Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Level 2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Assessing the sequestration time scales of some ocean-based carbon dioxide reduction strategies

Abstract Ocean-based carbon dioxide (CO 2 ) removal (CDR) strategies are an important part of the portfolio of approaches needed to achieve negative greenhouse gas emissions. Many ocean-based CDR strategies rely on injecting CO 2 or organic carbon (that will eventually become CO 2 ) into the ocean interior, or enhancing the ocean’s biological pump. These approaches will not result in permanent sequestration, because ocean currents will eventually return the injected CO 2 back to the surface, where it will be brought into equilibrium with the atmosphere. Here, a model of steady state global ocean circulation and mixing is used to assess the time scales over which CO 2 injected in the ocean interior remains sequestered from the atmosphere. There will be a distribution of sequestration times for any single discharge location due to the infinite number of pathways connecting a location at depth with the sea surface. The resulting probability distribution is highly skewed with a long tail of very long transit times, making mean sequestration times much longer than typical time scales. Deeper discharge locations will sequester purposefully injected CO 2 much longer than shallower ones and median sequestration times are typically decades to centuries, and approach 1000 years in the deep North Pacific. Large differences in sequestration times occur both within and between the major ocean basins, with the Pacific and Indian basins generally having longer sequestration times than the Atlantic and Southern Oceans. Assessments made over a 50 year time horizon illustrates that most of the injected carbon will be retained for injection depths greater than 1000 m, with several geographic exceptions such as the Western North Atlantic. Ocean CDR strategies that increase upper ocean ecosystem productivity with the goal of exporting more carbon to depth will have mainly a short-term influence on atmospheric CO 2 levels because ∼70% will be transported back to the surface ocean within 50 years. The results presented here will help plan appropriate ocean CDR strategies that can help limit climate damage caused by fossil fuel CO 2 emissions.

54 ENVIRONMENTAL SCIENCES↗

An Adaptive Critic Approach to Reference Model Adaptation

Neural networks have been successfully used for implementing control architectures for different applications. In this work, we examine a neural network augmented adaptive critic as a Level 2 intelligent controller for a C- 17 aircraft. This intelligent control architecture utilizes an adaptive critic to tune the parameters of a reference model, which is then used to define the angular rate command for a Level 1 intelligent controller. The present architecture is implemented on a high-fidelity non-linear model of a C-17 aircraft. The goal of this research is to improve the performance of the C-17 under degraded conditions such as control failures and battle damage. Pilot ratings using a motion based simulation facility are included in this paper. The benefits of using an adaptive critic are documented using time response comparisons for severe damage situations.

Krishnakumar, K.↗

Two-level Clustering-based Target Detection Through Sensor Deployment and Data Fusion

Target detection is one fundamental problem in many sensor network-based applications, which is typically tackled in two separate stages for sensor deployment and data fusion. We propose an integrated solution, referred to as 2C-SSEM,which combines 2-level clustering-based sensor deployment and source strength estimate map-based data fusion for the detection of a single static or moving target. 2C-SSEM conducts the first level of clustering to determine a sensor deployment scheme and the second level of clustering to divide the deployed sensors into several subsets. For each sensor, the source strength is estimated at each grid point of the entire region based on a signal attenuation model, and for each subset of sensors, the target location is estimated using a distribution map-based statistical analysis method. A final detection decision is made by thresholding the clustering degree of the target location estimates computed by all subsets of sensors. Compared with traditional grid-based target detection methods, 2C-SSEM significantly reduces the computation complexity and improves the detection performance through an integrated optimization strategy. Extensive simulation results show the performance superiority of the proposed solution over several well-known methods for target detection.

Rao, Nageswara↗

Resonant Cascaded Downconversion

We analyze an optical parametric oscillator (OPO) in which cascaded down-conversion occurs inside a cavity resonant for all modes but the initial pump. Due to the resonant cascade design, the OPO presents two {chi}{sup (2)}-level oscillation thresholds that are therefore much lower than for a {chi}{sup (3)} OPO. This is promising for reaching the regime of an effective third-order nonlinearity well above both thresholds. Such a {chi}{sup (2)} cascaded device also has potential applications in frequency conversion to far-infrared regimes. But, most importantly, it can generate novel multipartite quantum correlations in the output radiation, which represent a step beyond squeezed or entangled light. The output can be highly non-Gaussian and therefore not describable by any semiclassical model. In this paper, we derive quantum stochastic equations in the positive-P representation and undertake an analysis of steady-state and dynamical properties of this system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

60 APPLIED LIFE SCIENCES↗

High Altitude Radiations Relevant to the High Speed Civil Transport (HSCT)

The Langley Research Center (LaRC) performed atmospheric radiation studies under the SST development program in which important ionizing radiation components were measured and extended by calculations to develop the existing atmospheric ionizing radiation (AIR) model. In that program the measured neutron spectrum was limited to less than 10 MeV by the available 1960-1970 instrumentation. Extension of the neutron spectrum to high energies was made using the LaRC PROPER-3C monte carlo code. It was found that the atmospheric neutrons contributed about half of the dose equivalent and approximately half of the neutron contribution was from high energy neutrons above 10 MeV. Furthermore, monte carlo calculations of solar particle events showed that potential exposures as large as 10-100 mSv/hr may occur on important high latitude routes but acceptable levels of exposure could be obtained if timely descent to subsonic altitudes could be made. The principal concern was for pregnant occupants onboard the aircraft. As a result of these studies the FAA Advisory Committee on the Radiobiological Aspects of the SST recommended: 1. Crew members will have to be informed of their exposure levels 2. Maximum exposures on any flight to be limited to 5 mSv 3. Airborne radiation detection devices for total exposure and exposure rates 4. Satellite monitoring system to provide SST aircraft real-time information on atmospheric radiation levels for exposure mitigation 5. A solar forecasting system to warn flight operations of an impending solar event for flight scheduling and alert status. These recommendations are a reasonable starting point to requirements for the HSCT with some modification reflecting new standards of protection as a result of changing risk coefficients.

Wilson, J. W.↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=about 15 orbits/day].

NEAR IR IMAGERY↗

MISR Level 1B1 Radiance Data (MI1B1_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 meters - < 500 meters; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly, about 15 orbits/day, Daily - < Weekly].

EOSDIS↗

MISR Level 1B1 Radiance Data (MI1B1_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km; Longitude_Resolution=1.1 km; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=about 15 orbits/day].

AM-1↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Temporal_Resolution=about 15 orbits/day].

AM-1↗

Machine learning based noise reduction for satellite products: application to solar-induced fluorescence retrievals using simulated and real data

In the past two decades, global satellite measurements of terrestrial chlorophyll solar-induced fluorescence (SIF) have been used widely for a number of different applications related to physiology, phenology, and productivity of plants. However, SIF retrievals are inherently noisy due to the relatively small SIF spectral signature in comparison with observational noise. In this work, we examine how a spectral-based approach that employs principal component analysis along with a relatively shallow artificial neural network can be used to reduce noise and other artifacts in satellite level 2 (L2) products. We first apply the approach in a controlled environment in which radiance spectra are simulated with a full atmospheric and surface radiative transfer model for different scenarios including various SIF values that are known. Various levels of noise can be added to the simulated spectra. Resulting noisy and noise-reduced SIF retrievals are compared with the true values to assess performance. We then apply the noise reduction approach to real SIF derived from instruments flying on meteorological satellites. The results are evaluated by comparing SIF retrievals from different platforms with each other and with other independent data sets, showing enhanced capability to capture seasonal and interannual variability in SIF.

Chlorophyll fluorescence↗

Decline in malaria incidence in a typical county of China: Role of climate variance and anti-malaria intervention measures

Highlights: • Malaria incidence shows a steeply interannual decline and an obvious seasonality. • Malaria incidence highly correlates to temperature, precipitation and humidity. • Two favorable climate conditions are determined for high incidence of malaria. • There is good agreement between a decreasing malaria incidence and slightly declined climate variance in epidemic months. • Malaria incidence is declined rapidly because of the persistent progress of anti-malaria interventions. Malaria is an important vector-borne disease which is widespread in tropical and subtropical areas worldwide as well as in south China. Previous research has separately focused on the association between malaria incidence and meteorological variables or between malaria incidence and anti-malaria intervention measures in China, especially in Yunnan Province. Therefore, a typical county, Tengchong County, in Yunnan Province with high malaria incidence was selected as the study area to investigate the integrated influence of climate variance and anti-malaria intervention measures. Malaria incidence and meteorological variables were analyzed with a 2-month lag. The variables include average monthly temperature, minimum temperature, maximum temperature, cumulative precipitation, wind speed, maximum wind speed, relative humidity and minimum relative humidity. First, the principal component analysis was introduced to investigate the relationship between malaria incidence and meteorological variables; classification and regression trees were used to clarify contributions of key meteorological variables to malaria incidence afterwards. Second, based on existing anti-malaria intervention measures and above results, the integrated impact of climate variance and anti-malaria interventions on interannual trends of malaria incidence was analyzed. High malaria incidence occurred under one of the two meteorological conditions: 1) high minimum temperature combined with high minimum relative humidity or both precipitation and minimum relative humidity above middle level; 2) middle minimum temperature combined with both precipitation and minimum relative humidity below middle levels. Moreover, the steep interannual decline of malaria incidence in Tengchong was determined by slight climate variance and persistent anti-malaria intervention measures during malaria epidemics, predominantly by the latter. These findings will provide evidence data for developing malaria surveillance strategies in China.

54 ENVIRONMENTAL SCIENCES↗

RAVEN Quality Assurance Activities

This report discusses the quality assurance activities needed to raise the Quality Level of Risk Analysis in a Virtual Environment (RAVEN) from Quality Level 3 to Quality Level 2. This report also describes the general RAVEN quality assurance activities. For improving the quality, reviews of code changes have been instituted, more parts of testing have been automated, and improved packaging has been created. For upgrading the quality level, requirements have been created and the workflow has been improved.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation evaluation of a speed-guidance law for Harrier approach transitions

An exponential-deceleration speed guidance law is formulated which mimics the technique currently used by Harrier pilots to perform decelerating approaches to a hover. This guidance law was tested along with an existing two-step constant deceleration speed guidance law, using a fixed-base piloted simulator programmed to represent a YAV-8B Harrier. Decelerating approaches to a hover at a predetermined station-keeping point were performed along a straight (-3 deg glideslope) path in headwinds up to 40 knots and turbulence up to 6 ft./sec. Visibility was fixed at one-quarter nautical mile and 100 ft. cloud ceiling. Three Harrier pilots participated in the experiment. Handling qualities with the aircraft equipped with the standard YAV-8B rate damped attitude stability augmentation system were adequate (level 2) using either speed guidance law. However, the exponential deceleration speed guidance law was rated superior to the constant-deceleration speed guidance law by a Cooper-Harper handling qualities rating of about one unit independent of the level of wind and turbulence. Replacing the attitude control system of the YAV-8B with a high fidelity model following attitude flight controller increased the approach accuracy and reduced the pilot workload. With one minor exception, the handling qualities for the approach were rated satisfactory (level 1). It is concluded that the exponential deceleration speed guidance law is the most cost effective.

Merrick, Vernon K.↗

Optimal A-Train Data Utilization: A Use Case of Aura OMI L2G and MERRA-2 Aerosol Products

Ozone Monitoring Instrument (OMI) aboard NASA's Aura mission measures ozone column and profile, aerosols, clouds, surface UV irradiance, and the trace gases including NO2, SO2, HCHO, BrO, and OClO using UltraViolet electromagnetic spectrum (280 - 400 nm) with a daily global coverage and a pixel spatial resolution of 13 km × 24 km at nadir, and it's been one of the key instruments to study the Earth's atmospheric composition and chemistry. The second Modern-Era Retrospective analysis for Research and Applications (MERRA-2) is NASA's atmospheric reanalysis using an upgraded version of Goddard Earth Observing System Model, version 5 (GEOS-5) data assimilation system. Compared to its predecessor MERRA, MERRA-2 is enhanced with more aspects of the Earth system among which is aerosol assimilation. When comparing between satellite pixel measurements and modeled grid data, how to properly handle counterpart pairing is critical considering their spatial and temporal variations. The comparison between satellite and model data by simply using Level 3 (L3) products may result biases due to lack of detailed temporal information. It has been preferred to inter-compare or implement satellite derived physical quantity (i.e., Level 2 (L2) Swath type) directly with/to model measurements with higher temporal and spatial resolution as possible. However, this has posed a challenge in the community to handle. Rather than directly handling the L2 or L3 data, there is a Level 2G (L2G) product conserving L2 pixel scientific data quality but in Grid type with the global coverage. In this presentation, we would like to demonstrate the optimal utilization of OMI L2G daily aerosol products by comparing with MERRA-2 hourly aerosol simulations matched well in both space and time.

MERRA-2 reanalysis↗

CO 2 Capture Going BIG

“Currently, the world is way off track in meeting the Paris Agreement climate goals. It cannot get back on track without CCS”. This statement, issued by the Global CCS Institute in its recent report on The Global Status of CCS (Carbon Capture and Storage), underlines the importance of developing new methods and technologies to reduce the amount of greenhouse gases in the atmosphere. Since the beginning of the industrial revolution, the atmospheric CO 2 concentration has increased from 280 to 410 parts per million (ppm), which is a 46% increase. Most of the added CO 2 can be attributed to fossil fuel emissions from energy production (i.e., burning coal, natural gas, and oil) and other industries (e.g., cement, steel). The CO 2 level will likely continue to rise in the coming decades, as the world population and the energy consumption continue to increase and rely on fossil fuels. While the Earth’s ecosystems have mechanisms for reducing the amounts of CO 2 present in the atmosphere, absorbing roughly half of our annual emissions, the other half, consisting of about 18 gigatonnes of carbon dioxide per year, will have to be addressed through CCS technologies. At the same time, the global average temperature has already risen about 1 °C over the course of the 20th century, and will likely exceed the 1.5 °C increase limit in a few decades. Undeniably, as the Earth is out of energy balance with the current atmospheric composition, there is more warming in the pipeline even if the global emissions were to be cut to zero today. A recent report from the U.S. National Academy of Sciences concluded that limiting the increase in the global temperature to less than 2 °C by the end of this century becomes exceedingly challenging without large-scale deployment of Negative Emissions Technologies (NETs). NETs, such as Direct Air Capture (DAC), remove CO 2 out of the atmosphere, in effect reducing past emissions. They also can address dispersed emissions from transportation and buildings, which currently account to about 50% of global annual emissions.

01 COAL, LIGNITE, AND PEAT↗

eXtremely Fast Tracker trigger upgrade at CDF

The CDF II eXtremely Fast Tracker (XFT) is a trigger processor which reconstructs charged particle tracks in the transverse plane of the central tracking chamber. The XFT tracks are also extrapolated to the electromagnetic calorimeter and muon chambers to generate trigger electron and muon candidates. The XFT is crucial for the entire CDF II physics program: it detects high P{sub t} lepton from W/Z and heavy flavors decay and, in conjunction with the level 2 processor, it identifies secondary vertices from beauty decay. The XFT has thus been crucial for the recent measurement of the B{sub s}{sup 0} oscillation and {Sigma}{sub b}. The increase of the Tevatron instantaneous luminosity demanded an upgrade of the system to cope with the higher occupancy of the chamber. In the upgraded XFT, three-dimensional tracking reduces the level of fake tracks and measures the longitudinal track parameters, which strongly reinforce the trigger selection. This allows to maintain the trigger perfectly efficient at the record luminosities 2-3 x 10{sup 32} cm{sup -2} s{sup -1} and to maintain intact the CDF II high luminosity physics program, which includes the Higgs search. In this paper we review the architecture, the used technology, the performance and the impact of the upgraded XFT on the entire CDF II trigger strategy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of environmental impact monitoring protocol for offshore carbon capture and storage (CCS): A biological perspective

Offshore geologic storage of carbon dioxide (CO{sub 2}), known as offshore carbon capture and sequestration (CCS), has been under active investigation as a safe, effective mitigation option for reducing CO{sub 2} levels from anthropogenic fossil fuel burning and climate change. Along with increasing trends in implementation plans and related logistics on offshore CCS, thorough risk assessment (i.e. environmental impact monitoring) needs to be conducted to evaluate potential risks, such as CO{sub 2} gas leakage at injection sites. Gas leaks from offshore CCS may affect the physiology of marine organisms and disrupt certain ecosystem functions, thereby posing an environmental risk. Here, we synthesize current knowledge on environmental impact monitoring of offshore CCS with an emphasis on biological aspects and provide suggestions for better practice. Based on our critical review of preexisting literatures, this paper: 1) discusses key variables sensitive to or indicative of gas leakage by summarizing physico-chemical and ecological variables measured from previous monitoring cruises on offshore CCS; 2) lists ecosystem and organism responses to a similar environmental condition to CO{sub 2} leakage and associated impacts, such as ocean acidification and hypercapnia, to predict how they serve as responsive indicators of short- and long-term gas exposure, and 3) discusses the designs of the artificial gas release experiments in fields and the best model simulation to produce realistic leakage scenarios in marine ecosystems. Based on our analysis, we suggest that proper incorporation of biological aspects will provide successful and robust long-term monitoring strategies with earlier detection of gas leakage, thus reducing the risks associated with offshore CCS. - Highlights: • This paper synthesizes the current knowledge on environmental impact monitoring of offshore Carbon Capture and Sequestration (CCS). • Impacts of CO{sub 2} leakage (ocean acidification, hypercapnia) on marine organisms and ecosystems are discussed. • Insights and recommendations on EIA monitoring for CCS operations are proposed specifically in marine ecosystem perspective.

54 ENVIRONMENTAL SCIENCES↗