Facile one-pot synthesis of γ-Fe 2 O 3 nanoparticles by inductive heating
The direct one-pot synthesis of γ-Fe 2 O 3 nanoparticles (NPs) has been demonstrated through a facile inductive heating method.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The direct one-pot synthesis of γ-Fe 2 O 3 nanoparticles (NPs) has been demonstrated through a facile inductive heating method.
Renewable feedstocks, such as lignocelulosic fast pyrolysis oils and both vegetable oil and animal fats, are becoming a viable alternative to petroleum for producing high-quality renewable transportation fuels. However, the presence of phosphorus-containing compounds, mainly from phospholipids, in these renewable feedstocks is known to poison and deactivate hydrotreating catalysts during fuel production. In this work, gel permeation chromatography (GPC) combined with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was used to analyze feedstocks including unprocessed soybean oil, animal fat, and pyrolysis oils from red oak and milorganite to identify phosphorus species. The results have shown the presence of a wide range of different phosphorous compounds among all the samples analysed in this work. The GPC-ICP-HRMS analyses of a vegetable oil and two animal fats have shown different fingerprints based on the molecular weight of each of the samples, highlighting the structural differences among their corresponding phosphorus-containing compounds. While the presence of low-molecular-weight species, such as phospholipids, was expected, several high-molecular-weight species (MW > 10 000 Da) have been found, suggesting that high-molecular-weight micelles or liposomes might have been formed due to the high concentration of phospholipids in these samples. Results obtained through the hydroxylation of a mix of phospholipids (asolectin) and its posterior GPC-ICP-HRMS agree with this hypothesis. With respect to the lignocellulosic catalytic fast pyrolysis oil samples, the GPC-ICP-HRMS results obtained suggest that either aggregation or polymerization reactions might have occurred during the pyrolysis process, yielding phosphorus-containing compounds with an approximate molecular weight above 91 000 kDa. In addition, an aggregation phenomenom has been observed for those phosphorus species present within the fast pyrolysis oils after being stored for 3 months, especially for those pyrolysis oils contaning pre-processed feedstocks, such as milorganite.
Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.
Inductively coupled plasma-optical emission spectra were modeled with partial least squares regression models to quantify trace elements in uranium (20–5000 μg per g U) without chemical separations or matrix matched calibration standards.
Interference removal in inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is strongly dependent on the gas selected for use within the collision/reaction cell. There has been little investigation on the effects that reaction gas impurities may have on the resulting spectra. The reactivity of 60 elements was evaluated using nitric oxide (NO 99.5%) with and without a gas purifier to reduce H 2 O impurities to <100 pptV. Experiments were performed using V, Ce, Tl and Th to investigate the effects of purified NO at various flowrates (0.22–1.49 mL min -1 ). Purified NO was shown to significantly mitigate oxy-hydride interferences, improve total ion sensitivity (notable at high gas flows), and shift product distributions advantageously. The reduction in oxy-hydride species results in a product distribution favoring the major expected products, where signals were shown to increase by an order of magnitude. Reduced background and increased signal for the major expected products provides avenues for improving various analytical applications of ICP-MS/MS.
This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.
A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.
The actinides present a unique challenge to chemical theory. The classical view of covalent bonding is driven by the extent of spatial overlap of valence orbitals. Modern theory has expanded assessments of covalency to include considerations of orbital energy degeneracy to assess orbital energy mixing between metal and ligand valence orbitals. Actinide–ligand (An–L) bonding has more recently been described as a balance between orbital overlap and orbital energy mixing, where 5f and L valence orbital overlap decreases while energy mixing between An 5f and L valence orbitals increases across the series. To test these existing views, we employed inductively coupled plasma tandem mass spectrometry to examine the kinetic energy dependences of reactions of actinide cations, Th + –Am + , with methane. Further, this is the first experimental report of the energy dependences of methane activation reactions involving the cations of Pa, Np, Pu, and Am and the first experimental determination of transuranic An + –D, An + –CD 2 , An + –CD 3 , and An + –CD bond dissociation energies. The correlation of the measured An + –CD 2 bond energies with E p (6d 2 ) indicates that An + 6d orbitals are the dominant contributors in the An + –CD 2 bonds. Close examination of the relative reactivities of An + offers additional support that the balance of classical and modern views of molecular bonding may lie between Np + and Pu + and that the increased reactivity of Th + –Np + may be attributed to the increased spatial extension of the 5f orbitals whereas covalent An + bond formation may be more driven by the decreasing energies of the 5f orbitals across the actinide series.
The bonding mechanisms of actinides have been a focus of fundamental research over the past few decades. In the present study, reactions of the simplest actinide-containing species, ThH + and UH + , with O 2 and CO 2 are investigated by inductively coupled plasma tandem mass spectrometry. The reactions of ThH + and UH + with O 2 are efficient, and the reactions of ThH + and UH + with CO 2 display reduced reaction efficiencies. For both reactions involving CO 2 , ThO 2 + and UO 2 + are observed; however, there is a clear barrier to ThO 2 + formation whereas UO 2 + forms through an exothermic, barrierless process. The experimental observations and available thermodynamic information are used to predict the outcomes of reactions involving the later AnH + . The anticipated reaction enthalpies for Pa–Am display a clear correlation with the promotion energy of An + to a 6d 2 electronic configuration, E p (6d 2 ), although a shift in the slope of the correlation of reaction enthalpies and E p (6d 2 ) suggests that there is likely a change in bonding mechanism that starts with Np + . Similar shifts have also been noted in previous studies. Beginning with Np + , the 6d orbitals become less accessible than they are for the earlier An + as measured by E p (6d 2 ), and this accessibility of the 6d orbitals may drive actinide bonding.
Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.
The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. The study installed electric induction stoves and repeated measurements over three 2-week intensive periods, at baseline and at the end of two consecutive 3-month study phases. Stove replacements occurred at the start of Phase 1 or Phase 2 by random assignment. There were 4184 cooking events identified by automated analysis of time-series data from temperature sensors mounted above the cooktops and 1038 related range hood usage events detected from data recorded by anemometers, smart plugs, or motor loggers. Analysis of 1-minute resolved PM2.5 and NO 2 data identified and quantified 2685 PM 2.5 events and 2606 NO 2 events. Range hood use was characterized as a binary variable (>3 min vs. <3 min use). Range hood use was more common during cooking events associated with particle emissions and longer cooking durations. PM 2.5 concentrations during events with range hood use were comparable to those without use, which could result from limited effectiveness or if range hoods were preferentially used during higher-emission cooking scenarios. In homes with gas cooking, integrated NO 2 concentrations were about 45 percent higher during cooking events with no range hood use compared to those range hood use. The lowest pollutant levels were observed when the range hood operated for more than half of the cooking duration. These findings show that operation of venting range hood during cooking can substantially reduce short-term indoor exposure NO 2 in homes with gas cooking.
This study examined the optimal conditions of neutral beam generation to maintain a high degree of neutralization and focusing during beam energy variation for a neutral beam source based on inductively coupled plasma with a three-grid ion beam acceleration system. The neutral beam energy distribution was estimated by measuring the energy profiles of ions that 'survived' the neutralization after reflection. The energy measurements of the primary and reflected ions showed narrow distribution functions, each with only one peak. At higher beam energies, both the ratio of the ion energy loss to the primary energy and the degree of energy divergence decreased, confirming the precise alignment of the neutral beam. The neutralization efficiency of the neutral beam source with a three-grid acceleration system was found to be affected mainly by the beam angle divergence rather than by the particle translation energy.
Non-inductive tokamak discharges with a flat or hollow current profile are prone to the triggering of large tearing modes when the minimum of the safety factor is just below a low order rational. This issue is of particular importance for discussing the optimal safety factor for MHD modes avoidance in Steady-State reactor plasmas. Different non-linear regimes of such magnetic configurations in Tore Supra are studied using the full MHD code XTOR. Numerical simulations show that the non-linear stage of the Double-Tearing Mode (DTM) is governed by the full reconnection model, but a single tearing mode in a low magnetic shear configuration can have a similar impact on the confinement. The different regimes observed experimentally are recovered in the simulations: a small amplitude (2,1) DTM for close resonant surfaces as seen in Tore Supra, a sawtooth-like behaviour of the (2,1) Double-Tearing Mode as first seen in TFTR, or a large amplitude (2,1) tearing mode that severely degrades the energy confinement, as reported in Tore Supra, JET or DIII-D. Situations where q{sub min}{approx_equal}1.5 with a stable n = 1 mode, as seen in Tore Supra longest discharges, seem to put specific constraints on the MHD model that is used. Indeed, curvature stabilisation without transport terms as could explain linear stability, but such effect vanishes in presence of heat transport. Electron diamagnetic rotation effect is investigated as a possible mechanism for n = 1 mode stabilization.
We investigated the evolution of the electron energy distribution function (EEDF) in a solenoidal inductively coupled plasma surrounded by an axial dc magnetic field. The increase in the dc magnetic field caused the EEDF to evolve from a bi-Maxwellian to a Maxwellian distribution. At the discharge center, the number of low energy electrons was significantly reduced while the high energy electron population showed little change when a weak dc magnetic field was present. However, at the discharge radial boundary, the high energy electron population decreased significantly with the magnetic field while the change in low energy population was not prominent compared to the discharge boundary. These changes in EEDFs at the boundary and center of the discharge are due to the radial confinement and the restriction of radial transport of electrons by dc magnetic field.
An amorphous perfluoropolymer, 'Cytop' (Asahi Glass Co., Ltd.), is a preferable material for the fabrication of micro total analysis system devices because of its superior optical transparency over a wide wavelength range and low refractive index of 1.34, which is almost the same as that of water, as well as excellent chemical stability. To establish the precise microfabrication technology for this unique resin, the dry etching of the amorphous perfluoropolymer in Ar/O{sub 2} low-pressure inductively coupled plasma has been studied. A relatively high etch rate of approximately 6.3 {mu}m/min at maximum and highly anisotropic etched features was attained. Plasma measurements by a single Langmuir probe technique and actinometry revealed that etching is dominated by ion-assisted surface desorption above a 10%O{sub 2} mixing ratio, whereas the supply of active oxygen species is the rate-limiting process below 10%. Moreover, angled x-ray photoelectron spectroscopy measurements of an etched trench pattern revealed that a high anisotropy is attributed to the formation of a carbon-rich sidewall protection layer.
One self-consistent method combined with the electromagnetic theory and fluid model is developed to investigate the E-H mode transition of argon inductively coupled plasma (ICP) by adjusting the external electric parameters of the reactor. ICP dynamic characteristics of radial and axial space are also studied when E and H modes coexist. By regulating the radio-frequency current in the coil and voltage across the powered end of the coil and the ground, the E-H mode transition is observed, accompanied by the substantial variations in the electromagnetic field and plasma parameters (density, temperature, and deposited power). Besides, the evolution characteristics of ICP are examined when the discharge mechanism transforms from an E-mode dominated to an H-mode dominated.
We have proposed the novel isotope analysis technique with Resonance Ionization Mass Spectrometry using Inductively Coupled Plasma as an atomic source (ICP-RIMS). Each component of ICP-RIMS is conceptually designed. We conclude that the orthogonal acceleration time-of-flight mass spectrometer (oa-TOF-MS) driven by a high-repetition-rate pulsed laser would be suitable system for ICP-RIMS. We, additionally, suggest that the first vacuum stage of the vacuum interface, which is between the sampling and skimmer cones, is desired to maintain as low pressure as possible in order to suppress the Doppler broadening and to skim the supersonic jet effectively.
We have proposed a novel concept of Resonance Ionization Mass Spectrometry using an Inductively Coupled Plasma as an Atomic Source (ICP-RIMS). Isotope ratio analysis using ICP-RIMS is expected to be a convenient and precise technique with high throughput. However, the mass discrimination effect caused from difference in kinetic energy of neutral atoms in ICP-RIMS is crucial for precise isotope analysis. We, therefore, investigated the atom kinetic energy distribution introduced into the laser ionization region. The mass-dependent kinetic energy was confirmed in the initial kinetic energy distributions. We preliminary estimated a mass discrimination effect caused by mass-dependent kinetic energy in ICP-RIMS for various detector sizes. We proposed that this effect can be suppressed by selecting the appropriate detector size and adopting the scanning mode of the deflecting voltage.