Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION ENGINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A Comparison of Ion Implantation at Room Temperature and Heated Ion Implantation on the Body Diode Degradation of Commercial 3.3 kV 4H-SiC Power MOSFETs

It has been demonstrated that basal plane dislocations (BPDs)-induced stacking faults (SFs) cause body diode degradation in commercial 4H-SiC power MOSFETs, especially with higher voltage ratings. BPDs originate from 4H-SiC boule, epi growth, and ion implantation. Considering the lower cost of ion implantation at room temperature (RT), this work investigates the potential of RT ion implantation replacing heated (HT) ion implantation by comparing the influence of both ion implantations on the body diode degradation of commercial 3.3 kV 4H-SiC power MOSFETs. We demonstrate with long-term (up to 1000 hours) forward current stress that RT implantation can keep the body diode degradation of 3.3 kV 4H-SiC power MOSFETs within the specification limits compared with HT implantation.

4H-SiC↗

Unraveling the conundrum of electronic leakage in protonic ceramic cells: Operation-specific insights and rational design strategies

Electronic conduction through proton-conducting electrolytes significantly impairs the efficiency of protonic ceramic cells (PCCs). Here, in this study, we explore the electron and ion mixed transport properties of four common protonic ceramics, BaZr 0.8 Y 0.2 O 3-δ (BZY82), BaZr 0.7 Ce 0.2 Y 0.1 O 3-δ (BZCY721), BaZr 04 Ce 0.4 Y 0.1 Yb 0.1 O 3-δ (BZCYYb4411), and BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ (BZCYYb1711). It marks the first instance of investigating these properties under operation-specific scenarios: fuel side of electrolysis cell, air side of electrolysis cell, fuel side of fuel cell, and air side of the fuel cell. BZCYYb1711 exhibits the highest ionic conductivity, but two to three times higher electronic leakage when exposed to oxygen-containing environments than the others. BZY82 exhibits approximately two times higher electronic leakage in a hydrogen-containing environment. BZCY721 demonstrates excellent ion transport numbers (~0.95) across these four operating conditions. BZCYYb4411 behaves quite similarly to BZCY721. The most challenging operating environment for all candidates is the air side of fuel cell mode. This mode leads to a high initial electronic leakage, followed by a significant increase with polarization. The probable cause for this behavior is a H 2 -free, polarization-induced reduction that leads to the formation of V$^•_O$. The electron small polaron associated with V$^•_O$ is released by the electrical field due to the Poole-Frenkel effect. ZnO and NiO sintering aids are found to be detrimental to the ionic conductivity of the electrolytes. In particular, NiO substantially lowers the ion transport number. The correlation of the operation-specific electronic leakage to full cells is discussed. It is suggested that a rational PCC design should synergistically couple BZCYYb1711 at fuel side with BZCY4411 at air side to deliver a well-balanced performance and faradaic efficiency simultaneously, and the high temperature sintering process with a NiO fuel electrode should be shortened or replaced by ultra-fast sintering techniques or using a fuel electrode scaffold-infiltration fabrication strategy.

42 ENGINEERING↗

Titanium Optics for Ion Thrusters

Ion thruster total impulse capability is limited, in part, by accelerator grid sputter erosion. A development effort was initiated to identify a material with a lower accelerator grid volumetric sputter erosion rate than molybdenum, but that could utilize the present NSTAR thruster grid design and fabrication techniques to keep development costs low, and perform as well as molybdenum optics. After comparing the sputter erosion rates of several atomic materials to that of molybdenum at accelerator voltages, titanium was found to offer a 45% reduction in volumetric erosion rates. To ensure that screen grid sputter erosion rates are not higher at discharge chamber potentials, titanium and molybdenum sputter erosion rates were measured at these potentials. Preliminary results showed only a slightly higher volumetric erosion rate for titanium, so that screen grid erosion is insignificant. A number of material, thermal, and mechanical properties were also examined to identify any fabrication, launch environment, and thruster operation issues. Several titanium grid sets were successfully fabricated. A titanium grid set was mounted onto an NSTAR 30 cm engineering model ion thruster and tested to determine optics performance. The titanium optics operated successfully over the entire NSTAR power range of 0.5 to 2.3 kW. Differences in impingement-limited perveances and electron backstreaming limits were found to be due to a larger cold gap for the titanium optics. Discharge losses for titanium grids were lower than those for molybdenum, likely due to a slightly larger titanium screen grid open area fraction. Radial distributions of beam current density with titanium optics were very similar to those with molybdenum optics at all power levels. Temporal electron backstreaming limit measurements showed that titanium optics achieved thermal equilibrium faster than molybdenum optics.

Soulas, George C.↗

Conclusions from 3 years of continuous capture plant operation without exchange of the AMP/PZ-based solvent at Niederaussem – insights into solvent degradation management

A many times heard mantra of solvent degradation management in amine-based post combustion capture is “keep the solvent clean” to minimize solvent consumption. It is assumed that the amine losses would decrease by the removal of metals, degradation products, and reactive trace components which are captured from the flue gas, like NO 2 (as potentially driving components of the amine degradation besides dissolved O 2 ). However, this theoretical hypothesis – based on results from laboratory experiments typically generated with fresh amines – disregards the complexity of the solvent matrix, interaction of potential metal catalysts with degradation products and oxidizing agents, and specific chemical requirements which must be fulfilled before a degradation mechanism can proceed. Degradation of the solvent CESAR1 (aqueous solution of 3.0 molar 2-amino-2-methylpropan-1-ol (AMP) and 1.5 molar piperazine (PZ)) is investigated in a unique long-time test campaign (testing time up to now 40 months; 24/7 operation) without replacement of the solvent inventory at the capture pilot plant at the lignite-fired power plant in Niederaussem. Three solvent management strategies with different effect mechanisms are investigated and evaluated: (a) removal of only anionic compounds and trace elements (within 75 days solvent inventory treated two times) and anionic as well as cationic compounds and trace elements (114 days, inventory treated four times) from the solvent by ion exchange, (b) adsorptive removal of trace elements from the solvent by active carbon in 35% of the operating time, and (c) removal of >80% NO 2 by flue gas pretreatment with thiosulfate/sulfite solution (dosing for 2,000 h). The results of the testing program clearly show that “solvent cleanliness” is not a well-defined parameter and that results from laboratory tests, tests without fully representative industrial flue gasses, and short-term testing of monoethanolamine cannot be generalized for other solvents and industrial application. Furthermore, these results showcase that specific degradation management considering solvent, capture plant and flue gas quality is reasonable. Overshooting efforts for solvent management are contra-productive and produce unnecessary waste streams, efficiency losses and costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation response of a Fe–20Cr–25Ni austenitic stainless steel under Fe 2+ irradiation at 500 °C

The radiation response of a Fe–20Cr–25Ni austenitic stainless steel under self-ion irradiation at 500 °C was systematically investigated. The steel was irradiated at 500 °C by 3.5 MeV Fe 2+ ions to 10, 50, and 150 peak dpa, respectively. In the 200–400 nm depth region, radiation-induced Frank loops were relatively stable in both size and number density from 10 to 150 peak dpa. Anisotropic distribution of Frank loops was observed in the 50 and 150 peak dpa specimens, possibly due to interaction of Frank loops and network dislocations with preferred orientations. Coarse voids were found only in the 50 and 150 peak dpa specimens in depths less than 750 nm, suggesting that injected interstitials at deeper regions suppressed the void nucleation. The peak swelling was very low (~0.4%) for both 50 and 150 peak dpa irradiation. Radiation also led to the formation of intragranular plate-like Cr-rich carbides. Radiation-induced segregation of Ni and Si was found at various sinks: dislocation loops, void surfaces, and carbide-matrix interfaces. Finally, irradiation hardening was measured by nanoindentation and the results are consistent with microstructure-based calculations using the dispersed barrier hardening model. The major contributor to irradiation hardening changed from Frank loops at the lowest dose to network dislocations at the highest dose.

dislocation loops↗

Controlling the spacing of the linked graphene oxide system with dithiol linkers under confinement

2D nanoscale confined systems exhibit behavior that is markedly different from that observed at the macroscale. Confinement can be tuned by controlling the interlayer spacing between confining layers using organic dithiol linkers. Adjusting spacing and selective intercalation have important impacts for catalysis, superconductivity, spin engineering, sodium ion batteries, 2D magnets, optoelectronics, and many other applications. In this study, we report how reaction conditions and organic linkers can be used to create variable, reproducible spacings between graphene oxide to provide confinement systems. We determined the conditions under which the spacing can be variably adjusted by the type of linker used, the concentration of the linker, and the reaction conditions. Employing dithiol linkers of different lengths, such as three (TPDT) and four (QPDT) aromatic rings, we can adjust the spacing between graphene oxide layers under varied reaction conditions. Here, we show that by varying dithiol linker length and using different reaction conditions, we can reproducibly control the spacing between graphene oxide layers from 0.37 nm to over 0.50 nm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strain engineering 4H-SiC with ion beams

Single crystals of 4H-SiC irradiated with 900 keV Si and 21 MeV Ni ions separately and sequentially were examined by Rutherford backscattering spectrometry in channeling geometry, single crystal X-ray diffraction, and Raman scattering. SiC irradiated with 900 keV Si ions to a fluence of 6.3 × 10 14 ions/cm 2 experiences 7.3% strain over the depth of 650 nm. Strain relaxation from ionization-induced annealing was directly studied due to subsequent irradiation with 21 MeV Ni ions to a fluence of 2 × 10 14 ions/cm 2 . These competitive processes suggest the use of ion irradiation to create a specific strain state in 4H-SiC, particularly in films.

36 MATERIALS SCIENCE↗

Impact of Surface Recombination on Single-Event Charge Collection in an SOI Technology

Semiconductor–insulator interfaces play an important role in the reliability of integrated devices; however, the impact of these interfaces on the physical mechanisms related to single-event effects has not been previously reported. We present experimental data that demonstrate that single-event charge collection can be impacted by changes in interface quality. The experimental data, combined with simulations, show that single-event response may depend on surface recombination at interface defects. The effect depends on strike location and increases with increasing linear energy transfer (LET). Surface recombination can affect single-event charge collection for interfaces with a surface recombination velocity (SRV) of 1000 cm/s and is a dominant charge collection mechanism with SRV >10 5 cm/s.

42 ENGINEERING↗

SU-F-T-672: A Novel Kernel-Based Dose Engine for KeV Photon Beams

Purpose: Mimicking state-of-the-art patient radiotherapy with high precision irradiators for small animals allows advanced dose-effect studies and radiobiological investigations. One example is the implementation of pre-clinical IMRT-like irradiations, which requires the development of inverse planning for keV photon beams. As a first step, we present a novel kernel-based dose calculation engine for keV x-rays with explicit consideration of energy and material dependencies. Methods: We follow a superposition-convolution approach adapted to keV x-rays, based on previously published work on micro-beam therapy. In small animal radiotherapy, we assume local energy deposition at the photon interaction point, since the electron ranges in tissue are of the same order of magnitude as the voxel size. This allows us to use photon-only kernel sets generated by MC simulations, which are pre-calculated for six energy windows and ten base materials. We validate our stand-alone dose engine against Geant4 MC simulations for various beam configurations in water, slab phantoms with bone and lung inserts, and on a mouse CT with (0.275mm)3 voxels. Results: We observe good agreement for all cases. For field sizes of 1mm{sup 2} to 1cm{sup 2} in water, the depth dose curves agree within 1% (mean), with the largest deviations in the first voxel (4%) and at depths>5cm (<2.5%). The out-of-field doses at 1cm depth agree within 8% (mean) for all but the smallest field size. In slab geometries, the mean agreement was within 3%, with maximum deviations of 8% at water-bone interfaces. The γ-index (1mm/1%) passing rate for a single-field mouse irradiation is 71%. Conclusion: The presented dose engine yields an accurate representation of keV-photon doses suitable for inverse treatment planning for IMRT. It has the potential to become a significantly faster yet sufficiently accurate alternative to full MC simulations. Further investigations will focus on energy sampling as well as calculation times. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR. MFF is supported by Cancer Research UK under Programme C33589/A19908.

43 PARTICLE ACCELERATORS↗