Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LCLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities

Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.

43 PARTICLE ACCELERATORS↗

Enhancing SRF cavity stability and minimizing detuning with data-driven resonance control based on dynamic mode decomposition

Effective resonance control of superconducting radio frequency (SRF) cavities is critical for large machines like LCLS-II, as failure to achieve proper control can result in increased RF power consumption, higher cryogenic heat loads, and increased costs. To address this challenge, we have developed a machine learning (ML) model based on the dynamic mode decomposition method to represent the forced cavity dynamics. Using this model, we designed a model predictive controller (MPC) and demonstrated through simulation that the MPC can effectively stabilize the amplitude and phase of SRF cavities using only a frequency actuator, even in the presence of multiple mechanical modes. The lightweight and explicit ML model makes the controller suitable for direct implementation on field-programmable gate arrays, unlocking the full potential of SRF linacs like LCLS-II, enabling higher beam power and energy, and also serving as an advanced motion controller for various applications, such as photon beamlines and storage rings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Disentangling formation of multiple-core holes in aminophenol molecules exposed to bright X-FEL radiation

Competing multi-photon ionization processes, some leading to the formation of double core hole states, have been examined in 4-aminophenol. The experiments used the linac coherent light source (LCLS) x-ray free electron laser, in combination with a time-of-flight magnetic bottle electron spectrometer and the correlation analysis method of covariance mapping. Furthermore, the results imply that 4-aminophenol molecules exposed to the focused x-ray pulses of the LCLS sequentially absorb more than two x-ray photons, resulting in the formation of multiple core holes as well as in the sequential removal of photoelectrons and Auger electrons (so-called PAPA sequences).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multipoint-BAX: a new approach for efficiently tuning particle accelerator emittance via virtual objectives

Abstract Although beam emittance is critical for the performance of high-brightness accelerators, optimization is often time limited as emittance calculations, commonly done via quadrupole scans, are typically slow. Such calculations are a type of multipoint query , i.e. each query requires multiple secondary measurements. Traditional black-box optimizers such as Bayesian optimization are slow and inefficient when dealing with such objectives as they must acquire the full series of measurements, but return only the emittance, with each query. We propose a new information-theoretic algorithm, Multipoint-BAX , for black-box optimization on multipoint queries, which queries and models individual beam-size measurements using techniques from Bayesian Algorithm Execution (BAX). Our method avoids the slow multipoint query on the accelerator by acquiring points through a virtual objective , i.e. calculating the emittance objective from a fast learned model rather than directly from the accelerator. We use Multipoint-BAX to minimize emittance at the Linac Coherent Light Source (LCLS) and the Facility for Advanced Accelerator Experimental Tests II (FACET-II). In simulation, our method is 20× faster and more robust to noise compared to existing methods. In live tests, it matched the hand-tuned emittance at FACET-II and achieved a 24% lower emittance than hand-tuning at LCLS. Our method represents a conceptual shift for optimizing multipoint queries, and we anticipate that it can be readily adapted to similar problems in particle accelerators and other scientific instruments.

43 PARTICLE ACCELERATORS↗

Demonstration of Single-Crystal Self-Seeded Two-Color X-Ray Free-Electron Lasers

A scheme for generating two simultaneous hard-x-ray free-electron laser pulses with a controllable difference in photon energy is described and then demonstrated using the self-seeding setup at the Linac Coherent Light Source (LCLS). The scheme takes advantage of the existing LCLS equipment, which allows two independent rotations of the self-seeding diamond crystal. The two degrees of freedom are used to select two nearby crystal reflections, causing two wavelengths to be present in the forward transmitted seeding x-ray pulse. The free-electron laser system must support amplification at both desired wavelengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)↗

A revised partiality model and post-refinement algorithm for X-ray free-electron laser data

An updated partiality model and post-refinement algorithm for XFEL snapshot diffraction data is presented and confirmed by observing anomalous density for S atoms at an X-ray wavelength of 1.3 Å. Research towards using X-ray free-electron laser (XFEL) data to solve structures using experimental phasing methods such as sulfur single-wavelength anomalous dispersion (SAD) has been hampered by shortcomings in the diffraction models for X-ray diffraction from FELs. Owing to errors in the orientation matrix and overly simple partiality models, researchers have required large numbers of images to converge to reliable estimates for the structure-factor amplitudes, which may not be feasible for all biological systems. Here, data for cytoplasmic polyhedrosis virus type 17 (CPV17) collected at 1.3 Å wavelength at the Linac Coherent Light Source (LCLS) are revisited. A previously published definition of a partiality model for reflections illuminated by self-amplified spontaneous emission (SASE) pulses is built upon, which defines a fraction between 0 and 1 based on the intersection of a reflection with a spread of Ewald spheres modelled by a super-Gaussian wavelength distribution in the X-ray beam. A method of post-refinement to refine the parameters of this model is suggested. This has generated a merged data set with an overall discrepancy (by calculating the R{sub split} value) of 3.15% to 1.46 Å resolution from a 7225-image data set. The atomic numbers of C, N and O atoms in the structure are distinguishable in the electron-density map. There are 13 S atoms within the 237 residues of CPV17, excluding the initial disordered methionine. These only possess 0.42 anomalous scattering electrons each at 1.3 Å wavelength, but the 12 that have single predominant positions are easily detectable in the anomalous difference Fourier map. It is hoped that these improvements will lead towards XFEL experimental phase determination and structure determination by sulfur SAD and will generally increase the utility of the method for difficult cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source

A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal, with a thickness of ~100 µm, provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. This article reports the design, fabrication and X-ray characterization of the first and second (300 µm-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 × 2 mm with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 × 2 mm working regions of the crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low- Z polymer sample supports for fixed-target serial femtosecond X-ray crystallography

X-ray free-electron lasers (XFELs) offer a new avenue to the structural probing of complex materials, including biomolecules. Delivery of precious sample to the XFEL beam is a key consideration, as the sample of interest must be serially replaced after each destructive pulse. The fixed-target approach to sample delivery involves depositing samples on a thin-film support and subsequent serial introduction via a translating stage. Some classes of biological materials, including two-dimensional protein crystals, must be introduced on fixed-target supports, as they require a flat surface to prevent sample wrinkling. A series of wafer and transmission electron microscopy (TEM)-style grid supports constructed of low- Z plastic have been custom-designed and produced. Aluminium TEM grid holders were engineered, capable of delivering up to 20 different conventional or plastic TEM grids using fixed-target stages available at the Linac Coherent Light Source (LCLS). As proof-of-principle, X-ray diffraction has been demonstrated from two-dimensional crystals of bacteriorhodopsin and three-dimensional crystals of anthrax toxin protective antigen mounted on these supports at the LCLS. In conclusion, the benefits and limitations of these low- Z fixed-target supports are discussed; it is the authors' belief that they represent a viable and efficient alternative to previously reported fixed-target supports for conducting diffraction studies with XFELs.

59 BASIC BIOLOGICAL SCIENCES↗

The matter in extreme conditions instrument at the Linac Coherent Light Source

The LCLS beam provides revolutionary capabilities for studying the transient behavior of matter in extreme conditions. The particular strength of the Matter in Extreme Conditions instrument is that it combines the unique LCLS beam with high-power optical laser beams, and a suite of dedicated diagnostics tailored for this field of science. In this paper an overview of the beamline, the capabilities of the instrumentation, and selected highlights of experiments and commissioning results are presented.

43 PARTICLE ACCELERATORS↗

X-ray detectors at the Linac Coherent Light Source

Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced.

43 PARTICLE ACCELERATORS↗

Optical laser systems at the Linac Coherent Light Source

Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump–probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump–probe experiments to be performed at LCLS.

42 ENGINEERING↗

Optimizing X-ray mirror thermal performance using matched profile cooling

To cover a large photon energy range, the length of an X-ray mirror is often longer than the beam footprint length for much of the applicable energy range. To limit thermal deformation of such a water-cooled X-ray mirror, a technique using side cooling with a cooled length shorter than the beam footprint length is proposed. This cooling length can be optimized by using finite-element analysis. For the Kirkpatrick–Baez (KB) mirrors at LCLS-II, the thermal deformation can be reduced by a factor of up to 30, compared with full-length cooling. Furthermore, a second, alternative technique, based on a similar principle is presented: using a long, single-length cooling block on each side of the mirror and adding electric heaters between the cooling blocks and the mirror substrate. The electric heaters consist of a number of cells, located along the mirror length. The total effective length of the electric heater can then be adjusted by choosing which cells to energize, using electric power supplies. The residual height error can be minimized to 0.02 nm RMS by using optimal heater parameters (length and power density). Compared with a case without heaters, this residual height error is reduced by a factor of up to 45. The residual height error in the LCLS-II KB mirrors, due to free-electron laser beam heat load, can be reduced by a factor of ~11 below the requirement. The proposed techniques are also effective in reducing thermal slope errors and are, therefore, applicable to white beam mirrors in synchrotron radiation beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗