At least 595 records · Page 33

Highly Efficient Regeneration Module for Carbon Capture Systems in NGCC Applications

The objective of this project is to design, fabricate, and test a highly efficient regeneration module capable of providing an ultra-lean absorption solution that is required for capturing CO 2 from dilute sources at 95% or better efficiency. By integrating this advanced regenerator module with SRI International’s Mixed Salt Process (MSP) absorption modules, SRI expects to demonstrate significant progress toward a reduction in cost of capture versus the DOE reference natural gas combined cycle (NGCC) plant with carbon capture. SRI designed, built, and tested an advanced stripper to enhance the performance of SRI’s MSP for CO 2 capture – a transformational ammonia-based solvent technology – for natural gas (NG) power sources. The testing of the advanced stripper for MSP was conducted at an SRI site using a simulated flue gas stream equivalent to about 10 kWe. The research work included modeling of the advanced stripper and integrating it with the MSP absorbers; studying the strategies for producing very highly alkaline lean solvent with minimized emissions; operating the stripper with advanced heat integration to improve process efficiencies; and collecting critically important data for a detailed techno-economic analysis (TEA). The project tasks were designed to address concerns relating to scale-up and integration of the technology to NG power plants—more specifically, to maximize the carbon capture efficiency achievable with MSP and identify pathways to achieve higher capture efficiencies and ultimately zero net carbon emissions. SRI teamed up with a process modeling company (OLI Systems), a process and chemical engineering company (Trimeric Corporation), and a cost-sharing commercial partner (Baker-Hughes – a leading multinational company that designs, manufactures, and services transformative energy technologies) to execute the project. The research findings will accelerate the MSP development and pave the way for the technology to reach the DOE’s goal, and ultimately commercialization of the MSP technology for low-cost CO 2 capture from NGCC flue gas and other dilute CO 2 sources.

03 NATURAL GAS↗

Integration of Condition-Based, Diagnostic, Prognostic, And Anomaly Detection Data into Reliability Models to Support a Predictive Maintenance Context

Reliability data employed in plant reliability models are an approximated integral representation of the past industrywide operational experience, and they neglect the present asset health status (available, for example, from online monitoring data and diagnostic assessments) and forecasted health projection (when available from prognostic models). Ideally, in a predictive maintenance context, system reliability models should support decision making by propagating actual health information from the asset to the system level in order to provide a quantitative snapshot of system health and identify the most critical assets. Asset health should be informed solely by that specific asset’s current and historical performance data and should not be an approximated integral representation of the past industrywide operational experience (as currently performed by system reliability models through Bayesian updating processes). This paper proposes a reliability modeling approach that relies on asset diagnostic and prognostic assessments, along with monitoring data to measure asset health. We show how state-of-the art condition-based, diagnostic, prognostic, and anomaly detection models can be linked to system reliability models not in probability terms, but in terms of margin where margin is defined as the “distance” between the present status and an undesired event (e.g., failure or unacceptable performance). Then, we show how the propagation of margin data from the asset to the system level is performed through classical reliability models such as fault trees or reliability block diagrams. The described method is in fact able to propagate heterogenous health data from the asset to the system level in order to analytically assess system health.

97 MATHEMATICS AND COMPUTING↗

Enhanced Control, Optimization, and Integration of Distributed Energy Applications (ECO-IDEA)

With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative techno-economic and environmental analysis of using nuclear energy and fossil energy with carbon sequestration in U.S. Gulf Coast petroleum refineries

U.S. Gulf Coast refineries have processing capacity of approximately 9.4 million barrels of crude oil per day—about 50% of U.S. national capacity—while consuming natural gas, electricity, and hydrogen, resulting in approximately 100 million metric tonnes (MMT) of onsite CO₂ emissions in 2022. This study evaluates two alternative refinery energy supply pathways: nuclear energy (NE) and fossil energy-derived hydrogen with carbon capture and sequestration (FE-CCS; autothermal reforming), intermittent renewable sources are not considered as they cannot reliably meet continuous industrial heat and hydrogen demands. Using publicly available data for refineries, we conducted a bottom-up, facility-level assessment to estimate energy use by type, well-to-gate refinery emissions, and associated costs of integration. Compared to current refinery operations using natural gas energy supply and conventional hydrogen production (steam methane reforming without sequestration), NE and FE-CCS could produce, respectively, average emissions reductions of 37% and 42%, total abatement costs of $\$$52–$\$$221 and $\$$211–$\$$612/MT CO₂, and additional costs of about $\$$0.2–$\$$6 and $\$$3–$\$$11 per barrel of crude, respectively. Our analysis indicates that 25 out of 27 refineries have lower total additional cost ($\$$/bbl.) for the NE scenario than the FE-CCS scenario, making a strong case for NE integration with petroleum refineries. This work's main contribution is a detailed bottom-up refinery-level analysis method that can be utilized by the worldwide refining industry and stakeholders as they assess different technological options, along with their costs and environmental impacts for a specific refinery operation.

Carbon capture and sequestration↗

Grid Architecture Mapping to Understand Transformation (GAMUT): Concept Definition

The electric power system is undergoing significant transformation driven by changes in the generation mix, increasing reliance on information and communication technologies, evolving customer expectations, and a dynamic cyber-physical environment. To address these challenges, substantial investments will be made over the next decade to create a flexible, affordable, secure, reliable, and resilient electric system. In response, the U.S. Department of Energy's Office of Electricity is developing knowledge management tools aimed at systematically documenting technology pilots and demonstration projects. This initiative seeks to improve understanding of operating contexts, planning steps, and integration requirements for innovative grid technologies. The Department of Energy project leverages Grid Architecture principles to collect and organize insights into the interdependencies, requirements, and capabilities of various grid solutions. By employing a systematic approach, the project aims to perform a feasibility study for the development of a software tool that will support stakeholders, including regulators, transmission and distribution system operators, distributed energy resources aggregators, and technology providers. By offering a systematic, software-based framework to document technologies, understand their benefits and impacts, and inform deployment strategies, the proposed Grid Architecture Mapping to Understand Transformation (GAMUT) Tool is intended to reduce costs, enhance decision-making, and facilitate scaling and effective deployment of new technologies. The feasibility study will evaluate the technical and financial viability of the GAMUT Tool, identifying stakeholder needs and assessing risks and mitigation strategies. Ultimately, the GAMUT team aims to develop an initial minimal viable product, followed by staged improvements, to aid in the modernization of the electric grid, contributing to a more sustainable and resilient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Learning-Based Adaptive Remedial Action Scheme with Security Margin for Renewable-Dominated Power Grids

The Remedial Action Scheme (RAS) is designed to take corrective actions after detecting predetermined conditions to maintain system transient stability in large interconnected power grids. However, since RAS is usually designed based on a few selected typical operating conditions, it is not optimal in operating conditions that are not considered in the offline design, especially under frequently and dramatically varying operating conditions due to the increasing integration of intermittent renewables. The deep learning-based RAS is proposed to enhance the adaptivity of RAS to varying operating conditions. During the training, a customized loss function is developed to penalize the negative loss and suggest corrective actions with a security margin to avoid triggering under-frequency and over-frequency relays. Simulation results of the reduced United States Western Interconnection system model demonstrate that the proposed deep learning–based RAS can provide optimal corrective actions for unseen operating conditions while maintaining a sufficient security margin.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

On the equivalence between SRS and PCO formulations of superstring perturbation theory

We establish the equivalence between two formulations of superstring perturbation theory, one based on integration over the supermoduli space of super Riemann surfaces (SRS), the other based on integration over the bosonic moduli space with insertions of picture changing operators (PCO) on the worldsheet and the vertical integration prescription, by showing how the latter arises from a specific construction of the supermoduli integration contour.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Verification of Spent Fuel Inside Dry Storage Casks by Cask Top Fast Neutron Mapping (FY2023 Mid-Year Report)

This project is developing a prototype scanner array verification system for detection of missing fuel assemblies in spent-fuel storage casks. The prototype consists of six fast-neutron scintillator detectors mounted to a linear actuator frame that is placed on the top of a spent fuel cask to scan across all fuel assembly positions. The scanner array was assembled and tested at LLNL in FY2022. A field test schedule has been requested at the Idaho National Laboratory (INL) Cask Farm site for FY2023. Note that the Cask Farm contractor determines this scheduling and not INL directly. Further system automation will be designed and implemented with the goal of obtaining a level of system operation that meets IAEA needs. This includes integration of the scanner array and data-acquisition control software into a single interface for operator use. In addition, commercial operators and the IAEA may have special requirements for portability, shipping, lifting, and installation. Prior to the Field Test at INL, the system will be operated at LLNL to exercise lifting procedure and linear actuators, monitor stability of detector energy and pulse-shape discrimination calibration, and test system software integration efforts. Following the Field Test, we will present results and discuss the technology with the IAEA. We will incorporate additional improvements to the system based on lessons learned from the field test and feedback from the IAEA. If successful, the technology can be transferred to the IAEA or other stakeholders for assessment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Update on the Status of a Reduced Flow Test of a 10MW 700°C sCO2 Integrally Geared Compander

. In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 degrees Celsius. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale concentrated solar power (CSP) supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications. As part of the commercialization of this technology, it is necessary to reduce risk by validation testing of key components. In the current work, the focus is developing a test loop to enable safe testing of the main compressor stage across a wide range of operating conditions, and to validate the mechanical integrity of the turbine at full pressure, temperature, and speed. Developing a test loop for sCO2 requires balancing a number of design alternatives that impact cost, lead time, safety, and performance. The current work discusses the design process for the reduced flow test loop for the compander, and supporting documentation supporting the viability of the test loop

wilkes, jason↗

On Distribution Grid Optimal Power Flow Development and Integration

Due to changes in electric distribution grid operation, new operation regimes have been recommended. Distribution grid optimal power flow (DOPF) has received tremendous attention in the research community, yet it has not been fully adopted across the utility industry. Our paper recognizes this problem and suggests a development and integration procedure for DOPF. We propose development of DOPF as a three step procedure of 1) processing the grid, 2) obtaining a tractable solution, and 3) implementing multiple solution algorithms and benchmarking them to improve application reliability. For the integration of DOPF, we demonstrate how a DOPF federate may be developed that can be integrated in a co-simulation environment to mimic the real-world conditions and hence improve its practicality to be deployed in the field. To demonstrate the efficacy of the proposed methods, tests on IEEE 123 bus system are performed where the usage of tractable formulation in DOPF algorithm development and its comparison to the benchmark solution are demonstrated.

Hanif, Sarmad↗

Optimal Electric Grid Black Start Restoration Subject to Intentional Threats

Efficient restoration of the electric grid from significant disruptions – both natural and manmade – that lead to the grid entering a failed state is essential to maintaining resilience under a wide range of threats. Restoration follows a set of black start plans, allowing operators to select among these plans to meet the constraints imposed on the system by the disruption. Restoration objectives aim to restore power to a maximum number of customers in the shortest time. Current state-of-the-art for restoration modeling breaks the problem into multiple parts, assuming a known network state and full observability and control by grid operators. These assumptions are not guaranteed under some threats. This paper focuses on a novel integration of modeling and analysis capabilities to aid operators during restoration activities. A power flow-informed restoration framework, comprised of a restoration mixed-integer program informed by power flow models to identify restoration alternatives, interacts with a dynamic representation of the grid through a cognitive model of operator decision-making, to identify and prove an optimal restoration path. Application of this integrated approach is illustrated on exemplar systems. Validation of the restoration is performed for one of these exemplars using commercial solvers, and comparison is made between the steps and time involved in the commercial solver, and that required by the restoration optimization in and of itself, and by the operator model in acting on the restoration optimization output. Publications and proposals developed under this work, along with a path forward for additional expansion of the work, and summary of what was achieved, are also documented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗

Integrated quantum optical phase sensor in thin film lithium niobate

Abstract The quantum noise of light, attributed to the random arrival time of photons from a coherent light source, fundamentally limits optical phase sensors. An engineered source of squeezed states suppresses this noise and allows phase detection sensitivity beyond the quantum noise limit (QNL). We need ways to use quantum light within deployable quantum sensors. Here we present a photonic integrated circuit in thin-film lithium niobate that meets these requirements. We use the second-order nonlinearity to produce a squeezed state at the same frequency as the pump light and realize circuit control and sensing with electro-optics. Using 26.2 milliwatts of optical power, we measure (2.7 ± 0.2)% squeezing and apply it to increase the signal-to-noise ratio of phase measurement. We anticipate that photonic systems like this, which operate with low power and integrate all of the needed functionality on a single die, will open new opportunities for quantum optical sensing.

47 OTHER INSTRUMENTATION↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗