Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inlet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Model validation using CFD-grade experimental database for NGNP Reactor Cavity Cooling Systems with water and air

This project has been focused on the experimental and numerical investigations of the water-cooled and air-cooled Reactor Cavity Cooling System (RCCS) designs. At this aim, we have leveraged an existing experimental facility at the University of Wisconsin-Madison (UW), and we have designed and built a separate effect test facility at the University of Michigan. The experimental facility at UW has underwent several upgrades, including the installation of advanced instrumentation (i.e. wire-mesh sensors) built at the University of Michigan. These provides highresolution time-resolved measurements of the void-fraction distribution in the risers of the water-cooled RCCS facility. A phenomenological model has been developed to assess the water cooled RCCS system stability and determine the root cause behind the oscillatory behavior that occurs under normal two-phase operation. Testing under various perturbations to the water-cooled RCCS facility have resulted in changes in the stability of the integral system. In particular, the effects on stability of inlet orifices, water tank volume have and system pressure been investigated. MELCOR was used as a predictive tool when performing inlet orificing tests and was able to capture the Density Wave Oscillations (DWOs) that occurred upon reaching saturation in the risers. The experimental and numerical results have then been used to provide RCCS design recommendations. The experimental facility built at the University of Michigan was aimed at the investigation of mixing in the upper plenum of the air-cooled RCCS design. The facility has been equipped with state-of-theart high-resolution instrumentation to achieve so-called CFD grade experiments, that can be used for the validation of Computational Fluid Dynanmics (CFD) models, both RANS (Reynold-Averaged) and LES (Large Eddy Simulations). The effect of risers penetration in the upper plenum has been investigated as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data Driven Smart Proxy for CFD Application of Big Data Analytics & Machine Learning in Computational Fluid Dynamics, Report Two: Model Building at the Cell Level

To ensure the usefulness of simulation technologies in practice, their credibility needs to be established with Uncertainty Quantification (UQ) methods. In this project, smart proxy is introduced to significantly reduce the computational cost of conducting large number of multiphase CFD simulations, which is typically required for non-intrusive UQ analysis. Smart proxy for CFD models are developed using pattern recognition capabilities of Artificial Intelligence (AI) and Data Mining (DM) technologies. Several CFD simulation runs with different inlet air velocities for a rectangular fluidized bed are used to create a smart CFD proxy that is capable of replicating the CFD results for the entire geometry and inlet velocity range. The smart CFD proxy is validated with blind CFD runs (CFD runs that have not played any role during the development of the smart CFD proxy). The developed and validated smart CFD proxy generates its results in seconds with reasonable error (less than 10%). Upon completion of this project, UQ studies that rely on hundreds or thousands of smart CFD proxy runs can be accomplished in minutes. Following figure demonstrates a validation example (blind CFD run) showing the results from the MFiX simulation and the smart CFD proxy for pressure distribution across a fluidized bed at a given time-step (the layer number corresponds to the vertical location in the bed).

97 MATHEMATICS AND COMPUTING↗

Data Driven Smart Proxy for CFD Application of Big Data Analytics & Machine Learning in Computational Fluid Dynamics, Part Three: Model Building at the Layer Level

To ensure the usefulness of simulation technologies in practice, their credibility needs to be established with Uncertainty Quantification (UQ) methods. In this project smart proxy is introduced to significantly reduce the computational cost of conducting large number of multiphase CFD simulations. Smart proxy for CFD models are developed using pattern recognition capabilities of Artificial Intelligence (AI), Machine Learning (LM) and Data Mining (DM) technologies. Several CFD simulation runs with different inlet air velocities for a rectangular fluidized bed are used to create a smart CFD proxy that is capable of replicating the CFD results for a wide variety of inlet velocities. The smart CFD proxy is validated with blind CFD runs (CFD runs that have not played any role during the development [training, calibration and validation] of the smart CFD proxy). In our earlier work, CFD data was used to train ANN at the cell level. That is an ANN was trained for each computational cell used in the CFD simulations. In the present work, the ANN is constructed and trained based on cross sectional area average of each variable, such as pressure, velocities and volume fraction (Layer Level). This leads to improvements in the training time at the expense of less spatial resolution. The resulting trained ANN provides spatially average value of parameters of interest, along the length of the fluidized bed. Upon completion of this project, UQ studies that rely on hundreds or thousands of smart CFD proxy runs can be accomplished in minutes. Following figure demonstrates a validation example (blind CFD run) showing the results from the MFiX and the smart CFD proxy for pressure drop across a fluidized bed at time-step of 1400 (the layer number corresponds to the vertical location in the bed).

97 MATHEMATICS AND COMPUTING↗

Closure Report for the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

Because of significantly reduced wastewater discharges to the Central Facilities Area Sewage Treatment Plant, wastewater has not been land applied since 2011. The future need to land apply wastewater was evaluated. Based on the current wastewater flows into the Central Facilities Area Sewage Treatment Plant, expected future missions at Central Facilities Area, and the discovery in 2014 that Lagoon 3 was leaking at an unacceptable rate, it was determined that the Central Facilities Area Sewage Treatment Plant is significantly oversized and that Lagoons 1 and 2 could be converted to total evaporation lagoons. Therefore, the decision was made to remove the existing sludge in Lagoon 3 and transfer it to Lagoon 2 for additional treatment, decommission Lagoon 3 and the land application area, and terminate the wastewater reuse permit. A closure plan was submitted and approved by the Idaho Department of Environmental Quality in 2016. This report describes the closure activities that were performed. Closure activities included: • Characterizing the soil/liner in Lagoon 3 to determine whether further characterization and/or remediation will be required under the Comprehensive Environmental Response, Compensation, and Liability Act. • Based on the results from the soil/liner sampling, determining whether additional sampling will be required for the land application area. • Removing the sludge in Lagoon 3 and placing it in Lagoon 2. • Puncturing the Lagoon 3 soil/liner to prevent ponding of storm water and becoming a source for vectors. • Installing a permanent cap on the inlet piping to Lagoon 3. Samples were collected on November 10, 2016, and were submitted for analysis to an off-site laboratory. Data validation and evaluation were performed by Portage, INC. Sample results confirmed that there is no hazard to human health and the environment and that Lagoon 3 and the land application area could be closed. In August 2017, sludge was removed from Lagoon 3 and placed in Lagoon 2, the soil/liner was punctured in 4 places, and caps were installed on the primary and bypass inlet lines.

99 GENERAL AND MISCELLANEOUS↗

Storm Surge Modeling in Puget Sound

In this study, a storm surge model of the Salish Sea was developed to simulate storm surge in Puget Sound using the unstructured-grid, finite-volume community ocean model (FVCOM). The model was based on Pacific Northwest National Laboratory’s existing Puget Sound hydrodynamic model that has been validated extensively in previous studies. To identify representative historical storm events, a systematic approach was developed based on the non-tidal residual (NTR) method. A total of 34 storm surge events between 1980 and 2016 were identified and simulated. To accurately simulate storm surge inside Puget Sound, the model was driven by reanalyzed Climate Forecast System Reanalysis meteorological forcing and observed water levels at the entrance of Strait of Juan de Fuca and southern entrance of Johnstone Strait. Model results for total water level, storm surge, and currents were compared with field measurements. A series of error statistics parameters were also calculated to quantify the model’s skills in simulating storm surge in the Salish Sea. Error statistics of model performance metrics demonstrated that the Salish Sea storm surge model was able to simulate storm surge inside Puget Sound with high accuracy. Storm surge propagation into Puget Sound is a nonlinear process that cannot be simply determined by a static approach for the entire domain. The maximum NTR distribution inside Puget Sound suggests that storm surge tends to be amplified in several sub-basins and inlets of the Puget Sound, such as Bellingham Bay, Hood Canal, south Puget Sound, and the multi-inlet basin behind Agate and Rich Passages. Therefore, future study is necessary to further quantify the storm surge level in these high-risk areas through field measurements and refined model simulations.

16 TIDAL AND WAVE POWER↗

Fluidization of Group A Glass Particles: Experiments and Preliminary Validation

This work is aimed at providing reliable high-quality data from fluidization experiments. Geldart Group A glass beads are used as bed material. The fluidizing medium is air at atmospheric pressure which enters the system at 40% relative humidity. The air inlet velocity is varied over a broad range from 2 U mf to 26 U mf , where the minimum fluidization velocity, U mf , is 0.608 cm/s. There is not a significant change in the mean values of differential pressure; however, there are noticeable trends in their standard deviation values. Preliminary validation studies are performed using the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). The results from Eulerian-Eulerian (MFiX-TFM, two-fluid model) and Eulerian-Lagrangian (MFiX-PIC, particle-in-cell) formulations are compared. The work presented in this report highlights the applicability of MFiX-PIC for large-scale applications, and reveals that PIC simulation offers a suitable alternative to TFM simulation when effects due to multiple components or polydispersity are significant. PIC modeling provides a readily extendible framework for such systems. However, PIC models do rely on an empirical closure for inter-particle stress. Some solution discrepancies were evident in MFiX-PIC predictions which require further analysis. As such, the study underlines the need for a systematic approach to quantify the sources of numerical uncertainty within the PIC model. However, even with known empiricism, MFiX-PIC has demonstrated considerable potential in analyzing gas-solid systems. The results obtained are encouraging and warrant further investigation to improve the predictive capability of MFiX-PIC.

36 MATERIALS SCIENCE↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

ECAR-5067 Computational Evaluation on Effect of Edge-rounding in Circular to Annular Flow Transitions within a Hexagonal Duct

In this ECAR, the computational fluid dynamics (CFD) simulation of the duct with a cross-section varying from circle to annulus was performed to evaluate the effect of edge-rounding of the internal edges. The edge of circular channel and the edge of inner annular channel were rounded with the radius of curvature ranged from 0 mm to 20 mm. The CFD results show that the pressure loss of the duct can be reduced by increasing the radius of the rounded edge. Case-A results showed that the pressure drop can be significantly reduced by the edge-rounding, e.g., the pressure drop was reduced approximately 56% by the radius of curvature of 5.0mm, and reduced 70% by the radius of curvature of 20.0 mm although its effectiveness would be attenuated as the radius of curvature of edge increases. Results from Case-B showed the impact of rounding the inlet edge was practically negligible compared to the outlet edge. This ECAR could provide a guideline to determine the optimum inlet module design of the VTR fuel rod bundle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Silicon Carbide Multilayer Piping for 900°C Supercritical CO 2 Brayton Cycle: Chemical Compatibility in CO 2

The US Department of Energy's Office of Nuclear Energy is interested in developing supercritical carbon dioxide (sCO 2 ) power cycles that can achieve higher cycle efficiencies and lower costs than the traditional steam Rankine cycles. For the application of an sCO2 energy conversion system with a Very High Temperature Gas Reactor (VHTGR), turbine inlet temperatures over 850°C may be required. Consequently, it is necessary to demonstrate structural materials, including turbine inlet piping, that can be code certified at operating temperatures up to 900°C at sCO 2 pressures up to 42 MPa (6100 psi). There are very few metal alloys that retain their strength at these high temperatures, and that are chemically compatible with sCO 2 .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

KIPT ADS Target Cooling Analyses by MCNP/Fluent

This report presents multi-physics analyses of the target cooling system of the accelerator driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target using a mesh-tally. The mesh-tally data have been imported in Fluent by a C subroutine that has been compiled and linked to Fluent as a user defined function. The KIPT ADS is in operation and Fluent used the CAD model from the manufacturing process of the target. The Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator control or the primary water coolant pump. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. If the water coolant mass flow decreases to 25%, the water maximum temperature exceeds the boiling point. However, the transient analysis showed that the target cooling system can operate for 180 seconds when the inlet water mass flow rate is decreased down by 50%.

42 ENGINEERING↗

Thermal-Hydraulics Modeling and Simulations of Hot Pool Using the SAS-CFD Coupled Code

The main goal of this activity is to test the dynamic coupling of the SAS4A/SASSYS-1 (SAS) and CFD models, using a recently patched version of the SAS code intended to address an undocumented limitation that hindered the Versatile Test Reactor (VTR) simulation efforts in FY21. As described in previous VTR calculation reports, the undocumented limitation in SAS v5.4 does not allow the user to activate the CFD coupling option during restart calculations. Since the analysts were unaware of this limitation, prior SAS-CFD simulation results for the protected station blackout (PSBO) transient were erroneous. Root-cause analysis was performed to determine the cause of this undocumented limitation in SAS v5.4, the SAS software was updated in a new patch, and the SAS-CFD simulations were repeated with this patched software. The results of the SAS-CFD simulations documented in this report show that the software patch does address the cited issue, and that the patched software indeed supports the activation of the CFD coupling model in restart calculations. The SAS development team will determine the schedule for implementing the patch in an official software release. This report documents updated SAS-CFD simulations of the PSBO transient response in the VTR. The hot pool is modeled with the CFD code STAR-CCM+, which is coupled at the flow boundaries to the SAS model of the primary heat transport system. SAS computes the mass flow rate and temperature at each core subassembly outlet, the thermal insulation cavity bypass, and the IHX inlet windows. CFD in turn computes the absolute pressure and temperature at each of these boundaries. The SAS code will ignore the temperature data at flow boundaries where flow is directed into the hot pool, i.e., at the core subassembly outlets unless flow reversal occurs. Similarly, CFD will ignore temperature data at boundaries where the flow is directed out of the hot pool, i.e., at the IHX inlets except under flow reversal. The focus of this work is to ensure that the SAS software patch addresses the undocumented limitation described in prior VTR calculation reports, rather than the accurate assessment of thermal stratification in the VTR during protected transients. This motivates the development of a new, simplified CFD model with a coarser mesh to accelerate the testing process. The updated model, and simplifying assumptions, are documented in this report. In future work, the thermal stratification assessment should be performed in more detail. The simplified CFD model can be improved by performing grid convergence studies sensitivity studies of turbulence parameters (e.g., Prandtl number, turbulence production and dissipation parameters) on temperature distributions and thermal stratification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of NEAMS Tools Using MSRE Data

This report documents the benchmarks developed and performed for the tools and codes developed under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program utilizing the MSRE experiment data. There are three focus areas explored in this work: fuel evolution, CFD, and system transient analyses. Fuel depletion is important for MSR reactor physics and fuel cycle analysis. Fuel depletion capability is currently being developed in the Griffin reactor physics code. To support this, a benchmark problem is developed using the MSRE data and an existing depletion code with flowing fuel analysis functionality (ADDER) to validate this new capability in Griffin. The ADDER calculation is compared with the TRITON-MSR results as well as the MSRE experimental data. This benchmark can be directly used to verify and validate the Griffin fuel depletion capability in future years. For CFD simulation, the MSRE CAD model is obtained from the Copenhagen Atomics and a mesh is generated for the MSRE inlet plenum. The Nek5000 code will be employed to find the flow distribution in the MSRE inlet plenum based on the mesh generated. For system analysis, a simple benchmark problem for three types of MSR system transients is developed. The SAM and SPECTRA codes are used to solve the simple problem, and the results from the two codes agree well. The SAM code is also employed to obtain the frequency response of the MSRE system at the 5 and 8 MWt power levels. The results agree well with the experiment measurements. These verification and validation efforts gives SAM users more confidence in MSR system transient simulations using SAM. Lastly, the SAM-Griffin Multiphysics coupling work is initiated. A simple one-way coupling of evaluating the precursor drift effect on the MSRE k-eff is demonstrated. This preliminary coupling work serves as the basis for future more complex Multiphysics simulation and modelling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of Reactor Design and Optimization for Scale-Up of the Catalyxx Process for Ethanol Conversion to Higher Alcohol Biofuels

This report summarizes the results of a collaborative efforts between Oak Ridge National Laboratory (ORNL) and Catalyxx Inc. to investigate scale-up of Catalyxx’s Ethanol upgrading to higher alcohols process. The study was funded by the U.S. Department of Energy (DOE) Bioenergy Technologies Office (BETO) under CRADA (Cooperative Research and Development Agreement) No: NFE-20-08396. The project is part of the Direct Funding Opportunity (DFO) for Computational Science to Enable Bioenergy program which utilized computational toolsets developed by the Consortium for Computational Physics and Chemistry, a multi-laboratory consortium in BETO. The report here summarizes a packed-bed reactor modeling effort spanning the range from lab to industrial scale (from 4 gram to 5-ton catalyst beds), and examining reactor design, process optimization strategies, and suggested design and operating conditions for Catalyxx’s ethanol upgrading plants. The results in this report have been shared in monthly steering meetings and presentations are available in the shared data house owned by Catalyxx. The modeling effort helped to define optimum operation conditions for maximum alcohol selectivity and yield: i.e., temperature control scenarios ranging from adiabatic to isothermal, feed rate, pressure, and inlet H 2 /Ethanol ratio. The modeling results were verified at lab-(4 gram) and pre-pilot (4 kg) scales and has been used to evaluate a 5-ton packed-bed reactor and identify operating conditions to maximize the butanol yield. Special focus was given to understanding mass-transfer effects in the pre-pilot and pilot-scale reactors, over the domain of flow rate, pressure, feed composition, pellet size, shape, porosity, bed voidage, and reactor dimensions (i.e., length/diameter). Modeling was also used to evaluate innovative reactor design concepts such as water removal to improve alcohol selectivity and yield, and a reactor with an additional side inlet to facilitate quenching. These concepts were thoroughly explored, and potential benefits were disclosed. The results in this report are summarized and described qualitatively to protect the IP rights of Catalyxx. The details have been shared with the Catalyxx team in the regular steering meetings. At the end of the project, Catalyxx Inc. announced a successful demonstration of pilot scale operation in Seville, Spain.

02 PETROLEUM↗

Flow rate optimization for a small liquid argon system at Fermilab.

This analysis highlights the dominant role of pressure loss in filter disks, emphasizing its crucial consideration during the design phase to ensure optimal fluid flow. Additionally, the significance of vapor quality at the transfer line inlet is identified as a key factor impacting the fill rate. Reducing inlet vapor quality and exploring the use of subcooled liquid are recommended approaches to enhance system performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Oil‐Free, High-Temperature Heat Transfer Fluid Circulator

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗