At least 595 records · Page 33

TH-CD-BRA-03: Direct Measurement of Magnetic Field Correction Factors, KQB, for Application in Future Codes of Practice for Reference Dosimetry

Purpose: With an MR-linac, radiation is delivered in the presence of a magnetic field. Modifications in the codes of practice (CoPs) for reference dosimetry are required to incorporate the effect of the magnetic field. Methods: In most CoPs the absorbed dose is determined using the well-known kQ formalism as the product of the calibration coefficient, the corrected electrometer reading and kQ, to account for the difference in beam quality. To keep a similar formalism a single correction factor is introduced which replaces kQ, and which corrects for beam quality and B-field, kQ,B. In this study we propose a method to determine kQ,B under reference conditions in the MRLinac without using a primary standard, as the product of:- the ratio between detector readings without and with B-field (kB),- the ratio between doses in the point of measurement with and without B-field (rho),- kQ in the absence of the B-field in the MRLinac beam (kQmrl0,Q0),The ratio of the readings, which covers the change in detector reading due to the different electron trajectories in the detector, was measured with a waterproof ionization chamber (IBA-FC65g) in a water phantom in the MRLinac without and with B-field. The change in dose-to-water in the point of measurement due to the B-field was determined with a Monte Carlo based TPS. Results: For the presented approach, the measured ratio of readings is 0.956, the calculated ratio of doses in the point of measurement is 0.995. Based on TPR20,10 measurements kQ was calculated as 0.989 using NCS-18. This yields a value of 0.9408 for kQ,B. Conclusion: The presented approach to determine kQ,B agrees with a method based on primary standards within 0.4% with an uncertainty of 1% (1 std.uncert). It differs from a similar approach using a PMMA-phantom and an NE2571 chamber with 1.3%.

60 APPLIED LIFE SCIENCES↗

Solving PDEs in Irregular Geometries with Multiresolution Methods I: Embedded Dirichlet Boundary Conditions

In this work, we develop and analyze a formalism for solving boundary value problems in arbitrarily-shaped domains using the MADNESS (multiresolution adaptive numerical environment for scientific simulation) package for adaptive computation with multiresolution algorithms. We begin by implementing a previously-reported diffuse domain approximation for embedding the domain of interest into a larger domain (Li et al., 2009 [1]). Numerical and analytical tests both demonstrate that this approximation yields non-physical solutions with zero first and second derivatives at the boundary. This excessive smoothness leads to large numerical cancellation and confounds the dynamically-adaptive, multiresolution algorithms inside MADNESS. We thus generalize the diffuse domain approximation, producing a formalism that demonstrates first-order convergence in both near- and far-field errors. We finally apply our formalism to an electrostatics problem from nanoscience with characteristic length scales ranging from 0.0001 to 300 nm.

99 GENERAL AND MISCELLANEOUS↗

Auxiliary matrix formalism for interaction representation transformations, optimal control, and spin relaxation theories

Auxiliary matrix exponential method is used to derive simple and numerically efficient general expressions for the following, historically rather cumbersome, and hard to compute, theoretical methods: (1) average Hamiltonian theory following interaction representation transformations; (2) Bloch-Redfield-Wangsness theory of nuclear and electron relaxation; (3) gradient ascent pulse engineering version of quantum optimal control theory. In the context of spin dynamics, the auxiliary matrix exponential method is more efficient than methods based on matrix factorizations and also exhibits more favourable complexity scaling with the dimension of the Hamiltonian matrix.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration of the Gamma Knife Perfexion using TG-21 and the solid water Leksell dosimetry phantom

Purpose: To calibrate a Gamma Knife (GK) Perfexion using TG-21 with updated chamber-dependent values for modern microionization chambers in the new solid water Leksell dosimetry phantom. This work illustrates a calibration method using commercially available equipment, instruments, and an established dosimetry protocol that may be adopted at any GK center, thus reducing the interinstitutional variation in GK calibration. The calibration was verified by three third-party dosimetry checks. In addition, measurements of the relative output factors are presented and compared to available data and the new manufacturer-provided relative output factors yet to be released. Methods: An absolute dose calibration based on the TG-21 formalism, utilizing recently reported phantom material and chamber-dependent factors, was performed using a microionization chamber in a spherical solid water phantom. The result was compared to other calibration protocols based on TG-51. Independent verification of the machine output was conducted through M.D. Anderson Dosimetry Services (MDADS), using thermoluminescent dosimeters (TLDs) in an anthropomorphic head phantom; the Radiological Physics Center (RPC), using TLDs in the standard Elekta ABS plastic calibration phantom (gray phantom), included with the GK; and through a collaborative international calibration survey by the University of Pittsburgh Medical Center (UPMC) using alanine dosimeters, also in the gray phantom. The alanine dosimeters were read by the National Institute of Standards and Technology. Finally, Gafchromic EBT film was used to measure relative output factors and these factors were compared to values reported in the literature as well as new values announced for release by Elekta. The films were exposed in the solid water phantom using an included film insert accessory. Results: Compared to the TG-21 protocol in the solid water phantom, the modified and unmodified TG-51 calibrations resulted in dose rates which were 1.8% and 1.3% lower, respectively. Ratios of the doses measured by third parties to the dose reported showed excellent agreement. MDADS returned ratios of 1.00 and 0.98 for the two TLDs irradiated. The RPC returned a mean ratio of 0.98 of the dose reported and the UPMC alanine study returned a mean ratio of 1.008. Relative output factors were found to be 0.817{+-}0.009 and 0.897{+-}0.008 for the 4 and 8 mm collimators, respectively, which are in excellent agreement with revised Monte Carlo-derived relative output factors Elekta is expected to recommend with the next version of the GK treatment planning software (GAMMAPLAN version 10). Conclusions: The TG-21 dosimetry protocol, performed in a solid water phantom in conjunction with modern dosimeters and phantom material and chamber-dependent factors, can yield an accurate dose measurement in the unique GK treatment geometry. The technique described here can be easily adopted by institutions worldwide since all equipment and instruments used are commercially available, thus reducing the existing interinstitutional variation in GK calibration techniques. Relative output factor measurements made in this same solid water phantom were used to verify the relative output factors provided by Elekta and agreed excellently with output factors expected to be released in conjunction with GAMMAPLAN version 10.

60 APPLIED LIFE SCIENCES↗

Formal analysis of device authentication applications in ubiquitous computing.

Authentication between mobile devices in ad-hoc computing environments is a challenging problem. Without pre-shared knowledge, existing applications rely on additional communication methods, such as out-of-band or location-limited channels for device authentication. However, no formal analysis has been conducted to determine whether out-of-band channels are actually necessary. We answer this question through formal analysis, and use BAN logic to show that device authentication using a single channel is not possible.

99 GENERAL AND MISCELLANEOUS↗

Four‐Electron Oxidative Addition of an N=N Double Bond at a Chromium Metallocyclopropene**

Abstract This report describes the synthesis of a pseudo‐tetrahedral chromium alkyne complex supported by a bidentate phosphinimide ligand and its reactivity with an azobenzene derivative. Characterization of the former by structural and computational methods reveals an unprecedented extent of alkyne activation by a formal chromium(II) center, suggesting that this complex is best described as a chromium(IV)‐metallocyclopropene. Exposure of this compound to 4,4′‐difluoroazobenzene results in the formation of a chromium(VI) diimido complex, which constitutes a rare 4‐electron oxidative addition of an N=N double bond. The isolation of a chromium(IV)‐hydrazido intermediate enabled mechanistic investigations of this challenging bond cleavage process. This work substantiates the notion that terminal phosphinimide ligands can engender first‐row transition metal ions with exceptional reactivity.

Chemistry↗

Optimized recursion relation for the computation of partition functions in the superconfiguration approach

Partition functions of a canonical ensemble of non-interacting bound electrons are a key ingredient of the super-transition-array approach to the computation of radiative opacity. A few years ago, we published a robust and stable recursion relation for the calculation of such partition functions. In this work, we propose an optimization of the latter method and explain how to implement it in practice. The formalism relies on the evaluation of elementary symmetric polynomials, which opens the way to further improvements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron ionization of open/closed chain isocarbonic molecules relevant in plasma processing: Theoretical cross sections

In this paper, we report theoretical electron impact ionization cross sections from threshold to 2000 eV for isocarbonic open chain molecules C{sub 4}H{sub 6}, C{sub 4}H{sub 8}, C{sub 4}F{sub 6} including their isomers, and closed chain molecules c-C{sub 4}H{sub 8} and c-C{sub 4}F{sub 8}. Theoretical formalism employed presently, viz., Complex Scattering Potential-ionization contribution method has been used successfully for a variety of polyatomic molecules. The present ionization calculations are very important since results available for the studied targets are either scarce or none. Our work affords comparison of C{sub 4} containing hydrocarbon versus fluorocarbon molecules. Comparisons of the present ionization cross sections are made wherever possible, and new ionization data are also presented.

2-METHYLPROPENE↗

BAYESIAN INFERENCE OF SOLAR AND STELLAR MAGNETIC FIELDS IN THE WEAK-FIELD APPROXIMATION

The weak-field approximation is one of the simplest models that allows us to relate the observed polarization induced by the Zeeman effect with the magnetic field vector present on the plasma of interest. It is usually applied for diagnosing magnetic fields in the solar and stellar atmospheres. A fully Bayesian approach to the inference of magnetic properties in unresolved structures is presented. The analytical expression for the marginal posterior distribution is obtained, from which we can obtain statistically relevant information about the model parameters. The role of a priori information is discussed and a hierarchical procedure is presented that gives robust results that are almost insensitive to the precise election of the prior. The strength of the formalism is demonstrated through an application to IMaX data. Bayesian methods can optimally exploit data from filter polarimeters given the scarcity of spectral information as compared with spectro-polarimeters. The effect of noise and how it degrades our ability to extract information from the Stokes profiles is analyzed in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

A GODUNOV METHOD FOR MULTIDIMENSIONAL RADIATION MAGNETOHYDRODYNAMICS BASED ON A VARIABLE EDDINGTON TENSOR

We describe a numerical algorithm to integrate the equations of radiation magnetohydrodynamics in multidimensions using Godunov methods. This algorithm solves the radiation moment equations in the mixed frame, without invoking any diffusion-like approximations. The moment equations are closed using a variable Eddington tensor whose components are calculated from a formal solution of the transfer equation at a large number of angles using the method of short characteristics. We use a comprehensive test suite to verify the algorithm, including convergence tests of radiation-modified linear acoustic and magnetosonic waves, the structure of radiation-modified shocks, and two-dimensional tests of photon bubble instability and the ablation of dense clouds by an intense radiation field. These tests cover a very wide range of regimes, including both optically thick and thin flows, and ratios of the radiation to gas pressure of at least 10{sup -4}-10{sup 4}. Across most of the parameter space, we find that the method is accurate. However, the tests also reveal there are regimes where the method needs improvement, for example when both the radiation pressure and absorption opacity are very large. We suggest modifications to the algorithm that will improve the accuracy in this case. We discuss the advantages of this method over those based on flux-limited diffusion. In particular, we find that the method is not only substantially more accurate, but often no more expensive than the diffusion approximation for our intended applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of semi-analytical, semi-empirical covariance matrices for two-point correlation function for early DESI data

ABSTRACT We present an extended validation of semi-analytical, semi-empirical covariance matrices for the two-point correlation function (2PCF) on simulated catalogs representative of luminous red galaxies (LRGs) data collected during the initial 2 months of operations of the Stage-IV ground-based Dark Energy Spectroscopic Instrument (DESI). We run the pipeline on multiple effective Zel’dovich (EZ) mock galaxy catalogs with the corresponding cuts applied and compare the results with the mock sample covariance to assess the accuracy and its fluctuations. We propose an extension of the previously developed formalism for catalogs processed with standard reconstruction algorithms. We consider methods for comparing covariance matrices in detail, highlighting their interpretation and statistical properties caused by sample variance, in particular, non-trivial expectation values of certain metrics even when the external covariance estimate is perfect. With improved mocks and validation techniques, we confirm a good agreement between our predictions and sample covariance. This allows one to generate covariance matrices for comparable data sets without the need to create numerous mock galaxy catalogs with matching clustering, only requiring 2PCF measurements from the data itself. The code used in this paper is publicly available at https://github.com/oliverphilcox/RascalC.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectra, triple, and quartic gauge couplings in a Higgsless model

Spectra, triple, and quartic gauge couplings of the Higgsless model with gauge group SU(2){sub L}xSU(2){sub R}xU(1){sub B-L} defined in warped space are explored with a numerical method. We extend the equation of motions, boundary conditions, and formalism of multi-gauge-boson vertices to the Hirn-Sanz scenario. By assuming the ideally delocalized fermion profile, we study the spectra of vector bosons as well as the triple and quartic gauge couplings among vector bosons. It is found that mass spectra can be greatly modified by the parameters of QCD power corrections. Meanwhile, the triple and quartic gauge couplings can deviate from the values of the standard model to at least {+-}10% and can saturate the LEP2 bounds. We find the triple gauge couplings of ZWW can be 50% smaller than the unitarity bounds. The triple gauge couplings of ZWW is 20% smaller than the unitarity bounds, which might challenge the detection of Z via s channel at LHC if m{sub Z}>500 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation reaction and gravitational waves in the effective field theory approach

We compute the contribution to the Lagrangian from the leading order (2.5 post-Newtonian) radiation reaction and the quadrupolar gravitational waves emitted from a binary system using the effective field theory (EFT) approach of Goldberger and Rothstein. We use an initial value formulation of the underlying (quantum) framework to implement retarded boundary conditions and describe these real-time dissipative processes. We also demonstrate why the usual scattering formalism of quantum field theory inadequately accounts for these. The methods discussed here should be useful for deriving real-time quantities (including radiation reaction forces and gravitational wave emission) and hereditary terms in the post-Newtonian approximation (including memory, tail and other causal, history-dependent integrals) within the EFT approach. We also provide a consistent formulation of the radiation sector in the equivalent effective field theory approach of Kol and Smolkin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiple parton interactions in hadron collisions and diffraction

Hadrons are composite objects made of quarks and gluons, and during a collision one can have several elementary interactions between the constituents. These elementary interactions, using an appropriate theoretical framework, can be related to the total and elastic cross sections. At high c.m. energy it also becomes possible to identify experimentally a high p{sub perpendicular} subset of the parton interactions and to study their multiplicity distribution. Predictions of the multiple interaction rates are difficult because in principle one needs to have a knowledge of the correlated parton distribution functions that describe the probability to find simultaneously different partons in different elements of phase space. In this work we address this question and suggest a method to describe effectively the fluctuations in the instantaneous configuration of a colliding hadron. This problem is intimately related to the origin of the inelastic diffractive processes. We present a new method to include the diffractive cross section in an eikonal formalism that is equivalent to a multichannel eikonal. We compare with data and present an extrapolation to higher energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combine many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm{sup 3} idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a high-energy proton beam. Jefferson Sorriaux is financed by the Walloon Region under the convention 1217662. Jefferson Sorriaux is sponsored by a public-private partnership IBA - Walloon Region.

60 APPLIED LIFE SCIENCES↗

The challenges of theory-software translation

Background: Software is now ubiquitous within research. In addition to the general challenges common to all software development projects, research software must also represent, manipulate, and provide data for complex theoretical constructs. Ensuring this process of theory-software translation is robust is essential to maintaining the integrity of the science resulting from it, and yet there has been little formal recognition or exploration of the challenges associated with it. Methods: We thematically analyse the outputs of the discussion sessions at the Theory-Software Translation Workshop 2019, where academic researchers and research software engineers from a variety of domains, and with particular expertise in high performance computing, explored the process of translating between scientific theory and software. Results: We identify a wide range of challenges to implementing scientific theory in research software and using the resulting data and models for the advancement of knowledge. We categorise these within the emergent themes of design, infrastructure, and culture, and map them to associated research questions. Conclusions: Systematically investigating how software is constructed and its outputs used within science has the potential to improve the robustness of research software and accelerate progress in its development. We propose that this issue be examined within a new research area of theory-software translation, which would aim to significantly advance both knowledge and scientific practice.