Combinatorial and High-Throughput Materials Synthesis to Advanced Nuclear Materials Discovery
Poster for end of LDRD project
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Poster for end of LDRD project
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 10 12 photons s −1 ), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.
Abstract Synchrotron X‐ray‐based in situ metrology is advantageous for monitoring the synthesis of battery materials, offering high throughput, high spatial and temporal resolution, and chemical sensitivity. However, the rapid generation of massive data poses a challenge to on‐site, on‐the‐fly analysis needed for real‐time process monitoring. Here, a weighted lagged cross‐correlation (WLCC) similarity approach is presented for automated data analysis, which merges with in situ synchrotron X‐ray diffraction metrology to monitor the calcination process of the archetypal nickel‐based cathode, LiNiO 2 . The WLCC approach, incorporating variables that account for peak shifts and width changes associated with structural transformations, enables rapid extraction of phase progression within 10 seconds from tens of diffraction patterns. Details are captured, from initial precursors to intermediates and the final layered LiNiO 2 , providing information for agile on‐site adjustments during experiments and complementing post hoc diffraction analysis by offering insights into early‐stage phase nucleation and growth. Expanding this data‐powered platform paves the way for real time calcination process monitoring and control, which is pivotal to quality control in battery cathode manufacturing.
In this work, we introduce an open-source Julia project, express, an extensible, lightweight, high-throughput, high-level workflow framework that aims to automate ab initio calculations for the materials science community. express is shipped with well-tested workflow templates, including structure optimization, equation of state (EOS) fitting, phonon spectrum (lattice dynamics) calculation, and thermodynamic property calculation in the framework of the quasi-harmonic approximation (QHA). It is designed to be highly modularized so that its components can be reused across various occasions, and customized workflows can be built on top of that. Users can also track the status of workflows in real-time, and rerun failed jobs thanks to the data lineage feature express provides. Finally, two working examples, i.e., all workflows applied to lime and akimotoite, are also presented in the code and this paper.
he wide band gap semiconducting perovskite BaSnO 3 is of high current interest due to outstanding room temperature mobility at high electron density, fueled by potential applications in oxide, transparent, and power electronics. Due in part to a lack of lattice-matched substrates, BaSnO 3 thin films suffer from high defect densities, however, limiting electron mobility. Additionally, the vast majority of BaSnO 3 thin film research has focused on pulsed laser deposition or molecular beam epitaxy. In this work, we present an exhaustive optimization of the mobility of Ba 0.98 La 0.02 SnO 3 films grown by a scalable, high-throughput method: high-pressure-oxygen sputter deposition. Considering target synthesis conditions, substrate selection, buffer layer structure, deposition temperature, deposition rate, thickness, and postdeposition annealing conditions, and by combining high-resolution x-ray diffraction, reciprocal space mapping, rocking curve analysis, scanning transmission electron microscopy, atomic force microscopy, and temperature-dependent electronic transport measurements, detailed understanding of synthesis-structure-property relationships is attained. Optimized room temperature mobility of 96 cm 2 V –1 s –1 is achieved in vacuum-annealed GdScO 3 (110)/BaSnO 3 (120 nm)/Ba 0.98 La 0.02 SnO 3 (200 nm) heterostructures, as well as 92 cm 2 V –1 s –1 on unbuffered substrates and 87 2 V –1 s –1 without postdeposition annealing. These results, including important trends in defect densities and a surprising dependence of mobility on lattice mismatch, substantially expand the understanding of the interplay between deposition conditions, microstructure, and transport in doped BaSnO 3 films, establishing competitive mobilities in films fabricated via a scalable, high-throughput, industry-standard technique.
High‐throughput experimental approaches to rapidly develop new materials require high‐throughput data analysis methods to match. Spectroscopic ellipsometry is a powerful method of optical properties characterization, but for unknown materials and/or layer structures the data analysis using traditional methods of nonlinear regression is too slow for autonomous, closed‐loop, high‐throughput experimentation. Herein, three methods (termed spectral, piecewise, and pointwise) of spectroscopic ellipsometry data analysis based on deep learning are introduced and studied. After initial training, the incremental time for inferring optical properties can be a thousand times faster than traditional methods. Results for multilayer sample structures with optically isotropic materials are presented, appropriate for high‐throughput studies of thin films of phase‐change materials such as GeSbTe (GST) alloys. Results for studies on highly birefringent layered materials are also presented, exemplified by the transition metal dichalcogenide MoS 2 . How the materials under test and the experimental objectives may guide the choice of analysis methods are discussed. The utility of our approach is demonstrated by analyzing data measured on a composition spread of GeSbTe phase‐change alloys containing 177 distinct compositions, and identifying the composition with optimal phase‐change figure of merit in only 1.4 s of analysis time.
Purpose: This project seeks to demonstrate a new high-throughput (rapid) alloy design technique applied to creating new high entropy alloys (HEAs) for extreme environments. High entropy alloys shift the design paradigm from being focused on a single principal element (e.g. nickel-based alloys) to target alloys that include high atomic fractions (X >10%) of multiple elements. These HEA materials can exhibit sluggish diffusion and enhanced corrosion resistance, ideal for potential applications in advanced ultra supercritical (A-USC) steam cycles for power generation. Scope: The addition of multiple elements in high atomic fractions creates an enormous design space that cannot easily be investigated by traditional material design strategies such as designed of experiments (DOE). This project utilizes a Bayesian machine learning algorithm that has been modified to work with calculation of phase diagrams (CALPHAD) software. This Bayesian algorithm reduces manual inputs and increase the likelihood of achieving an optimal solution. Compositional inputs to this algorithm will be assessed using existing material property models for high temperature strength and corrosion resistance. The target for alloy performance will be a 15% (~100 ⁰C) increase in allowable service temperature beyond heat-resistant stainless steels while maintaining or improving alloy cost and corrosion resistance. Haynes 230 was selected as a baseline, which is 57 wt% Ni with 22 wt% Cr 14 wt% W, and 2 wt% Mo as solid solution strengtheners. In addition to rapid design via Bayesian machine learning, the alloys were rapidly fabricated using a multi-wire arc additive manufacturing (mWAAM) technique which allows for precise control of alloy composition and assessing of alloy design “windows” to study composition effects. Build speeds for wire-arc additive processes are among the highest for additive technologies enabling rapid and reliable sample fabrication when compared to conventional methods such as arc button melting. The mWAAM samples will be rapidly characterized via instrumented indentation for room temperature modulus and strength and for elevated temperature strength via hot hardness tests. After being screened with hardness testing, potential alloys will be further evaluated with conventional microscopy techniques including scanning electron microscopy (SEM) and transmission electron microscopy (TEM) to assess agreement with modeling results. The most promising compositions will also be evaluated by printing full sized tensile specimens for mechanical behavior tests at elevated temperatures. Results: Bayesian machine learning of a single performance function was initially used to optimize five performance metrics: 1) single phase stability, 2) yield strength, 3) creep resistance (low diffusion coefficient), 4) freezing range (weldability), and 5) material cost. The single performance function was suboptimal as assumptions had to be made about the results while formulating the optimization. A goal-oriented Bayesian optimization strategy (Hanaoka, 2021) was implemented with CALPHAD for use with the five metrics above. This multi-objective Bayesian optimization (MOBO) enabled the design of NiCrCoFe alloys with V and W additions. A base composition of NiCoCr was selected as Ni provides a stable FCC matrix, Cr aids corrosion/oxidation resistance, and Co is a solid-solutions strengthener that also improves creep by increasing the activation energy. Fe helps reduce diffusion coefficients and cost. Finally, V and W were selected for their reasonable solubility and high atomic misfit to aid in solid solution strengthening. Cracking of the mWAAM specimens was an early issue, and the Easton solidification cracking model (Easton et al., 2014a) was selected for addition to the MOBO function. High performing alloys fabricated by mWAAM included Ni 28 Cr 25 Co 26 Fe 15 V 8 and Ni 62 Cr 18 Co 1 Fe 3 W 15 . It was observed that even after adapting the mWAAM process for W, the W did not fully dissolve. To fully evaluate the Ni 62 Cr 18 Co 1 Fe 3 W 15 composition, a cored wire (80-20 NiCr sheath/powder core) was manufactured and printed via WAAM, and HIP’ing was utilized to homogenize and densify the printed alloy. The V and W alloys produced met metrics 1 (solid solution), 4 (solidification cracking), and 5 (cost). However, an unmodeled mechanism of thermal stress cracking was identified in the WAAM produced materials, perhaps exacerbated by the lack of grain boundary strengthening elements (B, C). Conclusions & Recommendations: A high-throughput (rapid) alloy design technique was applied to designing and manufacturing new high entropy alloys (HEAs) for extreme environments utilizing MOBO and mWAAM. The developed process was rapid and effective in addressing the mechanisms included in the model. The lack of grain boundary strengthening element additions (e.g., B, C) was a simplification that likely produced thermal stress cracking that turned into a large part of the investigation. Additions on the order of 0.005 wt% B and 0.05 wt% C likely would have minimized thermal stress grain boundary cracking. Overall, the high throughput design strategy is promising for rapid design of metrics-driven alloys for advanced ultra supercritical (A-USC) steam cycles for power generation. The MOBO and mWAAM process could be commercialized to accelerate metrics-driven alloy design. In addition, the cored-wire process utilized for scale-up is a promising high-volume process for WAAM alloy development and scale-up.
Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.
As metabolomics grows into a high-throughput and high demand research field, current metrics for the identification of small molecules in gas chromatography–mass spectrometry (GC–MS) still require manual verification. Though steps have been taken to improve scoring metrics by combining spectral similarity (SS) and retention index (RI), the problem persists. A large body of literature has analyzed and refined SS scores, but few studies have explicitly studied improvements to RI scores. Here, in this study, we examined whether uninvestigated assumptions of the RI score are valid and propose ways to improve them. Query RIs were matched to library RI with a generous window of ±35 to avoid unintentional removal of valid compound identifications. Each match was manually verified as a true positive (TP), true negative, or unknown. Metabolites with at least 30 TP identifications were included in downstream analyses, resulting in a total of 87 metabolites from samples of varying complexity and type (e.g., amino acid mixtures, human urine, fungal species, and so on.). Our results showed that the RI score assumptions of normality, consistent variance across metabolites, and a mean error centered at 0 are often violated. We demonstrated through a cross-validation analysis that modifying these underlying assumptions according to empirical metabolite-specific distributions improved the TP and negative rankings. Further, we statistically determined the minimum number of samples required to estimate distributional parameters for scoring metrics. Overall, this work proposes a robust statistical pipeline to reduce the time bottleneck of metabolite identification by improving RI scores and thus minimize the effort to complete manual verification.
Approaches to tackle the wide and growing variety of highly persistent per- and polyfluoroalkyl substances (PFAS) are of pressing global need because of their detrimental human health effects, such as cancer, birth defects, and hormone imbalance. Sensitive, selective, and easy-to-use real-time sensors to monitor and detect PFAS and sorbents to extract them are critical to meeting government-mandated environmental concentrations. In this work, we combine all-atom molecular dynamics simulations, enhanced sampling, deep representational learning, and Bayesian optimization to perform high-throughput virtual screening for highly sensitive and selective molecular probes. Our molecular design space consists of 3850 linear hydrocarbon chains with varying degrees of halogenation with and without amine- and phosphine-based headgroups. By employing a data-driven search process, we efficiently explore the molecular design space to optimize the sensitivity to perfluorooctanesulfonic acid (PFOS) as a prototypical PFAS analyte and selectivity relative to a sodium dodecyl sulfate (SDS) interferent. We calculate 504 Gibbs free energies of probe-analyte and probe-interferent interactions and identify probes with PFOS association free energies of up to (-ΔG PFOS ) = 9.8 ± 0.2 kJ/mol and selectivities relative to SDS of (-ΔΔG PFOS–SDS ) = 3.1 ± 1.5 kJ/mol. A C 11 Br 23 P(CH 3 ) 2 probe containing 11 backbone brominated carbons and a tertiary phosphine headgroup possesses the most sensitive binding constant to PFOS within the defined search space of K b PFOS = 177.4 ± 12.7, and a semibrominated probe C 5 H 11 C 7 Br 14 N(CH 3 ) 2 containing 12 backbone carbons and a tertiary amine headgroup possesses the highest selectivity relative to SDS of K b PFOS /K b SDS = 4.6 ± 1.7. A retrospective analysis of our data to extract interpretable design rules reveals that the sensitivity of linear hydrogenated probes increases by approximately 1 kJ/mol per C–C bond. The addition or removal of halogen atoms and amine or phosphine headgroups produces nonmonotonic changes in both sensitivity and selectivity with changes to the sensitivity of up to 2.5 kJ/mol. Finally, this work places empirical limitations on the performance of a wide range of linear probes for PFOS detection and offers a generic strategy for high-throughput computational screening to promote selective and sensitive binding.
Current approaches for single molecule force spectroscopy are typically constrained by low throughput and high instrumentation cost. Herein, a low-cost, high throughput technique is demonstrated using microfluidics for multiplexed mechanical manipulation of up to ~4000 individual molecules via molecular fluid loading on-a-chip (FLO-Chip). The FLO-Chip consists of serially connected microchannels with varying width, allowing for simultaneous testing at multiple loading rates. Molecular force measurements are demonstrated by dissociating Biotin-Streptavidin and Digoxigenin-AntiDigoxigenin interactions along with unzipping of double stranded DNA of varying sequence under different dynamic loading rates and solution conditions. Rupture force results under varying loading rates and solution conditions are in good agreement with prior studies, verifying a versatile approach for single molecule biophysics and molecular mechanobiology. FLO-Chip enables straightforward, rapid, low-cost, and portable mechanical testing of single molecules that can be implemented on a wide range of microscopes to broaden access and may enable new applications of molecular force spectroscopy.
Electrophysiological mapping of chronic atrial fibrillation (AF) at high throughput and high resolution is critical for understanding its underlying mechanism and guiding definitive treatment such as cardiac ablation, but current electrophysiological tools are limited by either low spatial resolution or electromechanical uncoupling of the beating heart. To overcome this limitation, here we introduce a scalable method for fabricating a tissue-like, high-density, fully elastic electrode (elastrode) array capable of achieving real-time, stable, cellular level-resolution electrophysiological mapping in vivo. Testing with acute rabbit and porcine models, the device is proven to have robust and intimate tissue coupling while maintaining its chemical, mechanical, and electrical properties during the cardiac cycle. The elastrode array records epicardial atrial signals with comparable efficacy to currently available endocardial-mapping techniques but with 2 times higher atrial-to-ventricular signal ratio and >100 times higher spatial resolution and can reliably identify electrical local heterogeneity within an area of simultaneously identified rotor-like electrical patterns in a porcine model of chronic AF.
GNU Parallel is a versatile and powerful tool for process parallelization widely used in scientific computing. This paper demonstrates its effective application in high-performance computing (HPC) environments, particularly focusing on its scalability and efficiency in executing large-scale high-throughput high-performance computing (HT-HPC) workflows. Through real-world examples, we highlight GNU Parallel’s performance across various HPC workloads, including GPU computing, container-based workloads, and node-local NVMe storage. Our results on two leading supercomputers, OLCF’s Frontier and NERSC’s Perlmutter, showcase GNU Parallel’s rapid process dispatching ability and its capacity to maintain low overhead even at extreme scales. We explore GNU Parallel’s application in massive parallel file transfers using a scheduled Data Transfer Node (DTN) cluster, emphasizing its broad utility in diverse scientific workflows. Beyond its direct application as a viable workflow manager, GNU Parallel can be employed in conjunction with other workflow systems as a "last-mile" parallelizing driver and as a quick prototyping tool to design and extract parallel profiles from application executions. We then argue that the potential for GNU Parallel to transform workflow management at extreme scales is substantial, paving the way for more efficient and effective scientific discoveries.
Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.
A general method of separating isotopes by centrifuging dissolved chemical compounds in a liquid is introduced. This technique can be applied to almost all elements and leads to large separation factors. The method has been demonstrated in several isotopic systems including Ca, Mo, O, and Li with single-stage selectivities of 1.046 to 1.067 per neutron mass difference (e.g., 1.43 in 40 Ca/ 48 Ca), which are beyond the capabilities of various conventional methods. Equations are derived to model the process, and the results agree with those of the experiments. The scalability of the technique has been demonstrated by a three-stage enrichment of 48 Ca with a total 40 Ca/ 48 Ca selectivity of 2.43, and the scalability is more broadly supported through analogies to gas centrifuge, whereby countercurrent centrifugation can further multiply the separation factor by 5 to 10 times per stage in a continuous process. Optimal centrifuge conditions and solutions can achieve both high-throughput and highly efficient isotope separation.