Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Passive Tomography for Spent Fuel Verification: Analysis Framework and Instrument Design Study

The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly is being assessed through a collaboration of Support Programs to the International Atomic Energy Agency (IAEA). In the first phase of this study, two safeguards verification objectives have been identified. The first is the independent determination of the number of active pins that are present in the assembly, in the absence of a priori information. The second objective is to provide quantitative measures of pin-by-pin properties, e.g. activity of key isotopes or pin attributes such as cooling time and relative burnup, for the detection of anomalies and/or verification of operator-declared data. The efficacy of GET to meet these two verification objectives will be evaluated across a range of fuel types, burnups, and cooling times, and with a target interrogation time of less than 60 minutes. The evaluation of GET viability for safeguards applications is founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types are used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. Instrument response data are processed by a variety of tomographic-reconstruction and image-processing methods, and scoring metrics specific to each of the verification objectives are defined and used to evaluate the performance of the methods. This paper will provide a description of the analysis framework and evaluation metrics, example performance-prediction results, and describe the design of a “universal” GET instrument intended to support the full range of verification scenarios envisioned by the IAEA.

spent nuclear fuel assemblies, partial defect veri↗

Outcomes of the JNT 1955 Phase I Viability Study of Gamma Emission Tomography for Spent Fuel Verification

The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly has been assessed within the IAEA Support Program project JNT 1955, phase I, which was completed and reported to the IAEA in October 2016. Two safeguards verification objectives were identified in the project; (1) independent determination of the number of active pins that are present in a measured assembly, in the absence of a priori information about the assembly; and (2) quantitative assessment of pin-by-pin properties, for example the activity of key isotopes or pin attributes such as cooling time and relative burnup, under the assumption that basic fuel parameters (e.g., assembly type and nominal fuel composition) are known. The efficacy of GET to meet these two verification objectives was evaluated across a range of fuel types, burnups and cooling times, while targeting a total interrogation time of less than 60 minutes. The evaluations were founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types were used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. The simulated instrument response data were then processed using a variety of tomographic-reconstruction and image-processing methods, and scoring metrics were defined and used to evaluate the performance of the methods.This paper describes the analysis framework and metrics used to predict tomographer performance. It also presents the design of a “universal” GET (UGET) instrument intended to support the full range of verification scenarios envisioned by the IAEA. Finally, it gives examples of the expected partial-defect detection capabilities for some fuels and diversion scenarios, and it provides a comparison of predicted performance for the notional UGET design and an optimized variant of an existing IAEA instrument.

Jacobsson-Svard, Staffan↗

Electron Beam Induced Thickening of the Protective Oxide Layer around Fe Nanoparticles

There are many circumstances in science where the process of measuring the properties of a system alters the system. An imaging process can exert an inadvertent effect on the object being observed. Consequently, what we observe does not necessarily represent what had been present before the observation. Normally this effect can be ignored if the consequence of such a change is believed not to be significant. The expansion of nanostructured materials has made high resolution transmission electron microscopy one of the indispensable tools for probing the characteristics of nano-materials. Modification of nanoparticles by the electron beam during their imaging has been widely noticed and this is generally believed to be due to electron beam induced heating effect, defect formation in the particles, charging of the particle, or excitation of surrounding gases. However, an explicit experimental identification of which process dominates is often very hard to establish. We report the thickening of native oxide layer on iron nanoparticle under electron beam irradiation. Based on atomic level imaging, electron diffraction, and computer simulation, we have direct evidence that the protecting oxide layer formed on Fe nanoparticle at room temperature in air continues to grow during an electron beam bombardment in the vacuum system typical of most TEM systems. Partial illumination of a nanoparticle and observation of the shell thickening conclusively demonstrates that many of the mechanisms postulated to explain such processes are not occurring to a significant extent. The observed growth is not related to the electron beam induced heating of the nanoparticle, or residual oxygen ionization, or establishment of an electrical field, rather it is related to electron beam facilitated mass transport across the oxide layer (a defect related process).

36 MATERIALS SCIENCE↗

MO-FG-303-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Automating LINAC QA: Design and Testing of An Image Acquisition and Processing System Utilizing a Combination of Radioluminescent Phosphors, Embedded X-Ray Markers and Optical Measurements

Purpose: The recent development of phosphors to visualize radiation beams from linear accelerators (LINAC) offers a unique opportunity for evaluating radiation fields within the context of the treatment space. The purpose of this study was to establish an automated, self-calibrating prototype system for performing quality assurance (QA) measurements. Methods: A thin layer of Gd{sub 2}O{sub 2}S:Tb phosphor and fiducial markers were embedded on several planar faces of a custom-designed phantom. The phantom was arbitrarily placed near iso-center on the couch of a LINAC equipped with on-board megavoltage (MV) and kilovoltage (kV) imagers. A plan consisting of several beams and integrated image acquisitions was delivered. Images of the phantom were collected throughout the delivery. Salient features, such as fiducials, crosshairs and beam edges were then extracted from these images used to calibrate the system, adjust for variations in phantom placement, and perform measurements. Beam edges were visualized by imaging the light generated by the phosphor on the phantom enabling direct comparison with the light field and laser locations. Registration of MV, kV and optical image data was performed using the embedded fiducial markers, enabling comparison of imaging center locations. Measurements specified by TG-142 were calculated and compared with those obtained from a commercially available QA system. Results: The system was able to automatically extract the location of the fiducials, lasers, light field and radiation field from the acquired images regardless of phantom positioning. It was also able to automatically identify the locations of fiducial markers on kV and MV images. All collected measurements were within TG-142 guidelines. The difference between the prototype and commercially available system were less than 0.2 mm. Conclusion: The prototype system demonstrated the capability of accurately and autonomously evaluating various TG-142 parameters independent of operator input and phantom setup.

60 APPLIED LIFE SCIENCES↗

A Nonintrusive Optical Approach to Characterize Heliostats in Utility-Scale Power Tower Plants: Camera Position Sensitivity Analysis

Optics plays a major role in the effectiveness of concentrating solar power (CSP) technologies. The nonintrusive optical (NIO) approach developed by the National Renewable Energy Laboratory uses uncrewed aircraft system (UAS)-based imaging to survey heliostats in a commercial-scale power tower CSP plant and characterize their optical errors. The image processing algorithm uses photogrammetry to calculate the camera position for each image frame, and the accuracy of the estimated optical errors is highly sensitive to the calculated camera position accuracy. In this study, we simulate a series of case studies in python to examine the impact of different parameters of the sensitivity of the camera calculation, including the number of facet corners used as control points for the photogrammetric calculation, precision error in the detected pixel locations of the facet corners in the image, and precision error of the canting and mounting positions of the facets of the heliostat. The case studies consider heliostat geometry based on three commercial designs to serve as representative examples of different possible sizes of heliostats that the NIO method could be applied to. The results show that increasing the number of control points can improve accuracy for heliostats with many facets, pixel precision has a significantly larger impact on camera calculation accuracy than facet canting and mounting errors, and the camera distance and focal length must be chosen to ensure adequate pixel accuracy on the heliostat surface depending on the size of heliostat. In conclusion, based on the results, recommendations for the allowable values of each parameter are provided to achieve the required NIO optical error estimation accuracy depending on the size of heliostat.

14 SOLAR ENERGY↗

Automated Segmentation of Twin Boundaries in TRISO Silicon Carbide Using Deep Neural Networks

Coated particle fuels, such as the tristructural isotropic (TRISO) fuel particle, are essential for high-temperature gas reactor (HTGR) applications due to their efficiency and stability under normal and off-normal conditions. However, widespread commercialization and deployment of this technology for next-generation nuclear applications require robust quality assurance and quality control (QA/QC) methods linking fabrication, properties, and performance. Of the many important metrics for TRISO QA/QC, quantification of the silicon carbide (SiC) microstructure is critical because it correlates with fission product retention during irradiation. Previous work has shown extensive twinning of the SiC microstructure, which strongly affects microstructural metrics; however, twin grain boundaries are not expected play a significant role in fission product diffusion. This report summarizes the initial development, training, and testing of a machine learning image processing algorithm to detect twin grain boundaries in a backscattered electron image, which can be removed so that microstructural metrics can be recalculated for legacy data. Further development and deployment of this model will provide automated, scalable improvement of potential QA/QC methods for the SiC layer of TRISO particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

The quantification accuracy of dual-energy imaging is influenced by the fundamentals of x-ray physics, system geometry, data acquisition hardware/protocol, system calibration, and image processing technique. This symposium will provide updates on the following advanced application areas: Mammography. Volumetric breast density techniques based on standard mammograms require estimation of breast thickness, which is difficult to accurately measure. By comparison, calculation of breast density using dual energy mammography does not require measurement of breast thickness. Dual energy mammography has been implemented using both energy integrating flat panel detectors in conjunction with beam energy switching and energy resolved photon counting detectors. These techniques have been optimized using simulation studies and validated using physical phantoms and postmortem breasts. Chemical decomposition was used as the gold standard for volumetric breast density measurement in postmortem breasts. Breast density measurements have also been compared with results from four-category BI-RADS density rankings, standard image thresholding and Fuzzy k-mean clustering techniques. These studies indicate that dual energy mammography can be used to accurately measure volumetric breast density. Cardiovascular CT. The predicative accuracy of risk models for recurrent stroke and cardiac arrest depends heavily on accurate differentiation of thrombus or calcium from iodine in left atrial appendage or coronary arteries. The amount of energy separation is constrained by image noise; therefore, optimal kVp, beam filtration, and balanced flux are essential for the quantification accuracy of iodine and calcium. The basis materials are combined linearly to generate monochromatic energy images, where CT# accuracy and CNR are energy dependent. With optimal monochromatic energy, the mean iodine concentration for the thrombus, circulatory stasis, and control groups are significantly different. Risk classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application; Understand the different approaches to optimize dual-energy imaging techniques for different applications.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Reconstruction and Microstructure Modeling of Porosity-Graded Cathode Using Focused Ion Beam and Homogenization Techniques

In this study, microstructure of a porosity-graded lanthanum strontium manganite (LSM) cathode of solid oxide fuel cells (SOFCs) has been characterized using focused ion beam (FIB) and scanning electron microscopy(SEM) combined with image processing. Two-point correlation functions of the two-dimensional (2D) images taken along the direction of porosity gradient are used to reconstruct a three-dimensional (3D) microstructure. The effective elastic modulus of the two-phase porosity-graded cathode is predicted using strong contrast (SC) and composite inclusion (CI) homogenization techniques. The effectiveness of the two methods in predicting the effective elastic properties of the porositygraded LSM cathode is investigated in comparison with the results obtained from the finite element model (FEM).

25 ENERGY STORAGE↗

Kinematic fixtures to enable multi-material printing and rapid non-destructive inspection during two-photon lithography

Here, two-photon lithography (TPL) is a polymerization based technique that enables additive manufacturing of millimeter scale parts with submicron features. TPL equipment is often based on retrofitted optical microscopes that lack precise registration capabilities. Consequently, slow and error-prone visual alignment to fiducials is necessary if registration to pre-existing features is required. Herein, we have designed, built, and tested precise kinematic fixtures that are repeatable to within ±315 nm (3σ value) and passively register the build surface to TPL equipment with an accuracy of ±1.7 μm. This enables one to sequentially print with multiple materials by building the structures directly on top of the kinematic fixtures. In addition, the same fixtures passively register to an X-ray computed tomography (CT) system to enable non-destructive 3D inspection that is integrated with the fabrication process. These fixtures (i) provide a practical means to handle micro-scale parts during non-destructive imaging, (ii) reduce the set-up time for X-ray CT from more than an hour to less than a few minutes, and (iii) eliminate operator uncertainty from the multi-material printing and imaging process. As such, these fixtures enable new printing and imaging functionalities that are critical for high-quality additive manufacturing of multi-material polymer parts with microscale and submicron features.

42 ENGINEERING↗

Spot restoration for GPR image post-processing

A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

47 OTHER INSTRUMENTATION↗

Spatially assisted down-track median filter for GPR image post-processing

A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

47 OTHER INSTRUMENTATION↗

Effects of fuel type and equivalence ratios on the flickering of triple flames

An experimental study has been conducted in axisymmetric, co-flowing triple flames with different equivalence ratios of the inner and outer reactant streams (2<{phi}{sub in}<3 and 0{<=}{phi}{sub out}<0.7). Different fuel combinations, like propane/propane, propane/methane or methane/methane in the inner and outer streams respectively, have been used in the experiments. The structures of the triple flames have been compared for the different fuel combinations and equivalence ratios. The conditions under which triple flames exhibit oscillation have been identified. During the oscillation, the non-premixed flame and the outer lean premixed flame flicker strongly, while the inner rich premixed flame remains more or less stable. The flickering frequency has been evaluated through image processing and fast Fourier transform (FFT) of the average pixel intensity of the image frames. It is observed that, for all the fuel combinations, the frequency decreases with the increase in the outer equivalence ratio, while it is relatively invariant with the change in the inner equivalence ratio. However, an increase in the inner equivalence ratio affects the structure of the flame by increasing the heights of the inner premixed flame and non-premixed flame and also enlarges the yellow soot-laden zone at the tip of the inner flame. A scaling analysis of the oscillating flames has been performed based on the measured parameters, which show a variation of Strouhal number (St) with Richardson number (Ri) as St {proportional_to} Ri{sup 0.5}. The fuel type is found to have no influence on this correlation. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation of realistic input parameters for simulating atmospheric point-spread functions at astronomical observatories

High-fidelity simulated astronomical images are an important tool in developing and measuring the performance of image-processing algorithms, particularly for high precision measurements of cosmic shear – correlated distortions of images of distant galaxies due to weak gravitational lensing caused by the large-scale mass distribution in the Universe. For unbiased measurements of cosmic shear, all other sources of correlated image distortions must be modeled or removed. One such source is the correlated blurring of images due to optical turbulence in the atmosphere, which dominates the point-spread function (PSF) for ground-based instruments. In this work, we leverage data from weather forecasting models to produce wind speeds and directions, and turbulence parameters, that are realistically correlated with altitude. To study the resulting correlations in the size and shape of the PSF, we generate simulated images of the PSF across a ~10 square-degree field of view – the size of the camera focal plane for the Vera C. Rubin Observatory in Chile – using weather data and historical seeing for a geographic location near the Observatory. We make quantitative predictions for two-point correlation functions (2PCF) that are used in analyses of cosmic shear. We observe a strong anisotropy in the two-dimensional 2PCF, which is expected based on observations in real images, and study the dependence of the orientation of the anisotropy on dominant wind directions near the ground and at higher altitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

AGR-2 TRISO Layer Thickness Imaging Archive

As a part of fuel quality control characterization, optical microscopy images of particle cross sections near midplane were acquired at Oak Ridge National Laboratory (ORNL). These particles were produced by the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-2 irradiation campaign. These images may be of use for the development of image processing algorithms with the benchmark values measured at ORNL. This report provides those benchmark values, along with the raw images and data generated by the ORNL particle layer thickness analysis process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detailed Modeling of Physical Processes in Electron Sources for Accelerator Applications

At present, electron sources are essential in a wide range of applications – from common technical use to exploring the nature of matter. Depending on the application requirements, different methods and materials are used to generate electrons. State of-the-art accelerator applications set a number of often-contradicting requirements for electron sources (e.g., high quantum efficiency vs. high spin-polarization, high current density vs. long lifetime, etc). Development of advanced electron sources includes modeling and design of cathodes, material growth, fabrication of cathodes, and cathode testing. The detailed simulation and modeling of physical processes are required in order to shed light on the exact mechanisms of electron emission and to develop new-generation electron sources with optimized efficiency. The purpose of the present work is to study physical processes in prominent electron sources and to develop scientific tools that could be used to predict electron emission from novel nano-structured materials. In particular, the Monte Carlo model has been implemented and used to study photoemission from Negative Electron Affinity (NEA) GaAs widely used to provide spin-polarized electron beams for many accelerator facilities, including Thomas Jefferson National Accelerator Facility. According to our best knowledge, this is the first to date scientific tool to simulate the complete from-excitation-to-emission-into-vacuum photoemission of spin-polarized electrons from NEA GaAs based on the details of material band structure. Moreover, an effective image-processing algorithm has been developed and used to study field emission properties of Nitrogen-incorporated UltraNanoCrystalline Diamond ((N)UNCD) films. The algorithm processes large sets of image micrographs representing field emission sites formed on the anode plate and therefore provides significant information about the field emission area and the current density. The field emission model from convenient semiconductors has been modified and used to study the influence of the space-charge region and the electric-field-dependent electron mobility on the field emission characteristics of (N)UNCD field emitters.

Chubenko, Oksana↗

Surface Charge Distribution Mapping Using an Electrostatic Probe

Undesired accumulation of charge on dielectric materials causing electrostatic discharges can be an issue in pulsed power systems and electrical systems in general. As such, an understanding of surface charge distribution, charge accumulation, and decay is required. An in-house no-contact electrostatic probe designed with a 2 mm resolution was fabricated to measure and map surface charge distribution. Designed as a contactless instrument, the probe consisting of a metal rod and low leakage amplifier circuit probes the electric potential near the surface. A scan of the surface then provides the raw data, a potential distribution. The actual probe response - i.e., the surface charge to voltage transfer function, is accounted for in post-processing. This is accomplished via an Inverse Wien Filter - a technique often applied in image processing - to deconvolve the probe response from the measured data. A commercially available electrostatic probe, the Trek 341B meter with a 3455ET probe, capable of measuring +/- 20 kV was compared to the in- house probe that is designed to cover a wider range from +/- 35 kV. A resolution better than the simple probe resolution is achieved through the distribution’s scanning voltage method and deconvolution. Applying repeated scans, surface charge decay was tracked on various polymer materials to determine the material and environment dependence; materials included were PA6, PTFE, and others. As an example of material dependence, samples charged to 20 kV at 65% humidity experience full charge decay in approximately 45 seconds for PA5 (152 mm dia.), while it took about 100 times longer for PTFE (51 mm dia.) to observe the same decay/redistribution of charge.

36 MATERIALS SCIENCE↗

Photoneutron Production Using an Electron Linear Accelerator for Applications in Neutron Imaging

Photoneutron production is possible using an electron linear accelerator and a target capable of generating photonuclear reactions. A short pulse neutron source can be useful for neutron imaging dynamic experiments. This study is aimed at the feasibility of photoneutron production using a 20 MeV electron linear accelerator and tungsten and depleted uranium targets of various thicknesses. MCNP6 (Monte Carlo N-Particle) code will be used to develop a computational model to estimate total neutron yield, and this will be verified at the Idaho State University’s Accelerator Center. After verification of the neutron yield and energy spectra, an additional MCNP6 model will be developed to analyze the neutron imaging processes. This study will potentially prove it is possible to conduct multi-mode imaging experiments on the anticipated Scorpius electron linear accelerator at the Nevada National Security Sites.

43 PARTICLE ACCELERATORS↗

FL V1.3

A library of utility classes for computer vision. Contains implementations of various well-known image processing techniques, such as interest point operators and region descriptors. Includes interfaces to various libraries for image and video I/O, as well as an interface to LAPACK/BLAS. FL was developed at the University of Illinois, Urbana-Champaign (UIUC) and released under an open source license. Version 1.2 was a maintenance release provided by SNL under the LGPL license. Version 1.3 is a maintenance release, containing the following changes: - Improved image format handling. Now handles strided and planar memory layouts and a wider range of pixel formats. - Improved image file I/O, including better support for metadata, a wider range of stored pixel types, and a couple of new file formats. - Improvements to DOG and SIFT, and efficiency improvements in low-level convolution. - Improvements to networking, including a generic TCP listener. - Various improvements to numerical processing. The HISTORY file included in the distribution contains a more detailed description of the changes.

Rothganger, Frederick↗