Relating neuromuscular control to functional anatomy of limb muscles in extant archosaurs

Abstract Electromyography (EMG) is used to understand muscle activity patterns in animals. Understanding how much variation exists in muscle activity patterns in homologous muscles across animal clades during similar behaviours is important for evaluating the evolution of muscle functions and neuromuscular control. We compared muscle activity across a range of archosaurian species and appendicular muscles, including how these EMG patterns varied across ontogeny and phylogeny, to reconstruct the evolutionary history of archosaurian muscle activation during locomotion. EMG electrodes were implanted into the muscles of turkeys, pheasants, quail, guineafowl, emus (three age classes), tinamous and juvenile Nile crocodiles across 13 different appendicular muscles. Subjects walked and ran at a range of speeds both overground and on treadmills during EMG recordings. Anatomically similar muscles such as the lateral gastrocnemius exhibited similar EMG patterns at similar relative speeds across all birds. In the crocodiles, the EMG signals closely matched previously published data for alligators. The timing of lateral gastrocnemius activation was relatively later within a stride cycle for crocodiles compared to birds. This difference may relate to the coordinated knee extension and ankle plantarflexion timing across the swing‐stance transition in Crocodylia, unlike in birds where there is knee flexion and ankle dorsiflexion across swing‐stance. No significant effects were found across the species for ontogeny, or between treadmill and overground locomotion. Our findings strengthen the inference that some muscle EMG patterns remained conservative throughout Archosauria: for example, digital flexors retained similar stance phase activity and M. pectoralis remained an ‘anti‐gravity’ muscle. However, some avian hindlimb muscles evolved divergent activations in tandem with functional changes such as bipedalism and more crouched postures, especially M. iliotrochantericus caudalis switching from swing to stance phase activity and M. iliofibularis adding a novel stance phase burst of activity.

Cuff, Andrew R.↗

The Use of the 'Preclosure' Technique for Antegrade Aspiration Thrombectomy with Large Catheters in Acute Limb Ischemia

This study was designed to assess retrospectively short- and mid-term outcomes of the use of a suture-mediated closure device to close the antegrade access in patients undergoing percutaneous aspiration thrombectomy with large catheters for acute leg ischemia. Between November 2005 and February 2010, a suture-mediated active closure system (ProGlide{sup Registered-Sign} 6F, Abbott) was placed before arterial sheath (mean 9 F, range 6-12 F) introduction in 101 patients (74 men, 73 %, mean age 70.1 {+-} 12.6 years standard deviation). Data regarding mortality, complications, and factors contributing to vascular complications at the access site was collected for 6 month after the intervention to detect device-related problems. As a coincidence, 77 patients had follow-up visits for a duplex ultrasound. There were a total of 19 vascular complications (19 %) at the puncture site, all of which were of hemorrhagic nature and none of which consisted of vessel occlusion. Two major outcome complications (2 %) occurred. A retroperitoneal hematoma and a serious inguinal bleeding required additive treatment and did not result in permanent sequelae. Nine cases involved death of which eight were not attributable to the closure and one remained unclear. Successful closure was achieved in 95 patients (94 %); additional manual compression was sufficient in the majority of the remaining patients. Numerous factors contributing to vascular complications were encountered. With acceptable short- and mid-term outcomes, the 'preclose' technique can be a reliable option for the closure of a large antegrade femoral access even for patients at a high risk of vascular complications, such as those undergoing aspiration thrombectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential emission measure analysis of a limb solar flare on 2012 July 19

We perform Differential Emission Measure (DEM) analysis of an M7.7 flare that occurred on 2012 July 19 and was well observed by the Atmospheric Imaging Assembly (AIA) onboard the Solar Dynamic Observatory. Using the observational data with unprecedented high temporal and spatial resolution from six AIA coronal passbands, we calculate the DEM of the flare and derive the time series of maps of DEM-weighted temperature and emission measure (EM). It is found that, during the flare, the highest EM region is located in the flare loop top with a value varying between ∼8.4 × 10{sup 28} cm{sup –5} and ∼2.5 × 10{sup 30} cm{sup –5}. The temperature there rises from ∼8 MK at about 04:40 UT (the initial rise phase) to a maximum value of ∼13 MK at about 05:20 UT (the hard X-ray peak). Moreover, we find a hot region that is above the flare loop top with a temperature even up to ∼16 MK. We also analyze the DEM properties of the reconnection site. The temperature and density there are not as high as that in the loop top and the flux rope, indicating that the main heating may not take place inside the reconnection site. In the end, we examine the dynamic behavior of the flare loops. Along the flare loop, both the temperature and the EM are the highest in the loop top and gradually decrease toward the footpoints. In the northern footpoint, an upward force appears with a biggest value in the impulsive phase, which we conjecture originates from chromospheric evaporation.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron-ion equilibrium and shock precursors in the northeast limb of the Cygnus Loop

We present an observational study using high-resolution echelle spectroscopy of collisionless shocks in the Cygnus Loop supernova remnant. Measured Hα line profiles constrain pre-shock heating processes, shock speeds, and electron-ion equilibration (T{sub e} /T{sub i} ). The shocks produce faint Hα emission line profiles, which are characterized by narrow and broad components. The narrow component is representative of the pre-shock conditions, while the broad component is produced after charge transfer between neutrals entering the shock and protons in the post-shock gas, thus reflecting the properties of the post-shock gas. We observe a diffuse Hα region extending about 2.'5 ahead of the shock with line width ∼29 km s{sup –1}, while the Hα profile of the shock itself consists of broader than expected narrow (36 km s{sup –1}) and broad (250 km s{sup –1}) components. The observed diffuse emission arises in a photoionization precursor heated to about 18,000 K by He I and He II emission from the shock, with additional narrow component broadening originating from a thin cosmic-ray precursor. Broad to narrow component intensity ratios of ∼1.0 imply full electron-ion temperature equilibration T{sub e} ≅ T{sub i} in the post-shock region. Broad component line widths indicate shock velocities of about 400 km s{sup –1}. Combining the shock velocities with proper motions suggests that the distance to the Cygnus Loop is ∼890 pc, significantly greater than the generally accepted upper limit of 637 pc.

79 ASTRONOMY AND ASTROPHYSICS↗

Angle Assessment for Upper Limb Rehabilitation: A Novel Light Detection and Ranging (LiDAR)-Based Approach

The accurate measurement of joint angles during patient rehabilitation is crucial for informed decision making by physiotherapists. Presently, visual inspection stands as one of the prevalent methods for angle assessment. Although it could appear the most straightforward way to assess the angles, it presents a problem related to the high susceptibility to error in the angle estimation. In light of this, this study investigates the possibility of using a new approach to angle calculation: a hybrid approach leveraging both a camera and LiDAR technology, merging image data with point cloud information. This method employs AI-driven techniques to identify the individual and their joints, utilizing the cloud-point data for angle computation. The tests, considering different exercises with different perspectives and distances, showed a slight improvement compared to using YOLO v7 for angle calculation. However, the improvement comes with higher system costs when compared with other image-based approaches due to the necessity of equipment such as LiDAR and a loss of fluidity during the exercise performance. Therefore, the cost–benefit of the proposed approach could be questionable. Nonetheless, the results hint at a promising field for further exploration and the potential viability of using the proposed methodology.

Klein, Luan C. (ORCID:000000016306574X)↗