Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lasers, Optics and optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Space optics; Proceedings of the Seminar, Huntsville, Ala., May 22-24, 1979

The seminar focused on infrared systems, the space telescope, new design for space astronomy, future earth resources systems, and planetary systems. Papers were presented on infrared astronomy satellite, infrared telescope on Spacelab 2, design alternatives for the Shuttle Infrared Telescope Facility, Spacelab 2 infrared telescope cryogenic system, geometrical theory of diffraction and telescope stray-light analysis, Space Telescope scientific instruments, faint-object spectrograph for the Space Telescope, light scattering from multilayer optics, bidirectional reflectance distribution function measurements of stray light suppression coatings for the Space Telescope, optical fabrication of a 60-in. mirror, interferogram analysis for space optics, nuclear-pumped lasers for space application, geophysical fluid flow experiment, coherent rays for optical astronomy in space, optical system with fiber-optical elements, and Pioneer-Venus solar flux radiometer.

Wyman, C. L.↗

Carbon dioxide Doppler lidar wind sensor on a Space Station polar platform

A study has been performed of the feasibility of accommodating a carbon dioxide Doppler lidar on a Space Station polar platform. Results show that such an instrument could be accommodated on a single 1.5 x 2.25-m optical bench, mounted centrally on the earth facing side of the satellite. The power, weight, and thermal issues appear resolvable. However, the question of servicing the instrument remains open, until more data are available on the lifetime of an isotopic CO2 laser.

Petheram, John C.↗

Space-stabilized beam pointing for a bifocal satellite experiment

The pointing and tracking control concept for an experimental ground-based laser beam relay satellite is described. The satellite receives a low-power laser beam from a ground-based laser, processes it, and reflects it to an instrumented target. The primary control objective is to achieve extremely accurate and stable pointing at the target, including moving targets. This is achieved using an optical/inertial stabilization technique. The paper describes the satellite optical layout and pointing control mechanization.

Redding, David C.↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗

Analysis of Pulsed Airborne Lidar Measurements of Atmospheric CO2 Column Absorption from 3-13 km Altitudes

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS space mission [1]. It uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1575 nm band, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver measures the energies of the laser echoes from the surface along with the range profile of scattering in the path. The column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off-line signals via the integrated path differential absorption (IPDA) technique. The time of flight of the laser pulses is used to estimate the height of the scattering surface and to reject laser photons scattered in the atmosphere. We developed an airborne lidar to demonstrate an early version of the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar stepped the pulsed laser's wavelength across the selected CO2 line with 20 wavelength steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a NIR photomultiplier and is recorded on every other reading by a photon counting system [2]. During August 2009 we made a series of 2.5 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over locations in the US, including the SGP ARM site in Oklahoma, central Illinois, north-eastern North Carolina, and over the Chesapeake Bay and the eastern shore of Virginia. Although the received signal energies were weaker than expected for ASCENDS, clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, and in-situ measurements were made using its CO2 sensor and radiosondes. We have conducted an analysis of the ranging and IPDA lidar measurements from these four flights. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We used a cross-correlation approach to process the laser echo records. This was used to estimate the range to the scattering surface, to define the edges of the laser pulses and to determine echo pulse energy at each wavelength. We used a minimum mean square approach to fit an instrument response function and to solve for the best-fit CO2 absorption line shape. We then calculated the differential optical depth (DOD) of the fitted CO2 line. We computed its statistics at the various altitude steps, and compare them to the DODs calculated from spectroscopy based on HITRAN 2008 and the column conditions calculated from the airborne in-situ readings. The results show the lidar and in-situ measurements have very similar DOD change with altitude and greater than 10 segments per flight where the scatter in the lidar measurements are less than or equal to 1ppm. We also present the results from subsequent CO2 column absorption measurements, which were made with stronger detected signals during three flights on the NASA DC-8 over the southwestern US in during July 2010.

Abshire, James B.↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

The International Space Station (ISS) employs a suite of portable and permanently located gas monitors to insure crew health and safety. These sensors are tasked with functions ranging from fixed mass spectrometer based major constituents analysis to portable electrochemical sensor based combustion product monitoring. An all optical multigas sensor is being developed that can provide the specificity of a mass spectrometer with the portability of an electrochemical cell. The technology, developed under the Small Business Innovation Research program, allows for an architecture that is rugged, compact and low power. A four gas version called the Multi-Gas Monitor was launched to ISS in November 2013 aboard Soyuz and activated in February 2014. The portable instrument is comprised of a major constituents analyzer (water vapor, carbon dioxide, oxygen) and high dynamic range real-time ammonia sensor. All species are sensed inside the same enhanced path length optical cell with a separate vertical cavity surface emitting laser (VCSEL) targeted at each species. The prototype is controlled digitally with a field-programmable gate array/microcontroller architecture. The optical and electronic approaches are designed for scalability and future versions could add three important acid gases and carbon monoxide combustion product gases to the four species already sensed. Results obtained to date from the technology demonstration on ISS are presented and discussed.

Pilgrim, Jeffrey S.↗

Optical Parametric Technology for Methane Measurements

Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas, with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. Yet, lack of understanding of the processes that control CH4 sources and sinks and its potential release from stored carbon reservoirs contributes significant uncertainty to our knowledge of the interaction between carbon cycle and climate change. At Goddard Space Flight Center (GSFC) we have been developing the technology needed to remotely measure CH4 from orbit. Our concept for a CH4 lidar is a nadir viewing instrument that uses the strong laser echoes from the Earth's surface to measure CH4. The instrument uses a tunable, narrow-frequency light source and photon-sensitive detector to make continuous measurements from orbit, in sunlight and darkness, at all latitudes and can be relatively immune to errors introduced by scattering from clouds and aerosols. Our measurement technique uses Integrated Path Differential Absorption (IPDA), which measures the absorption of laser pulses by a trace gas when tuned to a wavelength coincident with an absorption line. We have already demonstrated ground-based and airborne CH4 detection using Optical Parametric Amplifiers (OPA) at 1651 nm using a laser with approximately 10 microJ/pulse at 5kHz with a narrow linewidth. Next, we will upgrade our OPO system to add several more wavelengths in preparation for our September 2015 airborne campaign, and expect that these upgrades will enable CH4 measurements with 1% precision (10-20 ppb).

oscillator↗

High-Sensitivity Optical Techniques for Atmospheric Spectroscopy, Kinetics and Remote Sensing

A principal objective of the work supported by this Grant has been to use IntraCavity Laser Absorption Spectroscopy (ICLAS) to acquire data on weakly absorbing species of atmospheric interest that are not accessible, or cannot be determined with sufficient precision, using conventional spectroscopic instrumentation. The principal focus has been to adapt the existing instrument to carry out Kinetic studies using IntraCavity Absorption Spectroscopy (KICAS) in order to measure rate parameters for weakly absorbing, environmentally significant species. Additional related work has been carried out in collaboration with Prof. M.J. Molina's program on air pollution in the Mexico City Metropolitan Area on modeling the role of these species in atmospheric chemistry.

Source record↗

Low Power Consumption Laser for Next Generation Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 mu m wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 mu m and quantum cascade (QC) lasers in the 4.0-5.0 mu m range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft

distributed feedback laser (DFB↗

Low Power Consumption Lasers for Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 micron wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micron and quantum cascade (QC) lasers in the 4.0-5.0 micron range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

Distributed Feedback (DFB) Diode Lasers↗

X-ray/EUV optics for astronomy and microscopy; Proceedings of the Meeting, San Diego, CA, Aug. 7-11, 1989

Topics included in these proceedings are on X-ray/EUV zone plates, filters, and windows; X-ray/EUV microscopes, telescopes, and monochromators; the design, characterization, and test of multilayer optics; the fabrication of X-ray/EUV multilayer optics; and the design, characterization, and test of grazing incidence X-ray optics. Other topics are on the fabrication of grazing incidence X-ray optics, X-ray/EUV space observatories and missions, the test and calibration of X-ray/EUV instruments, X-ray polarimetry, and X-ray/EUV spectroscopy and instruments. Papers are presented on 8-keV X-ray zone plates, a cylindrical X-ray multilayer monochromator, multilayer mirrors for 182 A, advanced flow polishing of exotic optical materials, and optical analysis of grazing incidence ring resonators for free-electron lasers. Attention is also given to X-ray mirrors for the European Synchrotron Radiation Facility, the XUV wide-field camera for Rosat, an optical test and alignment method for the XMM mirror module, Bragg crystal polarimeters, and a liftoff process for multilayer phase gratings.

Hoover, Richard B.↗

Aureole lidar: Design, operation, and comparison with in-situ measurements

In 1986, H. Berber and Hooper examined the signals that could be detected by an airborne lidar flying above the marine boundary layer (MBL). One signal (aureole) formed from laser light returned to the receiver after a reflect off the ocean and forward scatter off the aerosol particles appeared to be both detectable and related to the optical depth of the MBL. Now, research has been directed towards developing a practical instrument to measure the aureole and finding an algorithm to use the information. Unlike the lidar backscatter which typically requires a telescope with a narrow field of view (0.5 mrad), the aureole signal occurs over a wide field of view (50 mrad). To accommodate the totally different needs, a standard commercial Cassegrainian telescope was modified to yield a telescope with two focal planes. The secondary mirror was replaced by a lens, whose front surface was half silvered and curved to match the replaced mirror. Light reflecting off the lens focused behind the primary mirror. The back lens surface was curved to allow unreflected light to focus at the natural focus of the primary mirror. This focal plane which is behind the lens has a wide field of view. To calculate an extinction profile, the aureole optical depth estimate is combined with the lidar backscatter profile.

Hooper, William P.↗

A scientific assessment of a new technology orbital telescope

As part of a program designed to test the Alpha chemical laser weapons system in space, the Ballistic Missile Defense Organization (BMDO) developed components of an agile, lightweight, 4-meter telescope, equipped with an advanced active-optics system. BMDO had proposed to make space available in the telescope's focal plane for instrumentation optimized for scientific applications in astrophysics and planetary astronomy for a potential flight mission. Such a flight mission could be undertaken if new or additional sponsorship can be found. Despite this uncertainty, BMDO requested assistance in defining the instrumentation and other design aspects necessary to enhance the scientific value of a pointing and tracking mission. In response to this request, the Space Studies Board established the Task Group on BMDO New Technology Orbital Observatory (TGBNTOO) and charged it to: (1) provide instrumentation, data management, and science-operations advice to BMDO to optimize the scientific value of a 4-meter mission; and (2) support a space studies board assessment of the relative scientific merit of the program. This report deals with the first of these tasks, assisting the Advanced Technology Demonstrator's (ATD's) program scientific potential. Given the potential scientific aspects of the 4-meter telescope, this project is referred to as the New Technology Orbital Telescope (NTOT), or as the ATD/NTOT, to emphasize its dual-use character. The task group's basic conclusion is that the ATD/NTOT mission does have the potential for contributing in a major way to astronomical goals.

Source record↗

Mode matching method for absorption spectroscopy systems

Systems and methods for controlling optical feedback in an optical system. A resonant optical cavity includes at least two cavity mirrors, one of which is a cavity coupling mirror, and has a plurality of optical resonance cavity modes. A radiation source emits a beam of continuous wave radiation and is capable of being scanned whereby a mean optical frequency of the continuous wave radiation beam is adjustable over a range of frequencies, wherein the radiation source is responsive to optical feedback radiation emerging from the cavity, and wherein the mode matching optics couples the beam of continuous wave radiation to the cavity via the cavity coupling mirror. The radiation source and the mode matching optics are aligned so that a mode fill ratio is reduced relative to a maximum mode fill ratio, wherein the laser beam is coupled with a fundamental cavity mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Transmission Telescope Optical Dynamic Alignment

The Integrated Radio Optical Communication System (iROC) is designed to transmit data between Mars and Earth by means of radio waves at 32.67 GHz (Ka Band) and laser beam at 1550 nm, both transmitted via a combined teletenna. The iROC terminal will provide ‘beaconless’ operations to allow full function from the outer planets. In order to point without the aid of an uplink beacon, the proof of concept presented here is addressing the need for an accurate determination and control of the relative position of the laser beam with respect to a reference star. The experiment presented simulates a surrogate transmission telescope system in laboratory setting and presents the model used in the correction of the outgoing beam. The results of the model show a nonlinear dependence between the outgoing and the reference beam, indicating the necessity of a minimum of two metrology instruments placed along the optical system for increased pointing precision.

optical communication↗

Lidar-based remote infrared gas sensor for monitoring anthropogenic pollution: a proof of concept

We propose using wavelength-modulation laser absorption spectroscopy in combination with quadrature detection of scattered light for remote industrial pollution monitoring in the atmosphere with a compact lidar-based gas sensor, which can be mounted on board an unmanned aerial vehicle. The instrument can be used for detecting leaks in product pipe lines; monitoring toxic gases near landfill sites, waste incineration plants, and other hazardous man-made facilities; analysing the gas atmosphere in industrial buildings and structures; and monitoring engineering processes at a sensitivity level of tens of ppm m in gas concentration measurements at characteristic distances of tens of metres. (laser applications and other issues in quantum electronics)

42 ENGINEERING↗

Roadmap on spatiotemporal light fields

Spatiotemporal sculpturing of light pulse with ultimately sophisticated structures represents a major goal of the everlasting pursue of ultra-fast information transmission and processing as well as ultra-intense energy concentration and extraction. It also holds the key to unlock new extraordinary fundamental physical effects. Traditionally, spatiotemporal light pulses are always treated as spatiotemporally separable wave packet as solution of the Maxwell’s equations. In the past decade, however, more generalized forms of spatiotemporally nonseparable solution started to emerge with growing importance for their striking physical effects. This roadmap intends to highlight the recent advances in the creation and control of increasingly complex spatiotemporally sculptured pulses, from spatiotemporally separable to complex nonseparable states, with diverse geometric and topological structures, presenting a bird’s eye viewpoint on the zoology of spatiotemporal light fields and the outlook of future trends and open challenges.

42 ENGINEERING↗