Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Differently Structured Fabry-Perot Interferometers for Gas Pressure Monitoring

In this study, we present an experimental comparison of gas pressure sensors based on differently structured extrinsic Fabry-Pérot interferometers (FPIs). Different fabrication techniques were adopted to foster the practical realization of these sensors. A novel photonic crystal fiber (PCF) based FPI with an angle cleaved end face that enables gas to easily flow in and out of the cavity while also avoiding the mixed signal from the cascaded structure is also presented. We measured helium gas pressure from 0.1 MPa (atmospheric pressure) to 5 MPa at room temperature and obtained a gas pressure sensitivity coefficient of 0.5±0.01 nm/MPa. Furthermore, the gas pressure sensitivities are numerically analyzed to validate the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of the Equilibrium Evolution of the ZaP Flow $Z$ -Pinch Using a Four-Chord Interferometer

For this study, a four-chord interferometer and measurements from an array of surface-mounted magnetic probes were used in conjunction with equations of radial heat conduction and radial force balance to calculate the equilibrium evolution of a pinch plasma in the ZaP Flow Z-Pinch. A multiple shooting method was used to solve the nonlinear coupled differential equation system, with Ohmic heating and bremsstrahlung radiation as sources and sinks, respectively. Data from a single ZaP pulse are reported including profiles of magnetic field and temperature and their evolution. Profiles are dominated by high thermal conductivity near the axis which quickly decreases with radius. This is due to the plasma being weakly magnetized near the axis which increases thermal conductivity and flattens the temperature profile, but strongly magnetized near the characteristic radius, significantly reducing thermal conductivity and resulting in a large temperature gradient. The equilibrium evolution indicates that plasmas in ZaP heat and compress with increasing current as a result of magnetic compression during the quiescent period.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗

Progress in the Construction and Testing of the Tianlai Radio Interferometers

The Tianlai Pathfinder is designed to demonstrate the feasibility of using a wide field of view radio interferometers to map the density of neutral hydrogen in the Universe after the Epoch of Reionizaton. This approach, called 21~cm intensity-mapping, promises an inexpensive means for surveying the large-scale structure of the cosmos. The Tianlai Pathfinder presently consists of an array of three, 15~m $\times$ 40~m cylinder telescopes and an array of sixteen, 6~m diameter dish antennas located in a radio-quiet part of western China. The two types of arrays were chosen to determine the advantages and disadvantages of each approach. The primary goal of the Pathfinder is to make 3D maps by surveying neutral hydrogen over large areas of the sky %$20,000 {\rm deg}^2$ in two different redshift ranges: first at $1.03 > z > 0.78$ ($700 - 800$~MHz) and later at $0.21 > z > 0.12$ ($1170 - 1270$~MHz). The most significant challenge to $21$~cm intensity-mapping is the removal of strong foreground radiation that dwarfs the cosmological signal. It requires exquisite knowledge of the instrumental response, i.e. calibration. In this paper, we provide an overview of the status of the Pathfinder and discuss the details of some of the analysis that we have carried out to measure the beam function of both arrays. We compare electromagnetic simulations of the arrays to measurements, discuss measurements of the gain and phase stability of the instrument, and provide a brief overview of the data processing pipeline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Binary pseudo-random array for calibration of interferometers with transmission spheres and cylinders

Binary pseudo-random array (BPRA) “white noise” artifacts are highly effective for characterizing the instrument transfer function (ITF) of surface topography metrology tools and wavefront measurement instruments. These BPRA artifacts feature all spatial frequencies within the instrument bandpass equally, resulting in a power spectral density with a white-noise-like character. This characteristic allows for direct ITF determination with uniform sensitivity across the entire spatial frequency range. We have developed a novel BPRA calibration standard that combines the diffractive pattern of a reflection computer-generated hologram (CGH) with the white noise generating BPRA pattern. By integrating these technologies using the same lithographic techniques, the resulting calibration sample enables ITF characterization of a Fizeau interferometer with a transmission sphere, or any nulling optic.

Munechika, K↗

The Effects of the Local Environment on a Compact Radio Interferometer I: Cross-Coupling in the Tianlai Dish Pathfinder Array

The visibilities measured by radio astronomical interferometers include non-astronomical correlated signals that arise from the local environment of the array. These correlated signals are especially important in compact arrays such as those under development for 21cm intensity mapping. The amplitudes of the contaminated visibilities can exceed the expected 21cm signal and represent a significant systematic effect. We study the receiver noise radiated by antennas in compact arrays and develop a model for how it couples to other antennas. We apply the model to the Tianlai Dish Pathfinder Array (TDPA), a compact array of 16, 6-m dish antennas. The coupling model includes electromagnetic simulations, measurements with a network analyzer, and measurements of the noise of the receivers. We compare the model to drift-scan observations with the array and set requirements on the level of antenna cross-coupling for 21cm intensity mapping instruments. Here, we find that for the TDPA, cross-coupling would have to be reduced by three orders of magnitude in order to contribute negligibly to the visibilities.

21cm intensity mapping↗

Quantifying the Accuracy and Uncertainty of Diurnal Thermodynamic Profiles and Convection Indices Derived from the Atmospheric Emitted Radiance Interferometer

Abstract While radiosondes have provided atmospheric scientists an accurate high-vertical-resolution profile of the troposphere for decades, they are unable to provide high-temporal-resolution observations without significant recurring expenses. Remote sensing technology, however, has the ability to monitor the evolution of the atmosphere in unprecedented detail. One particularly promising tool is the Atmospheric Emitted Radiance Interferometer (AERI), a passive ground-based infrared radiometer. Through a physical retrieval, the AERI can retrieve the vertical profile of temperature and humidity at a temporal resolution on the order of minutes. The synthesis of these two instruments may provide an improved diagnosis of the processes occurring in the atmosphere. This study provides a better understanding of the capabilities of the AERI in environments supportive of deep, moist convection. Using 3-hourly radiosonde launches and thermodynamic profiles retrieved from collocated AERIs, this study evaluates the accuracy of AERI-derived profiles over the diurnal cycle by analyzing AERI profiles in both the convective and stable boundary layers. Monte Carlo sampling is used to calculate the distribution of convection indices and compare the impact of measurement errors from each instrument platform on indices. This study indicates that the nonintegrated indices (e.g., lifted index) derived from AERI retrievals are more accurate than integrated indices (e.g., CAPE). While the AERI retrieval’s vertical resolution can inhibit precise diagnoses of capping inversions, the high-temporal-resolution nature of the AERI profiles overall helps in detecting rapid temporal changes in stability.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a land-atmosphere coupling metric computed from a ground-based infrared interferometer

Land-atmosphere feedbacks are a critical component of the hydrologic cycle. Vertical profiles of boundary layer temperature and moisture, together with information about the land surface, are used to compute land-atmosphere coupling metrics. Ground based remote sensing platforms, such as the Atmospheric Emitted Radiance Interferometer (AERI), can provide high temporal resolution vertical profiles of temperature and moisture. When co-located with soil moisture, surface flux, and surface meteorological observations, such as at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site, it is possible to observe both the terrestrial and atmospheric legs of land-atmosphere feedbacks. In this study, we compare a commonly used coupling metric computed from radiosonde-based data to that obtained from the AERI to characterize the accuracy and uncertainty in the metric derived from the two distinct platforms. This approach demonstrates the AERI’s utility where radiosonde observations are absent in time and/or space. Radiosonde and AERI based observations of the Convective Triggering Potential and Low-Level Humidity Index (CTP-HI low ) were computed during the 1200 UTC observation time and displayed good agreement during both 2017 and 2019 warm seasons. Furthermore, radiosonde and AERI derived metrics diagnosed the same atmospheric preconditioning based upon the CTP-HI low framework a majority of the time. When retrieval uncertainty was considered, even greater agreement was found between radiosonde and AERI derived classification. The AERI’s ability to represent this coupling metric well enabled novel exploration of temporal variability within the overnight period in CTP and HI low . Observations of CTP-HI low computed within a few hours of 1200 UTC were essentially equivalent, however with greater differences in time arose greater differences in CTP and HI low .

54 ENVIRONMENTAL SCIENCES↗

Preliminary Neutronics Analysis of the ITER Toroidal Interferometer and Polarimeter Diagnostic Corner Cube Retroreflectors

ITER is an international project under construction in France that will demonstrate nuclear fusion at a power plant-relevant scale. The Toroidal Interferometer and Polarimeter (TIP) Diagnostic will be used to measure the plasma electron line density along 5 laser-beam chords. This line-averaged density measurement will be input to the ITER feedback-control system. The TIP is considered the primary diagnostic for these measurements, which are needed for basic ITER machine control. Therefore, system reliability & accuracy is a critical element in TIP’s design. There are two major challenges to the reliability of the TIP system. First is the survivability and performance of in-vessel optics and second is maintaining optical alignment over long optical paths and large vessel movements. Both of these issues greatly depend on minimizing the overall distortion due to neutron & gamma heating of the Corner Cube Retroreflectors (CCRs). These are small optical mirrors embedded in five first wall locations around the vacuum vessel, corresponding to certain plasma tangency radii. During the development of the design and location of these CCRs, several iterations of neutronics analyses were performed to determine and minimize the total distortion due to nuclear heating of the CCRs. The CCR corresponding to TIP Channel 2 was chosen for analysis as a good middle-road case, being an average distance from the plasma (of the five channels) and having moderate neutron shielding from its blanket shield housing. Results show that Channel 2 meets the requirements of the TIP Diagnostic, but barely. These results suggest other CCRs might be at risk of exceeding thermal deformation due to nuclear heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed phase sensing using two-mode squeezed states in a truncated SU(1,1) interferometer

We demonstrate distributed phase sensing with a truncated SU(1,1) interferometer through the measurement of a linear combination of two phases distributed between the two beams of a two-mode squeezed state. We theoretically analyze the sensitivity enhancement with respect to the corresponding classical strategy and experimentally demonstrate a 2 dB quantum noise reduction in the measurement of a linear combination of two phases.

Hong, Seongjin↗

A Broadband All-Fiber SU(1,1) Interferometer

We describe an SU(1,1) interferometer based on highly nonlinear optical fiber, attaining >97% peak interference visibility and >90% visibility over a 554 GHz optical band.

Lukens, Joseph↗

Continuously active interferometer stabilization and control for time-bin entanglement distribution

In this study, we describe a new method enabling continuous stabilization and fine-level phase control of time-bin entanglement interferometers. Using this technique we demonstrate entangled photon transmission through 50 km of standard single-mode fiber. This technique reuses the entangled-pair generation pump which is co-propagated with the transmitted entangled photons. In addition, the co-propagating pump adds minimal noise to the entangled photons which are characterized by measuring a two-photon interference fringe.

74 ATOMIC AND MOLECULAR PHYSICS↗

On-fiber plasmonic interferometer for multi-parameter sensing

We demonstrate a novel miniature multi-parameter sensing device based on a plasmonic interferometer fabricated on a fiber facet in the optical communication wavelength range. This device enables the coupling between surface plasmon resonance and plasmonic interference in the structure, which are the two essential mechanisms for multi-parameter sensing. We experimentally show that these two mechanisms have distinctive responses to temperature and refractive index, rendering the device the capability of simultaneous temperature and refractive index measurement on an ultra-miniature form factor. A high refractive index sensitivity of 220 nm per refractive index unit (RIU) and a high temperature sensitivity of –60 pm/ °C is achieved with our device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Holography with a neutron interferometer

We use a Mach-Zehnder interferometer to perform neutron holography of a spiral phase plate. The object beam passes through a spiral phase plate, acquiring the phase twist characteristic of orbital angular momentum states. The reference beam passes through a fused silica prism, acquiring a linear phase gradient. The resulting hologram is a fork dislocation image, which could be used to reconstruct neutron beams with various orbital angular momenta. This work paves the way for novel applications of neutron holography, diffraction and imaging.

47 OTHER INSTRUMENTATION↗

Single-mode porous silicon waveguide interferometers with unity confinement factors for ultra-sensitive surface adlayer sensing

Guided wave-optics has emerged as a promising platform for label free biosensing. However, device sensitivity toward surface-bound small molecules is directly limited by the evanescent interaction and low confinement factor with the active sensing region. Here, we report a mesoporous silicon waveguide design and inverse fabrication technique that resolves the evanescent field interaction limitation while achieving maximal transverse confinement factors and preserving single-mode operation. The waveguide sensors are characterized in a Fabry-Perot interferometer configuration and the ultra-high sensitivity to small molecule adlayers is demonstrated. We also identify dispersion to be a promising degree of freedom for exceeding the sensitivity limits predicted by the conventional non-dispersive effective medium theory.

47 OTHER INSTRUMENTATION↗

Self referencing attosecond interferometer with zeptosecond precision

In this work we demonstrate the generation of two intense, ultrafast laser pulses that allow a controlled interferometric measurement of higher harmonic generation pulses with 12.8 attoseconds in resolution (half the atomic unit of time) and a precision as low as 680 zeptoseconds (10–21 seconds). We create two replicas of a driving femtosecond pulse which share the same optical path except at the focus where they converge to two foci. An attosecond pulse train emerges from each focus through the process of high harmonic generation. The two attosecond pulse trains from each focus interfere in the far field producing a clear interference pattern in the extreme ultraviolet region. By controlling the relative optical phase (carrier envelope phase for pulsed fields) between the two driving laser pulses we are able to actively influence the delay between the pulses and are able to perform very stable and precise pump-probe experiments. Because of the phase shaping operation occurs homogeneously across the entire spatial profile, we effectively create two indistinguishable intense laser pulses or a common path interferometer for attosecond pulses. Commonality across the two beams means that they are extremely stable to environmental and mechanical fluctuations up to a Rayleigh range from the focus. In our opinion this represents an ideal source for homodyne and heterodyne spectroscopic measurements with sub-attosecond precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗