Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Status of the WPEC subgroup 46 - Efficient and effective use of integral experiments for nuclear data validation

The present paper summarizes the current status of the activities of the on-going WPEC subgroup 46 which was the last significant initiative of Massimo before he passed away. The goal of WPEC/SG46 is to define, test and document a methodology to provide unambiguous feedback to the nuclear data evaluator community, based on the joint use of integral experiments and data assimilation techniques. Part of this effort resulted in a renewed analysis of the original Target Accuracy Requirement (TAR) exercise of WPEC/SG26, by adding more diverse nuclear systems and parameters, including reaction channels correlations and a coarser energy group structure; and making use of the progress made in the most recent evaluations in terms of both nuclear data and covariance matrices. The preliminary outcomes of the updated TAR exercise, documented by various groups worldwide are clear already: uncertainty reductions are required for many nuclide-reaction pairs in a variety of energy range if the target uncertainty requirements set by the industry are to be met, especially for k{sub eff}. The inclusion of correlations between the various reaction channels had a major impact on the magnitude of the required uncertainty reduction. Those uncertainty reductions are unlikely to be met by differential measurements alone. However, the selection of relevant integral experiment and a subsequent adjustment procedure may help meet these requirements. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Current Status of the DOE/NNSA Nuclear Criticality Safety Program Hands-on Criticality Safety Training Courses

In 2011, the US Department of Energy/National Nuclear Security Administration (DOE/NNSA) Nuclear Criticality Safety Program (NCSP) developed and piloted a 2-week nuclear criticality safety (NCS) practitioner course to support training and qualification of new NCS staff. The course was developed in accordance with the American National Standard Institute/American Nuclear Society (ANSI/ANS) standard for NCS training and qualifications (ANSI/ANS-8.26-2007). In 2013, an NCS manager’s course was developed for process supervisors, managers, regulators, and other professionals with NCS-related responsibilities. These courses consist of classroom education, facility training, and hands-on subcritical and critical experiments training. Each course is currently offered twice per year. The 2-week practitioner course offers a week of classroom training, with practical workshops and exercises focused on teaching students how to perform an NCS evaluation. The second week of training involves hands-on critical and subcritical experiments and measurements. The first week is offered in Las Vegas, Nevada, at the DOE Nevada Field Office or the National Atomic Testing Museum. Depending on the student’s clearance level, the second week is offered at Sandia National Laboratory (SNL) (uncleared and L-cleared students) or at the National Criticality Experiments Research Center (NCERC) (Q-cleared students). The 1-week manager’s course is offered at SNL or NCERC, depending on clearance or interest, and includes classroom and hands-on critical and subcritical experiments and measurements. This paper provides an overview and status report for the DOE/NNSA NCSP training courses in NCS and provides information about future course offerings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Relationship of Walking Intensity to Total and Cause-Specific Mortality. Results from the National Walkers’ Health Study

Purpose: Test whether: 1) walking intensity predicts mortality when adjusted for walking energy expenditure, and 2) slow walking pace (≥24-minute mile) identifies subjects at substantially elevated risk for mortality. Methods: Hazard ratios from Cox proportional survival analyses of all-cause and cause-specific mortality vs. usual walking pace (min/mile) in 7,374 male and 31,607 female recreational walkers. Survival times were left censored for age at entry into the study. Other causes of death were treated as a competing risk for the analyses of cause-specific mortality. All analyses were adjusted for sex, education, baseline smoking, prior heart attack, aspirin use, diet, BMI, and walking energy expenditure. Deaths within one year of baseline were excluded. Results: The National Death Index identified 1968 deaths during the average 9.4-year mortality surveillance. Each additional minute per mile in walking pace was associated with an increased risk of mortality due to all causes (1.8% increase, P=10-5), cardiovascular diseases (2.4% increase, P=0.001, 637 deaths), ischemic heart disease (2.8% increase, P=0.003, 336 deaths), heart failure (6.5% increase, P=0.001, 36 deaths), hypertensive heart disease (6.2% increase, P=0.01, 31 deaths), diabetes (6.3% increase, P=0.004, 32 deaths), and dementia (6.6% increase, P=0.0004, 44 deaths). Those reporting a pace slower than a 24-minute mile were at increased risk for mortality due to all-causes (44.3% increased risk, P=0.0001), cardiovascular diseases (43.9% increased risk, P=0.03), and dementia (5.0-fold increased risk, P=0.0002) even though they satisfied the current exercise recommendations by walking ≥7.5 metabolic equivalent (MET)-hours per week. Conclusions: The risk for mortality: 1) decreases in association with walking intensity, and 2) increases substantially in association for walking pace ≥24 minute mile (equivalent to <400m during a six-minute walk test) even among subjects who exercise regularly.

59 BASIC BIOLOGICAL SCIENCES↗

Platelet cloaking of circulating tumour cells in patients with metastatic prostate cancer: Results from ExPeCT, a randomised controlled trial

Background: Circulating tumour cells (CTCs) represent a morphologically distinct subset of cancer cells, which aid the metastatic spread. The ExPeCT trial aimed to examine the effectiveness of a structured exercise programme in modulating levels of CTCs and platelet cloaking in patients with metastatic prostate cancer. Methods: Participants (n = 61) were randomised into either standard care (control) or exercise arms. Whole blood was collected for all participants at baseline (T0), three months (T3) and six months (T6), and analysed for the presence of CTCs, CTC clusters and platelet cloaking. CTC data was correlated with clinico-pathological information. Results: Changes in CTC number were observed within group over time, however no significant difference in CTC number was observed between groups over time. Platelet cloaking was identified in 29.5% of participants. A positive correlation between CTC number and white cell count (WCC) was observed (p = 0.0001), in addition to a positive relationship between CTC clusters and PSA levels (p = 0.0393). Conclusion: The presence of platelet cloaking has been observed in this patient population for the first time, in addition to a significant correlation between CTC number and WCC. Trial registration: ClincalTrials.gov identifier NCT02453139 .

60 APPLIED LIFE SCIENCES↗

Maximizing Strength: The Stimuli and Mediators of Strength Gains and Their Application to Training and Rehabilitation

Abstract Spiering, BA, Clark, BC, Schoenfeld, BJ, Foulis, SA, and Pasiakos, SM. Maximizing strength: the stimuli and mediators of strength gains and their application to training and rehabilitation. J Strength Cond Res 37(4): 919–929, 2023—Traditional heavy resistance exercise (RE) training increases maximal strength, a valuable adaptation in many situations. That stated, some populations seek new opportunities for pushing the upper limits of strength gains (e.g., athletes and military personnel). Alternatively, other populations strive to increase or maintain strength but cannot perform heavy RE (e.g., during at-home exercise, during deployment, or after injury or illness). Therefore, the purpose of this narrative review is to (a) identify the known stimuli that trigger gains in strength; (b) identify the known factors that mediate the long-term effectiveness of these stimuli; (c) discuss (and in some cases, speculate on) potential opportunities for maximizing strength gains beyond current limits; and (d) discuss practical applications for increasing or maintaining strength when traditional heavy RE cannot be performed. First, by conceptually deconstructing traditional heavy RE, we identify that strength gains are stimulated through a sequence of events, namely: giving maximal mental effort, leading to maximal neural activation of muscle to produce forceful contractions, involving lifting and lowering movements, training through a full range of motion, and (potentially) inducing muscular metabolic stress. Second, we identify factors that mediate the long-term effectiveness of these RE stimuli, namely: optimizing the dose of RE within a session, beginning each set of RE in a minimally fatigued state, optimizing recovery between training sessions, and (potentially) periodizing the training stimulus over time. Equipped with these insights, we identify potential opportunities for further maximizing strength gains. Finally, we identify opportunities for increasing or maintaining strength when traditional heavy RE cannot be performed.

Sport Sciences↗

IBRD Operational Decision Framework

The IBRD Operational Decision Framework in this document is an expansion of an emerging general risk management framework under development by an interagency working group. It provides the level of detail necessary to develop a general Consequence Management Guidance Document for biological contamination remediation and restoration. It is the intent of this document to support both wide area and individual site remediation and restoration activities. This product was initiated as a portion of the IBRD Task 1 Systems Analysis to aid in identification of wide area remediation and restoration shortcomings and gaps. The draft interagency general risk management framework was used as the basis for the analysis. The initial Task 1 analysis document expanded the draft interagency framework to a higher level of resolution, building on both the logic structure and the accompanying text explanations. It was then employed in a qualitative manner to identify responsible agencies, data requirements, tool requirements, and current capabilities for each decision and task. This resulted in identifying shortcomings and gaps needing resolution. Several meetings of a joint LLNL/SNL working group reviewed and approved the initial content of this analysis. At the conclusion of Task 1, work continued on the expanded framework to generate this Operational Decision Framework which is consistent with the existing interagency general risk management framework. A large LLNL task group met repeatedly over a three-month period to develop the expanded framework, coordinate the framework with the biological remediation checklist, and synchronize the logic with the Consequence Management Plan table of contents. The expanded framework was briefed at a large table top exercise reviewing the interagency risk management framework. This exercise had representation from major US metropolitan areas as well as national agencies. This product received positive comments from the participants. Upon completion of the Operational Decision Framework, another joint LLNL/SNL working group conducted a day-long review. Identified modifications were made to the document, resulting in the included product.

99 GENERAL AND MISCELLANEOUS↗

DYNA3D/ParaDyn Regression Test Suite Inventory

The following table constitutes an initial assessment of feature coverage across the regression test suite used for DYNA3D and ParaDyn. It documents the regression test suite at the time of production release 10.1 in September 2010. The columns of the table represent groupings of functionalities, e.g., material models. Each problem in the test suite is represented by a row in the table. All features exercised by the problem are denoted by a check mark in the corresponding column. The definition of ''feature'' has not been subdivided to its smallest unit of user input, e.g., algorithmic parameters specific to a particular type of contact surface. This represents a judgment to provide code developers and users a reasonable impression of feature coverage without expanding the width of the table by several multiples. All regression testing is run in parallel, typically with eight processors. Many are strictly regression tests acting as a check that the codes continue to produce adequately repeatable results as development unfolds, compilers change and platforms are replaced. A subset of the tests represents true verification problems that have been checked against analytical or other benchmark solutions. Users are welcomed to submit documented problems for inclusion in the test suite, especially if they are heavily exercising, and dependent upon, features that are currently underrepresented.

42 ENGINEERING↗

Development of a Low-Cost Rotary Steerable Drilling System

The project had the goal to develop and commercialize a low-cost rotary steerable system (LCRSS) capable of operating downhole at conventional pressures and temperatures to reduce operating costs by a minimum of 50% and lost-in-hole charges by at least 50% over the currently offered systems. The LCRSS system developed under this project does reduce operating costs by 55% and lost-in-hole charges by at least 50%. The developed product is not commercializable in its current form. The overall objective was to develop and commercialize a low cost rotary steerable system (LCRSS) capable of operating downhole at conventional pressures and temperatures (20,000 psi/150 C) while reducing the operating costs by 50% and the lost-in-hole charges by 50% over the currently available systems. The proposed reduction in costs were to be realized through the significant reduction in tool complexity, a corresponding increase in tool reliability as expressed in the mean-time between failure (MTBF), and a reduction in the time and costs required to service tools after each field operation. Ultimately, the LCRSS system was to be capable of drilling 7 7/8 in. to 9 5/8 in. borehole diameters. The project was divided into three Phases, of which Phases I & II were previously completed and reported on, and are part of the case file. Therefore, the previously reported information is not repeated herein. Phase III included the fabrication of two field ready prototypes that were to be subjected to a series of drilling tests at GTI Catoosa, DOE RMOTC, and at customer partnering wells, if possible, as appropriate in the timing of the field test objectives to fully exercise all elements of the LCRSS. These tests were conducted in an iterative process based on a performance/reliability improvement cycle with the goal of demonstrating the system met all aspects required for commercial viability. These tests were conducted to achieve continuous runs of 100+ hours with well trajectories that fully exercised the tool's build/turn/drop/hold target capabilities and its higher end ratings for bit weight, torque and rotary speed. The tool teardowns were rigorously analyzed at the conclusion of each field run to assess component wear rates and to fully document any detrimental behavior(s) observed.

15 GEOTHERMAL ENERGY↗

Non-Ideal Behavior in Solvent Extraction

This report presents a summary of the work performed to meet FCR&D level 3 milestone M31SW050801, 'Complete the year-end report summarizing FY11 experimental and modeling activities.' This work was carried out under the auspices of the Non-Ideality in Solvent Extraction Systems FCR&D work package. The report summarizes our initial considerations of potential influences that non-ideal chemistry may impose on computational prediction of outcomes in solvent extraction systems. The report is packaged into three separate test cases where a robustness of the prediction by SXFIT program is under scrutiny. The computational exercises presented here emphasize the importance of accurate representation of both an aqueous and organic mixtures when modeling liquid-liquid distribution systems. Case No.1 demonstrates that non-ideal behavior of HDEHP in aliphatic diluents, such as n-dodecane, interferes with the computation. Cases No.2 and No.3 focus on the chemical complexity of aqueous electrolyte mixtures. Both exercises stress the need for an improved thermodynamic model of an aqueous environment present in the europium distribution experiments. Our efforts for year 2 of this project will focus on the improvements of aqueous and non-aqueous solution models using fundamental physical properties of mixtures acquired experimentally in our laboratories.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

RELAP5-3D Resolution of Known Restart/Backup Issues

The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequential verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results for Phase I of the IAEA Coordinated Research Program on HTGR Uncertainties

The quantification of uncertainties in design and safety analysis of reactors is today not only broadly accepted, but in many cases became the preferred way to replace traditional conservative analysis for safety and licensing analysis. The use of a more fundamental methodology is also consistent with the reliable high fidelity physics models and robust, efficient, and accurate codes available today. To facilitate uncertainty analysis applications a comprehensive approach and methodology must be developed and applied. High Temperature Gas-cooled Reactors (HTGR) has its own peculiarities, coated particle design, large graphite quantities, different materials and high temperatures that also require other simulation requirements. The IAEA has therefore launched a Coordinated Research Project (CRP) on the HTGR Uncertainty Analysis in Modeling (UAM) in 2013 to study uncertainty propagation specifically in the HTGR analysis chain. Two benchmark problems are defined, with the prismatic design represented by the General Atomics (GA) MHTGR-350 and a 250 MW modular pebble bed design similar to the HTR-PM (INET, China). This report summarizes the contributions of the HTGR Methods Simulation group at Idaho National Laboratory (INL) up to this point of the CRP. The activities at INL have been focused so far on creating the problem specifications for the prismatic design, as well as providing reference solutions for the exercises defined for Phase I. An overview is provided of the HTGR UAM objectives and scope, and the detailed specifications for Exercises I-1, I-2, I-3 and I-4 are also included here for completeness. The main focus of the report is the compilation and discussion of reference results for Phase I (i.e. for input parameters at their nominal or best-estimate values), which is defined as the first step of the uncertainty quantification process. These reference results can be used by other CRP participants for comparison with other codes or their own reference results. The status on the Monte Carlo modeling of the experimental VHTRC facility is also discussed. Reference results were obtained for the neutronics stand-alone cases (Ex. I-1 and Ex. I-2) using the (relatively new) Monte Carlo code Serpent, and comparisons were performed with the more established Monte Carlo codes MCNP and KENO-VI. For the thermal-fluids stand-alone cases (Ex. I-3 and I-4) the commercial CFD code CFX was utilized to obtain reference results that can be compared with lower fidelity tools.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measuring Human Performance within Computer Security Incident Response Teams

Human performance has become a pertinent issue within cyber security. However, this research has been stymied by the limited availability of expert cyber security professionals. This is partly attributable to the ongoing workload faced by cyber security professionals, which is compound ed by the limited number of qualified personnel and turnover of personnel across organizations. Additionally, it is difficult to conduct research, and particularly, openly published research, due to the sensitivity inherent to cyber ope rations at most organizations. As an alternative, the current research has focused on data collection during cyber security training exercises. These events draw individuals with a range of knowledge and experience extending from seasoned professionals to recent college graduates to college students. The current paper describes research involving data collection at two separate cyber security exercises. This data collection involved multiple measures which included behavioral performance based on human - machine transactions and questionnaire - based assessments of cyber security experience.

59 BASIC BIOLOGICAL SCIENCES↗

Improving the Sandia Test Protocols with Advanced Inverter Functionality Testing of INV3, VV11, FW21, and L/HVRT

Sandia National Laboratories has created a test protocol for IEC TR 61850-90-7 advanced distributed energy resource (DER) functions, titled "Test Protocols for Advanced Inverter Interoperability Functions," often referred to as the Sandia Test Protocols. This document is currently in draft form, but has been shared with stakeholders around the world with the ultimate goal of collaborating to create a consensus set of test protocols which can be then incorporated into an International Electrotechnical Commission (IEC) and/or Underwriters Laboratories (UL) certification standard. The protocols are designed to ensure functional interoperability of DER (primarily photovoltaic (PV) inverters and energy storage systems) as specified by the IEC technical report through communication and electrical tests. In this report, Sandia exercises the electrical characterization portion of the test protocols for four functions: constant power factor (INV3), volt-var (VV11), frequency-watt (FW21), and Low and High Voltage Ride Through (L/HVRT). The goal of the tests reported here was not to characterize the performance of the equipment under test (EUT), but rather to (a) exercise the draft Sandia Test Protocols in order to identify any revisions needed in test procedures, conditions, or equipment and (b) gain experience with state-of-the-art DER equipment to determine if the tests put unrealistic or overly aggressive requirements on EUT operation. In performing the work according to the current versions of the protocols, Sandia was able to identify weaknesses in the current versions and suggest improvements to the test protocols.

14 SOLAR ENERGY↗

DYNA3D/ParaDyn Regression Test Suite Inventory

The following table constitutes an initial assessment of feature coverage across the regression test suite used for DYNA3D and ParaDyn. It documents the regression test suite at the time of preliminary release 16.1 in September 2016. The columns of the table represent groupings of functionalities, e.g., material models. Each problem in the test suite is represented by a row in the table. All features exercised by the problem are denoted by a check mark (√) in the corresponding column. The definition of “feature” has not been subdivided to its smallest unit of user input, e.g., algorithmic parameters specific to a particular type of contact surface. This represents a judgment to provide code developers and users a reasonable impression of feature coverage without expanding the width of the table by several multiples. All regression testing is run in parallel, typically with eight processors, except problems involving features only available in serial mode. Many are strictly regression tests acting as a check that the codes continue to produce adequately repeatable results as development unfolds; compilers change and platforms are replaced. A subset of the tests represents true verification problems that have been checked against analytical or other benchmark solutions. Users are welcomed to submit documented problems for inclusion in the test suite, especially if they are heavily exercising, and dependent upon, features that are currently underrepresented.

97 MATHEMATICS AND COMPUTING↗

Requirements Document for Development of a Livermore Tomography Tools Interface

In this document, we outline an exercise performed at LLNL to evaluate the user interface deficits of a LLNL-developed CT reconstruction software package, Livermore Tomography Tools (LTT). We observe that a difficult-to-use command line interface and the lack of support functions compound to generate a bottleneck in the CT reconstruction process when input parameters to key functions are not well known. Through the exercise of systems engineering best practices, we generate key performance parameters for a LTT interface refresh, and specify a combination of back-end (“test-mode” functions) and front-end (graphical user interface visualization and command scripting tools) solutions to LTT’s poor user interface that aim to mitigate issues and lower costs associated with CT reconstruction using LTT. Key functional and non-functional requirements and risk mitigation strategies for the solution are outlined and discussed.

42 ENGINEERING↗

Technical Submission Form: Technical Specification of a Wave Energy Farm.

The Wave - SPARC project developed the Technology Performance Level (TPL) assessment procedure based on a rigorous Systems Engineering exercise. The TPL assessment allows a whole system evaluation of Wave Energy Conversion Technology by measuring it against the requirements determined through the Systems Engineering exercise. The TPL assessment is intended to be useful in technology evaluation; in technology innovation; in allocation of public or priva te investment, and; in making equipment purchasing decisions. This Technical Submission Form (TSF) serves the purpose of collecting relevant and complete information, in a technology agnostic way, to allow TPL assessment s to be made by third party assessor s. The intended usage of this document is that the organization or people that are performing the role of developers or promoters of a particular technology will use this form to provide the information necessary for the organization or people who are perf orming the assessor role to use the TPL assessment.

16 TIDAL AND WAVE POWER↗

R-Matrix Codes for Charged-Particle Induced Reactions in the Resolved Resonance Region (3), Summary Report of an IAEA Consultants' Meeting IAEA Headquarters, Vienna, Austria, 28-30 June 2017

A Consultants Meeting was held at the IAEA Headquarters, from 28 to 30 June 2017, to discuss the results of a test exercise that had been defined and assigned to all participants of the previous meeting held in December 2016. Five codes were used in this exercise: AMUR, AZURE2, RAC, SFRESCO and SAMMY. The results obtained from these codes were compared and further actions were proposed. Participants’ presentations and technical discussions, as well as proposed additional actions have been summarized in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary of Observations from the 2017 Federal Radiological Monitoring and Assessment Center (FRMAC) Laboratory Analysis Training and Capstone Event

On August 15th thru 17th, 2017 the Federal Radiological Monitoring and Assessment Center (FRMAC) Laboratory Analysis division, the FRMAC Fly Away Laboratory (FAL), the FRMAC Assessment division, and the Mobile Environmental Response Laboratory (MERL) held a training and capstone event for staff from the Environmental Protection Agency (EPA), Remote Sensing Laboratory (RSL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). LAB-100, "Sample Control Training", LAB-200 "QA Specialist Training", and LAB-300 "Laboratory Analysis Manager Training" was given the first two days of the event. The purpose of the training and capstone event was to meet training requirements for billeted FRMAC Lab Analysis staff from RSL, LLNL, and SNL as well as raise awareness of the FRMAC Lab Analysis process with EPA staff as part of a Federal Emergency Management Agency — Nuclear Incident Response Team (FEMA-NIRT) laboratory standardization project. An objective of the standardization project was to help improve the transition of operations from DOE to EPA during a response. To do this effectively, detailed knowledge of the FRMAC Lab Analysis process by the EPA is needed. This training provided a good opportunity for this knowledge transfer. A capstone was held after the two-day training event to allow participants to practice the skills they learned in a realistic scenario. A scenario that was previously developed for a quarterly Consequence Management drill (i.e. Dark Phoenix) was used as the basis for the capstone, with laboratory analysis focused injects used to drive the exercise play. Each position within the FRMAC Lab Analysis Division exercised to specific objectives and helped to uncover gaps in the established processes. The lessons learned during this capstone are broken out in the following categories: Sample Control, In-Situ Gamma Spectroscopy, Analysis Request Forms (ARF), Shipping, QA/QC, Fly Away Laboratory (FAL), and Management.

54 ENVIRONMENTAL SCIENCES↗