Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Environmental Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Seasonal Variation of Total Mercury Burden in the American Alligator (Alligator Mississippiensis) at Merritt Island National Wildlife Refuge (MINWR), Florida

Seasonal variation of mercury (Hg) is not well studied in free-ranging wildlife. Atmospheric deposition patterns of Hg have been studied in detail and have been modeled for both global and specific locations with great accuracy and correlates to environment impact. However, monitoring these trends in wildlife is complicated due to local environmental parameters (e.g., rainfall, humidity, pH, bacterial composition) that can affect the transformation of atmospheric Hg to the biologically available forms. Here, we utilized an abundant and healthy population of American alligators (Alligator mississippiensis) at Merritt Island National Wildlife Refuge (MINWR), FL, and assessed Hg burden in whole blood samples over a span of 7 years (2007 2014; n 174) in an effort to assess seasonal variation of total [Hg]. While the majority of this population is assumed healthy, 18 individuals with low body mass indices (BMI, defined in this study) were captured throughout the 7 year sampling period. These individual alligators exhibited [Hg] that were not consistent with the observed overall seasonal [Hg] variation, and were statistically different from the healthy population of alligators. The alligators with low BMI had elevated concentrations of Hg compared to their age/sex/season matched counterparts with normal BMI. Statistically significant differences were found between the winter and spring seasons for animals with normal BMI. The data in this report supports the conclusion that organismal total [Hg] do fluctuate directly with seasonal deposition rates as well as other seasonal environmental parameters, such as average rainfall and prevailing wind direction. This study highlights the unique environment of MINWR to permit annual assessment of apex predators, such as the American alligator, to determine detailed environmental impact of contaminants of concern.

Hg↗

CARETS: A prototype regional environmental information system. Volume 6: Cost, accuracy and consistency comparisons of land use maps made from high-altitude aircraft photography and ERTS imagery

Accuracy analyses for the land use maps of the Central Atlantic Regional Ecological Test Site were performed for a 1-percent sample of the area. Researchers compared Level II land use maps produced at three scales, 1:24,000, 1:100,000, and 1:250,000 from high-altitude photography, with each other and with point data obtained in the field. They employed the same procedures to determine the accuracy of the Level I land use maps produced at 1:250,000 from high-altitude photography and color composite ERTS imagery. The accuracy of the Level II maps was 84.9 percent at 1:24,000, 77.4 percent at 1:100,000, and 73.0 percent at 1:250,000. The accuracy of the Level I 1:250,000 maps produced from high-altitude aircraft photography was 76.5 percent and for those produced from ERTS imagery was 69.5 percent. The cost of Level II land use mapping at 1:24,000 was found to be high ($11.93 per km 2 ). The cost of mapping at 1:100,000 ($1.75) was about 2 times as expensive as mapping at 1:250,000 ($.88), and the accuracy increased by only 4.4 percent. Level I land use maps, when mapped from high-altitude photography, were about 4 times as expensive as the maps produced from ERTS imagery, although the accuracy is 7.0 percent greater. The Level I land use category that is least accurately mapped from ERTS imagery is urban and built-up land in the non-urban areas; in the urbanized areas, built-up land is more reliably map

Accuracy↗

Global measurements of gaseous and aerosol trace species in the upper troposphere and lower stratosphere from daily flights of 747 airliners

A description is given of the NASA Global Atmospheric Sampling Program (GASP), taking into account the onboard system which collects atmospheric data automatically, the extensive atmospheric measurement capability, and the data handling and distribution procedure. GASP was implemented to assess the environmental impact of aircraft exhaust emissions in the upper troposphere and lower stratosphere. Global air quality data are to be obtained for a period of five to ten years. Measurements of pollutants not related to aircraft exhaust emissions, such as chlorofluoromethanes, are now included. GASP systems are operating on a United Airlines 747, two Pan Am 747s, and a Qantas Airways of Australia 747. Real-time, in-situ measurements are conducted of ozone, water vapor, carbon monoxide, and oxides of nitrogen. Chlorofluoromethanes are measured by laboratory analysis. Typical GASP data show significant changes in ozone, carbon monoxide, and water vapor related to crossings of the tropopause.

Perkins, P. J.↗

Research and technology developments in aeronautics, atmospheric and oceanographic measurements, radar applications, and remote sensing of insects using radar

Highlights of the year's activities and accomplishments are reported in the areas of aircraft safety, scientific ballooning, mid-air payload retrieval, and the design of a microwave power reception and conversion system for on use on a high altitude powered platform. The development and application of an agro-environmental system to provide crop management advisory information to Virginia farmers, and the radar tracking of insects are described. Aircraft systems, developed for measuring atmospheric ozone and nitric acid were used to sample emissions from Mount St. Helens. Investigations of the reliability and precision of the U.S. standard meteorological rocketsonde, applications of the microwave altimeter and airborne lidar system in oceanography, and the development of a multibeam altimeter concept are also summarized.

Oberholtzer, J. D.↗

Microbial mats in playa lakes and other saline habitats: Early Mars analog?

Microbial mats are cohesive benthic microbial communities which inhabit various Terra (Earth-based) environments including the marine littoral and both permanent and ephemeral (playa) saline lakes. Certain geomorphological features of Mars, such as the Margaritifer Sinus, were interpreted as ancient, dried playa lakes, presumably formed before or during the transition to the present Mars climate. Studies of modern Terran examples suggest that microbial mats on early Mars would have had the capacity to survive and propagate under environmental constraints that would have included irregularly fluctuating regimes of water activity and high ultraviolet flux. Assuming that such microbial communities did indeed inhabit early Mars, their detection during the Mars Rover Sample Return (MRSR) mission depends upon the presence of features diagnostic of the prior existence of these communities or their component microbes or, as an aid to choosing suitable landing, local exploration or sampling sites, geomorphological, sedimentological or chemical features characteristic of their playa lake habitats. Examination of modern Terran playas (e.g., the Lake Eyre basin) shows that these features span several orders of magnitude in size. While stromatolites are commonly centimeter-meter scale features, bioherms or fields of individuals may extend to larger scales. Preservation of organic matter (mats and microbes) would be favored in topographic lows such as channels or ponds of high salinity, particularly those receiving silica-rich groundwaters. These areas are likely to be located near former zones of groundwater emergence and/or where flood channels entered the paleo-playa. Fossil playa systems which may aid in assessing the applicability of this particular Mars analog include the Cambrian Observatory Hill Beds of the Officer Basin and the Eocene Wilkins Peak Member of the Green River Formation.

Bauld, John↗

Prediction of space sickness in astronauts from preflight fluid, electrolyte, and cardiovascular variables and Weightless Environmental Training Facility (WETF) training

Nine preflight variables related to fluid, electrolyte, and cardiovascular status from 64 first-time Shuttle crewmembers were differentially weighted by discrimination analysis to predict the incidence and severity of each crewmember's space sickness as rated by NASA flight surgeons. The nine variables are serum uric acid, red cell count, environmental temperature at the launch site, serum phosphate, urine osmolality, serum thyroxine, sitting systolic blood pressure, calculated blood volume, and serum chloride. Using two methods of cross-validation on the original samples (jackknife and a stratefied random subsample), these variables enable the prediction of space sickness incidence (NONE or SICK) with 80 percent sickness and space severity (NONE, MILD, MODERATE, of SEVERE) with 59 percent success by one method of cross-validation and 67 percent by another method. Addition of a tenth variable, hours spent in the Weightlessness Environment Training Facility (WETF) did not improve the prediction of space sickness incidences but did improve the prediction of space sickness severity to 66 percent success by the first method of cross-validation of original samples and to 71 percent by the second method. Results to date suggest the presence of predisposing physiologic factors to space sickness that implicate fluid shift etiology. The data also suggest that prior exposure to fluid shift during WETF training may produce some circulatory pre-adaption to fluid shifts in weightlessness that results in a reduction of space sickness severity.

Simanonok, K.↗

High Temperature Testing with Sapphire Fiber White-Light Michelson Interferometers

In the design of new aerospace materials, developmental testing is conducted to characterize the behavior of the material under severe environmental conditions of high stress, temperature, and vibration. But to test these materials under extreme conditions requires sensors that can perform in harsh environments. Current sensors can only monitor high temperature test samples using long throw instrumentation, but this is inherently less accurate than a surface mounted sensor, and provides no means for fabrication process monitoring. A promising alternative is the use of sapphire optical fiber sensors. Sapphire is an incredibly rugged material, being extremely hard (9 mhos), chemically inert, and having a melting temperature (over 2000 C). Additionally, there is a extensive background of optical fiber sensors upon which to draw for sapphire sensor configurations.

Barnes, A.↗

Selection and Characterization of Vegetable Crop Cultivars for use in Advanced Life Support Systems

Cultivar evaluation for controlled environments is a lengthy and multifaceted activity. The chapters of this thesis cover eight steps preparatory to yield trials, and the final step of cultivar selection after data are collected. The steps are as follows: 1. Examination of the literature on the crop and crop cultivars to assess the state of knowledge. 2. Selection of standard cultivars with which to explore crop response to major growth factors and determine set points for screening and, later, production. 3. Determination of practical growing techniques for the crop in controlled environments. 4. Design of experiments for determination of crop responses to the major growth factors, with particular emphasis on photoperiod, daily light integral and air temperature. 5. Developing a way of measuring yield appropriate to the crop type by sampling through the harvest period and calculating a productivity function. 6. Narrowing down the pool of cultivars and breeding lines according to a set of criteria and breeding history. 7. Determination of environmental set points for cultivar evaluation through calculating production cost as a function of set points and size of target facility. 8. Design of screening and yield trial experiments emphasizing efficient use of space. 9. Final evaluation of cultivars after data collection, in terms of production cost and value to the consumer. For each of the steps, relevant issues are addressed. In selecting standards to determine set points for screening, set points that optimize cost of production for the standards may not be applicable to all cultivars. Production of uniform and equivalent- sized seedlings is considered as a means of countering possible differences in seed vigor. Issues of spacing and re-spacing are also discussed.

Langhans, Robert W.↗

Water Quality Monitor

In the photo above, the cylindrical container being lowered into the water is a water quality probe developed by NASA's Langley Research Center for the Environmental Protection Agency (EPA) in an applications engineering project. It is part of a system- which also includes recording equipment in the helicopter-for on-the-spot analysis of water samples. It gives EPA immediate and more accurate information than the earlier method, in which samples are transported to a lab for analysis. Designed primarily for rapid assessment of hazardous spills in coastal and inland waters, the system provides a wide range of biological and chemical information relative to water pollution.

Source record↗

Pulmonary Toxicity Studies of Lunar Dusts in Rodents

NASA will build an outpost on the Moon for prolonged human habitation and research. The lunar surface is covered by a layer of fine, reactive dust. Astronauts on the Moon will go in and out of the base for various activities, and will inevitably bring some dust into the living quarters. Depressurizing the airlock so that astronauts can exit for outdoor activities could also bring dust inside the airlock to the habitable area. Concerned about the potential health effects on astronauts exposed to airborne lunar dust, NASA directed the JSC Toxicology Laboratory to determine the pulmonary toxicity of lunar dust. The toxicity data also will be needed by toxicologists to establish safe exposure limits for astronauts residing in the lunar habitat and by environmental engineers to design an appropriate dust mitigation strategy. We conducted a study to examine biomarkers of toxicity (inflammation and cytotoxicity) in lung lavage fluids from mice intrapharyngeally instilled with lunar dust samples; we also collected lung tissue from the mice for histopathological examination 3 months after the dust instillation. Reference dusts (TiO2 and quartz) having known toxicities and industrial exposure limits were studied in parallel with lunar dust so that the relative toxicity of lunar dust can be determined. A 6-month histopathology study has been planned. These instillation experiments will be followed by inhalation studies, which are more labor intensive and technologically difficult. The animal inhalation studies will be conducted first with an appropriate lunar dust simulant to ensure that the exposure techniques to be used with actual lunar dust will be successful. The results of these studies collectively will reveal the toxicological risk of exposures and enable us to establish exposure limits on lunar dust for astronauts living in the lunar habitat.

Lam, C.-W.↗

Weighting Statistical Inputs for Data Used to Support Effective Decision Making During Severe Emergency Weather and Environmental Events

National Aeronautical and Space Administration (NASA) weather and atmospheric environmental organizations are insatiable consumers of geophysical, hydrometeorological and solar weather statistics. The expanding array of internet-worked sensors producing targeted physical measurements has generated an almost factorial explosion of near real-time inputs to topical statistical datasets. Normalizing and value-based parsing of such statistical datasets in support of time-constrained weather and environmental alerts and warnings is essential, even with dedicated high-performance computational capabilities. What are the optimal indicators for advanced decision making? How do we recognize the line between sufficient statistical sampling and excessive, mission destructive sampling ? How do we assure that the normalization and parsing process, when interpolated through numerical models, yields accurate and actionable alerts and warnings? This presentation will address the integrated means and methods to achieve desired outputs for NASA and consumers of its data.

Gardner, Adrian↗

Mars 2020 Rover Adaptive Caching Assembly: Caching Martian Samples for Potential Earth Return

The Adaptive Caching Assembly (ACA) is part of the Sampling and Caching System on the Mars 2020 Perseverance Rover, and consists of multiple stations that process, hermetically seal, and store sample tubes containing collected Martian material, either rock cores or regolith samples, in preparation for caching on the surface of Mars. The ACA stations consist of seven active degrees-of-freedom, as well as a large number of passive mechanisms that must operate in extreme Mars temperature and pressure conditions. A robotic arm within the Rover manipulates the sample tubes between ACA stations as part of an end-to-end sampling sequence, and utilizes a compliant end effector to accommodate misalignments during station interactions. Stringent hardware cleanliness requirements were dictated to ensure collected samples would not be compromised, which significantly impacted the design, assembly, and test operations of the ACA. Three ACAs were assembled to support ground testing and flight operations, which were exposed to environmental testing to validate functionality in Mars-like conditions. A number of challenges existed from design through test, including volume constraints, mechanism controllability and operation, the effects of tight tolerances, and cleanliness requirements.

Lin, Justin↗

Solid propellant exhausted aluminum oxide and hydrogen chloride - Environmental considerations

Measurements of gaseous hydrogen chloride (HCl) and particulate aluminum oxide (Al2O3) were made during penetrations of five Space Shuttle exhaust clouds and one static ground test firing of a shuttle booster. Instrumented aircraft were used to penetrate exhaust clouds and to measure and/or collect samples of exhaust for subsequent analyses. The focus was on the primary solid rocket motor exhaust products, HCl and Al2O3, from the Space Shuttle's solid boosters. Time-dependent behavior of HCl was determined for the exhaust clouds. Composition, morphology, surface chemistry, and particle size distributions were determined for the exhausted Al2O3. Results determined for the exhaust cloud from the static test firing were complicated by having large amounts of entrained alkaline ground debris (soil) in the lofted cloud. The entrained debris may have contributed to neutralization of in-cloud HCl.

Cofer, W. R., III↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Comparison of GOES Cloud Classification Algorithms Employing Explicit and Implicit Physics

Cloud-type classification based on multispectral satellite imagery data has been widely researched and demonstrated to be useful for distinguishing a variety of classes using a wide range of methods. The research described here is a comparison of the classifier output from two very different algorithms applied to Geostationary Operational Environmental Satellite (GOES) data over the course of one year. The first algorithm employs spectral channel thresholding and additional physically based tests. The second algorithm was developed through a supervised learning method with characteristic features of expertly labeled image samples used as training data for a 1-nearest-neighbor classification. The latter's ability to identify classes is also based in physics, but those relationships are embedded implicitly within the algorithm. A pixel-to-pixel comparison analysis was done for hourly daytime scenes within a region in the northeastern Pacific Ocean. Considerable agreement was found in this analysis, with many of the mismatches or disagreements providing insight to the strengths and limitations of each classifier. Depending upon user needs, a rule-based or other postprocessing system that combines the output from the two algorithms could provide the most reliable cloud-type classification.

EXPLICIT PHYSICS ALGORITHMS↗

Microwave Resonator Measurements of Atmospheric Absorption Coefficients: A Preliminary Design Study

A preliminary design study examined the feasibility of using microwave resonator measurements to improve the accuracy of atmospheric absorption coefficients and refractivity between 18 and 35 GHz. Increased accuracies would improve the capability of water vapor radiometers to correct for radio signal delays caused by Earth's atmosphere. Calibration of delays incurred by radio signals traversing the atmosphere has applications to both deep space tracking and planetary radio science experiments. Currently, the Cassini gravity wave search requires 0.8-1.0% absorption coefficient accuracy. This study examined current atmospheric absorption models and estimated that current model accuracy ranges from 5% to 7%. The refractivity of water vapor is known to 1% accuracy, while the refractivity of many dry gases (oxygen, nitrogen, etc.) are known to better than 0.1%. Improvements to the current generation of models will require that both the functional form and absolute absorption of the water vapor spectrum be calibrated and validated. Several laboratory techniques for measuring atmospheric absorption and refractivity were investigated, including absorption cells, single and multimode rectangular cavity resonators, and Fabry-Perot resonators. Semi-confocal Fabry-Perot resonators were shown to provide the most cost-effective and accurate method of measuring atmospheric gas refractivity. The need for accurate environmental measurement and control was also addressed. A preliminary design for the environmental control and measurement system was developed to aid in identifying significant design issues. The analysis indicated that overall measurement accuracy will be limited by measurement errors and imprecise control of the gas sample's thermodynamic state, thermal expansion and vibration- induced deformation of the resonator structure, and electronic measurement error. The central problem is to identify systematic errors because random errors can be reduced by averaging. Calibrating the resonator measurements by checking the refractivity of dry gases which are known to better than 0.1% provides a method of controlling the systematic errors to 0.1%. The primary source of error in absorptivity and refractivity measurements is thus the ability to measure the concentration of water vapor in the resonator path. Over the whole thermodynamic range of interest the accuracy of water vapor measurement is 1.5%. However, over the range responsible for most of the radio delay (i.e. conditions in the bottom two kilometers of the atmosphere) the accuracy of water vapor measurements ranges from 0.5% to 1.0%. Therefore the precision of the resonator measurements could be held to 0.3% and the overall absolute accuracy of resonator-based absorption and refractivity measurements will range from 0.6% to 1.

Walter, Steven J.↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗