Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Illuminator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Imaging Radar Applications in the Death Valley Region

Death Valley has had a long history as a testbed for remote sensing techniques (Gillespie, this conference). Along with visible-near infrared and thermal IR sensors, imaging radars have flown and orbited over the valley since the 1970's, yielding new insights into the geologic applications of that technology. More recently, radar interferometry has been used to derive digital topographic maps of the area, supplementing the USGS 7.5' digital quadrangles currently available for nearly the entire area. As for their shorter-wavelength brethren, imaging radars were tested early in their civilian history in Death Valley because it has a variety of surface types in a small area without the confounding effects of vegetation. In one of the classic references of these early radar studies, in a semi-quantitative way the response of an imaging radar to surface roughness near the radar wavelength, which typically ranges from about 1 cm to 1 m was explained. This laid the groundwork for applications of airborne and spaceborne radars to geologic problems in and regions. Radar's main advantages over other sensors stems from its active nature- supplying its own illumination makes it independent of solar illumination and it can also control the imaging geometry more accurately. Finally, its long wavelength allows it to peer through clouds, eliminating some of the problems of optical sensors, especially in perennially cloudy and polar areas.

Farr, Tom G.↗

The Use of Vegetation For Estimating Broken-Cloud Optical Properties From Surface Measurements

It is known that because of complex three-dimensional (3D) radiative effects of broken clouds, the retrieval of cloud optical properties from upward measurements based on a one-dimensional (1D) inversion technique almost surely fails. To remove radiative effects of 3D cloud structure, we have developed a new technique that retrieves cloud optical thickness for broken clouds above green vegetation from simultaneous surface measurements in the VIS and Near Infrared (NIR) spectral regions. The theoretical basis of the method is the very different spectral behavior of cloud liquid water drops and green vegetation. For example, cloud optical properties, and hence cloud reflectivities, change little between 650 and 860 nm, while the vegetated surface albedo changes from 0.05 to 0.5 between the same two wavelengths. This spectral contrast in surface albedo suggests using ground measurements at both wavelengths not independently, but as an algebraic combination (a spectral index). For a spectral band in the NIR region, the green vegetation acts as a powerful reflector that "illuminates" horizontally inhomogeneous clouds from below. This provides the extra information needed to largely remove the 3D radiative effects, especially in the case of broken clouds; this in turn allows the retrieval of cloud optical depth using traditional 1D radiative transfer theory. This approach is similar to the so-called Green's function problem for radiative transfer where a laser beam illuminates clouds and the resulting "spot-size" of the reflected light around the beam characterizes cloud properties. We generalize Green's function theory to surf ace-cloud interaction and develop new spectral indices from which broken-cloud optical depth can be retrieved.

Marshak, A.↗

Molecular Hydrogen in Diffuse Interstellar Clouds of Arbitrary Three-Dimensional Geometry

We have constructed three-dimensional models for the equilibrium abundance of molecular hydrogen in diffuse interstellar clouds of arbitrary geometry that are illuminated by ultraviolet radiation. The position-dependent photodissociation rate of H2 in such clouds was computed with a 26 ray approximation to model the attenuation of the incident ultraviolet radiation field by dust and by H2 line absorption. We have applied our modeling technique to the isolated diffuse cloud G236+39, assuming that the cloud has a constant density and that the thickness of the cloud along the line of sight is at every point proportional to the 100 micron continuum intensity measured by IRAS. We find that our model can successfully account for observed variations in the ratio of 100 micron continuum intensity to H I column density, with larger values of that ratio occurring along lines of sight in which the molecular hydrogen fraction is expected to be the largest. Using a standard chi square analysis to assess the goodness of fit of our models, we find (at the 60 a level) that a three-dimensional model is more successful in matching the observational data than a one-dimensional model in which the geometrical extent of the cloud along the line of sight is assumed to be much smaller than its extent in the plane of the sky. If D is the distance to G236 + 39, and given standard assumptions about the rate of grain-catalyzed H2 formation, we find that the cloud has an extent along the line of sight that is 0.9 +/- 0.1 times its mean extent projected onto the plane of the sky and a gas density of 53 +/- 8 (100 pc/D) H nuclei/cc and is illuminated by a radiation field of 1.1 +/- 0.2 (100 pc/D) times the mean interstellar radiation field. The derived 100 micron emissivity per nucleon is 1.13 +/- 0.06 x 10(exp -20) MJy/sr sq cm.

Spaans, Marco↗

Shear-Sensitive Liquid Crystal Coating Method Applied Through Transparent Test Surfaces

Research conducted at NASA Ames Research Center has shown that the color-change response of a shear-sensitive liquid crystal coating (SSLCC) to aerodynamic shear depends on both the magnitude of the local shear vector and its direction relative to the observer's in-plane line of sight. In conventional applications, the surface of the SSLCC exposed to aerodynamic shear is illuminated with white light from the normal direction and observed from an oblique above-plane view angle of order 30 deg. In this top-light/top-view mode, shear vectors with components directed away from the observer cause the SSLCC to exhibit color-change responses. At any surface point, the maximum color change (measured from the no-shear red or orange color) always occurs when the local vector is aligned with, and directed away from, the observer. The magnitude of the color change at this vector-observer-aligned orientation scales directly with shear stress magnitude. Conversely, any surface point exposed to a shear vector with a component directed toward the observer exhibits a non-color-change response, always characterized by a rusty-red or brown color, independent of both shear magnitude and direction. These unique, highly directional color-change responses of SSLCCs to aerodynamic shear allow for the full-surface visualization and measurement of continuous shear stress vector distributions. The objective of the present research was to investigate application of the SSLCC method through a transparent test surface. In this new back-light/back-view mode, the exposed surface of the SSLCC would be subjected to aerodynamic shear stress while the contact surface between the SSLCC and the solid, transparent wall would be illuminated and viewed in the same geometrical arrangement as applied in conventional applications. It was unknown at the outset whether or not color-change responses would be observable from the contact surface of the SSLCC, and, if seen, how these color-change responses might relate to those observed in standard practice.

Reda, Daniel C.↗

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗

Beam Shape Effects on Grating Spectrometer Resolution

The collimated optical beam in a grating spectrometer may be circular or elliptical in cross section, so that different parts of the beam illuminate different numbers of grooves on the grating. Here we estimate the consequent loss in spectral resolution relative to that obtained with a beam which illuminates a fixed number of grooves. For representative diffraction resolution functions, the effect is to reduce the intrinsic resolving power of the spectrometer by about 13%, exclusive of other contributions such as finite entrance slit width.

Erickson, Edwin F.↗

BOREAS TE-18 GeoSail Canopy Reflectance Model

The SAIL (Scattering from Arbitrarily Inclined Leaves) model was combined with the Jasinski geo metric model to simulate canopy spectral reflectance and absorption of photosynthetically active radiation for discontinuous canopies. This model is called the GeoSail model. Tree shapes are described by cylinders or cones distributed over a plane. Spectral reflectance and transmittance of trees are calculated from the SAIL model to determine the reflectance of the three components used in the geometric model: illuminated canopy, illuminated background, shadowed canopy, and shadowed background. The model code is Fortran. sample input and output data are provided in ASCII text files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).

Hall, Forrest G.↗

The Shuttle Radar Topography Mission

On February 22, 2000 Space Shuttle Endeavour landed at Kennedy Space Center, completing the highly successful 11-day flight of the Shuttle Radar Topography Mission (SRTM). Onboard were over 300 high-density tapes containing data for the highest resolution, most complete digital topographic map of Earth ever made. SRTM is a cooperative project between NASA and the National Imagery and Mapping Agency (NIMA) of the U.S. Department of Defense. The mission was designed to use a single-pass radar interferometer to produce a digital elevation model (DEM) of the Earth's land surface between about 60 deg north and 56 deg south latitude. When completed, the DEM will have 30 m pixel spacing and about 15 m vertical accuracy. Two orthorectified image mosaics (one from the ascending passes with illumination from the southeast and one from descending passes with illumination from the southwest) will also be produced.

Farr, Tom G.↗

Utilization of Infrared Fiber Optic in the Automotive Industry

Fiber optics are finding a place in the automotive industry. Illumination is the primary application today. Soon, however, fiber optics will be used for data communications and sensing applications. Silica fiber optics and plastic fibers are sufficient for illumination and communication applications however, sensing applications involving high temperature measurement and remote gas analysis would benefit from the use of infrared fiber optics. Chalcogonide and heavy metal fluoride glass optical fibers are two good candidates for these applications. Heavy metal fluoride optical fibers are being investigated by NASA for applications requiring transmission in the infrared portion of the electromagnetic spectrum. Zirconium-Barium-Lanthanum-Aluminum-Sodium-Fluoride (ZBLAN) is one such material which has been investigated. This material has a theoretical attenuation coefficient 100 times lower than that of silica and transmits into the mid-IR. However, the measured attenuation coefficient is higher than silica due to impurities and crystallization. Impurities can be taken care of by utilizing cleaner experimental protocol. It has been found that crystallization can be suppressed by processing in reduced gravity. Fibers processed in reduced gravity on the KC135 reduced gravity aircraft were found to be free of crystals while those processed on the ground were found to have crystals. These results will be presented along with plans for producing continuous lengths of ZBLAN optical fiber on board the International Space Station.

Tucker, Dennis S.↗

Measurement of Separated Flow Structures Using a Multiple-Camera DPIV System

A novel multiple-camera system for the recording of digital particle image velocimetry (DPIV) images acquired in a two-dimensional separating/reattaching flow is described. The measurements were performed in the NASA Langley Subsonic Basic Research Tunnel as part of an overall series of experiments involving the simultaneous acquisition of dynamic surface pressures and off-body velocities. The DPIV system utilized two frequency-doubled Nd:YAG lasers to generate two coplanar, orthogonally polarized light sheets directed upstream along the horizontal centerline of the test model. A recording system containing two pairs of matched high resolution, 8-bit cameras was used to separate and capture images of illuminated tracer particles embedded in the flow field. Background image subtraction was used to reduce undesirable flare light emanating from the surface of the model, and custom pixel alignment algorithms were employed to provide accurate registration among the various cameras. Spatial cross correlation analysis with median filter validation was used to determine the instantaneous velocity structure in the separating/reattaching flow region illuminated by the laser light sheets. In operation the DPIV system exhibited a good ability to resolve large-scale separated flow structures with acceptable accuracy over the extended field of view of the cameras. The recording system design provided enhanced performance versus traditional DPIV systems by allowing a variety of standard and non-standard cameras to be easily incorporated into the system.

Humphreys, William M., Jr.↗

Solar-Reflectance-Based Calibration of Spectral Radiometers

A method by which to calibrate a spectral radiometer using the sun as the illumination source is discussed. Solar-based calibrations eliminate several uncertainties associated with applying a lamp-based calibration to field measurements. The procedure requires only a calibrated reflectance panel, relatively low aerosol optical depth, and measurements of atmospheric transmittance. Further, a solar-reflectance-based calibration (SRBC), by eliminating the need for extraterrestrial irradiance spectra, reduces calibration uncertainty to approximately 2.2% across the solar-reflective spectrum, significantly reducing uncertainty in measurements used to deduce the optical properties of a system illuminated by the sun (e.g., sky radiance). The procedure is very suitable for on-site calibration of long-term field instruments, thereby reducing the logistics and costs associated with transporting a radiometer to a calibration facility.

Cattrall, Christopher↗

Comparison of Light Emitting Diodes (LED) and Fluorescent Light on Suppression of Pineal Melatonin in the Rat

To validate a novel LED array for use in animal habitat lighting by comparing its effectiveness to cool-white fluorescent (CWF) lighting in suppressing pineal gland melatonin. Male Sprague-Dawley rats, 175-200 g, were maintained under control conditions for 2 weeks (food and water ad lib, 12L: 12D CWF, 18 uW/square cm). Dark adapted animals (animals before lights on) were exposed to 5 min of LED or CWF light of similar spectral power distribution. Two groups of rats (LED vs. CWF) were compared at 5 light intensities (100, 40, 1, 1.0, and 0. 1 lux). A control group was placed into the exposure apparatus but not exposed to light. After exposure, pineal glands were rapidly removed and assayed for melatonin by RIA. Results. The dark-exposed control groups matched with the 5 intensity groups (100, 40, 10, 1.0, and 0.1 lux) showed mean + SEM pineal melatonin values of 1167 +/- 136, 1569 +/- 126, 353 +/- 34, 650 +/- 124, and 464 +/- 85, pg/ml respectively. The corresponding CWF exposure data were 393 1 41, 365 +34, 257 +/- 13, 218 +/- 42, and 239 +/- 71 pg/ml, respectively. Corresponding LED exposure data were 439 +/- 25, 462 +/- 50, 231 +/- 6, 164 +/- 12, and 158 +/- 12 pg/ml, respectively. Rats exposed to both experimental light conditions at all illuminances studied showed significant melatonin suppression (p less than 0.01, ANOVA). In no case was the melatonin suppression induced by LED illuminance significantly different from the melatonin suppression elicited by the same intensity of CWF light. The results show that a novel LED light source can suppress pineal melatonin equal to that of a conventional CWF light source.

Winget, Charles M.↗

Frequency Analyzed Laser Light Scattering (Falls)

A simple and robust light scattering technique for spray diagnostics was developed. The technique provides a spray's intact length and breakup frequency. Scattered light is collected from a laser sheet that illuminates a portion of the spray. The scattered light is imaged on a fast photodiode whose output is sampled at 20 kHz. Fast Fourier transform (FFT) analysis is performed on the sampled signal. The shape of the FFT produced can be correlated to one of three distinct spray regimes: intact sheet, ligaments, or droplets. Strobe and laser illuminated photographs are also shown for reference.

Rhys, Noah O.↗

Computer-aided design of a proton pump

The use of transmembrane proton gradients in energy transduction is an almost universal feature of life on earth. These proton gradients are established and maintained by specialized assemblies of proteins which actively pump protons across membranes. One broad class of proton pumps uses captured light energy to drive the proton pumping. Our goal is to elucidate the minimum structural requirements of a light-driven proton-pump. There are two basic components to a simple light-driven proton pump: a source of photo-generated protons and a "gate-keeper" which prevents these protons from reattaching themselves to their source. A wide variety of molecules in the membrane, even as simple as polycyclic aromatic hydrocarbons, are capable of releasing protons when illuminated. Our work is therefore focused on the design of the "gate-keeper." Our initial model involves a pair of proton acceptors, coupled to each other by a transient water bridge, and supported in the membrane by a small bundle of peptide helices. Upon illumination, the proton source transfers its proton to the:- first acceptor of the gate-keeper. While the reverse reaction is highly probable, all that is needed to ensure irreversibility is a nonvanishing probability that the proton will be transferred to the second acceptor across a transient water bridge. Back transfer of the proton to the first acceptor, and thence to the proton source, is impeded by the free energy required to move the proton uphill towards the. proton source and by the disruption of the transient water bridge. As a prototypical water-bridged proton transfer system, we are studying the transfer of a proton across a water bridge from a formic acid to a formate anion. With a pK(sub alpha), of 3.7. formic acid is a good model for the acidic amino acids glutamate and aspartate which are good candidates for gate-keeper proton acceptors. Simulations of proton transfer reactions in a membrane are complicated by the quantum mechanical nature of the process breaking and forming chemical bonds.

New, Michael H.↗

Application of Pressure-Sensitive Paint to Rotorcraft

In this presentation, a plan to develop methods for applying pressure-sensitive paint to rotorcraft will be described. These methods are needed because flows over rotor blades are typically very complex and poorly understood and because conventional methods for measuring unsteady pressures on rotor blades (using unsteady pressure transducers provide grossly inadequate spatial resolution. Since PSP is a surface, rather than a point, measurement technique, it has the potential to significantly increase the spatial resolution )f pressure measurements on rotor blades. PSP techniques currently in use at Ames were developed for measuring steady pressures on rigid, complex airplane configurations in large, production wind tunnels. Applying PSP to rotorcraft requires a significant departure from these techniques. First and most importantly new, fast-responding and self-referencing pressure paints are required. The paints must be fast (98% response in 1-5 msec) to resolve flow unsteadiness; they must be self-referencing (or "binary") to account for changes in incident light intensity due to deflection of flexible rotors. Self-referencing paints have been used at Ames for some time; however, these paints have response times that are far too long for unsteady applications. Flash illumination is required to resolve flow unsteadiness and to minimize image blurring due to relative motion between the model and the camera. Current practice at Ames is to use continuous illumination Finally, "in situ" paint calibration versus measurements by pressure transducers, which is current Ames practice, is not practical because of the difficulty and expense of installing transducers in rotor blades. Instead, the paint must be calibrated "a priori" in a calibration chamber. A sequence of five experiments that systematically isolates and addresses the problems involved in making PSP measurements on rotor blades has been planned. These are: (1) measurements on a rigid rotor in hover; (2) measurements on a flexible rotor in hover; measurements of paint response time in a calibration apparatus; (4) measurements on a rigid, two-dimensional oscillating airfoil; and (5) measurements on a flexible rotor in forward flight. Experiments were recently conducted at Ames where PSP measurements were made on a rigid oscillating airfoil (experiment type 4) and on a flexible rotor in hover (experiment type 2). Preliminary results from these experiments will be discussed.

Schairer, Edward T.↗

Shear-Sensitive Liquid Crystal Coating Method: Surface-Inclination Effects on Shear Vector Measurements

The shear-sensitive liquid crystal coating (SSLCC) method is an image-based technique for both visualizing dynamic surface-flow phenomena, such as transition and separation, and for measuring the continuous shear-stress vector distribution acting on an aerodynamic surface. Under proper lighting and viewing conditions (discussed below), the coating changes color in response to an applied aerodynamic shear. This color-change response is continuous and reversible, with a response time of milliseconds, and is a function of both the shear magnitude and the shear vector orientation relative to the observer. The liquid crystal phase of matter is a weakly-ordered, viscous, non-Newtonian fluid state that exists between the nonuniform liquid phase and the ordered solid phase of certain organic compounds. Cholesteric liquid crystal compounds possess a helical molecular arrangement that selectively scatters white light, incident along the helical axis, as a three-dimensional spectrum. This property is linked to the helical pitch length, which is within the range of wavelengths in the visible spectrum. The pitch length, and hence the wavelength of the scattered light, is influenced by shear stress normal to the helical axis. This unique optical property produces a measurable color change in response to an applied shearing force. The full-surface shear stress vector measurement method, developed at NASA-Ames, is schematically illustrated. As with the visualization method, the coated test surface is illuminated from the normal direction with white light and the camera is positioned at an above-plane view angle of approximately 30 deg. Experiments have been initiated at NASA Ames to begin the process of quantifying surface-inclination (surface-curvature) effects on shear vector measurement accuracy. In preliminary experiments, surface-inclination angles theta(sub x), theta(sub y) of 0, +/-5, +/-10, and +/-15 deg were employed. In this arrangement, white-light illumination was positioned normal to the untilted test surface, and the camera above-plane view angle was set at 30 deg relative to the untilted test surface. As can be seen, vector-aligned lambda(sub d) values showed no dependence on theta(sub x) or theta(sub y) for absolute values of these tilt angles is less than or equal to 15 deg. Acquisition and analyses of full-surface color images are presently underway to definitively document the insensitivity limits of the shear vector measurement methodology to surface-slope variations.

Reda, Daniel C.↗

Night Vision Camera

PixelVision, Inc. developed the Night Video NV652 Back-illuminated CCD Camera, based on the expertise of a former Jet Propulsion Laboratory employee and a former employee of Scientific Imaging Technologies, Inc. The camera operates without an image intensifier, using back-illuminated and thinned CCD technology to achieve extremely low light level imaging performance. The advantages of PixelVision's system over conventional cameras include greater resolution and better target identification under low light conditions, lower cost and a longer lifetime. It is used commercially for research and aviation.

Source record↗