Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FRAMING CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Video Guidance Sensor Flight Experiment Results

NASA's Marshall Space Flight Center flew on the STS-87 mission an active sensor system, the Video Guidance Sensor (VGS), to demonstrate its functioning in space and to collect performance data. The VGS was designed to provide near-range sensor data as part of an automatic rendezvous and docking system. The sensor determines the relative positions and attitudes between the active sensor and the passive target. The VGS uses laser diodes to illuminate retro-reflectors in the target, a solid-state camera to detect the return from the target, and a frame grabber and digital signal processor to convert the video information into the relative positions and attitudes. The system is designed to operate with the target within a relative azimuth of +/- 9.5 degrees and a relative elevation of +/- 7.5 degrees. The system will acquire and track the target within that field-of-view anywhere from 1.5 meters to 110 meters range, and is designed to acquire at relative attitudes of +/- 10 degrees in pitch and yaw and at any roll angle. The data is output from the sensor at 5 Hz, and the target and sensor software have been designed to permit two independent sensors to operate simultaneously (in order to allow for redundancy). The data from the flight experiment includes raw video data from the VGS camera, relative position and attitude measurements from the VGS to the target, independent hand-held laser ranges from the Shuttle Aft Flight Deck to the target, and Remote Manipulator System position data to correlate with the VGS data. The experiment was quite successful and returned much useful information. The experience gained from the design and flight of this experiment will lead to improved video sensors in the future.

Howard, Richard T.↗

Wide-Field-of-View, High-Resolution, Stereoscopic Imager

A device combines video feeds from multiple cameras to provide wide-field-of-view, high-resolution, stereoscopic video to the user. The prototype under development consists of two camera assemblies, one for each eye. One of these assemblies incorporates a mounting structure with multiple cameras attached at offset angles. The video signals from the cameras are fed to a central processing platform where each frame is color processed and mapped into a single contiguous wide-field-of-view image. Because the resolution of most display devices is typically smaller than the processed map, a cropped portion of the video feed is output to the display device. The positioning of the cropped window will likely be controlled through the use of a head tracking device, allowing the user to turn his or her head side-to-side or up and down to view different portions of the captured image. There are multiple options for the display of the stereoscopic image. The use of head mounted displays is one likely implementation. However, the use of 3D projection technologies is another potential technology under consideration, The technology can be adapted in a multitude of ways. The computing platform is scalable, such that the number, resolution, and sensitivity of the cameras can be leveraged to improve image resolution and field of view. Miniaturization efforts can be pursued to shrink the package down for better mobility. Power savings studies can be performed to enable unattended, remote sensing packages. Image compression and transmission technologies can be incorporated to enable an improved telepresence experience.

Prechtl, Eric F.↗

3-D Volumetric Gamma-ray Imaging and Source Localization with a Mobile Robot - 18124

Radiation detection has largely been a manual inspection process with point sensors such as Geiger-Muller counters and scintillation spectrometers to date. While their observations of source proximity prove useful, they lack the directional information necessary for efficient source localization and characterization in cluttered environments with multiple radiation sources. The recent commercialization of Compton gamma cameras provides directional information to the broader radiation detection community for the first time. This paper presents the integration of a Compton gamma camera with a self-localizing ground robot for accurate 3D radiation mapping. Using the position and orientation of the robot, radiation images from the gamma camera are accumulated over a traversed path in a shared frame of reference to construct a consistent voxel grid-based radiation map. The peaks of the map at pre-specified energy windows are selected as the source location estimates, which are compared to the ground truth source locations. The proposed approach localizes multiple sources to within an average of 0.2 m in two 5 x 4 m{sup 2} and 14 x 6 m{sup 2} laboratory environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LCLS-S1 optical transition radiation monitor.

Argonne National Laboratory has developed a high- resolution optical transition radiation (OTR) imaging monitor for the Linac Coherent Light Source (LCLS) injection linac at SLAC. The imaging station,OTR-S1, will be located at the S1 spectrometer with a beam energy of 135 MeV. The system will be used to acquire 2-D transverse beam distributions of the accelerated photocathode-gun-generated electron beam. We anticipate an average beam current of 0.2 to 1 nC and nominal beam spot size of 130 mum (sigmax), 100 mum (sigmay). The imaging system was designed for a field of view x/y: 10 times 7.5 mm. The spatial resolution of {approx}12 microns was verified over the central 5times4 mm region in the visible. A 12-bit digital camera acquires the image and a Mac-based digital frame-capturing system was employed for the initial lab-based performance testing of the device. We report on system development, testing methods, and data analysis.

43 PARTICLE ACCELERATORS↗

Video Based Sensor for Tracking 3-Dimensional Targets

Video-Based Sensor for Tracking 3-Dimensional Targets The National Aeronautics and Space Administration's (NASAs) Marshall Space Flight Center (MSFC) has been developing and testing video-based sensors for automated spacecraft guidance for several years, and the next generation of video sensor will have tracking rates up to 100 Hz and will be able to track multiple reflectors and targets. The Video Guidance Sensor (VGS) developed over the past several years has performed well in testing and met the objective of being used as the terminal guidance sensor for an automated rendezvous and capture system. The first VGS was successfully tested in closed-loop 3-degree-of-freedom (3- DOF) tests in 1989 and then in 6-DOF open-loop tests in 1992 and closed-loop tests in 1993-4. Development and testing continued, and in 1995 approval was given to test the VGS in an experiment on the Space Shuttle. The VGS flew in 1997 and in 1998, performing well for both flights. During the development and testing before, during, and after the flight experiments, numerous areas for improvement were found. The VGS was developed with a sensor head and an electronics box, connected by cables. The VGS was used in conjunction with a target that had wavelength-filtered retro-reflectors in a specific pattern, The sensor head contained the laser diodes, video camera, and heaters and coolers. The electronics box contained a frame grabber, image processor, the electronics to control the components in the sensor head, the communications electronics, and the power supply. The system works by sequentially firing two different wavelengths of laser diodes at the target and processing the two images. Since the target only reflects one wavelength, it shows up well in one image and not at all in the other. Because the target's dimensions are known, the relative positions and attitudes of the target and the sensor can be computed from the spots reflected from the target. The system was designed to work from I meter out to I 10 meters. The VGS was mounted on the Space Shuttle while its target was mounted on the Spartan free-flyer carried on the same Shuttle flight. The VGS tracked the Spartan at ranges up to 170m, and the VGS range data very closely matched the range data from the Hand-Held Laser- Rangefinder used by the astronauts on board the Shuttle. While the VGS was designed primarily as a terminal guidance sensor for an automated spacecraft, it could be applied to other uses. It could be used as an alignment aid for an operator of a remote system (giving position and attitude feedback data, as well as a camera view of the target), as a feedback system for a robotic arm, or for automated vehicle guidance. The next generation VGS, with its higher tracking rates, smaller size, and lower power could be used in more places than the original VGS, and by using LED's instead of laser diodes, the system would be eye-safe at any range. Other possible uses include tracking 3-dimensional objects with retro-reflectors mounted at various locations or motion analysis by placing several retro-reflectors on the moving object and tracking them at high speeds. There are few sensors capable of performing tasks similar to those the VGS can perform, and the next generation VGS will be even more capable than the original. Some of this work is previously presented in the papers.

Howard, R. T.↗

Observation of alloy solidification using high-speed video

A high-speed video instrumentation system was used to observe solidification of undercooled Ti-51 at. pct Al. The camera system developed by Battelle is capable of operation at rates up to 12,000 frames per second. The system digitizes and stores video images acquired by a 64 x 64 pixel silicon photodiode array. In a joint effort with Vanderbilt University the camera was used to observe three transformations of the undercooled alloys, using containerless processing by electromagnetic levitation. The first was solidification where nucleation was induced at an undercooling of 9 percent Tl, where Tl is the liquidus temperature of the alloy, and the second was solidification where nucleation was spontaneous at an undercooling of 15 percent Tl. The third event was a solid-state nucleation and growth transformation following the solidification at an undercooling of 15 percent Tl.

Bassler, B. T.↗

Physical Properties of Sub-galactic Clumps at 0.5 ≤ Z ≤ 1.5 in the UVUDF

We present an investigation of clumpy galaxies in the Hubble Ultra Deep Field at 0.5⩽z⩽1.5 in the rest-frame far-ultraviolet (FUV) using Hubble Space Telescope Wide Field Camera 3 broadband imaging in F225W, F275W, and F336W. An analysis of 1404 galaxies yields 209 galaxies that host 403 kpc scale clumps. These host galaxies appear to be typical star-forming galaxies, with an average of 2 clumps per galaxy and reaching a maximum of 8 clumps. We measure the photometry of the clumps and determine the mass, age, and star formation rates (SFR) using the spectral energy distribution fitting code FAST. We find that clumps make an average contribution of 19% to the total rest-frame FUV flux of their host galaxy. Individually, clumps contribute a median of 5% to the host galaxy SFR and an average of ∼4% to the host galaxy mass, with total clump contributions to the host galaxy stellar mass ranging widely from lower than 1% up to 93%. Clumps in the outskirts of galaxies are typically younger, with higher SFRs, than clumps in the inner regions. The results are consistent with clump migration theories in which clumps form through violent gravitational instabilities in gas-rich turbulent disks, eventually migrate toward the center of the galaxies, and coalesce into the bulge.

79 ASTRONOMY AND ASTROPHYSICS↗

Video Mosaicking for Inspection of Gas Pipelines

A vision system that includes a specially designed video camera and an image-data-processing computer is under development as a prototype of robotic systems for visual inspection of the interior surfaces of pipes and especially of gas pipelines. The system is capable of providing both forward views and mosaicked radial views that can be displayed in real time or after inspection. To avoid the complexities associated with moving parts and to provide simultaneous forward and radial views, the video camera is equipped with a wide-angle (>165 ) fish-eye lens aimed along the axis of a pipe to be inspected. Nine white-light-emitting diodes (LEDs) placed just outside the field of view of the lens (see Figure 1) provide ample diffuse illumination for a high-contrast image of the interior pipe wall. The video camera contains a 2/3-in. (1.7-cm) charge-coupled-device (CCD) photodetector array and functions according to the National Television Standards Committee (NTSC) standard. The video output of the camera is sent to an off-the-shelf video capture board (frame grabber) by use of a peripheral component interconnect (PCI) interface in the computer, which is of the 400-MHz, Pentium II (or equivalent) class. Prior video-mosaicking techniques are applicable to narrow-field-of-view (low-distortion) images of evenly illuminated, relatively flat surfaces viewed along approximately perpendicular lines by cameras that do not rotate and that move approximately parallel to the viewed surfaces. One such technique for real-time creation of mosaic images of the ocean floor involves the use of visual correspondences based on area correlation, during both the acquisition of separate images of adjacent areas and the consolidation (equivalently, integration) of the separate images into a mosaic image, in order to insure that there are no gaps in the mosaic image. The data-processing technique used for mosaicking in the present system also involves area correlation, but with several notable differences: Because the wide-angle lens introduces considerable distortion, the image data must be processed to effectively unwarp the images (see Figure 2). The computer executes special software that includes an unwarping algorithm that takes explicit account of the cylindrical pipe geometry. To reduce the processing time needed for unwarping, parameters of the geometric mapping between the circular view of a fisheye lens and pipe wall are determined in advance from calibration images and compiled into an electronic lookup table. The software incorporates the assumption that the optical axis of the camera is parallel (rather than perpendicular) to the direction of motion of the camera. The software also compensates for the decrease in illumination with distance from the ring of LEDs.

Magruder, Darby↗

Physical Properties of Sub-Galactic Clumps at 0.5 ≤ Z ≤ 1.5 in the UVUDF

We present an investigation of clumpy galaxies in the Hubble Ultra Deep Field at 0.5 equal to or less than z equal to or less than 1.5 in the rest-frame far-ultraviolet (FUV) using Hubble Space Telescope Wide Field Camera 3 broadband imaging in F225W, F275W, and F336W. An analysis of 1404 galaxies yields 209 galaxies that host 403 kpc scale clumps. These host galaxies appear to be typical star-forming galaxies, with an average of 2 clumps per galaxy and reaching a maximum of 8 clumps. We measure the photometry of the clumps and determine the mass, age, and star formation rates (SFR) using the spectral energy distribution fitting code FAST (Fitting and Assessment of Synthetic Templates). We find that clumps make an average contribution of 19% to the total rest-frame FUV flux of their host galaxy. Individually, clumps contribute a median of 5% to the host galaxy SFR and an average of approximately 4% to the host galaxy mass, with total clump contributions to the host galaxy stellar mass ranging widely from lower than 1% up to 93%. Clumps in the outskirts of galaxies are typically younger, with higher SFRs, than clumps in the inner regions. The results are consistent with clump migration theories in which clumps form through violent gravitational instabilities in gas-rich turbulent disks, eventually migrate toward the center of the galaxies, and coalesce into the bulge.

galaxies: structure↗

Sonoluminescence Bubble Measurements using Vision-Based Algorithms

Vision-based measurement methods were used to measure bubble sizes in this sonoluminescence experiment. Bubble imaging was accomplished by placing the bubble between a bright light source and a microscope-CCD camera system. A collimated light-emitting diode was operated in a pulsed model with an adjustable time delay with respect to the piezo-electric transducer drive signal. The light-emitting diode produced a bubble shadowgraph consisting of a multiple exposure made by numerous light pulses imaged onto a charge-couple device camera. Each image was transferred from the camera to a computer-controlled machine vision system via a frame grabber. The frame grabber was equipped with on-board memory to accomodate sequential image buffering while images were transferred to the host processor and analyzed. This configuration allowed the host computer to perform diameter measurements, centroid position measurements and shape estimation in "real-time" as the next image was being acquired. Bubble size measurement accuracy with an uncertainty of 3 microns was achieved using standard lenses and machine vision algorithms. Bubble centroid position accuracy was also within the 3 micron tolerance of the vision system. This uncertainty estimation accounted for the optical spatial resolution, digitization errors and the edge detection algorithm accuracy. The vision algorithms include camera calibration, thresholding, edge detection, edge position determination, distance between two edges computations and centroid position computations.

Hall, Nancy R.↗

A study of solid particle flow characterization in solar particle receiver

The solid particle receiver (SPR) is a direct absorption receiver in which solar energy heats a curtain of falling ceramic particle to a temperature in excess of 1000 C. A small scale test platform was built to investigate particle flow properties. The curtain was comprised of approximately 697 {mu}m ceramic particles that were dropped within the receiver cavity of the test platform. Tests were conducted to experimentally determine the distribution of particles velocity, curtain thickness, and curtain opacity along a drop length of approximately 3 m. Velocity data were measured using a high speed digital camera to obtain images of the particle flow at 1000 frames per second with an exposure time of 100 {mu}s. Five mass flow rates ranging from 1 kg/s-m to 22 kg/s-m were examined, and it was found that all flows approached a terminal velocity of about 6-7 m/s in a vertical drop distance of 3 m. The experimental results were validated with computational results and were found in excellent agreement with the simulation results. In addition, a similar study was performed with various sizes of the particles to better understand how the particle flow characteristics were affected by the size of the particles. (author)

14 SOLAR ENERGY↗

Time-Resolved Imaging Of Transient Plasma

Pulsed capillary discharge is a compact device that is used to perform fast electrical discharge that is used to produce transient plasma. In this work, a more economical imaging technique is developed in order to study the dynamics of the plasma that is formed in a capillary tube. The imaging system consists of two main devices, a four-frame gated micro-channel plate and a Nikon Coolpix5000 camera. The time-resolved imaging that we have performed in order to study the dynamics of the plasma that is formed in a 10 mm long and 1 mm diameter low pressure capillary tube is reported. The images obtained portrayed that the plasma is heated up when the magnitude of the current is around the maximum and cools down when the current magnitude is around the minimum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved imaging of electrical discharge development in underwater bubbles

The formation and development of plasma in single air bubbles submerged in water were investigated. The difference in the discharge dynamics and the after-effects on the bubble were investigated using a 900 000 frame per second high-speed charge-coupled device camera. It was observed that depending on the position of the electrodes, the breakdown could be categorized into two modes: (1) direct discharge mode, where the high voltage and ground electrodes were in contact with the bubble, and the streamer would follow the shortest path and propagate along the axis of the bubble and (2) dielectric barrier mode, where the ground electrode was not in touch with the bubble surface, and the streamer would form along the inner surface of the bubble. The oscillation of the bubble and the development of instabilities on the bubble surface were also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of a 512 x 512 Gated CMOS Imager with a 250 ps Exposure Time

We describe the performance of a 512x512 gated CMOS read out integrated circuit (ROIC) with a 250 ps exposure time. A low-skew, H-tree trigger distribution system is used to locally generate individual pixel gates in each 8x8 neighborhood of the ROIC. The temporal width of the gate is voltage controlled and user selectable via a precision potentiometer. The gating implementation was first validated in optical tests of a 64x64 pixel prototype ROIC developed as a proof-of-concept during the early phases of the development program. The layout of the H-Tree addresses each quadrant of the ROIC independently and admits operation of the ROIC in two modes. If “common mode” triggering is used, the camera provides a single 512x512 image. If independent triggers are used, the camera can provide up to four 256x256 images with a frame separation set by the trigger intervals. The ROIC design includes small (sub-pixel) optical photodiode structures to allow test and characterization of the ROIC using optical sources prior to bump bonding. Reported test results were obtained using short pulse, second harmonic Ti:Sapphire laser systems operating at λ~ 400 nm at sub-ps pulse widths.

47 OTHER INSTRUMENTATION↗

Interaction of an Optical Discharge with a Shock Wave

The results of an experimental study of the impact of the focused pulsed-periodic radiation from a CO{sub 2} laser on a gas-dynamic structure in a supersonic jet are presented. The radiation of the CO{sub 2} laser is propagated across the stream and focused by a lens on the axis of the supersonic jet. To register the flow structure, a shadow scheme with a slit and a flat knife located along the flow is used. The image is fixed by a speed camera with an exposure time of 1.5 μs and a frame rate of 1000 1/s. In the flow, the plasma initiated by the pulsedperiodic laser is visualized in order to identify and determine the period of plasma development, as well as the motion of the initial front of the shock wave. It is shown that at the transverse input of laser radiation into the stream the periodic structure of the thermal trace is created with the formation of an unsteady shock wave from the energy release zone. At small repetition rates of laser radiation pulses, the thermal spot interacts with the flow in the pulsed mode. It is shown that elliptic nonstationary shock waves are formed only at low subsonic flow velocities and in a stationary atmosphere. The process of nonstationary ignition by an optical discharge of a methane–air mixture during a subsonic outflow into a motionless atmosphere is shown experimentally. The results of optical visualization indicate burning in the trace behind the optical discharge region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Taylor Gun Impact Tests on Mock Comp-B Specimens

Twelve (12) Mock Comp-B specimens were received from Sandia National Laboratories in Albuquerque. Specimens were approximately 76.3 mm long and 15.8 mm in diameter. Weights varied from 21.23 to 22.14 grams, and various pieces had visible, mm-sized holes or gaps due to fabrication. Hand-marked lines, 1-centimeter down the length, were used in image analysis. Specimens were fired out of the Taylor gas gun and impacted on a brass anvil. High-speed images (25 μs per frame) were taken of the specimen during impact, with the camera 1) viewing through a boom box side port or 2) viewing from the top/front of the anvil through a Lexan window on the boom box. Side views are useful because they show silhouette contours of the specimen collapse. Top view images are useful because they show more clearly the time and strain at which fracture and fragmentation begins. We tested 4 specimen velocities: 133.5, 115.3, 87.8 and 74.5 m/s. At each velocity, at least one specimen was viewed from the side and one viewed from the top.

36 MATERIALS SCIENCE↗

Photoballistics of volcanic jet activity at Stromboli, Italy

Two night eruptions of the volcano Stromboli were studied through 70-mm photography. Single-camera techniques were used. Particle sphericity, constant velocity in the frame, and radial symmetry were assumed. Properties of the particulate phase found through analysis include: particle size, velocity, total number of particles ejected, angular dispersion and distribution in the jet, time variation of particle size and apparent velocity distribution, averaged volume flux, and kinetic energy carried by the condensed phase. The frequency distributions of particle size and apparent velocities are found to be approximately log normal. The properties of the gas phase were inferred from the fact that it was the transporting medium for the condensed phase. Gas velocity and time variation, volume flux of gas, dynamic pressure, mass erupted, and density were estimated. A CO2-H2O mixture is possible for the observed eruptions. The flow was subsonic. Velocity variations may be explained by an organ pipe resonance. Particle collimation may be produced by a Magnus effect.

Chouet, B.↗

Soft X-ray and XUV imaging with a charge-coupled device /CCD/-based detector

A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.

Loter, N. G.↗