Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Use of radial self-field geometry for intense pulsed ion beam generation above 6 MeV on Hermes III.

We investigate the generation and propagation of intense pulsed ion beams at the 6 MeV level and above using the Hermes III facility at Sandia National Laboratories. While high-power ion beams have previously been produced using Hermes III, we have conducted systematic studies of several ion diode geometries for the purpose of maximizing focused ion energy for a number of applications. A self-field axial-gap diode of the pinch reflex type and operated in positive polarity yielded beam power below predicted levels. This is ascribed both to power flow losses of unknown origin upstream of the diode load in Hermes positive polarity operation, and to anomalies in beam focusing in this configuration. A change to a radial self-field geometry and negative polarity operation resulted in greatly increased beam voltage (> 6 MeV) and estimated ion current. A comprehensive diagnostic set was developed to characterize beam performance, including both time-dependent and time-integrated measurements of local and total beam power. A substantial high-energy ion population was identified propagating in reverse direction, i.e. from the back side of the anode in the electron beam dump. While significant progress was made in increasing beam power, further improvements in assessing the beam focusing envelope will be required before ultimate ion generation efficiency with this geometry can be completely determined.

43 PARTICLE ACCELERATORS↗

Secondary Electron Emission and the Exploration of Space

The emission of secondary electrons from surfaces exposed to the space plasma and radiation environment is a process of great importance to space system engineering design and operations. A spacecraft will collect charge until it reaches an equilibrium potential gov,erned by the balance of incoming electron and ion currents from the space environment with outgoing secondary, backscattered, and photoelectron currents. Laboratory measurements of secondary electron yields are an important parameter for use in spacecraft charging analyses because the magnitude and sign of the equilibrium potential depends on both the energy spectrum of electrons and ions in the space environment and the electrical properties of the surface materials (including the energy dependent secondary electron yields). Typical benign equilibrium potentials range &om a few tens of volts positive in interplanetary space to a few volts negative in low Earth orbit. However, spacecraft are known to charge to negative potentials exceeding one to ten kilovolts in some environments and anomalies or system failures due to electrostatic discharges originating from highly charged surfaces becomes a serious concern. This presentation will provide a review of the spacecraft charging process with special emphasis on the role of secondary electrons in controlling the current balance process. Charging examples will include spacecraft in Earth orbit and interplanetary space as well as dust charging on the lunar surface, a phenomenon of importance to future lunar surface operations.

Minow, Joseph I.↗

Effects of an unbalanced magnetron in a unique dual-cathode, high rate reactive sputtering system

Simple plasma and magnetic field measurements are presented to illustrate the opportunities afforded by using unbalanced magnetrons in a dual-cathode system. The system employs a pair of opposed cathodes, 38 cm x 13 cm, placed 27.5 cm apart, to coat specimens mounted on a rotational substrate holder. Comparisons are drawn between the original 'balanced' magnetron and several unbalanced configurations in terms of field strengths, deposition rates, etching characteristics, and substrate ion current densities for the growth of TiN films. The effects of 'unbalancing' on the nature of the plasma within the 3D geometry of the deposition chamber are elucidated via plasma probe and magnetic field studies performed under a variety of conditions. All the unbalanced configurations examined provided enhanced ion bombardment at the surface of the growing film. The closed-field or opposed magnet geometry resulted in a threefold or greater increase in current density when compared with that obtained using the corresponding mirrored geometry under the same conditions.

Rohde, S. L.↗

Impacts of pellets injected from the low-field side on plasma in ITER

Impacts of pellets injected from the low-field side (LFS) on plasma in ITER are investigated using the 1.5D BALDUR integrated predictive modeling code. In these simulations, the pellet ablation is described using the neutral gas shielding (NGS) model. The pellet ablation model is coupled with the plasma core transport model, which is a combination of the MMM95 anomalous transport model and NCLASS neoclassical transport model. The boundary conditions are assumed to be at the top of the pedestal, in which the pedestal parameters are predicted using a pedestal model based on the theoretical-based pedestal width scaling (either magnetic and flow shear stabilization width scaling, or flow shear stabilization width scaling, or normalized poloidal pressure width scaling) and the infinite-n ballooning mode pressure gradient limit. These pedestal models depend sensitively on the density at the top of the pedestal, which can be strongly influenced by the injection of pellets. The combination of the MMM95 and NCLASS models, together with the pedestal and NGS models, is used to simulate the time evolution of the plasma current, ion and electron temperatures, and density profiles for ITER standard type-I ELMy H-mode discharges during the injection of LFS pellets. It is found that the injection of pellets results in a complicated plasma scenario, especially in the outer region of the plasma and the plasma conditions at the boundary in which the pellet has an impact on increasing the plasma edge density, but reducing the plasma edge temperature. The LFS pellet has a stronger impact on the edge as compared to the center. For fusion performance, the pellet can result in either enhancement or degradation, depending sensitively on the pellet parameters; such as the pellet size, pellet velocity, and pellet frequency. For example, when a series of deuterium pellets with a size of 0.5 cm, velocity of 1 km/s, and frequency of 2 Hz are injected into the ITER plasma from the LFS, the plasma performance, evaluated in terms of Q{sub fusion}, can increase to 72% of that before the use of pellets. It is also found that the injection of pellets results in an increase in the ion and electron densities, but does not enhance the central plasma density. On the other hand, it results in the formation of another peak of the plasma density in the outer region near the plasma edge. The formation of the density peak results in the reduction of plasma transports near the edge by decreasing the contributions of ion-temperature-gradient and trapped electron modes, as well as kinetic ballooning modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High current multicharged metal ion source using high power gyrotron heating of vacuum arc plasma

A high current, multi charged, metal ion source using electron heating of vacuum arc plasma by high power gyrotron radiation has been developed. The plasma is confined in a simple mirror trap with peak magnetic field in the plug up to 2.5 T, mirror ratio of 3-5, and length variable from 15 to 20 cm. Plasma formed by a cathodic vacuum arc is injected into the trap either (i) axially using a compact vacuum arc plasma gun located on axis outside the mirror trap region or (ii) radially using four plasma guns surrounding the trap at midplane. Microwave heating of the mirror-confined, vacuum arc plasma is accomplished by gyrotron microwave radiation of frequency 75 GHz, power up to 200 kW, and pulse duration up to 150 {mu}s, leading to additional stripping of metal ions by electron impact. Pulsed beams of platinum ions with charge state up to 10+, a mean charge state over 6+, and total (all charge states) beam current of a few hundred milliamperes have been formed.

43 PARTICLE ACCELERATORS↗

The inconsistency between proton charge exchange and the observed ring current decay

The equatorial pitch-angle distributions of ring-current ions observed during a storm recovery phase at L values between 3 and 4 are compared with the pitch-angle distributions predicted by proton charge exchange with neutral hydrogen. Large disagreements are found, and three alternative explanations are explored. (1) A strong proton source acts to mask the effects of charge exchange. It is believed that the required strong continual source with a unique pitch-angle and energy dependence is unrealistic at these low L values. (2) Presently accepted neutral hydrogen density models have densities well over an order of magnitude too large for a storm recovery phase. No evidence is known to support the required large errors in the densities. (3) The ring current at particle energies not exceeding 50 keV was dominated by some ion species other than protons during the storm recovery phase. Such ions must have much longer lifetimes for charge exchange with hydrogen than do protons. This alternative is strongly favored, with He(+) being an attractive candidate.

Lyons, L. R.↗

Temperature-Driven Structural Phase Transition for Trapped Ions and a Proposal for its Experimental Detection

A Wigner crystal formed with trapped ions can undergo a structural phase transition, which is determined only by the mechanical conditions on a classical level. Instead of this classical result, we show that through consideration of quantum and thermal fluctuation, a structural phase transition can be driven solely by a change in the system's temperature. We determine a finite-temperature phase diagram for trapped ions using the renormalization group method and the path integral formalism, and propose an experimental scheme to observe the predicted temperature-driven structural phase transition, which is well within the reach of the current ion trap technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technical Note: An investigation of polarity effects for wide-angle free-air chambers

Purpose: Wide-angle free-air chambers (WAFACs) are used as primary standard measurement devices for establishing the air-kerma strength of low-energy, low-dose rate brachytherapy seeds. The National Research Council of Canada (NRC) is commissioning a primary standard wide-angle free-air chamber (NRC WAFAC) to serve the calibration needs of Canadian clients. The University of Wisconsin has developed a similar variable-aperture free-air chamber (UW VAFAC) to be used as a research tool. As part of the NRC commissioning, measurements were carried out for both polarities of the applied bias voltage and the resulting effects were observed to be very large. Similar effects were identified with the UW VAFAC. The authors describe the measurements carried out to determine the underlying causes of the polarity effect and the approach used to eliminate it. Methods: The NRC WAFAC is based on the WAFAC design developed at the National Institute of Standards and Technology in the USA. Charge measurements for {sup 125}I and {sup 241}Am sources were carried out for both negative and positive polarities on the NRC WAFAC and UW VAFAC. Two aperture sizes were also investigated with the UW VAFAC. In addition, measurements on the NRC WAFAC were carried out with a small bias between the collecting electrode and the shield foil at the downstream end of the chamber. To mitigate all of the polarity effects, the downstream surface of the collecting electrode was covered with a thin layer of graphite on both the NRC and UW chambers. Results: Both chamber designs showed a difference of more than 30 % between the charge collected with positive and negative bias voltages for the smallest electrode separation. It was shown for the NRC WAFAC that charge could be collected in the small gap downstream of the collecting volume by applying a voltage between the shield foil and the collecting electrode, even though an insulating foil (Mylar or polyimide film) separated the conducting surface from the small gap region. The unwanted additional current was shown to be proportional to the size of the aperture for the UW VAFAC. The extra ionization produced in the small gap region was eliminated for both chambers by covering the insulating side of the collecting electrode with a grounded conducting layer. Conclusions: The small gap region downstream of the collecting electrode in the NRC WAFAC and UW VAFAC can serve as an unwanted source of ion current. It is concluded that a residual electric field in the small gap region may lead to ion transport and to charge being trapped on the surface of the foil. The foil then acts as a capacitor with an equal charge, but of opposite sign, being attracted to the conducting surface. Covering the back of the collecting electrode surface with a grounded conducting layer eliminated the polarity effect.

61 RADIATION PROTECTION AND DOSIMETRY↗

A proposal for a novel H ion source based on electron cyclotron resonance heating and surface ionization

A design for a novel H{sup -} ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE{sub 111} eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H{sup -} ion beam is further 'self-extracted' through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H{sup -} ion current, beam emittance and duty factor of the novel source are estimated.

43 PARTICLE ACCELERATORS↗

Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source

A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.

43 PARTICLE ACCELERATORS↗

Power flow in magnetically insulated transmission lines with ion backscatter effects

Ion backscattering off of surfaces in magnetically insulated transmission lines (MITLs) is often ignored in kinetic simulations of MITL power flow. Backscattering reduces ion current losses and the surface impact heating, which dictates the rate at which surface-adsorbed contaminants are liberated into the anode–cathode gap. Backscatter probabilities are difficult to implement in a kinetic code because there are limited data for incident ion energies less than a few keV. This paper presents an analytic model based on the Rutherford scattering formula that reproduces the measured backscatter probabilities at high incident energies and transitions to the highly reflective behavior expected at low incident energies. The backscatter model is implemented in power flow simulations, which are validated with current loss experiments conducted on the 0.4 TW Mykonos accelerator at Sandia National Laboratories. This simulation setup is then used in a high-current Z-machine shot. In conclusion, backscatter effects are found to be unimportant in the low-current Mykonos regime but significantly reduce current losses at the Z-machine scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The 15 cm mercury ion thruster research 1975

Doubly charged ion current measurements in the beam of a SERT II thruster are shown to introduce corrections which bring its calculated thrust into close agreement with that measured during flight testing. A theoretical model of doubly charged ion production and loss in mercury electron bombardment thrusters is discussed and is shown to yield doubly-to-singly charged ion density ratios that agree with experimental measurements obtained on a 15 cm diameter thruster over a range of operating conditions. Single cusp magnetic field thruster operation is discussed and measured ion beam profiles, performance data, doubly charged ion densities, and discharge plasma characteristics are presented for a range of operating conditions and thruster geometries. Variations in the characteristics of this thruster are compared to those observed in the divergent field thruster and the cusped field thruster is shown to yield flatter ion beam profiles at about the same discharge power and propellant utilization operating point. An ion optics test program is described and the measured effects of grid system dimensions on ion beamlet half angle and diameter are examined. The effectiveness of hollow cathode startup using a thermionically emitting filament within the cathode is examined over a range of mercury flow rates and compared to results obtained with a high voltage tickler startup technique. Results of cathode plasma property measurement tests conducted within the cathode are presented.

Wilbur, P. J.↗

Dependence of the charge exchange lifetimes on mirror latitude

The dependence of the charge exchange lifetimes on the mirror latitude for ions mirroring off the geomagnetic equator was re-computed using the improved hydrogen distribution models. The Chamberlain model was used to define the spatial distribution of the neutral hydrogen environment through which the ring current ions traverse. The resultant dependence of the charge exchange lifetime on mirror latitude is best fitted by the approximation that contains the charge exchange lifetime for equatorial particles.

Smith, P. H.↗

A Seemingly Simple Task: Filling a Solenoid Volume in Vacuum with Dense Plasma

Space-charge neutralization of a pulsed, high-current ion beam is required to compress and focus the beam on a target for warm dense matter physics or heavy ion fusion experiments. We described attempts to produce dense plasma in and near the final focusing solenoid through which the ion beam travels, thereby providing an opportunity for the beam to acquire the necessary charge-compensating electrons. Among the options are plasma injection from four pulsed vacuum arc sources located outside the solenoid, and using a high current (> 4 kA) pulsed vacuum arc plasma from a ring cathode near the edge of the solenoid. The plasma distribution is characterized by photographic means and by an array of movable Langmuir probes. The plasma is produced at several cathode spots distributed azimuthally on the ring cathode. Beam neutralization and compression are accomplished, though issues of density, uniformity, and pulse-to-pulse reproducibly remain to be solved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dielectric magnifying of plasma blocks by nonlinear force acceleration with delayed electron heating

Specific studies were performed in order to increase the thickness of laser generated directed space charge quasineutral plasma blocks with anomalously high ion current densities above 10{sup 11} A/cm{sup 2}. This may lead to an alternative scheme of laser driven fusion with the irradiation of petawatt-picosecond laser pulses. Initial electron densities were used with Rayleigh profiles, because these are unique for inhomogeneous plasmas for undistorted acceleration at very low reflectivity until thermal absorption processes disturb these ideal conditions. Numerical hydrodynamic results based on a genuine two-fluid code are presented to optimize the block generation for possible fast ignition and details show the delay of thermal exchange between the ion and electron plasma fluid.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma instability in the afterglow of electron cyclotron resonance discharge sustained in a mirror trap

The work presented in this article is devoted to time-resolved diagnostics of non-linear effects observed during the afterglow plasma decay of a 14 GHz electron cyclotron resonance ion source operated in pulsed mode. Plasma instabilities that cause perturbations of the extracted ion current during the decay were observed and studied. It is shown that these perturbations are associated with precipitation of high energy electrons along the magnetic field lines and strong bursts of bremsstrahlung emission. The effect of ion source settings on the onset of the observed instabilities was investigated. Based on the experimental data and estimated plasma properties, it is assumed that the instabilities are of cyclotron type. The conclusion is supported by a comparison to other types of plasma devices which exhibit similar characteristics but which operate in a different plasma confinement regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comparison of Electric Propulsion Systems for Mars Exploration

Earth-Mars trajectories for multiple solar-powered spacecraft configurations were generated using Hall and ion propulsion systems utilizing the Direct Trajectory Optimization Method. Payload and power trades versus trip time were examined. Performance was compared for purely interplanetary flight and interplanetary flight with estimated spiral in to Mars orbit. Evaluating current ion and Hall thruster technologies, similar payload masses were delivered by each at equivalent trip times, but with the Hall thruster operating at a power level 10 kilowatts, on average, less than the ion thruster. The power difference for equivalent payload delivered should result in a significant cost savings.

Fiehler, Douglas↗

Time evolution of bremsstrahlung and ion production of an electron cyclotron resonance ion source

Bremsstrahlung radiation measurement is one of the most commonly used plasma diagnostics methods. Most of the bremsstrahlung measurements with electron cyclotron resonance (ECR) ion sources have been performed in continuous operation mode yielding information only on the steady state bremsstrahlung emission. This article describes the results of bremsstrahlung and ion current measurement with the JYFL 14 GHz ECRIS operated in pulsed mode. The experiments reveal information about the bremsstrahlung radiation in plasma conditions before reaching the equilibrium. The time scale of bremsstrahlung production is compared to ion production time scale for different charge states. The bremsstrahlung data is presented with 2 millisecond time intervals as a function of neutral gas pressure and microwave power. Data from hundreds of microwave pulses is combined in order to have a sufficient amount of events at each time step. The relevant plasma physics phenomena during both, the leading and the trailing edge of the RF pulse, are discussed.

43 PARTICLE ACCELERATORS↗