely exploit their photoemissive properties, it is important to develop a photoemission formalism that properly describes the subtleties of these cathodes. Here, the Dowell–Schmerge (D–S) model often used to describe the properties of such cathodes gives the correct trends for photoemission properties like the quantum efficiency (QE) and the mean transverse energy (MTE) for metals; however, it is based on several unphysical assumptions. In the present work, we use Spicer’s three-step photoemission formalism to develop a photoemission model that results in the same trends for QE and MTE as the D–S model without the need for any unphysical assumptions and is applicable to defective thin-film semiconductor cathodes along with metal cathodes. As an example, we apply our model to Cs 3 Sb thin films and show that their near-threshold QE and MTE performance is largely explained by the exponentially decaying defect density of states near the valence band maximum.

43 PARTICLE ACCELERATORS↗

Neutron Cross Section Measurements at ORELA for Improved Nuclear Data and Their Application

Many older neutron cross-section evaluations from libraries such as ENDF/B-VI or JENDL-3.2 exhibit deficiencies or do not cover energy ranges that are important for criticality safety applications. These deficiencies may occur in the resolved and unresolved-resonance regions. Consequently, these evaluated data may not be adequate for nuclear criticality calculations where effects such as self-shielding, multiple scattering, or Doppler broadening are important. To support the Nuclear Criticality Predictability Program, neutron cross-section measurements have been initiated at the Oak Ridge Electron Linear Accelerator (ORELA). ORELA is the only high-power white neutron source with excellent time resolution still operating in the United States. It is ideally suited to measure fission, neutron total, and capture cross sections in the energy range from 1 eV to {approx}600 keV, which is important for many nuclear criticality safety applications.

43 PARTICLE ACCELERATORS↗

Six-Axis Superconducting Accelerometer

Sensitivity and short-term stability high. Design combines superconductivity and magnetic levitation to achieve linear-acceleration sensitivity greater than conventional linear accelerometers, and short-term angular stability better than conventional gyroscopes. Improved accelerometer used to increase precision in inertial navigation and surveying, as sensitive multiple-axis seismic sensor, as component of tensor gravity gradiometer, or to sense accelerations of stabilized platforms or spacecraft.

Paik, Ho Jung↗

Considerations on the design of a rare isotope beam facility based on superconducting heavy ion linacs

To establish an accelerator facility based on superconducting linear accelerator (linac) for nuclear and applied sciences in Korea, the rare isotope science project started in December 2011 under the auspices of the Institute for Basic Science (IBS). The layout of the facility has been mostly frozen since 2013 and civil construction began in 2016. On the other hand, an alternative linac design option was recently investigated in collaboration with the linac development group of Argonne National Lab in search of a further optimized configuration. A new linac lattice was developed and evaluated against realistic machine errors using TRACK. The beam optics simulations and error analysis then proved the soundness of this alternative design. In addition, beam optics of the injector was studied for simultaneous acceleration of both stable and rare isotope beams with the use of an electron beam ion source (EBIS). Additionally considered are alternative options of high-power cyclotrons as ISOL driver in order to enhance the capability of rare isotope beam production and fully exploit the superconducting linac facility built at high cost.

07 ISOTOPE AND RADIATION SOURCES↗

Geant4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complexby replacing the current linear accelerator (linac) with awarm front end (WFE) capable of accelerating H- beamsup to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To preciselymeasure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wirescanners along the superconducting linac are planned forimplementation. This investigation is centered on refiningthe Faraday cup design for the PIP-II Laser wire scannersby utilizing GEANT4, a Monte Carlo simulation toolkit.Leveraging this method enables a comprehensive analysisof particle trajectories, energy deposition, secondary particle emission, backscattering, etc., facilitating optimizationthrough adjustments to cup geometries, materials, andplacement to maximize its efficacy in beam diagnostics.

43 PARTICLE ACCELERATORS↗

Maximizing the efficiency of plasma-based lepton accelerators

The next generation of particle accelerators will likely rely on compact accelerating structures to achieve very high gradients; one such candidate is accelerators using plasmas for the accelerating structures. Because of the small length scales of these structures, they can also be prone to the beam break-up instability, which would spoil the quality of the beam and leave it unsuitable for many applications. The goal of this project is to develop a framework for understanding the instabilities in plasma accelerators using language from conventional linear accelerator instabilities, such as wake fields and wake functions. During the course of this Phase I, we benchmarked a pseudo-spectral particle-in-cell code to determine its suitability for computing wake functions, and developed a procedure for extracting wake functions from a sequence of simulations using this code.

43 PARTICLE ACCELERATORS↗

Research on biophysical evaluation of the human vestibular system

The human vestibular function was studied by the combined approach of advanced measurement and mathematical modelling. Fundamental measurements of some physical properties of endolymph and perilymph, combined with nystagmus measurements and fluid mechanical analysis of semicircular canal function furthered the theory of canal mechanical response to angular acceleration, caloric stimulation and relating linear acceleration. The effects of adaptation seen at low frequency angular stimulation were studied and modelled to remove some shortcomings of the torsion pendulum models. Otolith function was also studied experimentally and analytically, leading to a new set of models for subjective orientation. Applications to special problems of space, including the case of rotating spacecraft were investigated and the interaction of visual and vestibular cues and their relation to proprioceptive information was explored relative to postural control.

Young, L. R.↗

Metrics of Balance Control for Use in Screening Tests of Vestibular Function

Decrements in balance control have been documented in astronauts after space flight. Reliable measures of balance control are needed for use in postflight field tests at remote landing sites. Diffusion analysis (DA) is a statistical mechanical tool that shows the average difference of the dependent variable on varying time scales. These techniques have been shown to measure differences in open-loop and closed-loop postural control in astronauts and elderly subjects. The goal of this study was to investigate the reliability of these measures of balance control. Eleven subjects were tested using the Clinical Test of Sensory Interaction on Balance: the subject stood with feet together and arms crossed on a stable or compliant surface, with eyes open or closed and with or without head movements in the pitch or yaw plane. Subjects were instrumented with inertial motion sensors attached to their trunk segment. The DA curves for linear acceleration measures were characterized by linear fits measuring open- (Ds) and closed-loop (Dl) control, and their intersection point (X-int, Y-int). Ds and Y-int showed significant differences between the test conditions. Additionally, Ds was correlated with the root mean square (RMS) of the signal, indicating that RMS was dominated by open-loop events (< 0.5 seconds). The Y-int was found to be correlated with the average linear velocity of trunk movements. Thus DA measures could be applied to derive reliable metrics of balance stability during field tests.

Fiedler, Matthew↗

Study of beam dynamics of a 100 MeV electron linac

A 100 MeV electron linear accelerator is proposed to be built by APPD, BARC, Mumbai, India for neutron generation purposes. This paper presents the results of electron beam tracking for a 100 MeV standing wave electron linac to determine preferential operation parameters from the results of beam dynamics studies. (author)

43 PARTICLE ACCELERATORS↗

SU-E-J-200: Operation of An Electron Accelerator On An Integrated MR-Linac System

Purpose: An integrated MRI guided radiotherapy system poses a challenge of operating a linear accelerator in the presence of a magnetic field as the magnetic force acting on the electrons could Result in radiation source displacement and subsequent reduction of dose output. It was the purpose of this work to test the performance of a linac in the presence of a 1.5T MRI system. Methods: The first experimental MRI guided radiotherapy system at UMC-Utrecht consisting of an Elekta linac rotating around a 1.5T Magnex magnet was examined. A passive magnetic shield was simulated, designed and installed to reduce the influence of the MRI magnet stray field on the electron beamline. The B field inside the shield was measured as a function of gantry angle and measurements of dose rate constancy upon gantry rotation were performed. Results: The magnitude of the magnetic field on the electron beam path without the shield was as high as 70G. It varied by up to 15G with gantry rotation due to the presence of metal beams in the bunker floor which resulted in dose output drop of up to 70% at certain gantry angles. With the prototype shield, field magnitude was reduced to well below 0.5G everywhere along the electron beam path. Field variation with gantry rotation was decreased to below 0.2G and enabled dose output of the linac to be recovered at all gantry angles. The homogeneity of the field inside the MRI magnet has not been compromised. Conclusion: It was demonstrated that the influence of the 1.5T magnet and the bunker design on the linac operation has been minimised. The performance will be further improved on the Elekta Atlantic system which incorporates a newly developed and optimised Philips magnet design and bunker construction. J Harasimowicz, D Roberts, I Shinton and S Sund are employed by Elekta Limited Crawley, H Wang and M Zhong are employed by Elekta Beijing Medical Systems Co. Ltd., J Overweg is employed by Philips Technologie GmbH Forschungslaboratorien.

60 APPLIED LIFE SCIENCES↗